AL-9504-2
>
AL-9504-2
Emergency Stop (E-Stop) Unit
➊ APPLICATIONS
• General Purpose Positioning
Subsystems
• Remote Emergency Stop Support
➋ PRODUCT HIGHTLIGHTS
• Up to 4 External E-Stop Switch
Inputs
• Up to 5 Outputs for Controller
Interlock
• OSHA Compliant
AL-9504-PENDANT
The AL-9504-2 Emergency Stop (E-Stop) Unit provides a central connection point for external
emergency stop panic buttons and positioner controllers that are located throughout
the system. In the event of an emergency stop, the AL-9504-2 will command the appropriate
positioner controller to disconnect motor drive power on all axes.
This unit is designed to disable up to five controllers and can support up to four external
E-Stop panic buttons.
front panel
AC Power On/Off
Emergency Stop (E-Stop)
E-Stop Indicator
Driver Indicator
supplied accessories
>
CD-ROM Documentation Set:
User Manual (Installation, Setup, Operation)
>
Cables:
AC Power Cord, IEC-320 (F) to Plug
options
AL-9504-PENDANT - E-Stop button with 10m cable
Opt. 101 - Additional Manual Set
Optional Standard
ORDERING INFORMATION
• AL-9504-2 Emergency Stop (E-Stop) Unit
> Positioner Controllers, PCUs & LCUs
27
Specifications - AL-9504-2 E-Stop Unit
Model AL-9504-2
Operational
• AC Power On/Off
Front Panel Controls
& Indicators
Electrical
AC Input Power 115/230 VAC +/- 10%, 50/60 Hz, single phase
Power Dissipation 60 Watts
Remote E-Stop Channels
(Pendants)
AL-9504-PENDANT Switches & Interconnect Cables Purchased Separately
Compatible Products
Physical
Dimensions
• Emergency Stop (Latching Panic Button)
• E-Stop Indicator
• Driver Indicator
5
• AL-48062, AL-48063
• AL-4162, AL-4164
• AL-4147-2, AL-4107-2-6A
• 19.0 in (48.3 cm) Width
• 3.5 in (8.9 cm) Height
• 11.0 in (28.0 cm) Depth
Weight 10.3 lbs (4.7 kg)
Environmental
Operating Temperature 41° to 122° F (5° to 50° C)
Storage Temperature - 13° to 167° F (- 25° to 75° C)
Relative Humidity 70%