Oregon Scientific BAR321HGA, BAR323HGN, BAR321HGN User Manual

Page 1
Talking Wireless Weather Station
Model: BAR321 / 323HGN
User Manual
BAR321/323HGN EN New C R2 OP 8/17/04, 12:56 PM1
Black
Page 2
EN
1
Contents ................................................................... 1
Introduction .............................................................. 3
Product Overview .................................................... 4
LCD Screen ........................................................... 4
Front View .............................................................. 5
Back View .............................................................. 6
Remote Sensor (RTGR328N) ................................ 7
Getting Started ......................................................... 8
Batteries ................................................................. 8
AC Adapter (Main Unit) .......................................... 8
Wall Mount / Stand ................................................ 9
Change Settings .................................................... 9
Remote Sensor .......................................................10
Thermo / Hygro Sensor Setup (RTGR328N) .......10
Clock .................................................................... 11
Set Radio Signal Format ...................................... 11
Sensor Data Transmission .................................. 11
Sensor Search ..................................................... 12
Clock and Calendar ............................................... 12
Radio-Controlled Clock ........................................12
Turn Radio-Controlled Clock ON/OFF .................12
Set Clock ............................................................. 13
Alarms ..................................................................... 13
Set Daily Alarm .................................................... 13
Set Pre-Alarm ...................................................... 14
Activate Alarm ...................................................... 14
Snooze ................................................................ 15
Barometer ............................................................... 15
View Barometer Area ........................................... 15
Select Measurement Unit .................................... 15
View Barometer History ....................................... 16
Bar Chart Display ................................................. 16
Set Altitude........................................................... 16
Weather Forecast ................................................... 16
Weather Forecast Icons ....................................... 16
UV Measurement (with optional UVR138) ............17
Temperature and Humidity .................................... 17
View Temperature and Humidity Area ................. 17
Select Measurement Unit .................................... 17
Select Sensor Channel ........................................ 18
Minimum / Maximum Records ............................. 18
Temperature and Humidity Trend ........................ 18
Comfort Zone .......................................................18
Talking Wireless Weather Station
Model: BAR321 / 323HGN
User Manual
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM1
Black
Page 3
EN
2
Audio Broadcast .................................................... 19
Activate Audio Broadcast ..................................... 19
Broadcast Current Time, Temperature, Humidity
and weather forecast ........................................... 19
Set Broadcast Times ........................................... 19
Set Volume Level ................................................. 20
Backlight ................................................................. 20
Reset System ......................................................... 20
Safety and Care ...................................................... 20
Warnings .................................................................20
Troubleshooting .....................................................21
Specifications .........................................................22
Main unit dimensions ........................................... 22
Remote unit dimensions ...................................... 22
Temperature ......................................................... 22
Relative humidity ................................................. 22
Barometer ............................................................ 22
Remote unit (RTGR328N) ................................... 22
Radio controlled clock ......................................... 23
Power ................................................................... 23
About Oregon Scientific ........................................ 23
EC Declaration of Conformity ............................... 24
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM2
Black
Page 4
EN
3
INTRODUCTION
Thank you for selecting the Oregon Scientific™ BAR321HGN/BAR323HGN Talking Wireless Weather Station. This powerful device bundles time keeping, weather monitoring, and audio broadcast features into a single tool you can use from the convenience of your home.
In this box, you will find:
• Main unit
• Remote sensor (RTGR328N)
• Optional UV sensor (UVR138)
• AC adapter
• Batteries
BAR321HGN --- BAR321HGN Main unit + RTGR328N Remote sensor
BAR323HGN --- BAR321HGN Main unit + RTGR328N Remote sensor + UVR138 UV Sensor
Keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know.
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM3
Black
Page 5
EN
4
1
2
3
4
PRODUCT OVERVIEW
LCD SCREEN
1. Weather Forecast Area: Animated weather forecast
2. Clock / Alarm / Calendar Area: Radio controlled clock; alarms; calendar; battery status
3. Temperature / Humidity / Comfort Zone Area: Readings and trend lines; comfort zone; sensor channel number; sensor battery status
4. UVI / Barometer Area: UV level and barometric pressure bar chart; UV Index and barometric readings; AC adapter icon; audio broadcast icon
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM4
Black
Page 6
EN
5
1
2
3
4
5
6
7
8
9
10
FRONT VIEW
1. SNOOZE / LIGHT – activate 8-minute snooze or backlight
2. LCD Display
3. SELECT – switch Areas
4. MODE – change settings / display
5. UP – increase setting / activate radio-controlled clock and audio broadcast
6. DOWN – decrease setting / deactivate radio- controlled clock and audio broadcast
7. ALARM /
-- view alarm status; set alarm
8. MEMORY – view current and saved temperature and humidity readings
9. CHANNEL – switch remote sensor
10. HISTORY – view historical barometer and UV readings
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM5
Black
Page 7
EN
6
BACK VIEW
1. Speakers
2. Slot for wall mount / stand
3. Battery compartment (bottom)
4. °C / °F button (in battery compartment)
5. mb / inHg button (in battery compartment)
6. RESET button (in battery compartment)
GETTING STARTED
Refer to the Battery section ( 8) for more
information about the battery compartment.
NOTE
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM6
Black
Page 8
EN
7
REMOTE SENSOR (RTGR328N
)
1
2
3
1. LCD display
2. LED Status indicator
3. Ventilation duct
1. Signal reception
2. Channel number
3. Low battery icon
4. Time
5. Temp (°C or °F)
6. Humidity %
7. Temp / Humidity
1. Wall mount
2. Channel switch (1 – 5)
3. RESET
4. °C / °F
5. Search
6. EU / UK radio signal format switch
7. Battery compartment
8. Fold-out stand
1
2 3 4 5 6
7
8
1
4
5
6
7
2
3
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM7
Black
Page 9
EN
8
Do not use rechargeable batteries.
shows when batteries are low.
GETTING STARTED
BATTERIES
Insert batteries before first use, matching the polarity as shown in the battery compartment. For best results, install batteries in the remote sensor before the main unit. Press RESET after each battery change.
NOTE
UNIT
LOCATION Main Calendar Area
Remote Humidity Area
UV Sensor
UVI / Barometric Measurement Area
To open the battery compartment:
1. Insert a coin in the slot. Gently press back until the battery compartment pops out of place.
2. Grasp the battery compartment by the sides and gently pull to open. It will not completely detach from the main unit.
AC ADAPTER (MAIN UNIT
)
The AC power adapter socket is located inside the battery compartment of the main unit. Batteries are for back-up purposes only; adapter is required for Audio Broadcast.
shows in the UVI / Barometric Measurement
Area when AC adapter is not plugged in.
To plug in the AC Adapter:
1. Open the battery compartment.
2. Plug the jack in the power socket.
3. Wrap the power cord under the prongs to guide it out of the battery compartment.
4. Close the battery compartment.
5. Plug the other end of the Adapter into a wall socket to power it on.
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM8
Black
Page 10
EN
9
CHANGE SETTINGS
1. Press SELECT to switch between Areas.
indicates
the selected Area.
2. Most Areas have alternate display options (for example, Clock / Alarm or Barometer / UVI). Press MODE to switch options, or ALARM /
to switch
between Clock and Alarm.
3. Press and hold MODE for 2 seconds to enter setting MODE.
4. Press UP or DOWN to change settings.
5. Press MODE to confirm.
WALL MOUNT / STAND
To attach the wall mount or stand, slide the insertion rod into the slot on the back of the main unit.
Wall Mount
Stand
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM9
Black
Page 11
EN
10
REMOTE SENSOR
This product is shipped with the RTGR328N Thermo/ Hygro Sensor and an optional UVR138 Ultraviolet Sun Ray Sensor (BAR323HGN only). The main unit can collect data from up to 6 sensors (5 Thermo/Hygro Sensors and 1 UV Sensor). Additional sensors sold separately.
The RTGR328N Sensor collects temperature and humidity readings, and signals from official time-keeping organizations for the radio-controlled clock.
For information about the UVR138, refer to the UVR138 User Manual.
THERMO / HYGRO SENSOR SETUP (RTGR328N)
1. Open the battery compartment with a small Phillips screwdriver.
2. Insert the batteries.
3. Set the channel and radio signal format. The switches are located in the battery compartment.
SWITCH
OPTION
Channel
Channel 1 – 5. If you are using more than one sensor, select a different channel for each sensor.
EU (DCF) / UK (MSF)
Radio Signal Format
4. Press RESET. Then set the temperature unit.
5. Close the battery compartment.
6. Secure the sensor with the wall mount or using the fold-out stand.
FOLD OUT STAND
SWITCH OPTION
Temp °C / °F
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM10
Black
Page 12
EN
11
For best results:
• Insert the batteries and select the unit, channel, and radio signal format before you mount the sensor.
• Place the sensor out of direct sunlight and moisture.
• Do not place the sensor more than 70 meters (230 feet) from the main (indoor) unit.
• Position the sensor so that it faces the main (indoor) unit, minimizing obstructions such as doors, walls, and furniture.
• Place the sensor in a location with a clear view to the sky, away from metallic or electronic objects.
The transmission range may vary and is subject
to the receiving range of the main unit.
You may need to experiment with various locations to get the best results.
CLOCK
This remote sensor can automatically synchronize the date and time with official time-keeping organizations in Frankfurt (Germany) and Rugby (England). When the sensor is within 1500 km (932 miles) of a RF signal, the reception icon will blink during reception.
When the sensor receives the radio-controlled clock signal and is paired with the main unit, the clock in the main unit will be automatically updated.
NOTE
STRONG
SIGNAL
WEAK OR NO
SIGNAL
SET RADIO SIGNAL FORMAT
The RADIO SIGNAL FORMAT switch is located inside the battery compartment. Select EU (DCF) or UK (MSF). Then, press RESET.
Reception takes 2 – 10 minutes to complete. Once complete, the icon will stop blinking.
To force a manual RF clock reception, press and hold
SEARCH for 2 seconds.
SENSOR DATA TRANSMISSION
Data is sent from the sensor(s) every 60 seconds. The reception icon shown in the Temperature / Humidity Area indicates the status.
--- shows in Temp / Humidity Area
ICON
DESCRIPTION
Main unit is searching for sensors.
At least 1 channel has been found.
Sensor 1 is sending data. (The number shows which sensor is selected.)
The selected sensor cannot be found. Search for the sensor or check batteries.
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM11
Black
Page 13
EN
12
SENSOR SEARCH
To search for a Thermo / Hygro sensor, press SELECT to navigate to the Temperature/ Humidity / Comfort Zone Area.
will show next to the Area. Then, simultaneously
press and hold MEMORY and CHANNEL for 2 seconds.
To search for the UV sensor, press SELECT to navigate to the UVI / Barometer Area.
will show next to the Area. Then, press and hold MEMORY and CHANNEL for 2 seconds.
If the sensor is still not found, check the
batteries.
CLOCK AND CALENDAR
This product tracks the time and date based on radio­controlled signals from the RTGR328N remote sensor, or manual settings that you enter.
NOTE
RADIO-CONTROLLED CLOCK
The time and date are automatically updated by radio­controlled clock signals from official time-keeping organizations in Frankfurt (Germany) and Rugby (England) unless you disable this feature. The signals are collected by the remote sensor (RTGR328N) whenever it is within 1500 km (932 miles) of a signal.
Initial reception takes 2 – 10 minutes, and is initiated when you first setup the unit, and whenever you press RESET. Once complete, the reception icon will stop blinking.
The
icon shown in the Clock Area indicates 2 factors:
• Connection between the main unit and the sensor that collects RF signals (
)
• RF signal reception (
)
Both parts will show (
) when the sensor that receives RF signals is selected and the RF signal is strong. (If you select another sensor,
or
will show to indicate
whether the RF signal is strong.)
If no signal is found, check the sensor batteries.
TURN RADIO-CONTROLLED CLOCK ON/OFF
If you wish to manually set the clock, you must first disable the radio-controlled feature. To do this, navigate to the Clock / Alarm Area. Then, press and hold DOWN on the main unit for 2 seconds. To enable it, navigate to the Clock / Alarm Area, then press and hold UP for 2 seconds.
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM12
Black
Page 14
EN
13
The house icon indicates that the radio-controlled clock is ON. No icon means that it is OFF.
SET CLOCK
You only need to do this if you have disabled the radio­controlled clock, or if you are too far from a RF signal.
1. Press SELECT to navigate to the Clock Area. will show next to the Area.
2. Press and hold MODE for 2 seconds.
3. Select the 2
nd
time zone offset hour (+/-23 hours), 12/ 24 hour format, hour, minute, year, date/month format, month, date, and display language, and (optional) volume level for the Audio Broadcast. Press UP or DOWN to change the setting. Press MODE to confirm.
The language options are (E) English, (F) French, (D) German, (I) Italian, and (S) Spanish. The language you select determines the weekday display and the spoken language for the Audio Broadcast.
Audio Broadcast must be activated ( 19) before you can set the volume level. The number of bars shown after the speaker icon (
) at the BOTTOM of
the display indicates the level (Low, Medium, or High).
ALARMS
This product has 2 alarms: the Daily Alarm and a Pre­Alarm for snowy weather. The Daily Alarm can be set to go off at the same time every day and you can select either Beep or Talking Alarm. The Pre-Alarm sounds only when the Daily Alarm is activated and the recorded temperature from Channel 1 Sensor falls to 2° C (35.6 °F) or below.
SET DAILY ALARM
1. Press SELECT to navigate to the Clock Area.
will
show next to the Area.
2. Press ALARM /
to view the Alarm. (AL will show
at the top.)
3. Press and hold ALARM /
for 2 seconds.
4. Select the hour and minute. Press UP or DOWN to
change settings. Press ALARM /
to confirm.
NOTE
NOTE
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM13
Black
Page 15
EN
14
5. The beep alarm icon
or talking alarm icon will flash. Press UP or DOWN to confirm the alarm mode. Press ALARM /
to confirm.
or
shows when the Alarm is set.
The AC Adapter must be connected for the Talking Alarm to work. If you select Talking Alarm, and the Adapter is not plugged in at the alarm time, the Beep Alarm will sound.
SET PRE-ALARM
The Pre-Alarm can be set to sound 15,30,45, or 60 minutes before the Daily Alarm. It will sound whenever the recorded temperature from Channel 1 Sensor falls to 2°C (35.6°F) or below.
For example, if you set the Alarm to 7:00 AM, and the Pre-Alarm to 45 minutes, the Pre-Alarm will sound at 6:15 AM provided the outdoor temperature at Channel 1 Sensor is 2°C or below.
1. Set up and activate the Daily Alarm.
2. Press ALARM /
to switch to Pre-Alarm view.
(
will show at the top.)
3. Press and hold ALARM /
for 2 seconds.
NOTE
4. Press UP or DOWN to select 15, 30, 45 or 60 minutes. This is the amount of time the Pre-Alarm will sound BEFORE the Daily Alarm. The Pre-Alarm is automatically activated when you select a time.
5. Press ALARM /
to confirm.
shows when the Pre-Alarm is set.
The daily Alarm will NOT function until the next day once if the Pre-Alarm has been triggered. Also, if you deactivate the Alarm, the Pre-Alarm is automatically deactivated.
ACTIVATE ALARM
Navigate to the Clock Area, then press ALARM /
to switch to Daily Alarm or Pre-Alarm view. To activate or deactivate the alarm, press UP or DOWN.
When the Alarm time is reached, the crescendo alarm will sound for 2 minutes. Press any key to silence the alarm. It will sound at the same time the next day.
NOTE
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM14
Black
Page 16
EN
15
SNOOZE
Press SNOOZE / LIGHT to temporarily disable the Alarm
for 8 minutes.
, ,
or will blink while Snooze is on.
BAROMETER
This product tracks fluctuations in barometric pressure to provide the weather forecast (
16), and the current and past 24 hours barometric pressure history Measurements are recorded by the main (indoor) unit.
ICON DESCRIPTION
Daily Talking Alarm is activated and will broadcast the current time at the set time.
Daily Beep Alarm is activated and will sound at the set time.
Pre-Alarm is activated and will sound at the specified time if the temperature falls to 2°C (35.6 °F) or below.
Alarm is not activated and will not sound.
VIEW BAROMETER AREA
Press SELECT to navigate to the Barometer Area.
If
is NOT shown, press MODE.
Barometric data is shown in 2 areas at the bottom of the display. The upper area shows a 24-hour bar chart. The lower area shows current and historical readings.
SELECT MEASUREMENT UNIT
Press mb / inHg on the bottom of unit.
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM15
Black
Page 17
EN
16
VIEW BAROMETER HISTORY
Navigate to the Barometer Area, then press HISTORY repeatedly to scroll through the measurements. The number shown in the HR box indicates how long ago each measurement was taken (e.g., 2 hours ago, 3 hours ago, etc.).
BAR CHART DISPLAY
The bar chart visually shows atmospheric changes from the current hour (0) to 24 hours prior (-24).
SET ALTITUDE
Set the altitude to match how far above or below sea level you are living. This ensures that the barometric pressure readings are accurate.
1. Navigate to the Barometer Area.
2. Press and hold HISTORY for 2 seconds.
3. Press UP or DOWN to set the altitude in 10-meter increments (-100m to 2500m).
4. Press HISTORY to confirm.
WEATHER FORECAST
This product forecasts the next 12 to 24 hours of weather within a 30 – 50 km (19 – 31 mile) radius. The forecast is based on barometric pressure trend readings.
The top area shows an animated icon indicating the forecasted weather.
WEATHER FORECAST ICONS
ICON DESCRIPTION
DAY / NIGHT
CLEAR
DAY / NIGHT
PARTLY CLOUDY
CLOUDY
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM16
Black
Page 18
EN
17
The nighttime icon displays from 6 PM to 6 AM. When the Channel 1 sensor records a temperature of 2°C (35.6 °F) or lower, the RAINY icon becomes SNOWY.
UV MEASUREMENT (WITH OPTIONAL UVR138)
With the optional UVR138 Ultra-Violet Radiation Sensor, the following information is at your fingertips:
10-hour Ultra-violet index (UVI) record
Automatic calculation of acceptable UV
exposure times based on pre-set user profiles (4 users maximum)
UVI Danger Alert when UV index reaches unsafe levels
UV data is shown in the same area as the Barometer. Press SELECT to navigate to the Barometer Area, then
press MODE to display the
UV icon and data. Refer
to the UVR138 User Manual for more information.
NOTE
RAINY
SNOWY
ICON DESCRIPTION
TEMPERATURE AND HUMIDITY
The weather station can display the following information from any of the 5 remote sensors:
Current, minimum, and maximum temperatures and relative humidity percentages.
Comfort level indicator and trend line (rising, falling, or steady).
Data is collected and displayed every 60 seconds.
VIEW TEMPERATURE AND HUMIDITY AREA
Press SELECT to navigate to the Temperature and Humidity Areas.
Temperature data is given at the top; Humidity
is below.
SELECT MEASUREMENT UNIT
Press °C / °F on the bottom of unit.
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM17
Black
Page 19
EN
18
SELECT SENSOR CHANNEL
Press CHANNEL to switch between sensors 1 - 5.
The house icon shows the selected remote sensor.
To auto-scan between sensors, press and hold CHANNEL for 2 seconds. Each sensor’s data will be displayed for 3 seconds. To end auto-scan, press CHANNEL and MEMORY with the Temperature / Humidity Area selected.
If you select a sensor that collects only
temperature data, the humidity will not be shown.
MINIMUM / MAXIMUM RECORDS
Press MEMORY repeatedly to view current, maximum and minimum records for the selected sensor. To clear the records, press and hold MEMORY for 2 seconds.
A beep will sound to confirm that the memory has been cleared.
TEMPERATURE AND HUMIDITY TREND
The trend lines are shown next to the Temperature and Humidity readings.
NOTE
TREND RISING STEADY FALLING
ICON
COMFORT ZONE
The Comfort Zone indicates how comfortable the climate is, based on current temperature and humidity measurements.
ZONE TEMPERATURE HUMIDITY
Any
>70%
20 – 25 ° C (68 - 77 ° F)
40 – 70%
<40%
Any
This information is shown in the Humidity Area when the current measurement is displayed.
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM18
Black
Page 20
EN
19
AUDIO BROADCAST
This product can broadcast the current time, indoor temperature, humidity level and weather forecast. When activated, the product can tell you this information on the hour for a specified period of time (such as 6 – 10PM nightly), or once every 24 hours.
The Audio Broadcast language is selected when you set the clock (
13).
ACTIVATE AUDIO BROADCAST
Plug in the AC power adapter (it must be plugged in for the feature to work).
displays in the UVI / Barometric Pressure Area
when Voice Recognition is ON.
To deactivate Audio Broadcast any time, unplug the AC power adapter.
BROADCAST CURRENT TIME, TEMPERATURE, HUMIDITY AND WEATHER FORECAST
Press SNOOZE / LIGHT for 2 seconds. Audio Broadcast must be activated for the feature to work.
SET BROADCAST TIMES
There are 2 Broadcast settings: Hourly during a specified period of time (such as 6 – 8 PM nightly), or daily at 24 hour intervals.
The AC Adapter must be connected for this
feature.
1. Press SELECT to navigate to the Clock Area.
2. Press and hold MODE for 2 seconds to enter the clock setting mode.
3. After setting the language, select 1 hour or 24 hour broadcast mode. Press UP or DOWN to change settings. Press MODE to confirm.
4. When 1-hour mode is selected, you can set the start/ end times. Press UP or DOWN to change settings. Press MODE to confirm.
5. When 24-hour mode is selected, your can set the start times. Press UP or DOWN to change settings. Press MODE to confirm.
NOTE
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM19
Black
Page 21
EN
20
OPTION
DESCRIPTION
1 Hour
The Broadcast will sound once hourly between the specified times. For example, if you selected 6 PM as the start time, and 8 PM as the end time, the Broadcast will sound at 6PM, 7PM, and 8PM.
24 Hour
The Broadcast will sound once a day at the selected start time
SET VOLUME LEVEL
After setting the broadcast mode, you can set the volume level. There are 3 volume levels: Low, Medium and High. The levels are set in Clock Mode after you select the broadcast times.
BACKLIGHT
Press SNOOZE / LIGHT to illuminate the backlight for 5 seconds.
RESET SYSTEM
The RESET button is located at the bottom of the unit. Press RESET when you change the batteries and whenever performance is not behaving as expected (for example, unable to establish radio frequency link with remote unit or radio-controlled clock).
When you press RESET, all settings will return
to default value, and you will lose all stored information.
SAFETY AND CARE
Clean the unit with a slightly damp cloth and alcohol­free mild detergent. Avoid dropping the unit or placing it in a high-traffic location.
WARNINGS
This product is designed to give you years of service if handled properly. Observe the following guidelines:
Never immerse the unit in water. This can cause electrical shock and damage the unit.
Do not subject the main unit to extreme force, shock, or fluctuations in temperature or humidity.
Do not tamper with the internal components.
NOTE
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM20
Black
Page 22
EN
21
Do not mix new and old batteries or batteries of different types.
Do not use rechargeable batteries with this product.
Remove the batteries if storing this product for a long period of time.
Do not scratch the LCD display.
Do not make any changes or modifications to this product. Unauthorized changes may void your right to use the product. The technical specifications of the product and contents of this user guide are subject to change without notice. Images not drawn to scale.
TROUBLESHOOTING
Check here before contacting our customer service department.
Problem Symptom Remedy
Barometer
Strange readings
Set altitude / unit
Calendar
Strange date / month
Change language
Clock
Cannot adjust clock
Disable radio-controlled clock
Problem Symptom Remedy
Audio broadcast
Does not work
Is the AC adapter plugged in?
Cannot auto­synch
1. Adjust batteries.
2. Press RESET
3. Manually activate radio-controlled clock-
Cannot change channel
Check sensors. Only one sensor is working
Check batteries
Check location
Temp Shows “LLL”
or “HHH”
Temperature is out-of­range
Remote sensor
Cannot locate remote sensor
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM21
Black
Page 23
EN
22
SPECIFICATIONS
MAIN UNIT DIMENSIONS
L x W x H 87 x 209 x 45 mm
(3.43 x 8.23 x 1.77 inches)
Weight 314 grams (0.69 lbs) with
battery
REMOTE UNIT DIMENSIONS
L x W x H 70 x 24.5 x 116mm
(2.76 x 0.96 x 4.57 inches)
Weight 156 grams (0.34lb.) with
battery
TEMPERATURE
Unit °C or °F
Indoor Range -5 °C to 50 °C
(23 °F to 122 °F)
Outdoor Range -20 °C to 60 °C
(-4 °F to 140 °F)
Resolution 0.1 °C (0.2° F)
Comfort 20 °C to 25 °C
(68 °F to 77 °F)
Memory Min / Max
Trend +/- 5° (°C or °F)
RELATIVE HUMIDITY
Range 25% to 95%
Resolution 1%
Comfort 40% to 70%
Memory Min / max
Trend +/- 3%
BAROMETER
Unit mb/hPa or inHg
Range 500 to 1050 mb
(14.77 to 31.01 inHg)
Resolution 1 mb (0.03 inHg)
Altitude -100 to 2500 meters
(-328 to 2734 feet)
Display Sunny, partly cloudy,
cloudy, rainy, snowy
REMOTE UNIT (RTGR328N)
RF frequency 433 MHz
Range up to 70 meters
(230 feet) with no obstructions
Transmission every 1 minute
Channel No. 1, 2, 3,4 or 5
Unit °C or °F
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM22
Black
Page 24
EN
23
RADIO CONTROLLED CLOCK
Synchronization Auto or disabled
Clock display HH:MM:SS
Hour format 12hr AM/PM (MSF format)
24hr (DCF format)
Calendar DD/MM or MM/DD;
weekday in 5 languages (E, G, F, I, S)
Alarm Daily & Pre-Alarm;
2- minute crescendo
Snooze 8 minutes
POWER
Main unit
Power adapter 6V AC adapter
Batteries 3 x UM-3 (AA) 1.5V
alkaline batteries (back-up)
Thermo-Hygro
Remote sensor 2 x UM-3 (AA) 1.5V
alkaline batteries
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children's electronic learning products and games; projection clocks; health and fitness gear; weather stations; and digital and conference phones. The website also includes contact information for our customer care department in case you need to reach us, as well as frequently asked questions and customer downloads.
We hope you will find all the information you need on our website, however if you'd like to contact the Oregon Scientific Customer Care department directly, please visit:
www2.oregonscientific.com/service/support
OR
Call 949-608-2848 in the US.
For international enquiries, please visit
www2.oregonscientific.com/
about/international/default.asp
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM23
Black
Page 25
EN
24
EC-DECLARATION OF CONFORMITY
This product contains the approved transmitter module that complies with the essential requirements of Article 3 of the R&TTE 1999 / 5 / EC Directive, if used as intended and the following standards have been applied:
Safety of information technology equipment
(Article 3.1.a of the R&TTE Directive) Applied Standard EN 60950-1 : 2001
Electromagnetic compatibility
(Article 3.1.b of the R&TTE Directive) Applied Standards
ETSI EN 301 489-1-3 (Ver.1.4.1) : 2002-08
Efficient use of radio frequency spectrum
(Article 3.2 of the R&TTE Directive) Applied Standards
ETSI EN 300 220-3 (Ver1.1.1) : 2000-09
Additional information:
The product herewith complies with the requirements of the Low Voltage Directive 73 / 23 / EC, the EMC Directive 89 / 336 / EC and carries the CE marking accordingly.
Carmelo Cubito Agrate Brianza (MI) / Italy January 2004 Manufacturer's EU R&TTE Representative
COUNTRIES RTTE APPROVAL COMPLIED
All EC countries, Switzerland
and Norway
CH
N
BAR321/323HGN English New R2 OP 8/17/04, 12:55 PM24
Black
Page 26
© 2004 Oregon Scientific. All Rights Reserved.
086-003370-048
BAR321/323HGN EN New Back R2 OP 8/17/04, 12:56 PM1
Black
Loading...