EC Declaration of Conformity.................................. 20
INTRODUCTION
Thank you for selecting the Oregon Scientific™
BAR998HGN/BAR993HGN Voice Activated Wireless
Weather Station. This powerful device bundles voice
recognition, time keeping, and weather monitoring features
into a single tool you can use from the convenience of
your home. In this box, you will find:
•Main unit
•Remote sensor (RTGR328N)
•Optional UV sensor (UVR138)
•AC adapter
•Batteries
BAR998HGN — BAR998HGN Main unit + RTGR328N
Remote sensor
BAR993HGN — BAR998HGN Main unit + RTGR328N
Remote sensor + UVR138 UV Sensor
Keep this manual handy as you use your new product. It
contains practical step-by-step instructions, as well as
technical specifications and warnings you should know.
2
Page 3
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more
about other Oregon Scientific products such as digital
cameras, projection clocks, health and fitness gear, and
weather stations. The website also includes contact
information for our customer service department, in case
you need to reach us.
PRODUCT OVERVIEW
LCD SCREEN
1. Clock / Alarm Area: Radio controlled clock; alarms
2. UVI / Barometer Trend Area: UV level and barometric
pressure bar chart
3. UVI / Barometric Measurement Area: UV Index and
barometric readings
4. Temperature / Heat Index Area: Readings and trend
lines; sensor channel number; battery status
5. Humidity / Comfort Zone Area: Readings and trend
lines; comfort zone
6. Microphone for Voice Recognition
7. World Cities Area: current, sunrise, sunset, moon
rise, and moon set times for 130 cities
9. Calendar Area: Calendar, voice recognition icon, AC
power icon
3
EN
Page 4
EN
TOP VIEW
1. MODE – change settings / display
2. ALARM / – view alarm status; set alarm
3. HISTORY – view historical barometer and UV
readings
4. SNOOZE / LIGHT – activate 8-minute snooze or
backlight
5. CHANNEL – switch remote sensor
6. MEMORY – view current and saved temperature,
humidity and heat index readings
7. SELECT – switch Areas
BACK VIEW
1. UP – increase setting / activate radio-controlled clock
and voice recognition
2. DOWN – decrease setting / deactivate radio-
controlled clock and voice recognition
°C / °F
3.
4. Barometer unit (mb/inHg)
5. RESET
6. Battery case release button
7. Battery compartment
8. AC Adaptor plug
4
Page 5
REMOTE SENSOR (RTGR328N)
1. LCD display
2. LED Status indicator
3. Ventilation duct
EN
1. Signal reception
2. Channel number
3. Low battery icon
4. Time
1
2
5. Temp (°C or °F)
6. Humidity %
7. Temp / Humidity
1
2
3
4
5
6
7
1. Wall mount
2. Channel switch (1 – 5)
3. RESET
4. °C / °F
5. Search
6. EU/UK radio signal
format switch
7. Battery compartment
8. Fold-out stand
3
1
2
3
4
5
6
7
8
GETTING STARTED
BATTERIES
Insert batteries before first use, matching the polarity as
shown in the battery compartment. For best results,
install batteries in the remote sensor before the main unit.
Press RESET after each battery change.
Do not use rechargeable batteries.
NOTE
shows when batteries are low.
UNIT
MainCalendar Area
RemoteTemp / Heat Index Area
UV SensorUVI / Barometric
5
LOCATION
Measurement Area
Page 6
EN
AC ADAPTER (MAIN UNIT)
The AC power adapter socket is located at the bottom of
the main unit. Batteries are for back-up purposes only;
the adapter is required for Voice Recognition.
shows in the Weather Forecast Area when AC
adapter is not plugged in.
CHANGE SETTINGS
1. Press SELECT to
switch between
Areas. ▲ indicates
the selected Area.
2. Most Areas have alternate display options (for
example, Clock / Alarm or Barometer / UVI).
Press MODE to switch options, or ALARM to switch
between Clock and Alarm.
3. Press and hold MODE for 2 seconds to enter setting
mode.
4. Press UP or DOWN to change settings.
5. Press MODE to confirm.
TILT THE DISPLAY
You can tilt the display
back for better viewing or
audio sound. Hold the base
of the unit with your hand,
and then gently push the
top back.
REMOTE SENSOR
This product is shipped with the RTGR328N Thermo/Hygro
Sensor and an optional UVR138 Ultraviolet Sun Ray
Sensor. The main unit can collect data from up to 6 sensors
(5 Thermo / Hygro Sensors and 1 UV Sensor). (Additional
sensors sold separately.)
The RTGR328N Sensor collects temperature and humidity
readings, and signals from official time-keeping
organizations for the radio-controlled clock.
For information about the UVR138, refer to the UVR138
User Manual.
6
Page 7
THERMO / HYGRO SENSOR SETUP (RTGR328N)
1. Open the battery compartment with a small Phillips
screwdriver.
2. Insert the batteries.
3. Set the channel and radio signal format. The
switches are located in the battery compartment.
SWITCHOPTION
ChannelChannel 1 – 5. If you are using
more than one sensor, select a
different channel for each sensor
Radio SignalEU (DCF) / UK (MSF)
Format
4. Press RESET. Then set the temperature unit.
SWITCHOPTION
Temp°C / °F
5. Close the battery compartment.
6. Secure the sensor with the wall mount or using the
fold-out stand.
FOLD OUT STAND
1. Fold-out the stand
2. Lock it into place
1
2
For best results:
•Insert the batteries and select the unit, channel, and
radio signal format before you mount the sensor.
•Place the sensor out of direct sunlight and moisture.
•Do not place the sensor more than 70meters
(230 feet) from the main (indoor) unit.
•Position the sensor so that it faces the main (indoor)
unit, minimizing obstructions such as doors, walls,
and furniture.
•Place the sensor in a location with a clear view to
the sky, away from metallic or electronic objects.
NOTE
The transmission range may vary and is
subject to the receiving range of the main unit.
Y ou may need to experiment with various locations to get
the best results.
7
EN
Page 8
EN
CLOCK
This remote sensor can automatically synchronize the date
and time with official time-keeping organizations in
Frankfurt (Germany) and Rugby (England). When the
sensor is within 1500 km (932 miles) of a RF signal, the
reception icon will blink during reception.
When the sensor receives the radio-controlled clock signal
and is paired with the main unit, the clock in the main unit
will be automatically updated.
SET RADIO SIGNAL FORMAT
The RADIO SIGNAL FORMAT switch is located inside
the battery compartment. Select EU (DCF) or UK (MSF).
Then, press RESET.
Reception takes 2 – 10 minutes to complete. Once
complete, the icon will stop blinking.
STRONG SIGNAL WEAK OR NO SIGNAL
OR
To force a manual RF clock reception, press and hold
SEARCH for 2 seconds.
SENSOR DATA TRANSMISSION
Data is sent from the sensor(s) every 60 seconds. The
reception icon shown in the T emperature / Heat Index Area
indicates the status.
ICONDESCRIPTION
--- shows in Temp /The selected sensor
Humidity Areascannot be found.
SENSOR SEARCH
T o search for a Thermo / Hygro sensor, press SELECT to
navigate to the T emperature/ Heat Index Area. ▲ will show
in the lower right corner of the Area. Then, simultaneously
press and hold MEMORY and CHANNEL for 2 seconds.
To search for the UV sensor, press SELECT to navigate
to the UVI / Barometric Trend Area. ▲ will show in the
lower left corner of the Area. Then, press and hold
MEMORY and CHANNEL for 2 seconds.
NOTE
If the sensor is still not found, check the batteries.
8
Main unit is
searching
for sensors.
At least 1 channel
has been found.
Sensor 1 is sending
data. (The number
shows which sensor
is selected.)
Search for the sensor
or check batteries.
Page 9
CLOCK AND CALENDAR
This product tracks the time and date for 1 local location,
and 1 world city that you choose. The information is shown
in the top left and bottom right areas of the display.
RADIO-CONTROLLED CLOCK
The time and date are automatically updated by radio
controlled clock signals from official time-keeping
organizations in Frankfurt (Germany) and Rugby (England)
unless you disable this feature. The signals are collected
by the remote sensor (RTGR328N) whenever it is within
1500 km (932 miles) of a signal.
Initial reception takes 2 – 10 minutes, and is initiated when
you first setup the unit, and whenever you press RESET.
Once complete, the reception icon will stop blinking.
The icon shown in the Clock Area indicates 2 factors:
•Connection between the main unit and the sensor
that collects RF signals ( )
•RF signal reception ( )
Both parts will show ( ) when the sensor that receives
RF signals is selected and the RF signal is strong. (If you
select another sensor, or will show to indicate
whether the RF signal is strong.)
If no signal is found, check the sensor batteries.
TURN RADIO-CONTROLLED CLOCK ON/OFF
If you wish to manually set the clock, you must first disable
the radio-controlled feature. To do this, navigate to the
Clock / Alarm Area. Then, press and hold DOWN on the
main unit for 2 seconds. T o enable it, navigate to the Clock
/ Alarm Area, then press and hold UP for 2 seconds.
The house icon
indicates that the
radio-controlled
clock is ON. No
icon means that
it is OFF.
SET CLOCK
You only need to do this if you have disabled the radio
controlled clock, or if you are too far from a RF signal.
1. Press SELECT to
navigate to the Clock
Area. ▲ will show in
the lower left corner
of the Area.
2. Press and hold MODE
for 2 seconds. The
Clock and World
City Areas will blink.
3. Press UP or DOWN to choose the city you are
LOCATED IN. Press and hold for rapid search.
4. Press MODE again.
9
EN
Page 10
EN
5. Select the 12/ 24 hour format, hour, minute, year,
date/month format, month, date, display language,
and (optional) volume level for the Voice
Recognitionfeature. Press UP or DOWN to change
the setting. Press MODE to confirm.
NOTE
The language options are (E) English, (F)
French, (D) German, (I) Italian, and (S) Spanish. The
language you select determines the weekday display
and the spoken language for the Voice Recognition
prompts.
NOTE
Voice Recognition must be activated (16)
before you can set the volume level. The number of
bars shown after the icon (
(Low, Medium, or High).
WORLD CITY DISPLAY
With this product, you can
view the current, sunrise,
sunset, moonrise, and
moon set times for up to
130 world cities.
1. Press SELECT to navigate to the World Clock Area.
2. T o scroll through the information for the selected city,
press MODE.
) indicates the level
3. To select another city, press and hold MODE for 2
seconds. Then, press UP or DOWN to select the
3-digit code for the city. For a list of W orld City Codes,
refer to the enclosed sheet.
4. Press MODE again when you are finished.
ALARMS
This product has 2 alarms: the Daily Alarm and a Pre
Alarm for snowy weather. The Daily Alarm can be set to
go off at the same time every day. The Pre-Alarm sounds
only when the Daily Alarm is activated and the recorded
temperature from Channel 1 Sensor falls to 2°C (35.6 °F)
or below.
SET DAILY ALARM
1. Press SELECT to navigate to the Clock Area. ▲ will
show in the lower left corner of the Area.
2. Press ALARM /
at the top.)
3. Press and hold ALARM /
4. Select the hour and minute. Press UP or DOWN to
change settings. Press ALARM /
shows when the Alarm is set.
10
to view the Alarm. (AL will show
for 2 seconds.
to confirm.
Page 11
SET PRE-ALARM
The Pre-Alarm can be set to sound 15,30,45, or 60 minutes
before the Daily Alarm. It will sound whenever the recorded
temperature from Channel 1 Sensor falls to 2°C (35.6°F)
or below.
For example, if you set the Alarm to 7:00 AM, and the Pre
Alarm to 45 minutes, the Pre-Alarm will sound at 6:15 AM
provided the outdoor temperature at Channel 1 Sensor is
2°C or below.
1. Set up and activate the Daily Alarm.
2. Press ALARM /
(
3. Press and hold ALARM /
4 . Press UP or DOWN to select 15, 30, 45 or 60 minutes.
This is the amount of time the Pre-Alarm will sound
BEFORE the Daily Alarm. The Pre-Alarm is
automatically activated when you select a time.
5. Press ALARM /
shows when the Pre-Alarm is set.
NOTE
The daily Alarm will NOT function until the
next day once if the Pre-Alarm has been triggered.
Also, if you deactivate the Alarm, the Pre-Alarm is also
automatically deactivated.
to switch to Pre-Alarm view.
will show at the top.)
for 2 seconds.
to confirm.
ACTIVATE ALARM
Navigate to the Clock
Area, then press ALARM
to switch to Daily
/
Alarm or Pre Alarm view.
To activate or deactivate
the alarm, press UP or DOWN.
When the Alarm time is reached, the crescendo alarm will
sound for 2 minutes. Press any key to silence the alarm.
It will sound at the same time the next day.
ICONDESCRIPTION
Daily Alarm is activated and will
sound at the set time.
Pre-Alarm is activated and will
sound at the specified time if the
temperature falls to 2°C or below
(35.6 °F).
-:—Alarm is not activated and will
SNOOZE
Press SNOOZE / LIGHT to temporarily disable the Alarm
for 8 minutes.
11
not sound.
or will blink while Snooze is on.
EN
Page 12
EN
BAROMETER
This product tracks fluctuations in barometric pressure to
provide the weather forecast (13), and the current and
past 24 hours barometric pressure history. Measurements
are recorded by the main (indoor) unit.
VIEW BAROMER AREA
Press SELECT to navigate to the Barometer Area.
is NOT shown, press MODE.
If
Barometric data is
shown in two areas.
The top area shows
a 24-hour bar chart.
The bottom area
shows current and
historical readings.
SELECT MEASUREMENT UNIT
Press mb / inHg on the back of the weather station.
VIEW BAROMETER HISTORY
Navigate to the Barometer Area, then press HISTORY
repeatedly to scroll through the measurements. The
number shown in the HR box indicates how long ago each
measurement was taken (e.g., 2 hours ago, 3 hours ago,
etc.).
BAR CHART DISPLA Y
The bar chart visually shows
atmospheric changes from
the current hour [0] to
24 hours prior (-24).
SET ALTITUDE
Set the altitude to match how far above or below sea level
you are living. This ensures that the barometric pressure
readings are accurate.
1. Navigate to the Barometer Area.
2. Press and hold HISTORY for 2 seconds.
3. Press UP or DOWN to set the altitude in 10 meter
increments (-100m to 2500m).
4. Press HISTORY to confirm.
12
Page 13
WEATHER FORECAST
This product forecasts the next 12 to 24 hours of weather
within a 30 – 50 km (19 – 31 mile) radius. The forecast is
based on barometric pressure trend readings.
The middle area
shows an animated
icon indicating the
forecasted weather.
WEATHER FORECAST ICONS
ICONDESCRIPTION
CLEAR
DAY NIGHT
PARTLY CLOUDY
DAY NIGHT
CLOUDY
RAINY
SNOWY
NOTE
The nighttime icon displays from 6 PM to 6 AM.
When the Channel 1 sensor records a temperature of 2°C
(35.6 °F) or lower, the RAINY icon becomes SNOWY.
UV MEASUREMENT
(WITH OPTIONAL UVR138)
With the optional UVR138 Ultra-Violet Radiation Sensor,
the following information is at your fingertips:
•10-hour Ultra-violet index (UVI) record
•Automatic calculation of acceptable UV exposure
times based on pre-set user profiles (4 users
maximum)
•UVI Danger Alert when UV index reaches unsafe
levels
UV data is shown in the same area as the Barometer. Press
SELECT to navigate to the Barometer Area, then press
MODE to display the
UVR138 User Manual for more information.
13
UV icon and data. Refer to the
EN
Page 14
EN
TEMPERA TURE AND HUMIDITY
The weather station can display the following information
from any of the 5 remote sensors:
•Current, minimum, and maximum temperatures and
relative humidity percentages.
•Heat index that shows the apparent, or felt, current
temperature, trend line, and minimum / maximum
readings.
•Comfort level indicator and trend line (rising, falling,
or steady).
Data is collected and displayed every 60 seconds.
VIEW TEMPERATURE AND HUMIDITY AREA
Press SELECT to navigate to the Temperature and
Humidity Areas.
Temperature and Heat Index
data is given at the top;
Humidity is below.
SELECT MEASUREMENT UNIT
°C / °F on the back of the weather station.
Press
SELECT SENSOR CHANNEL
Press CHANNEL to switch between sensors 1 - 5.
The house icon shows the
selected remote sensor.
T o auto-scan between sensors, press and hold CHANNEL
for 2 seconds. Each sensor’s data will be displayed for
3 seconds.To end auto-scan, press CHANNEL or
MEMORY with the Temperature / Humidity Area selected.
NOTE
If you select a sensor that collects only
temperature data, the humidity will not be shown.
MINIMUM / MAXIMUM RECORDS
Press MEMORY repeatedly to
view current, maximum and
minimum records for the selected
sensor. To clear the records, press
and hold MEMORY for 2 seconds.
A beep will sound to confirm that
the memory has been cleared.
TEMPERATURE AND HUMIDITY TREND
The trend lines are shown next to the Temperature and
Humidity readings.
TrendRisingSteadyFalling
ICON
14
Page 15
COMFORT ZONE
The Comfort Zone indicates how comfortable the climate
is, based on current temperature and humidity
measurements.
ZONETEMPERATUREHUMIDITY
Any>70%
20 – 25 ° C40 – 70%
(68 - 77 ° F)
Any<40%
This information is shown in the Humidity Area when the
current measurement is displayed.
HEAT INDEX
The Heat Index indicates apparent, or felt, temperature.
This can significantly differ from measured temperatures
on hot, low humidity days since it estimates the effects of
heat stress (temperature and humidity) on the body.
To view the Heat Index,
press MODE while the
Temperature and Humidity
Area is selected.
HEAT INDEX LEVELS
IF THETHEN THE DANGER LEVEL
HEATFOR PROLONGED OUTDOOR
27 to 32°CCAUTION
(80 to 89°F)(possible heat fatigue)
32 to 40°CEXTRA CAUTION
(90 to 104°F)(possible sunstroke, heat cramps,
41 to 54°CDANGER
(105 to 129°F)(likely sunstroke, heat cramps, or
54 to 93°CVERY DANGEROUS
(130 to 199°F)(possible heat stroke or sunstroke)
“HH”OVER RANGE
VIEW MIN / MAX HEAT INDEX LEVELS
Press MEMORY while the Heat Index Area is shown.
15
INDEX IS PHYSICAL ACTIVITY IS
or heat exhaustion)
heat exhaustion; possible
heat stroke)
(the temperature falls outside the
26 to 93°C (80 to 199°F) range)
EN
Page 16
EN
VOICE RECOGNITION
This product has a built-in sensor for recognizing voice
commands. When activated, the product can tell you the
current time, alarm, and weather conditions in response
to a voice command that you give it.
The language for the Voice Recognition feature is selected
when you set the clock ( 9).
ACTIVATE VOICE RECOGNITION PROMPT
Plug in the AC power adapter (it must be plugged in for
the feature to work). Press SELECT to navigate to the
Clock Area. Then, simultaneously press and hold UP and
DOWN for 3 seconds. A welcome message in the selected
language will broadcast.
displays
when Voice
Recognition is ON
SET VOLUME LEVEL
There are 3 volume levels: Low, Medium and High. To set
the volume level, first activate Voice Recognition.
will display. ) Then, access the Clock Settings
(
Mode to select the volume level ( 10, Step 5).
VOICE RECOGNITION COMMANDS
The product responds to the following voice commands:
COMMANDRESPONSE
WEATHER STATIONPrepares to access
ALARMAlarm status (on or off)
TIMECurrent time
WEATHERWeather forecast,
TIPS FOR USING VOICE RECOGNITION
Face the product, no more than 2 meters (6 feet) away.
Speak slowly and distinctly. Minimize background noises,
such as the television or other people talking. If the weather
station does not recognize your command, it will ask you
to repeat it. After 2 unsuccessful attempts you will hear a
beep. To begin again, say “Weather Station” to re-enter
the program, then repeat the command.
The product will not respond to any command when it is
talking. Say command only when it has finished.
16
weather station data.
Further command is
needed.
and setting
current temperature
and humidity for
selected sensor.
Page 17
BACKLIGHT
Press SNOOZE / LIGHT to illuminate the backlight for 5
seconds.
RESET SYSTEM
The RESET buttons are located on the back of the main
unit and in the battery compartment for the sensors. Press
RESET when you change the batteries and whenever
performance is not behaving as expected (for example,
unable to establish radio frequency link with remote unit
or radio-controlled clock).
NOTE
When you press RESET, all settings will return
to default value, and you will lose all stored information.
SAFETY AND CARE
Clean the unit with a slightly damp cloth and alcohol- free
mild detergent. Avoid dropping the unit or placing it in a
high-traffic location.
WARNINGS
This product is designed to give you years of service if
handled properly. Observe the following guidelines:
•Never immerse the unit in water. This can cause
electrical shock and damage the unit.
•Do not subject the main unit to extreme force,
shock, or fluctuations in temperature or humidity.
•Do not tamper with the internal components.
•Do not mix new and old batteries or batteries of
different types.
•Do not use rechargeable batteries with this product.
•Remove the batteries if storing this product for a
long period of time.
•Do not scratch the LCD display.
Do not make any changes or modifications to this product.
Unauthorized changes may void your right to use the
product. The technical specifications of this product and
contents of this user guide are subject to change without
notice. Images not drawn to scale.
17
EN
Page 18
EN
TROUBLESHOOTING
Check here before contacting our customer service
department.
ProblemSymptomRemedy
BarometerStrangeSet altitude / unit
Cannot changeCheck sensors.
channelOnly one sensor is
working ( 8)
ProblemSymptomRemedy
VoiceDoes not workIs the AC adapter
recognitionplugged in? ( 6)
SPECIFICATIONS
MAIN UNIT DIMENSIONS
L x W x H207 x 119 x 40 mm
Weight406 grams (0.9 lbs) with
REMOTE UNIT DIMENSIONS
L x W x H70 x 24.5 x 116mm
Weight156 grams (0.34lb.) with
18
(8,15 x 4.69 x 1.58 inches)
battery
(2.76 x 0.96 x 4.57 inches)
battery
Is voice recognition
on? ( 16)
Try again once the
product has
stopped talking.
Speak clearly and
slowly.
Page 19
TEMPERATURE
Unit°C or °F
Indoor Range-5 °C to 50 °C
(23 °F to 122 °F)
Outdoor Range-20 °C to 60 °C
(-4 °F to 140 °F)
Resolution0.1 °C (0.2° F)
Comfort20 °C to 25 °C
(68 °F to 77 °F)
MemoryMin / Max
Trend+/- 5° (°C or °F)
RELATIVE HUMIDITY
Range25% to 95%
Resolution1%
Comfort40% to 70%
MemoryMin / max
Trend+/- 3%
BAROMETER
Unitmb/hPa or inHg
Range500 to 1050 mb
(14.77 to 31.01 inHg)
Resolution1 mb (0.03 inHg)
Altitude-100 to 2500 meters
(-328 to 2734 feet)
DisplaySunny, partly cloudy, cloudy, rainy,
snowy
REMOTE UNIT (RTGR328N)
RF frequency433 MHz
RangeUp to 70 meters (230 feet)
Transmissionevery 1 minute
Channel No.1, 2, 3,4 or 5
Unit°C or °F
RADIO CONTROLLED CLOCK
Synchronization Auto or disabled
Clock displayHH:MM:SS
Hour format12hr AM/PM (MSF format)
CalendarDD/MM or MM/DD;
AlarmDaily & Pre-Alarm; 2- minute
Snooze8 minutes
POWER
Main unit
Power adapter6V AC adapter
Batteries3 x UM-3 (AA) 1.5V alkaline
Thermo-Hygro
Remote sensor2 x UM-3 (AA) 1.5V alkaline batteries
19
with no obstructions
24hr (DCF format)
weekday in 5 languages (E, G, F, I,S)
crescendo
batteries (back-up)
EN
Page 20
EN
EC-DECLARATION OF CONFORMITY
This product
Article 3 of the R&TTE 1999/5/EC Directives,if used for its
intended use and that the following standard(s) has/have
been applied:
Radio frequency spectrum
(Article 3.2 of the R&TTE Directive)
applied standard(s)
complies with the essential requirements of
ETSIEN300220-3(Ver.1.1.1):2000-09
Additional information:
The product therefore conforms with the Low Voltage
Directive 73/23/EC,the EMC Directive 89/336/EC and
R&TTE Directive 1999/5/EC (appendix II) and carries the
respective CE marking.
Electromagnetic compatibility
(Article 3.1.b of the R&TTE Directive)
applied standard(s)
ETSIEN301489-1-3(Ver.1.4.1):2002-08
Safety of information technology equipment
(Article 3.1.a of the R&TTE directive)
applied standard(s)
EN 60950:2000
Carmelo Cubito
Agrate Briznaza (MI) / Italy January 2004
EC Representative of Manufacturer
COUNTRIES RTTE APPROVAL COMPLIED
All EC Countries, Switzerland
20
and Norway
CH
N