Oregon Scientific BAR688HGA User Manual

Wireless Weather Station with
Temperature / Humidity Display and
Self - Setting Atomic Clock
MODEL: BAR688HGA
INTRODUCTION
Thank you for selecting this Oregon Scientic
TM
NOTE Please keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specications and warnings you should know about.
CLOCK OVERVIEW
FRONT VIEW
1. SNOOZE
2. Weather Forecast Area
3. Outdoor Temperature Area
4. Indoor Temperature Area
5. Clock / Alarm Area
BACK VIEW
1. TEMP / HUMIDITY HI / LO : Change settings or
enable / disable hi or lo temperature / humidity alarm for channel 1
2. / : Increase / decrease setting; activate / deactivate
clock reception signal
LCD DISPLAY
Weather Forecast Area:
Outdoor Temperature Area:
1. Heat index icon
2. Hi / lo temperature alarm
3. Sensor reception icon
4. Sensor battery low
5. Max / min icon
6. Temperature display
7. Ice warning is active
8. Hi / lo humidity alarm
9. Temperature trend
10. Humidity trend
11. Humidity display
 
 
Indoor Temperature Area:
1. Internal sensor icon
2. Max / min icon
3. Temperature display
4. Temperature trend
5. Humidity trend
6. Humidity display
Clock / Alarm Area:
1. Alarm set
2. AM / PM icon
3. Clock signal reception
4. Low battery icon
5. Clock
6. Alarm mode icon
7. Moon phase
 
 
REMOTE SENSOR (THGR122N)
1. LED status indicator: Blinks red during data transmission
2. LCD screen
1. Wall mount hole
2. RESET hole
3. CHANNEL switch
4. Battery compartment
GETTING STARTED
SETTING UP THE CLOCK
Insert batteries before rst use, matching the polarity (+ and -). RESET after each battery change.
SENSOR DATA TRANSMISSION
indicates main unit batteries are low.
NOT E Do not u se rech arge able ba tteri es. We recommend that you use alkaline batteries with this product for longer usage and lit hium batteries in tempe ratures below freezing.
REMOTE SENSOR
The sensor collects temperature readings approx. every 40 seconds and sends them to the main unit. The main unit can collect data from up to 3 sensors.
To set up the sensor:
1. Remove the screws from the battery door.
2. Insert the batteries, matching the polarity (+ / -).
3. Select a channel. Make sure you use a different channel
for each sensor.
4. Place the sensor near the main unit. Press RESET on
the sensor.
5. Simultaneously press CHANNEL and MEM on the main
unit to initiate signal sending between the sensor and main unit.
6. Close the battery door and secure the screws
7. Place the sensor in the desired location using the table
stand or wall mount.
For best results:
Place the sensor out of direct sunlight and moisture.
Do not place the sensor more than 30 m (100 ft) from
the main (indoor) unit.
Position the sensor so that it faces the main (indoor)
unit, minimizing obstructions such as doors, walls, and furniture.
Place the sensor in a location with a clear view to the
sky, away from metallic or electronic objects.
Position the sensor close to the main unit during cold
winter months as below-freezing temperatu res may affect battery performance and signal transmission.
Data is sent from the sensor(s) every 40 seconds. The sensor reception icon in the remote sensor area shows the status.
ICON DESCRIPTION
and “- - . -“ (Outdoor temperature area)
The sensor cannot be found. Search for the sensor or check batteries
To search for a sensor:
Simultaneously, press and hold MEM and CHANNEL for 2 seconds.
NOTE If the sensor is still not found, check the batteries, obstructions, and remote unit location.
CLOCK
CLOCK RECEPTION
This product is designed to synchronize its date and time automatically once it is within range of the WWVB-60 signal from the atomic clock in Boulder, Colorado.
The sensor collects the radio signals whenever it is within 1500 km (932 miles) of a signal.
NOTE Initial reception takes 2-10 minutes for rst set up or when RESET is pressed. Once complete, the reception icon will stop blinking. If the signal is weak, it can take up to 24 hours to get a valid signal.
RECEPTION SIGNAL
To enable and force a signal search:
Press and hold for 2 seconds.
To disable the signal reception:
Press and hold for 2 seconds.
ashes when it is disabled.
STRONG SIGNAL WEAK SIGNAL NO SIGNAL
SET CLOCK
To manua lly set the clock m ake sure the clock signal reception is disabled.
1. Press and hold MODE for 2 seconds.
2. Select the US time zo ne (Paci c (P), Easter n (E), Central (C) and Moun tain (M)) , hour, minute, year, month, day and language. Press or to change the setting.
3. Press MODE to conrm.
NOTE The language options are English (E), German (D), French (F), Italian (I), and Spanish (S).
Press MODE to choose between the clock with seconds and clock with weekday display modes.
1. Pressure trend
2. Weather forecast
3. Comfort zone
4. Pressure icon
5. Altitude icon
6. Pressure / Altitude unit
7. UV index icon
USER MANUAL
3. CHANNEL: Switch remote sensor display
4. HEAT INDEX: Display heat index
5. MODE: Change settings / display
6. ALARM: View alarm status; set alarm
7. Battery compartment
8. MEM : Vi ew cu rren t, ma ximu m and min imum
temperature / humidity
9. PRESSURE: Select pressure unit; set altitude
10. °C / °F: Select temperature unit
11. RESET: Reset unit to default settings
The transmission range may vary depending on ma ny factors. You may need to experiment with various locations to get the best results.
Standard Alkaline batteries contain signicant amounts of water. Because of this they will freeze in low temperatures of appr oximat ely -12°C (1 0°F). Disp osable Li thium batteries have a much lower threshold for temperature with an estimated freezing range of below -30°C (-22°F).
Wireless ranges can be impacted by a variety of factors such as extremely cold temperatures. Extreme cold may temporarily reduce the effective range between the sensor and the base station. If the unit's performance fails due to low temperature, the unit will resume proper functioning as the temperature rises to within the normal temperature range (i.e. no permanent damage will occur to the unit due to low temperatures).
Sensor 1 is sending data
A channel has been found
Main unit is searching for the sensor(s)
Clock signal reception indicator:
BAR688HGA_M 2005.12.2, 2:53 PM1
P/N: 086L004255-016
© 2006 Oregon Scientic. All rights reserved.
SPECIFICATIONS
MAIN UNIT
TYPE DESCRIPTION
241 g (8.5 oz) without battery
117 x 80 x 171 mm (4.78 x 3.27 x 6.98 in)
°C / °F
0.1°C (0.2°F)
-5°C to 50°C (23°F to 122°F)
WWVB-60 (US)
Weight
L x W x H
Temperature unit
Resolution
Temperature range
Clock frequency Synchronization Signal frequency Clock Humidity range Humidity resolution MEM
Alarm duration Snooze Clock display
Hour format Calendar
Power
L x W x H
Weight
Transmission range
Auto or disabled 433 MHz Auto or manual (disabled) 25% - 95% 1% Min / Max relative humidity and
temperature
2 minutes 8 minutes HH:MM:SS
HH:MM: Day of Week 12 / 24 hour format MM / DD or DD / MM language selectable: E, D, F, I and S 3 x UM-3 (AA) 1.5 V batteries
92 x 60 x 20 mm (3.6 x 2.4 x 0.8 in)
62 g (2.22 ounces)
30 m (100 ft) unobstructed
REMOTE UNIT
Temperature Range
Power
-30°C to 60°C (-22°F to 140°F)
2 x UM-4 (AAA) 1.5 V batteries
NOTE We recomm end that you use alkali ne batterie s with this product for longer usage and lithium batteries in temperatures below freezing.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientic.com) to learn more about Oregon Scientic products such as digital cameras; MP3 players; children’s electronic learning products and games; projection clocks; health and tness gear; weather stations; and digital and conference phones. The website also includes contact information for our Customer Care department in case you need to reach us, as well as fre­quently asked questions and customer downloads.
We hope you will nd all the information you need on our website, however if you’re in the US and would like t o contact the Oregon Scientic Customer Care department directly, please visit: www2.oregonscientic.com/service/default.asp
OR
Call 1-800-853-8883.
For international inquiries, please visit: www2.oregonscientic.com/about/international.asp
FCC STATEMENT
This device complies with Part 15 of the F CC Rules . Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
This device complies with Part 15 of the F CC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This
device must accept any interference received, including interference that may cause undesired operation.
WARNI NG Changes or mo dificat ions not expr essly approved by the party responsible for compliance could void the user's authority to operate the equipment.
NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates , uses and can radiate radio freq uency en ergy and, if no t i nstall ed and used in accorda nce wi th the instru ctions, may cause harmful interfere nce to radio communication s. Howeve r, there is no guarante e tha t in terferenc e wil l no t occ ur i n a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment
and receiver.
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio / TV
technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientic.com), or on the wa rranty ca rd for this product) for a ll inquir ies instead.
We
Name: Oregon Scientic, Inc.
Addr ess: 19861 SW 95th Ave.,Tual atin,
Oregon 97062 USA
Telephone No.: 1-800-853-8883
declare that the product
Product No.: BAR688HGA
Product Name: Wireless Weather Station with
Temperature / Humidity Display
and Self - Setting Atomic Clock
Manufacturer: IDT Technology Limited
Address: Block C, 9/F, Kaiser Estate,
Phase 1,41 Man Yue St.,
Hung Hom, Kowloon,
Hong Kong
is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.
SET ALTITUDE
To ensure barometric readings are reliable set the altitude to reect distance from sea level at your position.
1. Press and hold PRESSURE for 2 seconds.
2. Use and to set the altitude in 10 m (33 ft) increments from 100 m (328 ft) to 2500 m (8202 ft).
3. Press PRESSURE to conrm.
WEATHER FORECAST
This product forecasts the next 12 to 24 hours of weather within a 30-50 km (19-31 mile) radius based on barometric pressure trend readings.
ICON DESCRIPTION
TEMPERATURE AND HUMIDITY
To toggle temperature unit:
Slide °C / °F to the desired setting. The setting for the main unit overrides the remote sensor setting.
MAXIMUM / MINIMUM RECORDS
To view records:
1. Press CHANNEL to select a sensor.
2. Press MEM to toggle maximum / minimum and current settings for the sensor selected.
To clear maximum and minimum records press and hold
MEM for 2 seconds.
ICE WARNING
If the channel 1 sensor falls between 3°C to –2°C (37°F to 28°F), ashes to warn you that the temperature is approaching freezing.
NOTE The warning will automatically stop if the temperature goes outside the ice-warning range.
TEMPERATURE, HUMIDITY AND PRESSURE TREND
The temperature, humidity and pressure trend icons are based on recent sensor readings.
RISING STEADY FALLING
To set alarm ON / OFF:
1. Press and hold TEMP / HUMIDITY HI / LO .
2. Use and to select high / low temperature / humidity
alarm. Press TEMP / HUMIDITY HI / LO to conrm.
3. Press / to set alarm ON / OFF and press TEMP / HUMIDITY HI / LO to conrm.
4. If alarm has been activated, use and to select the temperature / humidity.
5. Press TEMP / HUMIDITY HI / LO to conrm.
To silence the hi / lo alarm:
Press any key. The alarm resets automatically and will resound if the hi / lo temperature selected is recorded again.
HEAT INDEX
The heat index combines temperature and humidity data to describe the actual temperature felt.
Clear
Cloudy
Rainy
Partially Cloudy
WARNING HEAT INDEX MEANING
Extreme danger
Strong risk of dehydration / sun stroke
54.5°C / (130°F) or above
Danger
Heat exhaustion likely
40.5 - 54°C
(105 - 129°F) Extreme caution
Possibility of heat dehydration
32.2 - 40°C
(90 - 104°F)
Caution
Possibility of heat exhaustion
26.6 - 31.7°C
(80 - 89°F)
To display the heat index, press HEAT INDEX.
To toggle bet ween current / maximu m / minim um
readings, press HEAT INDEX, then press CHANNEL to select channel 1-3 or indoor, followed by MEM.
To toggle between temperature / humidity and heat index
display, press and hold HEAT INDEX for 2 seconds. Press HEAT INDEX again to stop this feature.
NOTE If the heat index is below 80°F / 26°C, or the desired channel is not working, the heat index will display NA .
COMFORT ZONE
The comfort zone assesses the climate based on current temperature and humidity measurements.
ICON TEMPERATURE HUMIDITY
> 70%Any
40 - 70%
20 - 25°C (68 - 77°F)
< 40%Any
MOON PHASE
When calendar is set press or to view the moon phase for the next / previous day.
Press and hold or to scan through the years (2001 to 2099).
Waxing Crescent
New Moon
Waxing Gibbous
First quarter
Full Moon
Last quarter
Waning Gibbous
Waning Crescent
RESET
Press RESET to return the unit to the default settings.
PRECAUTIONS
Thi s pro duct i s engi neer ed to g ive yo u year s of satisfactory service if you handle it carefully. Here are a few precautions:
Do n ot sub ject the un it to excess ive fo rce, shock, dust, temperat ure or humidi ty, which may r esult in malfun ction, shorter electro nic li fe sp an, da maged battery and distorted parts.
Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.
Do not clean th e u nit with abra sive or corr osive materials.
ALARM
To set the alarm:
1. Press and hold ALARM for 2 seconds.
2. Press / to set hour / minute.
3. Press ALARM or MODE to conrm. indicates alarm
is ON.
To toggle alarms ON / OFF:
1. Press ALARM to display alarm time
2. Press ALARM again to turn alarm ON / OFF.
To silence the alarm:
Press SNOOZE to silence it for 8 minutes OR
Press any key except SNOOZE to turn the alarm off
and activate it again after 24 hours.
BAROMETER
Barometer readings from the past 24 hours are stored by the main unit and used to provide weather forecast.
To select barometer measurement unit: Press PRESSURE to toggle between mb and inHg.
HI / LO TEMPERATURE /HUMIDITY ALARMS
Temperature and humidity alerts can be set to sou nd if sensor set to c hannel 1 rec ords above or bel ow a temperature/humidity of your choice.
Do not tamper with the unit’s int ernal com ponents. Doing so will invalidate the warranty on the unit and may cause unnecessary damage. The unit contains no user-serviceable parts.
Only use fr esh bat teries as spe cied in the user’s instructions. Do not mix new and old batteries.
Due to printing limitations, the displays shown in this manual may differ from the actual display.
The contents of this manual may not be reproduced without the permission of the manufacturer.
NOTE The technical specications for this product and the contents of the user manual are subject to change without notice.
BAR688HGA_M 2005.12.2, 2:53 PM2
Loading...