Orion OFFICE PRO LCD 750VA, FFICE PRO LCD 550VA User Manual

User Manual OFFICE PRO LCD
Inspection
The following items are inside the box:
UPS unit User manual USB cable
Remove the UPS from its package and inspect it for damage that may have occurred during shipping. If any damage is discovered, re-pack the unit and return it to the place of purchase.
Connect to Utility Power
Connect AC power cord to utility power. Then, the UPS will start to charge inside battery. For best result, charge the battery for 6 hours prior to initial use.
Plug in Equipment
Battery Backup Outlets(4)
Connect computer and monitor to the "Battery Backup" outlets. These outlets provide battery backup, EMI filtering, line conditioning, and surge protection. Battery power is automatically provided in case of power failure.
Surge-Protected Outlets(4)
Connect a printer, fax machine, or scanner to the “Surge-protected” outlets. These outlets do not provide power during power failure. CAUTION: NEVER connect a laser printer or scanner to the battery backup sockets of UPS. The equipment may overload the UPS. ATTENTION : Ne JAMAIS raccorder une imprimante laser ou un scanner pour les prises de sauvegarde batterie de l’onduleur. L’équipement peut surcharger le système UPS.
Turn On/Off the UPS
To turn on the UPS unit, press the power switch lightly. Then, the LCD will light up. To turn off the UPS unit, press the power switch again. Then, display will shut off.
Operation Display
NOTE: If backlight shuts off, you may activate it by touching the screen. REMARQUE : Si le rétro-éclairage s’éteint, vous pouvez l’activer en touchant l’écran.
Fault Code Table:
Fault condition LCD Solutions Output short circuited
Disconnect short-circuited loads and restart the UPS again.
Overload fault
Disconnect all output loads and restart the UPS again.
Overcharge
Call for service immediately.
Bad or severely discharged battery
Please replace the battery.
High output voltage fault
Call for service immediately.
Over-temperature
1. Turn off the unit and wait for cooling.
2. Or remove excessive loads and wait for cooling.
If fault alarm occurs, please call for service immediately. En cas d’alarme de panne, veuillez appeler pour service immédiatement.
www.orionpowersystems.com
UPS
Mode
LCD Description
UPS Power on
When UPS is powered on, it will enter this mode for 4 seconds.
AC Mode
LCD information will be displayed in the following order when LCD is touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
Overload in AC mode
icon will flash.
When overload occurs, alarm will beep every
0.5 second.
Battery Mode
When battery level is low,
icon will flash.
Alarm will beep every 10 seconds and LCD information will be displayed in the following order when LCD is touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity Overload in battery mode
icon will flash.
When overload occurs, alarm will beep every
0.5 second.
INSTALLATION & OPERATION
PRODUCT OVERVIEW
1. TouchscreenLCDdisplay
2. Powerswitch
3. ACinput
4. Batterybackupoutlets
5. Surge‐protectedoutlets
6. USBport
7. RJ11/RJ45
Modem/network
surgeprotection
LCD DISPLAY
User Manual OFFICE PRO LCD
This UPS utilizes voltage that may be hazardous. Do not
attempt to disassemble the unit. The unit contains no user replaceable parts. Only factory service personnel may perform repairs.
This pluggable type A equipment with battery already installed
by the supplier is operator installable and may be operated by laymen.
The mains socket outlet that supplies the UPS shall be installed
near the UPS and shall be easily accessible.
During the installation of this equipment it should be assured
that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA.
Connection to any other type of receptacle other than a
single-pole, three-wire grounded receptacle may result in shock hazard as well as violate local electrical codes.
In the event of an emergency, press the "OFF" button and
disconnect the power cord from the AC power supply to properly disable the UPS.
Do not allow any liquids or any foreign object to enter the UPS.
Do not place beverages or any other liquid-containing vessels on or near the unit.
This unit intended for installation in a controlled environment
(temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity.
Do not plug the UPS input into its own output. Do not attach a power strip or surge suppressor to the UPS. Do not attach non-computer-related items, such as medical
equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS.
Do not dispose of batteries in a fire as they may explode.
A battery can present a risk of electrical shock and high short
circuit current. The following precautions should be observed when working on batteries:
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting batteries terminal.
Internal battery voltage is 12VDC.Sealed, lead-acid, 6-cell
battery.
Servicing of batteries should be performed or supervised by
personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
When replacing batteries, replace with the same number and
type of sealed lead-acid battery.
Do not open or mutilate the battery or batteries. Released
electrolyte is harmful to the skin and eyes. It may be toxic.
Attention, hazardous through electric shock. Also with dis-
connection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole at the connectors of the battery when maintenance or service work inside the UPS is necessary.
To reduce the risk of overheating the UPS, do not cover the
UPS' cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heater or furnaces.
Unplug the UPS prior to cleaning and do not use liquid or spray
detergent.
If any abnormal situations occur that are not listed above, please call for service immediately. Si aucune des situations anormales se produisent qui ne figurent pas ci-dessus, veuillez appeler pour service immédiatement.
MODEL OP550U-LCD OP750U-LCD
CAPACITY
550VA/330W 750VA/450W
Input Voltage
120 VAC
Input Voltage Range
90-145 VAC
Output Voltage Regulation
± 10 % (Bat. mode)
Transfer Time
Typical 2-6 ms
Waveform
Simulated Sine Wave
Battery Qty / Type
(1) 12V/4.5Ah (1) 12V/5Ah
Charging Time
4-6 hours recover to 90% capacity
Dimension (LxWxH)inches
12 x 6.25 x 4
Net Weight (lbs)
5.75 6.4
Humidity (non-condensing)
0-90% RH @ 0-40°C
Noise Level
Less than 40dB
Problem Possible Cause Solutions
The UPS is not on. Press the power switch
again to turn on the UPS.
Battery voltage is too low.
Charge the battery at least 6 hours.
Nothing is displayed on the panel.
Battery fault. Replace the battery.
The UPS always on battery mode.
Power cord loose. Re-plug the power cord.
The UPS continuously beeps.
Please check the fault
code for the details.
Please check the fault code for the details.
Battery voltage is too low.
Charge the battery at least 6 hours.
Overload. Remove some unnecessary
loads. Before reconnecting equipment, please verify that the load matches the UPS capability specified in the specs.
Backup time too short.
Battery defect. Replace the battery.
SAFETY CAUTION
SAVE THESE INSTRUCTIONS-This manual contains important instructions that should be followed
during installation and maintenance of the UPS and batteries.
SPECIFICATIONS
TROUBLESHOOTING