1
TABLE OF CONTENTS
About This Guide .................................................... 1
Important Notes ...................................................... 1
Key Features .......................................................... 2
Getting Started ....................................................... 4
Power .............................................................. 4
Setup ............................................................... 5
Select Channels .............................................. 5
Change Volume .............................................. 5
Sound Light Indicators .................................... 5
Reception Signals ........................................... 5
Lost Link Alarm ............................................... 6
Key Lock ......................................................... 6
Temperature and Humidity ..................................... 6
…C/ …F Unit....................................................... 6
Comfort Indicator ............................................. 6
Hi and Low Temperature Alarm ...................... 7
Reset ...................................................................... 7
Safety and Care ...................................................... 7
Warnings ................................................................ 7
Specifications ......................................................... 8
EC Declaration of Conformity ................................. 8
FCC Information ..................................................... 8
BABY MONITOR
WITH THERMO HYGROMETER
MODEL: BB122 / BBR122
USER S MANUAL
ABOUT THIS GUIDE
Congratulations on your selection of the Baby Monitor (BB122/ BBR122). This baby monitor includes the following conveniences:
¥ Big LCD Display and LCD backlight on Parent unit
for easy viewing
¥ Measurement of Temperature and humidity of
where your baby is ¥ High and low temperature alarm ¥ Baby-face comfort indicator ¥ Lost-link alarm
Keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know.
In this box, you will find:
¥ BB122 Parent Unit ¥ BBR122 Baby Unit ¥ AC adaptor x 2 ¥ Rechargeable 4.8V NiMH battery pack for BB122
IMPORTANT NOTES
¥ This baby monitor is not intended and should not be
used as a replacement for responsible adult supervision. It only acts as a support for your child-caring purpose. Any type of liability beyond statutory warranty regulations is excluded.
Page 3
2
¥ Please ensure the baby unit and the adaptor cable are
always out of reach of your child and at least 1 meter away.
¥ Never place the Baby unit inside the baby crib or near
water (e.g., bathtub, wet basement, etc.)
KEY FEATURES
PARENT UNIT (FRONT & BACK) DESCRIPTION
1. LCD Display
2. Sound Light Indicators
3. Channel button
4. Temp button
5. Power/Light button
6. Rechargeable battery connector
7. …C/ …F button
8. Reset button
9. Speaker
10. Battery Compartment
11. Hand-strap
12. Up/Down button
13.
Headphone Jack with cover
14.
AC Adaptor Jack with cover
15. Belt-clip
15
3
2
6
9
4
5
11
10
13
12
14
7
8
1
Page 4
3
BABY UNIT (FRONT & BACK)
DESCRIPTION
1. LCD Display
2. Channel button
3. Up button
4. Microphone
5. Flip-out table stand
6. Humidity and Temperature Sensor
7. AC Adaptor Jack
8. Wall-mount holder
9. Reset button
1
2
3
4
Page 5
4
GETTING STARTED
POWER
The AC power adaptor and rechargeable battery pack for the Parent Unit and AC power adaptor for the Baby Unit are supplied with this product. Recharge the battery pack whenever the battery capacity levels is low.
Baby Unit
Connect the 5V AC adaptor to an AC mains socket and then connect the cord to the DC power supply socket of the Baby Unit. The display and LED indicator will light up when power is on. The selected channel no. will be shown on the display.
Parent Unit
The Parent Unit uses a rechargeable battery pack. First, open the battery cover at the back and connect the battery pack to the connector inside the battery compartment. Put the battery pack inside and close the battery cover.
Then, connect the 9V AC adaptor to an AC main socket and then connect the cord to the DC power supply socket of the Parent Unit. The unit will begin charging and the charging indicator will be displayed, otherwise reset the parent unit.
CHARGING BATTERY
Baby Unit,s humidity
Key lock icon
Battery capacity level
Lo temperature alarm indicator
Hi temperature alarm indicator
Baby Unit,s temperature
Volume level
Reception strength level & channel display
Baby-face comfort indicator
Page 6
5
At first-time use, please full-charge the battery for 12 hours, and then reset the parent unit before starting up. When the battery is fully charged, it can be used cordlessly for up to 8 hours.
TURN ON/OFF THE PARENT UNIT
¥ To turn on press and hold the power button for 3 seconds. ¥ To turn off press and hold the power button for 3 seconds.
SETUP
Power up the Baby unit first and then the Parent Unit. When first used, both units are already preset with same channel (e.g., CH. 1). Position the Baby Unit using either the recess hole on the back or the table-stand. For best results:
¥ Place the units away from electrical or mechanical
objects.
¥ Place the units out of direct sunlight and moisture. ¥ Do not place the Baby unit more than 200 meters (656
feet) from the Parent Unit.
¥ Minimize obstructions such as doors, walls, and furniture
since this will decrease the transmission range between the 2 units.
You may need to experiment with various locations to get the best reception.
SELECT CHANNELS
You can change the channel if there is interference or problem with linking the 2 units.
Baby Unit
Press and hold CHANNEL for 2 seconds. Use UP to change the channel number from 1 to 10. Press CHANNEL again or wait for 10 seconds to confirm.
Parent Unit
Press and hold CHANNEL for 2 seconds. Use UP/ DOWN to change to the same channel number as the Baby unit s. Press CHANNEL again or wait for 10 seconds to confirm.
CHANGE VOLUME
Use UP/ DOWN on the Parent unit to change the volume. There are 4 volume levels.
SOUND LIGHT INDICATORS
The sound light indicators can alert you visually to baby s sound even when the volume is turned down. The louder the sound received from the baby unit, more lights will be on.
RECEPTION SIGNALS
You can see if the status of the reception strength through the reception strength tower icons.
LOST
LINK
Very
Weak
Weak Normal Strong
Page 7
6
LOST LINK ALARM
When the Parent Unit cannot receive data from the Baby unit (due to interference or out-of-range distance), lost link alarm will be on. The reception strength tower will be blinking and alarm sound will go off for 2 minutes. Re­position the units. The alarm sound will stop automatically once signal is received again or you can press any key to stop the alarm sound.
If signal cannot be received after the 2-minute alarm, the tower icon will continue to flash.
KEY LOCK
This function is used to prevent accidental key-press on the Parent Unit. Press and hold CHANNEL and TEMP together for 3 seconds to activate/ deactivate the key­lock function.
TEMPERATURE AND HUMIDITY
The baby unit can measure the surrounding temperature and relative humidity. The measured data can then be transmitted to and displayed on the Parent Unit.
Temperature is shown on the 2nd line and the humidity is shown on the 3rd line.
ºC/ ºF UNIT
Press the C/ F button inside the battery compartment of the Parent unit to change the temperature display unit in degree Celsius or Fahrenheit.
COMFORT INDICATOR
By calculating both the temperature and humidity together a baby-face comfort indicator will be shown so that you will know if your baby feels comfortable, hot or cold in the room.
Above
26.1ºC (79ºF)
19.1 - 26.0 ºC
(66.4ºF -
78.8ºF)
Below
19.0ºC
(66.2ºF)
55%­ 75%
Above 75%Below 55%
Page 8
7
No Data received
HI AND LOW TEMPERATURE ALARM
With this function you can be alerted when the temperature becomes too hot or too cold for your child.
Press TEMP to scroll through the following display modes:
¥ Current Temperature ¥ Hi-Temperature Alarm ¥ Low-Temperature Alarm
To set the alarm, press and hold TEMP for 2 seconds and the value will be flashing. Use UP or DOWN to change the value. Press TEMP to confirm. The alarm will be activated automatically.
When the measured temperature goes above the High Temperature Alarm setting or below the Low Temperature Alarm setting, a 2-minute alarm sound will be given out. Press any key to stop the alarm sound.
RESET
The RESET button is located in the battery compartment. Press it with the tip of a blunt object (such as a ball point
pen) whenever you change the batteries, or whenever performance is not behaving as expected (e.g., unable to establish link with remote unit). This will return all settings to default value, and you will lose all stored information.
SAFETY AND CARE
Wash the unit with a slightly damp cloth and mild detergent. Avoid dropping the unit or placing it in a high-traffic location.
WARNINGS
This product is designed to give you years of service if handled properly. Observe the following guidelines:
¥ Never immerse the unit in water. This can cause
electrical shock and damage the unit.
¥ Do not subject the units to extreme force, shock, or
fluctuations in temperature or humidity.
¥ Do not tamper with the internal components. ¥ Remove the batteries if storing this product for a long
period of time.
¥ Do not scratch the LCD display. ¥ Do not make any changes or modifications to this
product. Unauthorized changes may void your right to use the product.
¥ The contents of this user guide are subject to change
without notice. Images not drawn to scale.
Page 9
8
SPECIFICATIONS
POWER
Parent unit: Rechargeable 4.8V NiMH battery pack. Power Adapter - Input : AC/230V - 50Hz 0.04A
- Output : DC9V 300mA Baby unit: Power Adapter - Input : AC/230V - 50Hz 0.03A
- Output : DC5V 200mA
Temperature
Unit : C or …F Range : -10 to 50 C (14 to 122 …F) Resolution : 0.1 …C ( 0.2 …F)
Relative humidity
Range : 25% to 95% Resolution : 1%
RF frequency : 2.4GHz Range: up to 200 meters (656 feet) with no obstructions