Oregon BAR610B User Manual

E N
1
Smart Weather Station
With auto-rotating screen
Model: BAR610P / BAR610PA /
BAR610PU
USER MANUAL
Overview ...................................................................2
Front view ..............................................................2
Back view ............................................................... 2
Remote sensor ......................................................3
Getting started .........................................................3
Main unit installation ..............................................3
Remote sensor installation ....................................3
Clock ......................................................................... 4
Clock reception ......................................................4
Manually set clock .................................................5
Alarm ........................................................................5
Weather forecast .....................................................6
Temperature ............................................................ 6
Projection .................................................................6
Auto-rotating screen ...............................................6
Backlight ..................................................................6
Reset ......................................................................... 6
Specifications ..........................................................
7
Precautions ..............................................................7
About Oregon Scientific .........................................
8
EU-Declaration of conformity ................................. 8
FCC Statement ......................................................... 8
BAR610P_M_EN_R3.indd 1 12/9/08 17:55:32
2
E N
OVERVIEW
FRONT VIEW
1 23 5 64
8 9
10
11 12 13 14
15
7
1. : Main unit batteries low / no battery
2. : 12 hour clock
3. : Indicate daily alarm is On
4. Projector: Project time / outdoor temperature
5. Alarm time
6. : Radio controlled clock reception icon
7. Clock
8. Time zone offset
9. : 12 hour clock
10. Weather forecast
11. : Outdoor remote sensor battery low
12. : Indicate outdoor sensor reception status
13. Indicate outdoor channel selected
14. Outdoor temperature
15. Indoor temperature
BACK VIEW
1 2 5 7 8
9
10
12
13
14
11
643
S N OO
Z E
1. CLOCK SET: Set clock
2. ALARM SET: View alarm status / set alarm (only when ALARM ON-OFF is switched to ON)
3. UP / DOWN: Decrease / increase value of the setting; enable / disable clock reception; initiate sensor search
4. CHANNEL: Toggle display of 5 outdoor channel’s temperature recording; activate / deactivate auto­toggle display of temperature from 5 different outdoor channels
5. FOCUS Wheel: Adjust projection focus
6. PROJECTION DIRECTION Wheel: Adjust projection direction
7. PROJECTION ON - OFF: Turn projection On / Off
8. ALARM ON – OFF: Activate / deactivate alarm function
9. SNOOZE: Activate snooze alarm; turn on backlight;
BAR610P_M_EN_R3.indd 2 12/9/08 17:55:39
E N
3
flip projected image 180°
10. °C / °F: Select temperature unit
11. Battery compartment
12. RESET: Reset unit to default settings
13. AC/DC Adaptor socket
14. Wall mount holes
REMOTE SENSOR
FRONT VIEW BACK VIEW
1
2
3
4
5
6
1. RESET: Reset unit to default settings
2. EU / UK Switch (RTHN318D sensor only)
3. Channel Switch
4. Double sided adhesive tape
5. Wall mount hole
6. Battery compartment
GETTING STARTED
MAIN UNIT INSTALLATION
For continuous use of projector, install adapter.
• Plug AC/DC adaptor into socket. Make sure the adapter is not obstructed and is easily accessible to the unit.
To completely disconnect from power, the adapter should be disconnected from the main unit.
NOTE The main unit and adapter should not be exposed to wet conditions. No objects filled with liquid, such as vases, should be placed on the main unit and adapter.
Insert batteries:
1. Remove the battery compartment cover.
2. Insert the batteries, matching the polarities.
NOTE Batteries should not be exposed to excessive heat such as sunshine or fire.
REMOTE SENSOR INSTALLATION
1. Slide open the battery door.
2. Slide channel switch to channel 1.
3. Select
EU/UK. (RTHN318D only)
4. Insert the battery, matching the polarities (+ / -).
5. Press RESET after each battery change.
6. Close the battery door.
7. Press and hold
UP and DOWN on main unit
BAR610P_M_EN_R3.indd 3 12/9/08 17:55:44
4
E N
to initiate search and start receiving time and temperature data from the sensor.
The sensor reception icon shows the status:
ICONS MEANING
Main unit is searching for sensor(s)
A sensor channel has been found and logged on
No sensor found
NOTE After every sensor initialisation, the main unit may take up to 30 minutes to receive the time from the sensor.
8. Secure the sensor in the desired location using the wall mount hole or double sided adhesive tape.
For best results:
• Place the sensor within 30 m (100 ft) of the main unit.
• Place the sensor out of direct sunlight and moisture.
• Position the sensor so that it faces the main unit, minimizing obstructions such as doors, walls and furniture.
• Place the sensor in a location with a clear view to the sky, away from metallic / electronic objects.
• Position the sensor close to the main unit during cold winter months as below-freezing temperatures may affect battery performance and signal transmission.
TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results. NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing.
CLOCK
CLOCK RECEPTION
This product is designed to synchronize its clock automatically with a clock signal received from provided remote sensor.
To enable / disable signal reception:
Press and hold
UP to enable or DOWN to disable
signal reception.
BAR610P_M_EN_R3.indd 4 12/9/08 17:55:46
E N
5
NOTE Reception takes 2-10 minutes. If the signal is weak, it can take up to 24 hours to get a valid signal.
Clock signal reception indicator:
STRONG SIGNAL WEAK / NO SIGNAL
NOTE Clock reception is dependent on the successful
transmission of data from remote sensor.
If is
displayed, press
RESET on sensor and press UP and
DOWN together on the main unit and ensure sensor
has been successfully logged.
MANUALLY SET CLOCK
To set the clock manually, disable the clock signal reception first.
1. Press and hold CLOCK SET.
2. Press
UP / DOWN to change the settings.
3. Press CLOCK SET to confirm.
The settings order is: time zone, 12/24 hr format, hour, minute.
BAR610P / BAR610PU
: Time zone offset sets the
clock +/- 23 hours from the received clock signal time.
NOTE If you enter + 1 in the time offset setting, this will give you your local time plus one hour. If you are in the
US (BAR610PA only) set the clock to:
0 for Pacific time +1 for Mountain time +2 for Central time +3 for Eastern time
ALARM
To set the alarm:
1. Slide
ALARM ON-OFF switch to ON.
2. Press and hold ALARM SET.
3. Press UP / DOWN to change the settings.
4. Press ALARM SET to confirm.
indicates alarm is on.
To activate / deactivate alarm:
• Slide ALARM ON-OFF switch to ON / OFF.
To silence the alarm:
Press SNOOZE to silence it for 8 minutes OR
Press any key to turn the alarm off and activate it
again after 24 hours.
BAR610P_M_EN_R3.indd 5 12/9/08 17:55:47
6
E N
WEATHER FORECAST
This product forecasts the next 12 to 24 hours of weather within a 30-50 km (19-31 mile) radius with a 75% accuracy.
Sunny
Partially Cloudy
Cloudy
Rainy
TEMPERATURE
To toggle temperature unit:
• Press
°C / °F.
PROJECTION
This unit projects time and outdoor temperature information for your convenience.
For continuous projection:
• Slide PROJECTION switch to ON when adaptor is connected, to enable / disable.
To project time and temperature:
Press SNOOZE when PROJECTION switch is in OFF mode.
To deactivate projection:
Slide PROJECTION switch to OFF mode.
To rotate image:
Turn PROJECTION DIRECTION wheel.
To flip projected image by 180°:
Press SNOOZE twice.
To focus image:
Turn FOCUS wheel.
NOTE If projection is illuminated, do not look directly
into the projector.
AUTO-ROTATING SCREEN
This special feature gives the user the choice of placing the unit horizontally or vertically (3 dimensional options) to suit user’s living environment and accommodate individual style.
BACKLIGHT
To activate backlight:
• Press
SNOOZE.
RESET
Press RESET to return to the default settings.
BAR610P_M_EN_R3.indd 6 12/9/08 17:55:49
E N
7
SPECIFICATIONS
MAIN UNIT
TYPE DESCRIPTION
L x W x H 194 x 136 x 49 mm
(7.71 x 5.35 x 1.93 in)
Weight 670g (23.63 oz) without battery
Power 6V AC adaptor
3 x UM-4 (AAA) 1.5V batteries
REMOTE RF CLOCK THERMO SENSOR
TYPE DESCRIPTION
L x W x H 64 x 25 x 98 mm
(2.52 x 0.98 x 3.86 in)
Weight 80 g (2.8 oz) without battery
Temperature range -20°C to 60°C (-4°F to 140°F)
Resolution 0.1°C (0.2°F)
Signal frequency 433 MHz
Transmission range
30 m (98 ft) unobstructed
No. of channels 5
Power 1 x UM-3 (AA) 1.5 V batteries
PRECAUTIONS
• Where there is excess electrostatic discharge, the unit may reset itself to default settings. User will be required to set the unit again.
• Do not subject the unit to excessive force, shock, dust, temperature or humidity.
• Do not cover the ventilation holes with any items such as newspapers, curtains etc.
• Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.
• Do not clean the unit with abrasive or corrosive materials.
• Do not tamper with the unit’s internal components. This invalidates the warranty.
• Only use fresh batteries. Do not mix new and old batteries.
• Images shown in this manual may differ from the actual display.
• When disposing of this product, ensure it is collected separately for special treatment and not as normal household waste.
• Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer’s care instructions for information.
• The contents of this manual may not be reproduced without the permission of the manufacturer.
• Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
BAR610P_M_EN_R3.indd 7 12/9/08 17:55:49
8
E N
• Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use.
NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice.
NOTE Features and accessories will not be available in all countries. For more information, please contact your local retailer.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. If you’re in the US and would like to contact our Customer Care department directly, please visit: www2.oregonscientific.com/service/support.asp For international inquiries, please visit: www2.oregonscientific.com/about/international.asp
EU-DECLARATION OF CONFORMITY
Hereby, Oregon Scientific, declares that this Smart Weather Station With auto-rotating screen (Model: BAR610P / BAR610PA / BAR610PU) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service.
COUNTRIES RTTE APPROVAL COMPLIED
All EU countries, Switzerland
and Norway
CH
N
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
BAR610P_M_EN_R3.indd 8 12/9/08 17:55:50
E N
9
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment
and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio / TV technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for support or sales. Please visit our website at
www2.
oregonscientific.com/service
for all enquiries.
We
Name: Oregon Scientific, Inc. Address: 19861 SW 95th Ave.,Tualatin, Oregon 97062 USA Telephone No.: 1-800-853-8883
declare that the product
Product No.: BAR610P / BAR610PA / BAR610PU Product Name: Smart Weather Station
With auto-rotating screen Manufacturer: IDT Technology Limited Address: Block C, 9/F, Kaiser Estate, Phase 1, 41 Man Yue St., Hung Hom, Kowloon, Hong Kong
is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired operation.
BAR610P_M_EN_R3.indd 9 12/9/08 17:55:50
Loading...