Congratulations on your purchase of the BAR898HGA LongRange Wireless Weather Station with In-Out Thermo-Hygrometer
and RF Clock. This unit is an all-in-one weather forecasting
device which has multiple weather-related functions. Also, with
an internal antenna the reception range of this unit can be up to
328 feet (100 meters).
The BAR898HGA, a weather forecasting device, has several
weather related functions. The main feature is that it takes and
records temperatures and humidities in more than one location.
Using a wireless remote thermo-hygro sensor, it can
simultaneously monitor temperatures and humidities in three
remote locations. The unit will show temperature and humidity
trends as well as record maximum and minimum temperature
and humidity readings. BAR898HGA is able to receive and
display readings from up to 3 remote sensors.
As part of the weather forecasting function, the unit has a built-in
barometer that displays atmospheric pressure. Using kineticmovement graphic illustrations the unit displays atmospheric
pressure trends and displays forecasts as sunny, partly cloudy,
cloudy, rainy and snowy.
This unit also has a Radio Frequency (RF) controlled clock. It can
automatically synchronize its current time and date when it is
brought within range of the radio signal generated from the U.S.
Atomic Clock.
Other features of BAR898HGA include LCD and key-panel
backlight, rotatable display unit for multi-angle viewing and a
Daily crescendo alarm with an eight-minute snooze function.
No wire installation is required between the main and remote
units as this unit operates at 433 MHz.
However, please note that the Atomic Clock cannot be used
outside the U.S.
1
GB
FEATURES : MAIN UNIT
A. LCD DISPLAY
A1. WEATHER FORECAST WINDOW
- Graphically illustrates the weather forecast
- Indicates trends in atmospheric pressure
- Indicates when main unit battery is low
A2. TEMPERATURE WINDOW
- Displays current, minimum or maximum indoor and
remote temperature
- Indicates the temperature trend
A3. HUMIDITY WINDOW
- Displays current, minimum or maximum indoor and
remote humidity
- Indicates the humidity trend
- Displays the Comfort Level
- Indicates when the battery of the remote sensor is low
A4. ATMOSPHERIC PRESSURE WINDOW
- Displays the current or historical (last 24 hours)
barometric reading
A5. TIME / DATE / ALARM WINDOW
- Displays the current time, date (month/day),
daily alarm function
- Radio Frequency (RF) status indicator [
B. CONTROL BUTTONS - FRONT PANEL
B1. [ MODE ] BUTTON
- Changes the display mode of the clock, and alters time/
date setting
B2. [
] BUTTON
- Displays the daily alarm time or changes the
corresponding alarm time
]
2
B3. [ MEMORY ] BUTTON
- Displays minimum and maximum temperature and
humidity readings, and erases memory data
B4. [ CHANNEL ] BUTTON
- Displays the temperature and humidity readings of the
indoor or remote sensor
B5. [ SNOOZE / LIGHT ] BUTTON
- Activates the snooze function or turns on the backlight
B6. DETACHABLE TABLE - STAND
( [ SNOOZE / LIGHT ] STAND - BUTTON)
- Acts as the [ SNOOZE / LIGHT ] button when attached
to the display unit
C. CONTROL BUTTONS - SIDE PANEL
C1 & C2. UP [ ] & DOWN [ ] BUTTONS
- Increases or decreases the value of a setting
D. CONTROL BUTTONS - BACK PANEL
D1. BATTERY COMPARTMENT
- Accommodates four (4) pieces of UM-3 or "AA" size
batteries
D2. [ HISTORY ] BUTTON
- Displays the barometric reading for the last 24 hours, or
enters the altitude compensation setting
3
GB
GB
D3. [ mb / hPa - inHg ] SLIDE SWITCH
- Selects between "mb / hPa" or "inHg" pressure unit
display
D4. [
°C / °F ] SLIDE SWITCH
- Selects between Centigrade (°C ) or Fahrenheit (°F)
temperature unit display
D5.[ZONE] BUTTON
Press to select among the 4 U.S. time-zones: Pacific(P),
Mountain(M), Central (C) or Eastern (E)
D6 & D7. ALT (
Increases or decreases the value in compensational
altitude setting respectively
D8. [ RESET ] BUTTON
- Resets the unit by returning all setting to their default
values
) or ALT ( ) BUTTON
FEATURES : REMOTE
THERMO-HYGRO SENSOR
a. Two-line LCD
Displays the current temperature and humidity monitored
by the remote unit
b. LED indicator
Flashes when the remote unit transmits a reading
c.
°C/°F slide switch
Selects between Centigrade (°C) and Fahrenheit (°F)
d. Channel slide switch
Designates the remote unit Channel 1, Channel 2 or
Channel 3
e. RESET
Returns all settings to default values
f. Battery compartment
Accommodates two (2) pieces of UM-3 or AA-size batteries
4
g. Battery door
h. Wall-mount holder
Supports the remote unit in wall-mounting
i. Removable table stand
For standing the remote unit on a flat surface
BEFORE YOU BEGIN -
INSTALLING THE TABLE STAND
Before operation, plug
the detachable table stand
into the display unit as
shown.
You can rotate the display unit freely by moving the unit around.
NOTES ON OPERATION
For best operation:
1. Insert batteries for the main unit first. Then proceed with
inserting the batteries for the remote unit.
2. Position the remote unit and the main unit within effective
transmission range. In usual circumstances, the effective range
is up to 328 feet (100 meters).
3. Though the remote unit is weather resistant, it should be
placed away from direct sunlight, rain or snow.
BATTERY INSTALLATION: MAIN UNIT
1. Gently open the battery compartment door as shown.
2. Insert four (4) pieces of UM-3 or "AA" size batteries in
accordance with the polarities shown.
3. Close the battery compartment door.
5
GB
GB
BATTERY AND CHANNEL INSTALLATION:
REMOTE UNIT
The remote thermo-hygro sensor unit uses two (2) UM-3 or
“AA” size batteries.
Follow these steps to install / replace batteries:
1. Remove the screws on the battery compartment.
2. Select the channel number on the CHANNEL slide switch.
3. Select the temperature display unit on the °C/°F slide switch.
4. Insert the batteries strictly according to the polarities shown
therein.
5. Replace the battery compartment door and secure its screws.
Replace the batteries when the low-battery indicator of the particular channel lights up on the main unit.
Note: Once a channel is assigned to a remote unit, you can only
change it by removing the batteries or resetting the unit.
Standard Alkaline batteries contain signifcant amounts of water.
Because of this they will freeze in low temperatures of
approximately 10°F (-12°C). Disposable Lithium batteries have
a much lower threshold for temperature with an estimated freezing
range of below -40°F (-40°C). The Liquid Crystal Display in
outdoor thermometers will remain operational to -20°F (-28°C)
with adequate power.
Wireless ranges can be impacted by a variety of factors such as
extremely cold temperatures. Extreme cold may temporarily reduce
the effective range between the sensor and the base station. If the
unit's performance fails due to low temperature, the unit will
resume proper functioning as the temperature rises to within the
normal temperature range (i.e no permanent damage will occur
to the unit due to low temperatures).
LCD AND KEY-PANEL BACKLIGHT
For easy viewing in the dark this unit is featured with backlight
function on the LCD display as well as on the front key-panel.
The unit is designed such that you can conveniently use the
backlight feature irrespective of whether the unit is wall-mounted
or free standing on the table.