This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws. Except
as expressly permitted in your license agreement or allowed by law, you may not use, copy, reproduce, translate, broadcast, modify, license, transmit, distribute, exhibit, perform,
publish, or display any part, in any form, or by any means. Reverse engineering, disassembly, or decompilation of this software, unless required by law for interoperability, is
prohibited.
The information contained herein is subject to change without notice and is not warranted to be error-free. If you find any errors, please report them to us in writing.
If this is software or related documentation that is delivered to the U.S. Government or anyone licensing it on behalf of the U.S. Government, then the following notice is applicable:
U.S. GOVERNMENT END USERS. Oracle programs, including any operating system, integrated software, any programs installed on the hardware, and/or documentation, delivered
to U.S. Government end users are "commercial computer software" pursuant to the applicable Federal Acquisition Regulation and agency-specific supplemental regulations. As
such, use, duplication, disclosure, modification, and adaptation of the programs, including any operating system, integrated software, any programs installed on the hardware, and/or
documentation, shall be subject to license terms and license restrictions applicable to the programs. No other rights are granted to the U.S. Government.
This software or hardware is developed for general use in a variety of information management applications. It is not developed or intended for use in any inherently dangerous
applications, including applications that may create a risk of personal injury. If you use this software or hardware in dangerous applications, then you shall be responsible to take all
appropriate fail-safe, backup, redundancy, and other measures to ensure its safe use. Oracle Corporation and its affiliates disclaim any liability for any damages caused by use of this
software or hardware in dangerous applications.
Oracle and Java are registered trademarks of Oracle and/or its affiliates. Other names may be trademarks of their respective owners.
Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation. All SPARC trademarks are used under license and are trademarks or registered trademarks of
SPARC International, Inc. AMD, Opteron, the AMD logo, and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices. UNIX is a registered
trademark of The Open Group.
This software or hardware and documentation may provide access to or information about content, products, and services from third parties. Oracle Corporation and its affiliates are
not responsible for and expressly disclaim all warranties of any kind with respect to third-party content, products, and services unless otherwise set forth in an applicable agreement
between you and Oracle. Oracle Corporation and its affiliates will not be responsible for any loss, costs, or damages incurred due to your access to or use of third-party content,
products, or services, except as set forth in an applicable agreement between you and Oracle.
Documentation Accessibility
For information about Oracle's commitment to accessibility, visit the Oracle Accessibility Program website at http://www.oracle.com/pls/topic/lookup?ctx=acc&id=docacc.
Access to Oracle Support
Oracle customers that have purchased support have access to electronic support through My Oracle Support. For information, visit http://www.oracle.com/pls/topic/lookup?
ctx=acc&id=info or visit http://www.oracle.com/pls/topic/lookup?ctx=acc&id=trs if you are hearing impaired.
Ce logiciel et la documentation qui l’accompagne sont protégés par les lois sur la propriété intellectuelle. Ils sont concédés sous licence et soumis à des restrictions d’utilisation et
de divulgation. Sauf stipulation expresse de votre contrat de licence ou de la loi, vous ne pouvez pas copier, reproduire, traduire, diffuser, modifier, accorder de licence, transmettre,
distribuer, exposer, exécuter, publier ou afficher le logiciel, même partiellement, sous quelque forme et par quelque procédé que ce soit. Par ailleurs, il est interdit de procéder à toute
ingénierie inverse du logiciel, de le désassembler ou de le décompiler, excepté à des fins d’interopérabilité avec des logiciels tiers ou tel que prescrit par la loi.
Les informations fournies dans ce document sont susceptibles de modification sans préavis. Par ailleurs, Oracle Corporation ne garantit pas qu’elles soient exemptes d’erreurs et vous
invite, le cas échéant, à lui en faire part par écrit.
Si ce logiciel, ou la documentation qui l’accompagne, est livré sous licence au Gouvernement des Etats-Unis, ou à quiconque qui aurait souscrit la licence de ce logiciel pour le
compte du Gouvernement des Etats-Unis, la notice suivante s’applique:
U.S. GOVERNMENT END USERS. Oracle programs, including any operating system, integrated software, any programs installed on the hardware, and/or documentation, delivered
to U.S. Government end users are "commercial computer software" pursuant to the applicable Federal Acquisition Regulation and agency-specific supplemental regulations. As
such, use, duplication, disclosure, modification, and adaptation of the programs, including any operating system, integrated software, any programs installed on the hardware, and/or
documentation, shall be subject to license terms and license restrictions applicable to the programs. No other rights are granted to the U.S. Government.
Ce logiciel ou matériel a été développé pour un usage général dans le cadre d’applications de gestion des informations. Ce logiciel ou matériel n’est pas conçu ni n’est destiné
à être utilisé dans des applications à risque, notamment dans des applications pouvant causer des dommages corporels. Si vous utilisez ce logiciel ou matériel dans le cadre d’
applications dangereuses, il est de votre responsabilité de prendre toutes les mesures de secours, de sauvegarde, de redondance et autres mesures nécessaires à son utilisation dans des
conditions optimales de sécurité. Oracle Corporation et ses affiliés déclinent toute responsabilité quant aux dommages causés par l’utilisation de ce logiciel ou matériel pour ce type
d’applications.
Oracle et Java sont des marques déposées d’Oracle Corporation et/ou de ses affiliés. Tout autre nom mentionné peut correspondre à des marques appartenant à d’autres propriétaires
qu’Oracle.
Intel et Intel Xeon sont des marques ou des marques déposées d’Intel Corporation. Toutes les marques SPARC sont utilisées sous licence et sont des marques ou des marques
déposées de SPARC International, Inc. AMD, Opteron, le logo AMD et le logo AMD Opteron sont des marques ou des marques déposées d’Advanced Micro Devices. UNIX est une
marque déposée d’The Open Group.
Ce logiciel ou matériel et la documentation qui l’accompagne peuvent fournir des informations ou des liens donnant accès à des contenus, des produits et des services émanant de
tiers. Oracle Corporation et ses affiliés déclinent toute responsabilité ou garantie expresse quant aux contenus, produits ou services émanant de tiers, sauf mention contraire stipulée
dans un contrat entre vous et Oracle. En aucun cas, Oracle Corporation et ses affiliés ne sauraient être tenus pour responsables des pertes subies, des coûts occasionnés ou des
dommages causés par l’accès à des contenus, produits ou services tiers, ou à leur utilisation, sauf mention contraire stipulée dans un contrat entre vous et Oracle.
Accessibilité de la documentation
Pour plus d’informations sur l’engagement d’Oracle pour l’accessibilité à la documentation, visitez le site Web Oracle Accessibility Program, à l’adresse http://www.oracle.com/
pls/topic/lookup?ctx=acc&id=docacc.
Accès aux services de support Oracle
Les clients Oracle qui ont souscrit un contrat de support ont accès au support électronique via My Oracle Support. Pour plus d’informations, visitez le site http://www.oracle.com/
pls/topic/lookup?ctx=acc&id=info ou le site http://www.oracle.com/pls/topic/lookup?ctx=acc&id=trs si vous êtes malentendant.
Page 5
Contents
Using This Documentation ................................................................................. 9
Documentation and resources for this product and related products are available at http://www.
oracle.com/goto/is2-46/docs.
Feedback
Provide feedback about this documentation at http://www.oracle.com/goto/docfeedback.
Using This Documentation9
Page 10
10Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 11
Understanding the Switch
These topics describe the switch and the installation process.
■
“Installation Task Overview” on page 11
■
“Switch Overview” on page 13
■
“Front Panel Components” on page 14
■
“Rear Panel Components” on page 15
Related Information
■
“Confirming Specifications” on page 17
■
“Preparing for Installation” on page 23
■
“Installing the Switch” on page 29
■
“Connecting Cables” on page 49
■
“Powering On the Switch” on page 67
■
“Verifying Functionality” on page 87
Installation Task Overview
A full-time SER MGT connection is where there is a persistent serial connection to the SER
MGT port, and it is used for switch administration. A temporary SER MGT connection is
where the SER MGT port is used only for switch installation and configuration of network
management. Thereafter, network management is used for switch administration. The
installation task overview accommodates both connection types and identifies any deviations
from the installation sequence.
StepDescriptionLinks
1.Familiarize yourself with the front and rear of
the switch.
2.Confirm supplied power and environmental
factors.
■ “Front Panel Components” on page 14
■ “Rear Panel Components” on page 15
■ “Physical Specifications” on page 17
■ “Electrical Specifications” on page 18
■ “Environmental Specifications” on page 18
Understanding the Switch11
Page 12
Installation Task Overview
StepDescriptionLinks
3.Understand air flow characteristics and rack
cautions.
■ “Airflow Precautions” on page 19
■ “Rack Compatibility” on page 20
■ “Rack Precautions” on page 20
4.Verify shipped components and accessories.■ “Shipping Kit” on page 24
5.Record the MAC IDs.■ “Record the MAC IDs” on page 25
6.If DHCP is to assign specific IP addresses to
■ “Assign IP Addresses to the SP and SCP Through DHCP” on page 26
the SP and SCP, configure the DHCP server.
7.Heed handling and ESD precautions.■ “Handling Precautions” on page 26
■ “ESD Precautions” on page 27
8.
Gather appropriate tools.■ “Installation Tools” on page 27
.
9.Install the switch into the rack.■ “Installing the Switch” on page 29
10.Understand cable requirements and
precautions.
■ “Cable Requirements” on page 49
■ “Standard MT and PrizmMT Cables” on page 50
■ “Cable Precautions” on page 52
11.If necessary, assemble the optical data cables.■ “Assemble the SFP+ Cables” on page 54
12.Route the data cables.■ “Route the Cables” on page 56
13.Connect data cables and secure them to the
cable management bracket (CMB).
■ “Connect the RJ-45 Ethernet Cables” on page 57
■ “Connect the PrizmMT Cables” on page 58
■ “Connect the SFP+ Cables” on page 60
■ “Secure Cables to the CMB” on page 62
14.Retrieve the power cords and SER MGT
■ “Retrieve the Power Cords and SER MGT Cable” on page 67
cable.
15.Connect the serial management device.■ “Connect the SER MGT Cable” on page 71
■ “Connect a Serial Management Device to the SER MGT
Port” on page 74
16.Connect power cords.■ “Connect the Power Cords” on page 74
17.If you have a full-time SER MGT connection,
■ “Install the Air Duct Assembly” on page 76
install the air duct. If you have a temporary
SER MGT connection, instead go to Step 15.
18.Power on the switch.■ “Power On the Switch” on page 78
19.Log in to the service processor (SP).■ “Log In to the SP (SER MGT)” on page 79
■ “Assign a Static IP Address to the SP” on page 80
■ “Assign a Static IP Address to the SCP” on page 82
■ “Log In to the SP (Network Management)” on page 84
20.If you have a temporary SER MGT
■ “Install the Air Duct Assembly” on page 76
connection, install the airduct.
21.Verify switch functionality.■ “Verify LED Status” on page 87
■ “Verify That the Switch Is Operational” on page 89
■ “Verify Connectivity” on page 91
22.Administer the switch.■ “Log In to the Oracle Fabric Manager Interface” on page 94
■ “Log In to the Oracle Fabric OS Interface” on page 96
■ “Run the Oracle Fabric OS Configuration Wizard” on page 97
12Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 13
Related Information
■
“Switch Overview” on page 13
■
“Front Panel Components” on page 14
■
“Rear Panel Components” on page 15
Switch Overview
Switch Overview
The switch is a complete access switching and I/O platform that consolidates and virtualizes the
switching infrastructure for server and storage systems deployed in high-performance enterprise
clouds.
The switch features up to 38 4x IB ports supporting EDR speeds. Additionally, 10 10GbE ports
and 24 1GBASE-T ports provide both network and gateway capabilities.
Separate, dedicated, and optimized on-board SP, ABD, and SCP manage chassis functionality,
Ethernet traffic, and IB fabric respectively, through user-friendly CLIs and GUIs.
The switch ships preconfigured for network management through DHCP. However, the
procedures in this document are serial management focused, with instructions to configure
static IP addresses.
Understanding the Switch13
Page 14
Front Panel Components
Related Information
■
“Installation Task Overview” on page 11
■
“Front Panel Components” on page 14
■
“Rear Panel Components” on page 15
Front Panel Components
The front panel is the fan and power supply end of the switch. This end of the switch is installed
to the cold aisle.
No.Description
1Power supplies
2Power cord receptacles
3Fan modules
4RFID tag
5SER MGT port
6SER MGT module (SMM), with battery inside
Related Information
■
“Installation Task Overview” on page 11
■
“Switch Overview” on page 13
■
“Rear Panel Components” on page 15
14Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 15
Rear Panel Components
The rear panel is the data cable connection end of the switch. This end of the switch is installed
to the hot aisle.
No.Description
1PrizmMT connectors:
■ Ports 1 to 24 – IB 4x (magenta housing)
■ Ports 25 and 26 – Either IB 4x or 10GbE (magenta housing)
Note - The two right-most connectors, labeled 1 and 2, can also be used for network
management.
3RJ-45 connectors – Any one of these connectors can be used for network management.
4Chassis status LEDs
Related Information
■
“Installation Task Overview” on page 11
■
“Switch Overview” on page 13
■
“Front Panel Components” on page 14
Understanding the Switch15
Page 16
16Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 17
Confirming Specifications
These topics describe the specifications of the switch and related precautions for installation.
■
“Physical Specifications” on page 17
■
“Electrical Specifications” on page 18
■
“Environmental Specifications” on page 18
■
“Airflow Precautions” on page 19
■
“Rack Compatibility” on page 20
■
“Rack Precautions” on page 20
Related Information
■
“Understanding the Switch” on page 11
■
“Preparing for Installation” on page 23
■
“Installing the Switch” on page 29
■
“Connecting Cables” on page 49
■
“Powering On the Switch” on page 67
■
“Verifying Functionality” on page 87
Physical Specifications
DimensionMetricU.S.
RU11
Width445.0 mm17.52 in.
Depth609.6 mm24 in.
Height44.5 mm1.75 in.
Weight11.4 kg23.0 lbs
Related Information
■
“Electrical Specifications” on page 18
Confirming Specifications17
Page 18
Electrical Specifications
■
“Environmental Specifications” on page 18
■
“Airflow Precautions” on page 19
■
“Rack Compatibility” on page 20
■
“Rack Precautions” on page 20
Electrical Specifications
ParameterAC Requirement
Voltage100 VAC to 240 VAC single phase, 47 to 63 Hz
Current (per input)5.4A maximum per input at 100 VAC
Current (total)5.6A maximum total for all inputs at 100 VAC
Power550W (Total input power is approximately equally divided among the
operating power supplies.)
Related Information
■
“Physical Specifications” on page 17
■
“Environmental Specifications” on page 18
■
“Airflow Precautions” on page 19
■
“Rack Compatibility” on page 20
■
“Rack Precautions” on page 20
Environmental Specifications
ParameterMetric OperatingU.S. Operating
Temperature5˚C to 35˚C41˚F to 95˚F
Humidity5% to 85% noncondensing, 27˚C maximum wet
Elevation (Oracle requirement)Maximum 3000 meters at 40˚CMaximum 9840 feet at 104˚F
bulb
Related Information
■
“Physical Specifications” on page 17
■
“Electrical Specifications” on page 18
5% to 85% noncondensing, 80˚F maximum wet
bulb
18Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 19
■
“Airflow Precautions” on page 19
■
“Rack Compatibility” on page 20
■
“Rack Precautions” on page 20
Airflow Precautions
Caution - Proper airflow is essential for keeping the switch's internal temperatures within a safe
operating range.
Air flows from the front (fan end) of the switch to the rear (connector end) of the switch. Air
flows through the power supplies from the sides of the switch to out the front.
Airflow Precautions
Follow these guidelines to ensure unrestricted airflow in the switch:
■
Install the switch so that the front faces the cool aisle and the rear faces the warm aisle.
■
Do not direct warm air into the switch.
■
Prevent recirculation of air within a rack or cabinet.
■
After servicing the switch, ensure that the air duct assembly is properly installed.
■
Route cables so that they do not interfere with airflow.
Confirming Specifications19
Page 20
Rack Compatibility
■
Install the air duct assembly at the front of the switch.
Related Information
■
“Physical Specifications” on page 17
■
“Electrical Specifications” on page 18
■
“Environmental Specifications” on page 18
■
“Rack Compatibility” on page 20
■
“Rack Precautions” on page 20
Rack Compatibility
This switch and rackmounting hardware is designed for installation into a Sun Rack II or
compatible rack or cabinet. The switch has a shorter form factor than Oracle rackmounted
computing products. There is a gap between the rack front door and the switch front panel. To
aid in proper airflow management and minimize air recirculation within the rack, install the air
duct assembly at the front of the switch.
Related Information
■
“Physical Specifications” on page 17
■
“Electrical Specifications” on page 18
■
“Environmental Specifications” on page 18
■
“Airflow Precautions” on page 19
■
“Rack Precautions” on page 20
Rack Precautions
Caution - Equipment Loading. Always load equipment into a rack from the bottom to the
top so that the rack does not become top heavy and tip over. Deploy your rack's antitilt legs to
prevent the rack from tipping during equipment installation.
Caution - Elevated Operating Ambient Temperature. If the switch is installed in a closed
or multi-unit rack assembly, the operating ambient temperature of the rack environment might
be greater than the room ambient temperature. Therefore, install the equipment only in an
environment compatible with the Tma specified for the switch.
20Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 21
Rack Precautions
Caution - Reduced Air Flow. Install the equipment in a rack so that the amount of air flow is
adequate for the safe operation of the equipment.
Caution - Mechanical Loading. Mount the equipment in the rack so that the weight is
distributed evenly. A hazardous condition can exist with uneven mechanical loading.
Caution - Circuit Overloading. Do not overload the power supply circuits. Before connecting
the switch to the supply circuit, review the equipment nameplate power ratings and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring.
Caution - Reliable Grounding. Maintain reliable grounding of rackmounted equipment. Give
particular attention to supply connections other than direct connections to the branch circuit (for
example, use of power strips).
Caution - Do not use rack mounted equipment as a shelf or a work space.
Related Information
■
“Physical Specifications” on page 17
■
“Electrical Specifications” on page 18
■
“Environmental Specifications” on page 18
■
“Airflow Precautions” on page 19
■
“Rack Compatibility” on page 20
Confirming Specifications21
Page 22
22Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 23
Preparing for Installation
These topics provide information to prepare for the switch installation process.
■
“Shipping Kit” on page 24
■
“Record the MAC IDs” on page 25
■
“Assign IP Addresses to the SP and SCP Through DHCP” on page 26
■
“Handling Precautions” on page 26
■
“ESD Precautions” on page 27
■
“Installation Tools” on page 27
Related Information
■
“Understanding the Switch” on page 11
■
“Confirming Specifications” on page 17
■
“Installing the Switch” on page 29
■
“Connecting Cables” on page 49
■
“Powering On the Switch” on page 67
■
“Verifying Functionality” on page 87
Preparing for Installation23
Page 24
Shipping Kit
Shipping Kit
No.Description
1Switch
2Front mounting brackets, long (shown mounted)
3Front mounting brackets, short
4C-channel brackets (shown mounted)
5Fasteners
6Power cords
7Documentation
8Cable management extenders
9Long rails
10Cable management cover
11Cable management bracket (CMB)
12Attachment brackets
13Attachment plates
14Air duct
15Cover
16Snap brackets
24Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 25
Related Information
■
“Record the MAC IDs” on page 25
■
“Assign IP Addresses to the SP and SCP Through DHCP” on page 26
■
“Handling Precautions” on page 26
■
“ESD Precautions” on page 27
■
“Installation Tools” on page 27
Record the MAC IDs
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Remove the Customer Information sheet from the outside of the shipping carton.
Record the MAC IDs
3.
On the Customer Information sheet, find the switch serial number.
4.
Record the serial number to a document intended for this purpose.
5.
In the Network Interfaces table of the sheet, find the primary MAC ID.
This is the MAC ID of the SP within the switch.
6.
Record the SP MAC ID to the document.
7.
In the Network Interfaces table of the sheet, find the secondary MAC ID.
This is the MAC ID of the SCP within the switch.
8.
Record the SCP MAC ID to the document.
9.
Secure the Customer Information sheet in a safe place.
10.
Consider your next steps.
■If you will assign IP addresses to the SP and SCP through DHCP, configure
your DHCP server now.
See “Assign IP Addresses to the SP and SCP Through DHCP” on page 26.
■If you will assign static IP addresses to the SP and SCP through the SER
MGT port, go to “Handling Precautions” on page 26.
Preparing for Installation25
Page 26
Assign IP Addresses to the SP and SCP Through DHCP
Related Information
■
“Shipping Kit” on page 24
■
“Assign IP Addresses to the SP and SCP Through DHCP” on page 26
■
“Handling Precautions” on page 26
■
“ESD Precautions” on page 27
■
“Installation Tools” on page 27
Assign IP Addresses to the SP and SCP Through DHCP
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Log in to the DHCP server and configure it to assign a predetermined IP address
and host name for the SP MAC ID you recorded.
Record this IP address and host name for future reference.
3.
Configure the DHCP server to assign a predetermined IP address and host name
for the SCP MAC ID you recorded.
Record this IP address and host name for future reference.
When the switch is connected to the management network and powered on, the SP and SCP
will receive the predetermined IP addresses.
4.
Continue the installation.
See “Handling Precautions” on page 26.
Related Information
■
“Shipping Kit” on page 24
■
“Record the MAC IDs” on page 25
■
“Handling Precautions” on page 26
■
“ESD Precautions” on page 27
■
“Installation Tools” on page 27
Handling Precautions
Caution - Deploy the antitilt legs on the equipment rack before beginning an installation.
26Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 27
Caution - Two people are required to lift and mount this switch into a rack when performing the
tasks in this document.
Caution - When performing a two-person task, always communicate your intentions clearly
before, during, and after each step to minimize confusion.
Related Information
■
“Shipping Kit” on page 24
■
“Record the MAC IDs” on page 25
■
“Assign IP Addresses to the SP and SCP Through DHCP” on page 26
■
“ESD Precautions” on page 27
■
“Installation Tools” on page 27
ESD Precautions
ESD Precautions
When installing the switch chassis, follow antistatic precautions:
■
Use an antistatic mat as a work surface.
■
Wear an antistatic wrist strap that is attached to either the mat or a metal portion of the
switch chassis.
Related Information
■
“Shipping Kit” on page 24
■
“Record the MAC IDs” on page 25
■
“Assign IP Addresses to the SP and SCP Through DHCP” on page 26
■
“Handling Precautions” on page 26
■
“Installation Tools” on page 27
Installation Tools
These tools are necessary or beneficial for installing the switch:
■
Antistatic wrist strap
■
No. 2 Philips screwdriver
Preparing for Installation27
Page 28
Installation Tools
■
No. 1 Philips screwdriver
■
Cage nut installation tool or flat-blade screwdriver
■
Serial terminal device and necessary cabling
■
Masking tape
■
Paper clip
■
PrizmMT ferrule cleaner - USConec part number 16899
■
Antistatic mat
■
Flashlight
■
Gloves
Related Information
■
“Shipping Kit” on page 24
■
“Record the MAC IDs” on page 25
■
“Assign IP Addresses to the SP and SCP Through DHCP” on page 26
■
“Handling Precautions” on page 26
■
“ESD Precautions” on page 27
28Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 29
Installing the Switch
Perform these tasks in the order presented to install the switch.
■
“Stabilize the Rack” on page 29
■
“Install the Switch Brackets” on page 30
■
“Assemble the Cable Management Extenders” on page 32
■
“Prepare the Air Duct Assembly” on page 33
■
“Install the Cage Nuts” on page 35
■
“Install the Rackmount Hardware” on page 37
■
“Route the Power Cords” on page 38
■
“Route the SER MGT Cable” on page 39
■
“Install the Switch” on page 40
■
“Install the CMB” on page 45
Related Information
■
“Understanding the Switch” on page 11
■
“Confirming Specifications” on page 17
■
“Preparing for Installation” on page 23
■
“Connecting Cables” on page 49
■
“Powering On the Switch” on page 67
■
“Verifying Functionality” on page 87
Stabilize the Rack
Caution - To reduce the risk of personal injury, stabilize the rack and extend all antitilt devices
before installing the switch.
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
Installing the Switch29
Page 30
Install the Switch Brackets
See “Installation Task Overview” on page 11.
2.
Open and remove the front and rear doors from the rack.
3.
If there are leveling feet beneath the rack to prevent it from rolling, extend these
leveling feet fully downward to the floor.
4.
Fully extend the rack's antitilt legs or antitilt bar, which are located at the bottom
front of the rack.
5.
Install the mounting brackets on the switch.
See “Install the Switch Brackets” on page 30.
Related Information
■
■
■
■
■
■
■
■
■
“Install the Switch Brackets” on page 30
“Assemble the Cable Management Extenders” on page 32
“Prepare the Air Duct Assembly” on page 33
“Install the Cage Nuts” on page 35
“Install the Rackmount Hardware” on page 37
“Route the Power Cords” on page 38
“Route the SER MGT Cable” on page 39
“Install the Switch” on page 40
“Install the CMB” on page 45
Install the Switch Brackets
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Using a No. 1 Philips screwdriver, attach the long front brackets (with cutouts) to
the front of the switch with four M3x6 flathead screws on each side.
30Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 31
Install the Switch Brackets
The flange of the long front mounting brackets points away from the switch.
3.
Attach the C-channel brackets to the switch with four M3x6 flathead screws on
each side.
The edge of each C-channel bracket is flush to the rear of the chassis.
4.
Assemble the cable management extenders.
See “Assemble the Cable Management Extenders” on page 32.
Related Information
■
“Stabilize the Rack” on page 29
■
“Assemble the Cable Management Extenders” on page 32
■
“Prepare the Air Duct Assembly” on page 33
■
“Install the Cage Nuts” on page 35
■
“Install the Rackmount Hardware” on page 37
■
“Route the Power Cords” on page 38
■
“Route the SER MGT Cable” on page 39
■
“Install the Switch” on page 40
■
“Install the CMB” on page 45
Installing the Switch31
Page 32
Assemble the Cable Management Extenders
Assemble the Cable Management Extenders
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Slide the attachment bracket over the extender, so that the tab on the bracket is
opposite the flange on the extender.
The open end of the tab is toward the flange. The flat end of the tab is toward the rear of the
extender.
3.
Place the attachment plate on the flange side of the extender, opposite the
attachment bracket.
4.
Use two M4x10 flathead screws to sandwich the attachment bracket and plate to
the extender, in the position farthest from the flange.
5.
Using a No. 1 Phillips screwdriver, tighten the two screws.
32Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 33
Prepare the Air Duct Assembly
6.
Repeat Step 2 through Step 5 for the other cable management extender.
7.
Prepare the air duct assembly.
See “Prepare the Air Duct Assembly” on page 33.
Related Information
■
“Stabilize the Rack” on page 29
■
“Install the Switch Brackets” on page 30
■
“Prepare the Air Duct Assembly” on page 33
■
“Install the Cage Nuts” on page 35
■
“Install the Rackmount Hardware” on page 37
■
“Route the Power Cords” on page 38
■
“Route the SER MGT Cable” on page 39
■
“Install the Switch” on page 40
■
“Install the CMB” on page 45
Prepare the Air Duct Assembly
Note - Both the cover and air duct are symmetrical, and have no defined top or bottom. If the
cover has a logo, that logo goes to the right.
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
Installing the Switch33
Page 34
Prepare the Air Duct Assembly
2.
Align the large opening of the air duct with the mesh on the back side of the
cover.
3.
Press the air duct into the cover, to make a firm friction fit.
4.
Install the cage nuts into the rack.
See “Install the Cage Nuts” on page 35.
Related Information
■
“Stabilize the Rack” on page 29
■
“Install the Switch Brackets” on page 30
■
“Assemble the Cable Management Extenders” on page 32
■
“Install the Cage Nuts” on page 35
■
“Install the Rackmount Hardware” on page 37
■
“Route the Power Cords” on page 38
■
“Route the SER MGT Cable” on page 39
■
“Install the Switch” on page 40
■
“Install the CMB” on page 45
34Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 35
Install the Cage Nuts
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Determine where you are installing the switch.
3.
Mark this location on each rack post with masking tape.
Install the Cage Nuts
Counting the number of rack units from the bottom of the rack to the mounting location assists
you when marking the other rack posts.
4.
Install eight cage nuts into the rack, two cage nuts for each rack post.
Installing the Switch35
Page 36
Install the Cage Nuts
Note - Each RU mounting location on the rack post has three square holes. For installing the
switch, there is no need for a cage nut in the center hole.
a.
Orient the cage nut to the square hole with the flanges to the right and left.
b.
Insert the outer flange into the square hole.
c.
Using the cage nut installation tool or flat-blade screwdriver as a guide,
catch the inner flange and pry it into the square hole.
d.
Pull the cage nut installation tool or flat blade screwdriver from the flange.
e.
Repeat Step 4a to Step 4d for each cage nut.
5.
Install the rackmount hardware.
See “Install the Rackmount Hardware” on page 37.
Related Information
■
“Stabilize the Rack” on page 29
■
“Install the Switch Brackets” on page 30
■
“Assemble the Cable Management Extenders” on page 32
■
“Prepare the Air Duct Assembly” on page 33
■
“Install the Rackmount Hardware” on page 37
36Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 37
■
“Route the Power Cords” on page 38
■
“Route the SER MGT Cable” on page 39
■
“Install the Switch” on page 40
■
“Install the CMB” on page 45
Install the Rackmount Hardware
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Place the long rail at the mounting location on the post at the rear of the rack.
3.
Butt the flange of the cable management extender against the flange of the long
rail.
Install the Rackmount Hardware
4.
Using a No. 2 Philips screwdriver, secure the assembly to the post with two
M6x12 screws.
5.
Repeat Step 2 through Step 4 for the other cable management extender and long
rail.
Installing the Switch37
Page 38
Route the Power Cords
6.
Route the power cords.
See “Route the Power Cords” on page 38.
Related Information
■
“Stabilize the Rack” on page 29
■
“Install the Switch Brackets” on page 30
■
“Assemble the Cable Management Extenders” on page 32
■
“Prepare the Air Duct Assembly” on page 33
■
“Install the Cage Nuts” on page 35
■
“Route the Power Cords” on page 38
■
“Route the SER MGT Cable” on page 39
■
“Install the Switch” on page 40
■
“Install the CMB” on page 45
Route the Power Cords
The facility power receptacles for the power cords should be located such that the power cords
are routed out of the way.
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Route the female end of the power cords up from the power distribution panel or
receptacles at the rear of the rack.
3.
Route the cords across the rack ceiling to the front of the rack.
4.
Route the cords down through the vertical support, so that the female end rests
at the location where the switch will install.
5.
Add about 3 inches of slack to enable connection and disconnection with the
switch power supply receptacles.
6.
Secure the power cord to this vertical length, so that it does not drop any farther.
Use hook and loop fastener straps to bundle and secure the cords.
7.
Consider your next task.
■If you will have a full-time SER MGT connection, route the SER MGT cable.
See “Route the SER MGT Cable” on page 39.
38Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 39
■If the SER MGT connection is only temporary for installation, install the
switch now.
See “Install the Switch” on page 40.
Related Information
■
“Stabilize the Rack” on page 29
■
“Install the Switch Brackets” on page 30
■
“Assemble the Cable Management Extenders” on page 32
■
“Prepare the Air Duct Assembly” on page 33
■
“Install the Cage Nuts” on page 35
■
“Install the Rackmount Hardware” on page 37
■
“Route the SER MGT Cable” on page 39
■
“Install the Switch” on page 40
■
“Install the CMB” on page 45
Route the SER MGT Cable
Route the SER MGT Cable
If there is to be a full-time connection of the SER MGT cable, such as to a terminal server,
follow this task to route the cable.
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Route the SER MGT cable from its entry point at the rear of the rack up to the
ceiling of the rack.
3.
Route the SER MGT cable across the rack ceiling to the front of the rack.
The SER MGT cable can run parallel to one of the power cords.
4.
Route the SER MGT cable down through the vertical support, so that the end
rests at the location where you are installing the switch.
5.
Add slack to the SER MGT cable to enable connection and disconnection with
the SER MGT port.
■If the SER MGT cable is on the left side of the rack, add 12 inches of slack.
■If the SER MGT cable is on the right side of the rack, add 24 inches of slack.
Installing the Switch39
Page 40
Install the Switch
6.
7.
Secure the SER MGT cable to this vertical length, so that it does not drop any
farther.
Use hook and loop fastener straps to bundle and secure the SER MGT cable.
Install the switch.
See “Install the Switch” on page 40.
Related Information
■
“Stabilize the Rack” on page 29
■
“Install the Switch Brackets” on page 30
■
“Assemble the Cable Management Extenders” on page 32
■
“Prepare the Air Duct Assembly” on page 33
■
“Install the Cage Nuts” on page 35
■
“Install the Rackmount Hardware” on page 37
■
“Route the Power Cords” on page 38
■
“Install the Switch” on page 40
■
“Install the CMB” on page 45
Install the Switch
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Carefully lift the switch and slide it into the rack, from the front rearward.
40Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 41
Install the Switch
Ensure that the ends of the long rails slide into the C-channel brackets at the rear of the switch
chassis.
3.
Using a No. 2 Philips screwdriver, hold the front of the switch chassis to the
front rack posts with two M6x12 screws at each side.
Installing the Switch41
Page 42
Install the Switch
Note - Do not fully tighten the screws at this time.
42Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 43
4.
Slide the snap bracket under the loose screws with the tabs pointing into the
rack.
Install the Switch
Installing the Switch43
Page 44
Install the Switch
5.
While pressing on the word PUSH embossed in the snap bracket, fully tighten
the screws.
6.
Repeat for the snap bracket on the other side.
7.
Install the CMB.
See “Install the CMB” on page 45.
Related Information
■
“Stabilize the Rack” on page 29
■
“Install the Switch Brackets” on page 30
■
“Assemble the Cable Management Extenders” on page 32
■
“Prepare the Air Duct Assembly” on page 33
■
“Install the Cage Nuts” on page 35
■
“Install the Rackmount Hardware” on page 37
■
“Route the Power Cords” on page 38
■
“Route the SER MGT Cable” on page 39
■
“Install the CMB” on page 45
44Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 45
Install the CMB
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
If installed, loosen the two captive thumbscrews that secure the cover to the
CMB and lift the cover off.
Install the CMB
Installing the Switch45
Page 46
Install the CMB
3.
Install the CMB to the tabs of the attachment brackets at the rear of the switch,
tightening the thumbscrews on each side of the CMB.
4.
Consider your next task.
■If your SFP+ optical cables must be assembled, do that now.
See “Assemble the SFP+ Cables” on page 54.
■If no cable assembly is required, route the cables to the switch.
See “Route the Cables” on page 56.
Related Information
■
“Stabilize the Rack” on page 29
■
“Install the Switch Brackets” on page 30
■
“Assemble the Cable Management Extenders” on page 32
■
“Prepare the Air Duct Assembly” on page 33
■
“Install the Cage Nuts” on page 35
■
“Install the Rackmount Hardware” on page 37
■
“Route the Power Cords” on page 38
■
“Route the SER MGT Cable” on page 39
46Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 47
■
“Install the Switch” on page 40
Install the CMB
Installing the Switch47
Page 48
48Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 49
Connecting Cables
These topics provide cabling information and describe how to cable the switch.
DescriptionLinks
Understand cable requirements.“Cable Requirements” on page 49
Identify cable differences.“Standard MT and PrizmMT Cables” on page 50
Heed cable precautions.“Cable Precautions” on page 52
If necessary, assemble the optical data cables.“Assemble the SFP+ Cables” on page 54
Route the data cables.“Route the Cables” on page 56
Connect the data cables.■ “Connect the RJ-45 Ethernet Cables” on page 57
■ “Connect the PrizmMT Cables” on page 58
■ “Connect the SFP+ Cables” on page 60
Secure the cables to the CMB.“Secure Cables to the CMB” on page 62
Related Information
■
“Understanding the Switch” on page 11
■
“Confirming Specifications” on page 17
■
“Preparing for Installation” on page 23
■
“Installing the Switch” on page 29
■
“Powering On the Switch” on page 67
■
“Verifying Functionality” on page 87
Cable Requirements
Minimal functionality of the switch requires this cabling:
■
Management console – The management console is the physical medium that the
administrator uses to interact with the SP. There are two ways of making this connection:
■
Serial management – A serial device, such as a TIP connection, a serial terminal, or a
terminal server, is cabled to the SER MGT port on the front of the switch. An advantage
of serial management with a dedicated serial terminal is that the connection is more
Connecting Cables49
Page 50
Standard MT and PrizmMT Cables
secure than through network management. Because of the nature of the serial signal,
a serial management cable cannot be used reliably if it is more than 30 feet (9 meters)
long.
■
Network Management – Network management permits you to use your existing
network to connect an SFP+ or RJ-45 cable to any connector on the rear of the switch.
This is the preferred means of connecting to the SP, because it gives you the flexibility
to use any host on the network to interact with the SP and the Oracle ILOM web
interface. To improve security, a VLAN ID can be configured for the SP.
■
Power supplies – Shipped with the switch are country-specific power cords to supply
facility power to the switch from power distribution units inside of the rack.
■
RJ-45 Ethernet ports – These 24 ports provide switched 1GBASE-T functionality through
CAT 6 rated cabling.
■
SFP+ Ethernet ports – These 10 ports provide switched 10GbE functionality with either
copper cables or optical fiber.
■
PrizmMT ports - These 30 ports provide switched 100 Gbps EDR IB functionality with
special optical fiber cables.
Related Information
■
“Standard MT and PrizmMT Cables” on page 50
■
“Cable Precautions” on page 52
■
“Assemble the SFP+ Cables” on page 54
■
“Route the Cables” on page 56
■
“Connect the RJ-45 Ethernet Cables” on page 57
■
“Connect the PrizmMT Cables” on page 58
■
“Connect the SFP+ Cables” on page 60
■
“Secure Cables to the CMB” on page 62
Standard MT and PrizmMT Cables
While PrizmMT and standard MT optical fiber cables look similar, they are not. PrizmMT
cables use clear plastic ferrules that have lenses to focus the laser light across the connection air
gap. Standard MT cables rely upon physical contact of fiber tips at each connection.
Caution - Connecting a PrizmMT cable to a standard MT receptacle, such as on a QSFP
transceiver, will damage the PrizmMT ferrule and render the cable unusable.
To help discriminate between PrizmMT and standard MT cables, PrizmMT cables are identified
with certain features. The features are ferrule, housing color, alignment method, and fiber
spacing.
50Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 51
Standard MT and PrizmMT Cables
TechnologyFerruleHousing
Color
4x PrizmMT optical cablePrizmMT (clear with lenses)MagentaPost and HoleWide
12x PrizmMT optical cablePrizmMT (clear with lenses)BlackPost and HoleWide
4x standard MT optical cableStandard MT (black)AquaPin or HoleNarrow
4x standard MT optical cableStandard MT (black)BlackPin or HoleNarrow
Alignment MethodFiber
Spacing
Note - Some supported cables have a PrizmMT connector on one end, and a standard MT
connector on the other. Pay close attention when connecting this cable, to identify which
connector is which, and not confuse the two.
Visually comparing the design of the two cables, note the differences between the standard MT
cable on the left and the PrizmMT cable on the right.
No.Description
1Aqua colored housing (standard MT)
2Standard ferrule (standard MT)
3Alignment pin holes (standard MT)
4Contact type optical fibers (standard MT)
Connecting Cables51
Page 52
Cable Precautions
No.Description
5Magenta colored housing (PrizmMT)
6Prizm ferrule (PrizmMT)
7Alignment post (PrizmMT)
8Focused optical fiber array (PrizmMT)
9Alignment hole (PrizmMT)
Related Information
■
“Cable Requirements” on page 49
■
“Cable Precautions” on page 52
■
“Assemble the SFP+ Cables” on page 54
■
“Route the Cables” on page 56
■
“Connect the RJ-45 Ethernet Cables” on page 57
■
“Connect the PrizmMT Cables” on page 58
■
“Connect the SFP+ Cables” on page 60
■
“Secure Cables to the CMB” on page 62
Cable Precautions
To prevent data cable damage, you must follow these cautions.
Do not uncoil the cable, as a kink might
occur. Hold the coil closed as you unroll
the cable, pausing to allow the cable to
relax as it is unrolled.
Do not pull the cable out of the shipping
box, through any opening, or around any
corners. Unroll the cable as you lay it
down and move it through turns.
Do not step on the cable or connectors.
Plan cable paths away from foot traffic or
rolling loads.
Do not bend the cables to a radius tighter
than 85 mm (3.4 inches). Ensure that
cable turns are as wide as possible.
52Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 53
Cable Precautions
Do not twist the cable to open a kink. If it
is not severe, open the kink by unlooping
the cable.
Do not straighten the cable to correct a
bend that is too tight. Leave the cable
bend as is.
Do not drop the cable or connectors from
any height. Gently set the cable down,
resting the cable connectors on a stable
surface.
Do not drag the cable or its connectors
over any surface. Carry the entire cable to
and from the points of connection.
Do not pack the cable to fit a tight space.
Use an alternative cable route.
Do not hang the cable for a length
more than 2 meters (7 feet). Minimize
the hanging weight with intermediate
retention points.
Do not cinch the cable with hard fasteners
or cable ties. Use soft hook-and-loop
fastener for bundling and securing cables.
Do not force the cable connector into the
receptacle by pushing on the cable. Apply
connection or disconnection forces at the
connector only.
Related Information
■
“Cable Requirements” on page 49
■
“Standard MT and PrizmMT Cables” on page 50
■
“Assemble the SFP+ Cables” on page 54
■
“Route the Cables” on page 56
■
“Connect the RJ-45 Ethernet Cables” on page 57
■
“Connect the PrizmMT Cables” on page 58
■
“Connect the SFP+ Cables” on page 60
■
“Secure Cables to the CMB” on page 62
Connecting Cables53
Page 54
Assemble the SFP+ Cables
Assemble the SFP+ Cables
If the optical SFP+ cables are unassembled, you must assemble the cables before attaching them
to the switch.
Note - The ends of the optical fiber cable and the receptacles of the transceivers must be clean
and optically clear before assembly. Do not remove the protective caps from the optical fiber
cable or the plugs from the transceivers until instructed to do so.
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Remove the SFP+ optical transceivers and fiber optic cables from their
packaging.
3.
Remove the plug from an SFP+ optical transceiver.
4.
Remove the caps from an LC connector of the fiber optic cable.
5.
Holding the shafts of the LC connector, insert the LC connector into the
receptacles of the SFP+ optical transceiver.
54Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 55
Assemble the SFP+ Cables
Note - The LC connector and SFP+ receptacles are keyed for proper fitting.
6.
Push the connector into the transceiver until it clicks.
7.
Repeat from Step 3 for the other end of the cable.
8.
Repeat from Step 2 for all SFP+ cables to be assembled.
9.
Route the data cables.
See “Route the Cables” on page 56.
Related Information
■
“Cable Requirements” on page 49
■
“Standard MT and PrizmMT Cables” on page 50
■
“Cable Precautions” on page 52
■
“Route the Cables” on page 56
■
“Connect the RJ-45 Ethernet Cables” on page 57
Connecting Cables55
Page 56
Route the Cables
■
“Connect the PrizmMT Cables” on page 58
■
“Connect the SFP+ Cables” on page 60
■
“Secure Cables to the CMB” on page 62
Route the Cables
When cabling a topology, start at the nodes of the fabric or hosts of the network, and work
toward the switch.
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
If necessary, prepare the cables to connect the nodes or hosts to the switch.
See “Assemble the SFP+ Cables” on page 54.
3.
Prepare and verify that the nodes or hosts are operational, properly configured,
and ready to accept fabric or network cabling.
4.
For each node or host, begin data cabling.
a.
Attach the cable to the appropriate connector of the node or host.
b.
Route and bundle the data cable through the topology following the cautions
provided in this document.
See “Cable Precautions” on page 52.
c.
Bring the cables to the location in the rack where the switch is installed.
d.
Repeat Step 4a through Step 4c for each node or host.
5.
Connect the cables to the switch.
See “Connect the RJ-45 Ethernet Cables” on page 57.
Related Information
■
“Cable Requirements” on page 49
■
“Standard MT and PrizmMT Cables” on page 50
■
“Cable Precautions” on page 52
■
“Assemble the SFP+ Cables” on page 54
■
“Connect the RJ-45 Ethernet Cables” on page 57
■
“Connect the PrizmMT Cables” on page 58
56Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 57
■
“Connect the SFP+ Cables” on page 60
■
“Secure Cables to the CMB” on page 62
Connect the RJ-45 Ethernet Cables
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Orient the RJ-45 connector to where it will connect to the switch.
The tab is up for the upper row of receptacles, and the tab is down for the lower row of
receptacles.
Connect the RJ-45 Ethernet Cables
3.
Insert the connector into the receptacle until it clicks, securing it in place.
4.
Lay the cable into a slot on the CMB.
5.
Repeat Step 2 through Step 4 for each cable to be connected.
6.
Consider your next task.
■Connect the PrizmMT cables if necessary.
See “Connect the PrizmMT Cables” on page 58.
■Connect the SFP+ cables if necessary.
See “Connect the SFP+ Cables” on page 60.
Connecting Cables57
Page 58
Connect the PrizmMT Cables
■Secure the cables to the CMB.
See “Secure Cables to the CMB” on page 62.
Related Information
■
“Cable Requirements” on page 49
■
“Standard MT and PrizmMT Cables” on page 50
■
“Cable Precautions” on page 52
■
“Assemble the SFP+ Cables” on page 54
■
“Route the Cables” on page 56
■
“Connect the PrizmMT Cables” on page 58
■
“Connect the SFP+ Cables” on page 60
■
“Secure Cables to the CMB” on page 62
Connect the PrizmMT Cables
Note - PrizmMT receptacles labeled 1 through 26 are for 4x magenta-colored housing PrizmMT
cables. PrizmMT receptacles labeled 27 through 30 are for 12x black-colored housing PrizmMT
cables.
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Remove any filler plug (if installed) from the PrizmMT receptacle where you are
installing the cable and visually inspect the receptacle.
The receptacle should be clean and free of dirt or debris.
3.
If the receptacle is dirty, clean it.
a.
Remove the adapter from the end of the PrizmMT cleaner.
b.
Insert the cleaner tip into the receptacle.
c.
Pump the cleaner into the receptacle, advancing the cleaning cloth inside.
d.
Remove the cleaner from the receptacle and verify cleanliness.
e.
Repeat from Step 3b if the fibers are still dirty.
58Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 59
Connect the PrizmMT Cables
f.
Replace the adapter onto the end of the PrizmMT cleaner.
4.
Remove the protective cap from the cable connector and visually inspect the
connector.
The connector should be clean and free of dirt or debris.
5.
If the connector is dirty, clean it.
a.
Open the lid of the adapter on the end of the PrizmMT cleaner.
b.
Insert the connector into the adapter.
c.
Press the connector against the adapter, thereby pumping the cleaner, and
advancing the cleaning cloth inside.
d.
Remove the connector from the adapter and verify cleanliness.
e.
Repeat from Step 5b if the fibers are still dirty.
f.
Close the lid of the adapter on the end of the PrizmMT cleaner.
6.
Align the PrizmMT connector to where it will connect.
7.
Firmly press the PrizmMT connector into the receptacle until you feel a detent.
Connecting Cables59
Page 60
Connect the SFP+ Cables
8.
Lay the cable into a slot on the CMB.
9.
Repeat Step 2 through Step 8 for each cable to be connected.
10.
Consider your next task.
■Connect the SFP+ cables if necessary.
■Secure the cables to the CMB.
Related Information
■
■
■
■
■
■
■
■
See “Connect the SFP+ Cables” on page 60.
See “Secure Cables to the CMB” on page 62.
“Cable Requirements” on page 49
“Standard MT and PrizmMT Cables” on page 50
“Cable Precautions” on page 52
“Assemble the SFP+ Cables” on page 54
“Route the Cables” on page 56
“Connect the RJ-45 Ethernet Cables” on page 57
“Connect the SFP+ Cables” on page 60
“Secure Cables to the CMB” on page 62
Connect the SFP+ Cables
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Remove the protective cap from the connector or transceiver and visually
inspect the cable connector.
The shell should not be bent and should be parallel to the inner boards. If the connector is bent
or damaged, use a different cable.
3.
Ensure that the retraction strap is folded back against the cable.
4.
Orient the cable connector to the SFP+ receptacle squarely and horizontally.
60Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 61
Connect the SFP+ Cables
Ensure that the L groove is up for the top row of receptacles, or that the L groove is down for
the bottom row of receptacles.
5.
Slowly move the connector in.
As you slide the connector in, the shell should be in the center of the SFP+ receptacle.
■If the connector stops or binds after about 1/4 in. (5 mm) travel, back out and
repeat from Step 4.
■If the connector stops or binds with about 1/8 in. (2 mm) still to go, back out
and repeat Step 5.
6.
Continue to push the connector in until you feel a detent.
7.
Lay the cable into a slot on the CMB.
8.
Repeat Step 2 through Step 7 for each cable to be connected.
9.
Secure the cables to the CMB.
Connecting Cables61
Page 62
Secure Cables to the CMB
See “Secure Cables to the CMB” on page 62.
Related Information
■
“Cable Requirements” on page 49
■
“Standard MT and PrizmMT Cables” on page 50
■
“Cable Precautions” on page 52
■
“Assemble the SFP+ Cables” on page 54
■
“Route the Cables” on page 56
■
“Connect the RJ-45 Ethernet Cables” on page 57
■
“Connect the PrizmMT Cables” on page 58
■
“Secure Cables to the CMB” on page 62
Secure Cables to the CMB
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
62Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 63
Secure Cables to the CMB
2.
While connecting the RJ-45, SFP+, and PrizmMT cables to the switch, lay the
cables into an available slot on the CMB.
Connecting Cables63
Page 64
Secure Cables to the CMB
3.
After all cables have been laid, replace the cover for the CMB and tighten the
thumbscrews.
4.
Route the data cables so that they do not interfere with other cables, or with
servicing the switch or other systems.
Use hook and loop fastener straps to bundle and secure the cables.
Note - Do not use cable zip ties to bundle or secure the cables, because the ties damage the
fibers inside the cables.
5.
Retrieve the power cords and SER MGT cable (if previously routed) for
connection to the switch.
See “Retrieve the Power Cords and SER MGT Cable” on page 67.
Related Information
■
“Cable Requirements” on page 49
■
“Standard MT and PrizmMT Cables” on page 50
■
“Cable Precautions” on page 52
■
“Assemble the SFP+ Cables” on page 54
■
“Route the Cables” on page 56
64Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 65
■
“Connect the RJ-45 Ethernet Cables” on page 57
■
“Connect the PrizmMT Cables” on page 58
■
“Connect the SFP+ Cables” on page 60
Secure Cables to the CMB
Connecting Cables65
Page 66
66Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 67
Powering On the Switch
These topics describe how to power on the switch for the first time.
DescriptionLinks
Retrieve the power cords and SER
MGT cable.
Connect the serial management
device.
Connect the power cords.“Connect the Power Cords” on page 74
If you have a full-time SER MGT
connection, install the air duct.
Power on the switch.“Power On the Switch” on page 78
If you are not using DHCP-assigned
IP addresses, log in to the service
processor (SP) through the SER
MGT connection.
Assign a static IP address to the SP“Assign a Static IP Address to the SP” on page 80
Assign a static IP address to the SCP “Assign a Static IP Address to the SCP” on page 82
Log in to the SP again“Log In to the SP (Network Management)” on page 84
“Retrieve the Power Cords and SER MGT Cable” on page 67
■ “Connect the SER MGT Cable” on page 71
■ “Connect a Serial Management Device to the SER MGT
Port” on page 74
“Install the Air Duct Assembly” on page 76
“Log In to the SP (SER MGT)” on page 79
Related Information
■
“Understanding the Switch” on page 11
■
“Confirming Specifications” on page 17
■
“Preparing for Installation” on page 23
■
“Installing the Switch” on page 29
■
“Connecting Cables” on page 49
■
“Verifying Functionality” on page 87
Retrieve the Power Cords and SER MGT Cable
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
Powering On the Switch67
Page 68
Retrieve the Power Cords and SER MGT Cable
See “Installation Task Overview” on page 11.
2.
Take the paper clip and lift the smaller loop away from the larger loop.
3.
Continue to open the paper clip and fold the smaller loop over, so that the paper
clip now resembles the letter S.
4.
Open the larger loop approximately 45 degrees to form a hook.
5.
Holding the smaller loop, insert the larger loop into the opening of the long front
mounting bracket, to hook the power cord hanging inside.
68Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 69
Retrieve the Power Cords and SER MGT Cable
6.
Pull the power cord through the opening, until you can grasp it with your fingers.
7.
Pull the cord through so that the end of the cord is free.
8.
Repeat Step 5 through Step 7 for the other power cord.
9.
If you will have a full-time SER MGT connection, repeat Step 5 through Step 7 for
the SER MGT cable.
Powering On the Switch69
Page 70
Retrieve the Power Cords and SER MGT Cable
Note - When pulling the SER MGT cable, be careful not to break the tab of the RJ-45
connector.
10.
Consider your next steps.
■If you have DHCP-assigned IP addresses, connect the power cords.
See “Connect the Power Cords” on page 74.
■Otherwise, connect the SER MGT cable.
See “Connect the SER MGT Cable” on page 71.
Related Information
■
“Connect the SER MGT Cable” on page 71
■
“Connect a Serial Management Device to the SER MGT Port” on page 74
■
“Connect the Power Cords” on page 74
■
“Install the Air Duct Assembly” on page 76
70Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 71
■
“Power On the Switch” on page 78
■
“Log In to the SP (SER MGT)” on page 79
■
“Assign a Static IP Address to the SP” on page 80
■
“Assign a Static IP Address to the SCP” on page 82
■
“Log In to the SP (Network Management)” on page 84
Connect the SER MGT Cable
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Consider your next step.
■If the SER MGT cable will be a full-time connection, go to Step 3.
Connect the SER MGT Cable
■If the SER MGT connection will only be temporary for installation, go to Step
5.
3.
Pass the end of the SER MGT cable through the opening on the side of the air
duct assembly.
■If the SER MGT cable is on the left, pass the cable from the outside, through
the opening on the left side (no Oracle logo) in to the center.
Powering On the Switch71
Page 72
Connect the SER MGT Cable
■If the SER MGT cable is on the right, pass the cable from the outside,
through the opening on the right side (Oracle logo) in to the center.
4.
Continue to pull the cable through the air duct assembly to take up the slack.
5.
Orient the RJ-45 connector to the SER MGT receptacle at the front of the switch,
adjacent to the left power supply.
72Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 73
The tab is up for the receptacle.
Connect the SER MGT Cable
6.
Insert the connector into the receptacle until it clicks, securing it in place.
7.
Connect the other end of the SER MGT cable to a serial device.
See “Connect a Serial Management Device to the SER MGT Port” on page 74.
Related Information
■
“Retrieve the Power Cords and SER MGT Cable” on page 67
■
“Connect a Serial Management Device to the SER MGT Port” on page 74
■
“Connect the Power Cords” on page 74
■
“Install the Air Duct Assembly” on page 76
■
“Power On the Switch” on page 78
■
“Log In to the SP (SER MGT)” on page 79
■
“Assign a Static IP Address to the SP” on page 80
■
“Assign a Static IP Address to the SCP” on page 82
■
“Log In to the SP (Network Management)” on page 84
Powering On the Switch73
Page 74
Connect a Serial Management Device to the SER MGT Port
Connect a Serial Management Device to the SER MGT
Port
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Configure the serial management device to these parameters:
■
9600 baud
■
8 data bits
■
No parity
■
1 stop bit
■
No handshake
3.
Connect the SER MGT cable from the switch to the serial management device.
4.
If necessary, route the SER MGT cable so that it does not interfere with other
cables, with servicing the switch, or with other systems.
5.
Connect the power cords.
See “Connect the Power Cords” on page 74.
Related Information
■
“Retrieve the Power Cords and SER MGT Cable” on page 67
■
“Connect the SER MGT Cable” on page 71
■
“Connect the Power Cords” on page 74
■
“Install the Air Duct Assembly” on page 76
■
“Power On the Switch” on page 78
■
“Log In to the SP (SER MGT)” on page 79
■
“Assign a Static IP Address to the SP” on page 80
■
“Assign a Static IP Address to the SCP” on page 82
■
“Log In to the SP (Network Management)” on page 84
Connect the Power Cords
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
74Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 75
Connect the Power Cords
See “Installation Task Overview” on page 11.
2.
Ensure that the circuit breakers for the facility power receptacle or power
distribution device are switched off.
3.
Plug the power cords into the receptacles at the front of the switch chassis.
4.
Plug each power cord into the facility power receptacle or power distribution
device.
Note - To provide redundancy, connect each power cord to a separate power source. The switch
can operate with only one power source, but there is no redundancy in that case.
Caution - Do not apply power at this time.
5.
Consider your next steps.
■If you have DHCP-assigned IP addresses, install the air duct assembly.
Powering On the Switch75
Page 76
Install the Air Duct Assembly
See “Install the Air Duct Assembly” on page 76.
■If you have a full-time SER MGT connection, install the air duct assembly.
See “Install the Air Duct Assembly” on page 76.
■If your SER MGT connection is only temporary, power on the switch.
See “Power On the Switch” on page 78.
Related Information
■
“Retrieve the Power Cords and SER MGT Cable” on page 67
■
“Connect the SER MGT Cable” on page 71
■
“Connect a Serial Management Device to the SER MGT Port” on page 74
■
“Install the Air Duct Assembly” on page 76
■
“Power On the Switch” on page 78
■
“Log In to the SP (SER MGT)” on page 79
■
“Assign a Static IP Address to the SP” on page 80
■
“Assign a Static IP Address to the SCP” on page 82
■
“Log In to the SP (Network Management)” on page 84
Install the Air Duct Assembly
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Ensure that the power cords and SER MGT cable (if attached) are out of the way
and will not interfere with installing the air duct assembly.
Tuck the power cord slack into the opening of the long front mounting bracket. Tuck the SER
MGT cable slack into the cavity of the air duct assembly.
3.
Lift the air duct assembly to where it installs on the switch.
76Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 77
Install the Air Duct Assembly
Though the air duct assembly is symmetrical, the logo, if present, goes to the right.
4.
Push the air duct assembly in to the front of the switch, until it snaps into place.
5.
Consider your next steps.
■If you have DHCP-assigned IP addresses, power on the switch.
See “Power On the Switch” on page 78.
■If you have a full-time SER MGT connection, power on the switch.
See “Power On the Switch” on page 78.
■If your SER MGT connection was only temporary, verify the switch
installation.
See “Verify LED Status” on page 87.
Related Information
■
“Retrieve the Power Cords and SER MGT Cable” on page 67
Powering On the Switch77
Page 78
Power On the Switch
■
“Connect the SER MGT Cable” on page 71
■
“Connect a Serial Management Device to the SER MGT Port” on page 74
■
“Connect the Power Cords” on page 74
■
“Power On the Switch” on page 78
■
“Log In to the SP (SER MGT)” on page 79
■
“Assign a Static IP Address to the SP” on page 80
■
“Assign a Static IP Address to the SCP” on page 82
■
“Log In to the SP (Network Management)” on page 84
Power On the Switch
When live power is delivered to the receptacles at the rear of the chassis, standby and main
power is made available by the power supplies. The switch immediately comes to full power.
Both the SP and SCP begin their boot processes.
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Ensure that:
■
The nodes of the IB fabric and hosts of the Ethernet network are operational and securely
cabled to the switch.
■
The serial management console is operational, configured with correct parameters,
and cabled to the switch. See “Connect a Serial Management Device to the SER MGT
Port” on page 74.
■
The management network is operational and securely cabled to the switch.
■
The facility power source or power distribution device is properly cabled to the switch,
available, and standing by.
■
All data, management, and power cabling to the switch is secure at the switch.
3.
Energize the circuit breakers so that facility power is delivered to the switch.
These actions occur in order:
■
All chassis status LEDs illuminate, then go dark.
■
The power supply LEDs indicate input power, then output power.
■
The fans spin up to maximum speed.
Note - Over the next few minutes, the fans gradually decrease in speed.
■
Full power is applied to all circuits and systems inside the switch.
78Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 79
Log In to the SP (SER MGT)
■
Both the SP and SCP are powered on and booting up.
Note - You might see the boot sequence on the serial device.
■
The SP LED slow blinks.
When the SP LED stops blinking and stays lit, and the OK LED lights, it is possible to log in to
the SP.
4.
Consider your next steps.
■If you have DHCP-assigned IP addresses, log in to the SP through the
network.
See “Log In to the SP (Network Management)” on page 84.
■Otherwise, log in to the SP through the SER MGT port.
See “Log In to the SP (SER MGT)” on page 79.
Related Information
■
“Retrieve the Power Cords and SER MGT Cable” on page 67
■
“Connect the SER MGT Cable” on page 71
■
“Connect a Serial Management Device to the SER MGT Port” on page 74
■
“Connect the Power Cords” on page 74
■
“Install the Air Duct Assembly” on page 76
■
“Log In to the SP (SER MGT)” on page 79
■
“Assign a Static IP Address to the SP” on page 80
■
“Assign a Static IP Address to the SCP” on page 82
■
“Log In to the SP (Network Management)” on page 84
Log In to the SP (SER MGT)
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
On the serial management device, press the Return or Enter key several times to
synchronize the connection.
The login prompt is displayed.
hostname login:
Powering On the Switch79
Page 80
Assign a Static IP Address to the SP
where hostname is the host name of the SP. If no host name is assigned, ORACLESP-unknown
might be displayed.
3.
Log in to the SP.
hostname login: root
Password: changeme
->
The -> prompt is displayed.
Note - You can change the password at a later time. Refer to the Oracle EDR InfiniBand Switch
and Virtualized I/O Systems Administration Guide, changing the administrator password.
4.
Consider your next task.
■If you have a full-time SER MGT connection, go to “Verify LED
Status” on page 87 or “Assign a Static IP Address to the
SP” on page 80.
■If your SER MGT connection is only temporary, go to “Assign a Static IP
Address to the SP” on page 80.
Related Information
■
“Retrieve the Power Cords and SER MGT Cable” on page 67
■
“Connect the SER MGT Cable” on page 71
■
“Connect a Serial Management Device to the SER MGT Port” on page 74
■
“Connect the Power Cords” on page 74
■
“Install the Air Duct Assembly” on page 76
■
“Power On the Switch” on page 78
■
“Assign a Static IP Address to the SP” on page 80
■
“Assign a Static IP Address to the SCP” on page 82
■
“Log In to the SP (Network Management)” on page 84
Assign a Static IP Address to the SP
The switch ships with DHCP IP address assignment for the SP.
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
80Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 81
2.
Access the Oracle ILOM CLI.
See “Log In to the SP (SER MGT)” on page 79.
3.
Configure the network management parameters.
-> set /SP/network property=valueproperty=value ...
where:
■
property is the parameter of the network to configure.
■
value is the value of the property to configure.
These properties are supported:
■
pendingipaddress – value is the IP address of the SP to be configured.
■
pendingipdiscovery – value is the method of IP discovery to be configured, either static
or dhcp.
■
pendingipgateway – value is the IP address of the routing gateway to be configured.
■
pendingipnetmask – value is the netmask to be configured.
Assign a Static IP Address to the SP
Note - You can configure one, several, or all properties in one command line.
For example:
-> set /SP/network pendingipdiscovery=static pendingipaddress=123.45.67.89
pendingipgateway=123.45.67.1 pendingipnetmask=255.255.255.0
Set 'pendingipdiscovery' to 'static'
Set 'pendingipaddress' to '123.45.67.89'
Set 'pendingipgateway' to '123.45.67.1'
Set 'pendingipnetmask' to '255.255.255.0'
->
4.
Commit the changes.
-> set /SP/network commitpending=true
Set 'commitpending' to 'true'
->
The static IP address has been configured to 123.45.67.89. You can now manage the SP from
any one of the RJ-45 connectors on the rear panel.
5.
Consider your next steps.
■Configure a static IP address for the SCP.
See “Assign a Static IP Address to the SCP” on page 82.
■Log in to the SP through the management network.
Powering On the Switch81
Page 82
Assign a Static IP Address to the SCP
See “Log In to the SP (Network Management)” on page 84.
Related Information
■
“Retrieve the Power Cords and SER MGT Cable” on page 67
■
“Connect the SER MGT Cable” on page 71
■
“Connect a Serial Management Device to the SER MGT Port” on page 74
■
“Connect the Power Cords” on page 74
■
“Install the Air Duct Assembly” on page 76
■
“Power On the Switch” on page 78
■
“Log In to the SP (SER MGT)” on page 79
■
“Assign a Static IP Address to the SCP” on page 82
■
“Log In to the SP (Network Management)” on page 84
Assign a Static IP Address to the SCP
The switch ships with DHCP IP address assignment for the SCP.
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Access the Oracle ILOM CLI.
See “Log In to the SP (SER MGT)” on page 79 or “Log In to the SP (Network
Management)” on page 84.
3.
Start the host console.
-> start /HOST/console
Are you sure you want to start /HOST/console (y/n)? y
Serial console started. To stop, type ESC (
4.
Press the Enter key.
Oracle Linux Server release 6.6
Kernel 4.0.4-15.el6uek.x86_64 on an x86_64
hostname login:
5.
Log in as the root user.
hostname login: root
Password:password
Last login: Fri May 25 09:51:36 on ttyS0
82Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
where SCP_IP_address is the IP address to be assigned to the SCP. Alternatively, you can
configure IP address assignment by DHCP or Oracle ILOM. If you provide a static IP address,
you will also need to provide the netmask and the IP address of the management network
gateway. For example:
[root@hostname ~]# nm3tool ipaddress 123.45.67.90
Enter netmask: 255.255.255.0
Enter default gateway: 123.45.67.1
Restart network now? (Y/n)
7.
Restart the network to use the new values.
Restart network now? (Y/n)Y
Shutting down interface eth0: [ OK ]
Shutting down interface eth1: [ OK ]
Shutting down loopback interface: [ OK ]
Bringing up loopback interface: [ OK ]
Bringing up interface eth0:
Determining IP information for eth0... done.
[ OK ]
Bringing up interface eth1: Determining if ip address 169.254.2.1 is already in use for
device eth1...
[ OK ]
[root@hostname ~]#
8.
(Optional) Set the hostname.
Provide the new host name. For example:
[root@hostname ~]# nm3tool hostnamehostname
where hostname is the host name of the SCP. For example:
/System | health | OK
/System/Power | health | OK
/System/Power/Power_Supplies/Power_Supply_0 | health | OK
/System/Power/Power_Supplies/Power_Supply_1 | health | OK
/System/Cooling | health | OK
/System/Cooling/Fans/Fan_0 | health | OK
/System/Cooling/Fans/Fan_1 | health | OK
/System/Cooling/Fans/Fan_2 | health | OK
/System/Cooling/Fans/Fan_3 | health | OK
/System/Cooling/Fans/Fan_4 | health | OK
/System/Cooling/Fans/Fan_5 | health | OK
/System/Cooling/Fans/Fan_6 | health | OK
/System/Cooling/Fans/Fan_7 | health | OK
/System/Networking | health | OK
/System/Networking/Switches/Switch_0 | health | OK
/System/Networking/Switches/Switch_1 | health | OK
->
4.
If any target has a health value other than OK, investigate why.
Refer to Switch Service, detecting and managing faults.
If any open problems are discovered, investigate the problem.
Refer to Switch Service, detecting and managing faults.
7.
Verify the switch's connectivity to the IB fabric and Ethernet network.
See “Verify Connectivity” on page 91.
Related Information
■
“Verify LED Status” on page 87
■
“LED Status” on page 88
90Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 91
■
“Verify Connectivity” on page 91
■
“Log In to the Oracle Fabric Manager Interface” on page 94
■
“Log In to the Oracle Fabric OS Interface” on page 96
■
“Run the Oracle Fabric OS Configuration Wizard” on page 97
■
“Oracle Fabric OS Configuration Wizard Parameters” on page 98
Verify Connectivity
1.
Identify the prerequisite and subsequent installation tasks that you must
perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
If you are at the switch, check the Link LEDs of the SFP+ and RJ-45 connectors.
See “LED Status” on page 88 for a description of Link LED states.
3.
Access the Oracle ILOM CLI.
See “Log In to the SP (SER MGT)” on page 79 or “Log In to the SP (Network
Management)” on page 84.
Verify Connectivity
4.
Verify Ethernet connectivity.
a.
Start the EMS console.
-> start /System/Networking/Switches/Switch_0/fs_cli
Are you sure you want to start /System/Networking/Switches/Switch_0/fs_cli
(y/n)? y
Management Switch for Oracle InfiniBand Switch IS2-46
SEFOS login:
b.
Log in to SEFOS.
SEFOS login: root
Password: password
SEFOS#
The default password is admin123.
c.
Display the state of the Ethernet ports.
SEFOS# show interfaces status
Port Status Duplex Speed Negotiation Capability
---- ------ ------ ----- ----------- ---------Gi0/1 not connected Half - Auto Auto-MDIX on
Gi0/2 connected Full 1 Gbps Auto Auto-MDIX on
Verifying Functionality91
Page 92
Verify Connectivity
Gi0/3 connected Full 1 Gbps Auto Auto-MDIX on
Gi0/4 not connected Half - Auto Auto-MDIX on
Gi0/5 not connected Half - Auto Auto-MDIX on
Gi0/6 connected Full 1 Gbps Auto Auto-MDIX on
Gi0/7 not connected Half - Auto Auto-MDIX on
...
Gi0/13 connected Full 1 Gbps Auto Auto-MDIX on
...
Gi0/23 not connected Half - Auto Auto-MDIX on
Gi0/23 connected Full 1 Gbps Auto Auto-MDIX on
Gi0/25 connected Full 1 Gbps Auto Auto-MDIX on
Gi0/26 connected Full 1 Gbps Auto Auto-MDIX on
Ex0/1 not connected Full 10 Gbps No-Negotiation Auto-MDIX on
Ex0/2 not connected Full 10 Gbps No-Negotiation Auto-MDIX on
SEFOS#
In the output, Port is the port as seen on the rear panel. Ports Gi0/25 and Gi0/26 are
internal to the switch architecture. Ports Ex0/1 and Ex0/2 are the two SFP+ uplink
ports. The Status is the state of the port. The Duplex, Speed, and Negotiation are the
parameters of the link. The Capability indicates if auto-crossover capability is on.
d.
If the status of a known-connected port is anything other than connected,
investigate why.
Refer to the EMS module documentation.
e.
Exit the EMS console.
SEFOS# exit
Connection closed by foreign host
Entering character mode
Escape character is '^]'.
start: The session with /System/Networking/Switches/Switch_0/fs_cli has ended.
->
5.
Verify IB and gateway connectivity.
a.
Start the host console.
-> start /HOST/console
Are you sure you want to start /HOST/console (y/n)? y
Serial console started. To stop, type ESC (
b.
Press Enter.
[user@hostname ~]#
where:
92Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 93
Verify Connectivity
■
user is the current username.
■
hostname is the host name of the SCP.
c.
Switch to user admin with password admin.
[user@hostname ~]# su admin
Welcome to IBOS Controller
Copyright (c) 2012-2015 Oracle Corp. All rights reserved.
Enter "help" for information on available commands.
Enter the command "show system copyright" for licensing information
admin@hostname[OFOS]
Note - From here forward in this document, the admin@hostname[OFOS] prompt is replaced
with simply [OFOS].
If this is the first time Oracle Fabric OS is accessed, the Oracle Fabric OS configuration
wizard might start. If this happens, see “Run the Oracle Fabric OS Configuration
Wizard” on page 97.
d.
Display the state of the gateway ports.
[OFOS] show ioports
name type state descr v-resources
In the output, the name is the port number as seen on the rear panel. The state is of the
local port/peer port. The descr is the node descriptor of the peer port. The v-resources
are the number of VLANs and VNICs supported on that port.
e.
Display the state of the IB ports.
[OFOS] show infiniband-port
name state mode_state guid
In the output, the name is the port number as seen on the rear panel. The state is of the
local port/peer port. The mode_state is the condition of the link. The guid is the GUID of
the peer port.
f.
If in the output of these commands a port is identified as being in a down
state, or if a link mode_state is other than switching, investigate why.
Refer to the Oracle Fabric OS documentation for assistance.
g.
Exit the host console.
Type exit and press the Enter key, then press the Esc key and type (.
[OFOS] exit
[root@nsn156-168 ~]#
Serial console stopped.
->
6.
Administer the switch from Oracle Fabric Manager or Oracle Fabric OS.
See “Log In to the Oracle Fabric Manager Interface” on page 94 or “Log In to the Oracle
Fabric OS Interface” on page 96.
Related Information
■
“Verify LED Status” on page 87
■
“LED Status” on page 88
■
“Verify That the Switch Is Operational” on page 89
■
“Log In to the Oracle Fabric Manager Interface” on page 94
■
“Log In to the Oracle Fabric OS Interface” on page 96
■
“Run the Oracle Fabric OS Configuration Wizard” on page 97
■
“Oracle Fabric OS Configuration Wizard Parameters” on page 98
Log In to the Oracle Fabric Manager Interface
1.
From a management network attached host, start a web browser.
94Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 95
Log In to the Oracle Fabric Manager Interface
2.
Log in to Oracle Fabric Manager.
https://SCP_IP_address:8443/xms
where SCP_IP_address is the IP address of the SCP you configured in “Assign a Static IP
Address to the SCP” on page 82.
The Oracle Fabric Manager login page is displayed.
3.
Type the username and password of the Oracle Fabric Manager administrator.
The default username is root, and the password is changeme.
4.
Select a language from the drop-down menu and click Log In.
The Fabric Manager Dashboard is displayed.
5.
From the Navigation pane, open the Managed Devices folder, and click
Discovery Devices.
6.
Find the switch in the list of devices, and highlight it.
7.
Click the check mark icon.
8.
Type the user name and password, and click Submit.
The default username is admin, and the password is admin.
The Discovery Devices pane updates, and the green circle checkmark in the Manage Status
column indicates that the switch is enabled for management.
9.
From the Navigation pane, open the General folder, and click Dashboard.
The Navigation pane and Fabric Manager Dashboard reload with additional functionality.
10.
You can now administer the switch through Oracle Fabric Manager.
Refer to the Oracle Fabric Manager documentation for further instructions.
Related Information
■
“Verify LED Status” on page 87
■
“LED Status” on page 88
■
“Verify That the Switch Is Operational” on page 89
■
“Verify Connectivity” on page 91
■
“Log In to the Oracle Fabric OS Interface” on page 96
■
“Run the Oracle Fabric OS Configuration Wizard” on page 97
■
“Oracle Fabric OS Configuration Wizard Parameters” on page 98
Verifying Functionality95
Page 96
Log In to the Oracle Fabric OS Interface
Log In to the Oracle Fabric OS Interface
When you log in to the Oracle Fabric OS interface for the very first time, the Oracle Fabric OS
configuration wizard starts.
1.
From a management network attached host, start an SSH session.
Last login: Wed Jun 13 22:50:04 2012 from sca-ss-01.us.oracle.com
Welcome to OFOS Controller
Copyright (c) 2012-2015 Oracle Corp. All rights reserved.
Enter "help" for information on available commands.
Enter the command "show system copyright" for licensing information
user@hostname[OFOS]
where:
■
user is the username of the Oracle Fabric OS administrator. The default is admin.
■
password is the password of the Oracle Fabric OS administrator. The default is admin.
■
SCP_IP_address is the IP address you configured in “Assign a Static IP Address to the
SCP” on page 82.
■
hostname is the host name you configured in “Assign a Static IP Address to the
SCP” on page 82.
2.
Consider your next steps.
■If this is the first login to Oracle Fabric OS, the Oracle Fabric OS
configuration wizard runs automatically.
See “Run the Oracle Fabric OS Configuration Wizard” on page 97.
■Otherwise, you can now administer the switch through Oracle Fabric OS.
Refer to the Oracle Fabric OS documentation for further instructions.
Related Information
■
“Verify LED Status” on page 87
■
“LED Status” on page 88
■
“Verify That the Switch Is Operational” on page 89
■
“Verify Connectivity” on page 91
■
“Log In to the Oracle Fabric Manager Interface” on page 94
■
“Run the Oracle Fabric OS Configuration Wizard” on page 97
■
“Oracle Fabric OS Configuration Wizard Parameters” on page 98
96Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 97
Run the Oracle Fabric OS Configuration Wizard
Run the Oracle Fabric OS Configuration Wizard
Caution - Running the Oracle Fabric OS configuration wizard destroys data. If you are
manually running the wizard, consider backing up configuration data before proceeding.
1.
Consider your first step.
■If the Oracle Fabric OS configuration wizard has started automatically, go to
Step 2.
■If you want to manually run the Oracle Fabric OS configuration wizard, at the
Oracle Fabric OS prompt, type:
[OFOS} system clear config
This is a destructive operation. Your configuration will be cleared and the
system will be restarted. Please type 'confirm' to clear the configuration and
restart the system.
> confirm
2.
Review the parameters that the Oracle Fabric OS configuration wizard requests.
See “Oracle Fabric OS Configuration Wizard Parameters” on page 98.
3.
Permit the Oracle Fabric OS configuration wizard to run.
Type Y.
4.
Answer the questions as the wizard requests.
When completed, the wizard reboots Oracle Fabric OS.
5.
Log in to Oracle Fabric OS with the newly configured values.
See “Log In to the Oracle Fabric OS Interface” on page 96.
Related Information
■
“Verify LED Status” on page 87
■
“LED Status” on page 88
■
“Verify That the Switch Is Operational” on page 89
■
“Verify Connectivity” on page 91
■
“Log In to the Oracle Fabric Manager Interface” on page 94
■
“Log In to the Oracle Fabric OS Interface” on page 96
■
“Oracle Fabric OS Configuration Wizard Parameters” on page 98
Verifying Functionality97
Page 98
Oracle Fabric OS Configuration Wizard Parameters
Oracle Fabric OS Configuration Wizard Parameters
ParameterValue
What type of switch is this?Choose from displayed
Do you want to enable a strong password configuration?Yes/No
If yes, what is the minimum number of characters in the password?1 - 8
If yes, what is the minimum number of lower case letters in the password?1 - 8
If yes, what is the minimum number of digits in the password?1 - 8
If yes, what is the minimum number of special characters in the password?1 - 8
If yes, what is the minimum number of upper case letters in the password?1 - 8
What is the password for the admin user?
What is the OSDN MAC address?Choose from displayed
Related Information
■
“Verify LED Status” on page 87
■
“LED Status” on page 88
■
“Verify That the Switch Is Operational” on page 89
■
“Verify Connectivity” on page 91
■
“Log In to the Oracle Fabric Manager Interface” on page 94
■
“Log In to the Oracle Fabric OS Interface” on page 96
■
“Run the Oracle Fabric OS Configuration Wizard” on page 97
Enter the admin password
98Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Page 99
Glossary
1
10GBASE-T –LREthernet technology that supports cable distances of over 300 meters.
10GBASE-T –SRStandard 10GbE Ethernet technology.
10GbE/40GbE
module
16G Fibre
Channel
module
I/O module for the Oracle Fabric Interconnect F2-12 that supports 10GbE and 40GbE
interfaces.
I/O module for the Oracle Fabric Interconnect F2-12 that supports Fibre Channel interfaces.
A
ADAbbreviation for Active Directory.
adapterPhysical device, such as an HCA or NIC, that enables a host to communicate through a fabric
or network.
ASRAutomatic Service Request. A feature of Oracle hardware that automatically opens service
requests when specific hardware faults occur. ASR is integrated with My Oracle Support
(MOS) and requires a support agreement. See also MOS.
C
CFMCubic feet per minute. A standard of measuring airflow.
CMBAbbreviation for cable management bracket. A component that supports and groups cables
extending from the chassis.
Glossary99
Page 100
DN
D
DNAbbreviation for distinguished name. An Active Directory term.
DSA keyDigital Signature Algorithm key. A component of SSH authentication. See also RSA and SSH.
E
EDRExtended Data Rate. A throughput of InfiniBand (IB) technology, typically 100Gbps. See also
IB.
EMS moduleEmbedded Management Switch module. A component within the switch chassis that provides
an Ethernet switch and management controller, using the SEFOS operating system. See also
SEFOS.
Ethernet
gateway
Ethernet
management
switch
A device that either enables data transference from one protocol to another, for example IB to
Ethernet. Or a device that serves as a routing node for an Ethernet network.
An Ethernet switch that enables single point management of multiple service processors (SP) or
hosts through their respective network management interfaces. See also SP.
F
fabric cardA component of an IB switch chassis that provides a spine topology construct. See also IB
SFM module.
fabric
interconnect
fan moduleA hot-swappable replaceable component that provides cooling air to the chassis interior.
Fibre ChannelA data transference technology used primarily for storage systems.
FMAbbreviation of fan module. See also fan module.
Short name for an IB switch that provides gateway services and additional functionality.
G
GBAbbreviation of GigaByte. 1 GB is approximately 1000 MB.
GbEAbbreviation of Gigabit Ethernet. A unit of throughput for Ethernet technology.
100Oracle InfiniBand Switch IS2-46 Installation Guide • September 2016
Loading...