UNPACK
Make sure that you have all of the parts shown here before the installation of the Advanced Weather Station.
A
SET-UP MAIN UNIT
B
SET-UP INTEGRATED WIND SENSOR
C
INTEGRATED WIND GAUGE
RAIN GAUGE
USB Cable
Wind Vane
Support Base
Rectangular
Base Legs
Round
U-Shaped Bolts
Wind Direction
Indicator
Wind Sensor
Stem
Screws (Type B)
Pole Sections
Metal Pins
Tension Strings
Rain Collector
Filter
6V Adapter
Screws (Type A)
Washers
1.5V AA Batteries
Screws (Type C)
WMR100 Base
POLE MOUNT
1.5V AA Batteries
1.5V AA Batteries
Cone-Shaped End
2
1
3
4
6
8
9
Slide wind direction indicator onto wind sensor and align the screw holes. After aligning the holes, use a Type B screw to secure.
Attach the wind speed vane on the top of the wind sensor, align the holes, and use a Type B screw to secure.
When installing outside, rotate the NORTH Indicator reference line to the “north” and align the wind indicator in the same direction.
1
2
3
1
Install 4 AA batteries located underneath the base unit.
3
Press the RESET button.
2
Install power plug into the base station and insert the AV adapter into the wall outlet.
Rotate the battery cover counter-clockwise and slide cover off to expose the battery compartment. Insert 4 AA batteries.
Press the RESET button.
Rotate the battery cover clockwise and slide cover on to close the battery compartment.
On the base station, press the SEARCH button to initiate a wireless sensor search.
4
5
6
7
QUICK START GUIDE
WMR100 ADVANCED WEATHER STATION
with Wireless Sensor Set and Mounting Package
21
3
7
5
Wind Speed: Gently rotate the wind vane and confirm a numerical reading on the base unit ( ). Wind Direction Indicator: Move the direction of the wind indicator and verify the icon moves in the same ( ).
To test the temperature reading, press the SELECT button on the black rotating dial until the selected area icon ( ) is on the second level ( ) of the LCD display. Rotate the dial clockwise to channel 1 and verify a numeric reading.
8
9
Page 2
SET-UP RAIN GAUGE
Questions or comments? Contact our Customer Service Center
website: www2.oregonscientific.com/service phone: 800.853.8883 email: helpme@oscientific.com
D
SET-UP POLE
E
*To test the rain gauge you need to move the arrow to the bar graph section
by rotating the dial.
Press the SELECT button on the black rotating dial until the selected area icon ( ) is on the BAR GRAPH on the LCD.
Press the MODE button on the black rotating dial until the selected area icon is switched to Rainfall.
Tilt the tipping funnel on the rain gauge several times and verify a numerical reading on the base unit ( ).
6
7
8
Secure the battery cover with eight screws.
After verifying connection to the base station, place the rain gauge on a level surface and place a few drops of water on the cross at the base of the funnel to check the horizontal level. You can adjust the level when securing the rain gauge on the level screws by using the mounting screws.
To complete the installation, slide the hood cover on and secure with two base screws located on the bottom rim of the rain gauge.
9
10
11
Remove the two base screws located on the bottom rim of the rain gauge and slide the hood cover off to expose the battery compartment.
Locate the battery compartment and remove the eight screws that secure the cover. Install two AA batteries.
Remove the packing tape from the tipping funnel.
1
2
3
Press the RESET button.
Before proceeding to install the rain gauge outside, please verify communication to the main base station.
Press the SEARCH button to initiate a wireless sensor search.
5
4
6
1 3
2
7
8 9
11
10
4
5
7
8
9
1
2 3
5
4
6
Screw off the included nut and bolt from the plastic base.
Remove the round pole cover in the middle of the plastic base.
Insert the bottom pole until the screw hole aligns with the plastic base. Re-insert the nut and bolt and fasten. Screw the “cone shape” end clockwise onto the bottom pole.
Use the guiding end to start inserting bottom pole at a perpendicular angle into the ground.
Place a wooden block on the top of the bottom pole. With a hammer, hit the wooden block to hammer the guiding end into the ground until the plastic base reaches the base of the ground.
Attach the bottom pole with the middle pole, top pole, and the wind sensor using three type A screws to secure.
Insert two rectangular base legs into the plastic base to firmly fix the pole to the ground.
For better stability, drive the three pins into the ground and attach the tension strings from the pins to the plastic hooks located on the top pole.
Rotate the North Indicator reference line to the North and align the wind indicator in the same direction.
Press reset button on main unit to erase all testing data.
Option 1—With mounting pole
1
2
3
4
5
6
7
8
9
10
11
12
13 14
Detach the plastic connector at the end of the top pole by removing the type A screw.
Using the two U-bolts, secure the plastic base on the existing pole using the four washer and bolts.
Insert the top pole into the plastic base while aligning the holes to re-insert the bolt and secure by screwing the nut.
Assemble the wind sensor main body horizontally to the top pole and secure with a type A screw.
Rotate the North Indicator reference line to the North and align the wind indicator in the same direction.
Press reset button on main unit to erase all testing data.
Option 2—With side mounting kit on an existing pole
10
11