ORBIT FR AEP-X-CR User Manual

>
Clean Room RF Absorbers -
AEP-X-CR Series
AEP-36-CR
> Applications:
Satellite testing facilities
> Key features:
For use in Class 100,000 clean room environments -
AEMI CR1
For use in Class 10,000 clean room environments -
AEMI CR2
> Shape:
Pyramidal
Wedge
Flat
Convoluted
> Frequency band:
From 125 MHz to 18 GHz
> Standard base size:
2’ x 2’ (60.96 cm x 60.96 cm)
> Height:
Standard: 4’’ to 48’’ (10.2 cm to 121.9 cm)
Custom sizes available up to 96’’ (243.8 cm)
> Operating conditions:
Temperature: 70º F +/- 10º (21º C +/- 3º)
Relative humidity: 55 % RH +/-15 %
> Indoor/outdoor:
Indoor
> Treatment:
CR1 - Latex coating
CR2 - Rubberized coating
> Related certifi cations:
FS209E
ISO14644
NRL 8093 - 1, 2, 3
> Ordering code:
AEP-XX – CRX, where XX designates absorber
height in inches and CRX designates Clean Room Class
Adapted Absorbers
25
1/ Description
AEMI CR1 Clean Room RF Absorbers have a clear latex coating that completely covers the absorber, including the bottom. They are treated for use in class 100,000 clean room environments. This treatment does not ne­gatively affect the overall performance. These absorbers are used extensively in satellite assembly facilities as well as other aerospace applications.
gatively affect the overall performance. These absorbers are used extensively in satellite assembly facilities as well as other aerospace applications.
2/ Unique Manufacturing Process
After the standard manufacturing process, these ma­terials undergo further treatment to remove any loose debris from the manufacturing process. The material is coated with a special latex binder or plasticized coating
AEMI CR2 Clean Room RF Absorbers have a rubberized
(depending on class).
treatment that completely covers the absorber, including the bottom. They are treated for use in class 10,000 clean room environments. This treatment does not ne-
3/ Specifi cations
AEP-4-CR AEP-6-CR AEP-8-CR AEP-12-CR AEP-18-CR AEP-24-CR AEP-36-CR AEP-48-CR
Height in 4 6 8 12 18 24 36 48
cm 10.2 15.2 20.3 30.5 45.7 61 91.4 121.9
Pyramids per block 144 64 64 36 16 9 4 4
@ 125 MHz dB 28
@ 250 MHz dB 30 32 35
@ 500 MHz dB 30 35 37 40
@ 1.0 GHz dB 30 35 37 40 42 45
@ 3.0 GHz dB 30 33 37 40 45 45 50 50
@ 6.0 GHz dB 35 37 45 45 50 50 50 50
@ 10.0 GHz dB 40 40 50 50 50 50 50 50
@ 13.0 GHz dB 45 50 50 50 50 50 50 50
Absorption @ Normal Incidence
@ 15.0 GHz dB 50 50 50 50 50 50 50 50
2
Power Watt/in
Watt/m
Weight lbs/pc. 2.5 3 4.5 6 9 13.5 18.5 25 kg/pc. 1.1 1.4 2 2.7 4.1 6.1 8.4 11.3
0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
2
775 775 775 775 775 775 775 775
26
AEP-6-CR mechanical drawing
6”
2”
24”
1”
24”
Loading...