Oracle Fabric Interconnect F2-12 Installation Manual

Page 1

Oracle® Fabric Interconnect F2-12 Installation Guide

Part No: E74400-01
November 2016
Page 2
Page 3
Oracle Fabric Interconnect F2-12 Installation Guide
Part No: E74400-01
This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws. Except as expressly permitted in your license agreement or allowed by law, you may not use, copy, reproduce, translate, broadcast, modify, license, transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any means. Reverse engineering, disassembly, or decompilation of this software, unless required by law for interoperability, is prohibited.
The information contained herein is subject to change without notice and is not warranted to be error-free. If you find any errors, please report them to us in writing.
If this is software or related documentation that is delivered to the U.S. Government or anyone licensing it on behalf of the U.S. Government, then the following notice is applicable:
U.S. GOVERNMENT END USERS. Oracle programs, including any operating system, integrated software, any programs installed on the hardware, and/or documentation, delivered to U.S. Government end users are "commercial computer software" pursuant to the applicable Federal Acquisition Regulation and agency-specific supplemental regulations. As such, use, duplication, disclosure, modification, and adaptation of the programs, including any operating system, integrated software, any programs installed on the hardware, and/or documentation, shall be subject to license terms and license restrictions applicable to the programs. No other rights are granted to the U.S. Government.
This software or hardware is developed for general use in a variety of information management applications. It is not developed or intended for use in any inherently dangerous applications, including applications that may create a risk of personal injury. If you use this software or hardware in dangerous applications, then you shall be responsible to take all appropriate fail-safe, backup, redundancy, and other measures to ensure its safe use. Oracle Corporation and its affiliates disclaim any liability for any damages caused by use of this software or hardware in dangerous applications.
Oracle and Java are registered trademarks of Oracle and/or its affiliates. Other names may be trademarks of their respective owners.
Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. AMD, Opteron, the AMD logo, and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices. UNIX is a registered trademark of The Open Group.
This software or hardware and documentation may provide access to or information about content, products, and services from third parties. Oracle Corporation and its affiliates are not responsible for and expressly disclaim all warranties of any kind with respect to third-party content, products, and services unless otherwise set forth in an applicable agreement between you and Oracle. Oracle Corporation and its affiliates will not be responsible for any loss, costs, or damages incurred due to your access to or use of third-party content, products, or services, except as set forth in an applicable agreement between you and Oracle.
Documentation Accessibility
For information about Oracle's commitment to accessibility, visit the Oracle Accessibility Program website at http://www.oracle.com/pls/topic/lookup?ctx=acc&id=docacc.
Access to Oracle Support
Oracle customers that have purchased support have access to electronic support through My Oracle Support. For information, visit http://www.oracle.com/pls/topic/lookup?
ctx=acc&id=info or visit http://www.oracle.com/pls/topic/lookup?ctx=acc&id=trs if you are hearing impaired.
Page 4
Référence: E74400-01
Copyright © 2016, Oracle et/ou ses affiliés. Tous droits réservés.
Ce logiciel et la documentation qui l’accompagne sont protégés par les lois sur la propriété intellectuelle. Ils sont concédés sous licence et soumis à des restrictions d’utilisation et de divulgation. Sauf stipulation expresse de votre contrat de licence ou de la loi, vous ne pouvez pas copier, reproduire, traduire, diffuser, modifier, accorder de licence, transmettre, distribuer, exposer, exécuter, publier ou afficher le logiciel, même partiellement, sous quelque forme et par quelque procédé que ce soit. Par ailleurs, il est interdit de procéder à toute ingénierie inverse du logiciel, de le désassembler ou de le décompiler, excepté à des fins d’interopérabilité avec des logiciels tiers ou tel que prescrit par la loi.
Les informations fournies dans ce document sont susceptibles de modification sans préavis. Par ailleurs, Oracle Corporation ne garantit pas qu’elles soient exemptes d’erreurs et vous invite, le cas échéant, à lui en faire part par écrit.
Si ce logiciel, ou la documentation qui l’accompagne, est livré sous licence au Gouvernement des Etats-Unis, ou à quiconque qui aurait souscrit la licence de ce logiciel pour le compte du Gouvernement des Etats-Unis, la notice suivante s’applique:
U.S. GOVERNMENT END USERS. Oracle programs, including any operating system, integrated software, any programs installed on the hardware, and/or documentation, delivered to U.S. Government end users are "commercial computer software" pursuant to the applicable Federal Acquisition Regulation and agency-specific supplemental regulations. As such, use, duplication, disclosure, modification, and adaptation of the programs, including any operating system, integrated software, any programs installed on the hardware, and/or documentation, shall be subject to license terms and license restrictions applicable to the programs. No other rights are granted to the U.S. Government.
Ce logiciel ou matériel a été développé pour un usage général dans le cadre d’applications de gestion des informations. Ce logiciel ou matériel n’est pas conçu ni n’est destiné à être utilisé dans des applications à risque, notamment dans des applications pouvant causer des dommages corporels. Si vous utilisez ce logiciel ou matériel dans le cadre d’ applications dangereuses, il est de votre responsabilité de prendre toutes les mesures de secours, de sauvegarde, de redondance et autres mesures nécessaires à son utilisation dans des conditions optimales de sécurité. Oracle Corporation et ses affiliés déclinent toute responsabilité quant aux dommages causés par l’utilisation de ce logiciel ou matériel pour ce type d’applications.
Oracle et Java sont des marques déposées d’Oracle Corporation et/ou de ses affiliés. Tout autre nom mentionné peut correspondre à des marques appartenant à d’autres propriétaires qu’Oracle.
Intel et Intel Xeon sont des marques ou des marques déposées d’Intel Corporation. Toutes les marques SPARC sont utilisées sous licence et sont des marques ou des marques déposées de SPARC International, Inc. AMD, Opteron, le logo AMD et le logo AMD Opteron sont des marques ou des marques déposées d’Advanced Micro Devices. UNIX est une marque déposée d’The Open Group.
Ce logiciel ou matériel et la documentation qui l’accompagne peuvent fournir des informations ou des liens donnant accès à des contenus, des produits et des services émanant de tiers. Oracle Corporation et ses affiliés déclinent toute responsabilité ou garantie expresse quant aux contenus, produits ou services émanant de tiers, sauf mention contraire stipulée dans un contrat entre vous et Oracle. En aucun cas, Oracle Corporation et ses affiliés ne sauraient être tenus pour responsables des pertes subies, des coûts occasionnés ou des dommages causés par l’accès à des contenus, produits ou services tiers, ou à leur utilisation, sauf mention contraire stipulée dans un contrat entre vous et Oracle.
Accessibilité de la documentation
Pour plus d’informations sur l’engagement d’Oracle pour l’accessibilité à la documentation, visitez le site Web Oracle Accessibility Program, à l’adresse http://www.oracle.com/
pls/topic/lookup?ctx=acc&id=docacc.
Accès aux services de support Oracle
Les clients Oracle qui ont souscrit un contrat de support ont accès au support électronique via My Oracle Support. Pour plus d’informations, visitez le site http://www.oracle.com/
pls/topic/lookup?ctx=acc&id=info ou le site http://www.oracle.com/pls/topic/lookup?ctx=acc&id=trs si vous êtes malentendant.
Page 5

Contents

Using This Documentation .................................................................................  9
Product Documentation Library .........................................................................  9
Feedback .......................................................................................................  9
Understanding the Switch ................................................................................. 11
Installation Task Overview ..............................................................................  11
Switch Overview ...........................................................................................  13
Front Panel Components ................................................................................. 14
Rear Panel Components ..................................................................................  15
Confirming Specifications .................................................................................  17
Physical Specifications ...................................................................................  17
Electrical Specifications ..................................................................................  18
Environmental Specifications ...........................................................................  18
Airflow Precautions .......................................................................................  19
Rack Compatibility ........................................................................................  20
Rack Precautions ...........................................................................................  20
Preparing for Installation ..................................................................................  23
Shipping Kit .................................................................................................  24
▼ Record the MAC IDs ................................................................................ 25
▼ Assign IP Addresses to the SP and SCP Through DHCP .................................  26
Handling Precautions .....................................................................................  26
ESD Precautions ...........................................................................................  27
Installation Tools ...........................................................................................  27
Installing the Switch .........................................................................................  29
▼ Stabilize the Rack ....................................................................................  29
▼ Mark the Rack .........................................................................................  30
▼ Install the Rackmount Hardware .................................................................  32
5
Page 6
Contents
▼ Install the Cable Management Comb ...........................................................  37
▼ Route the Power Cords and Management Cables ............................................  38
▼ Install the Switch .....................................................................................  39
▼ Install an I/O Module ...............................................................................  42
▼ Remove a Filler Panel ...............................................................................  47
Connecting Cables ............................................................................................  51
Chassis Cable Requirements ............................................................................  51
I/O Module Cable Requirements ......................................................................  52
Standard MT and PrizmMT Cables ..................................................................  53
Standard MT and PrizmMT Cable Precautions ...................................................  55
General Cable Precautions ..............................................................................  56
▼ (Optional) Assemble the QSFP Cables .........................................................  58
▼ (Optional) Assemble the SFP+ Cables .........................................................  60
▼ Route the Cables ...................................................................................... 62
▼ Connect the RJ-45 Ethernet Cables .............................................................  63
▼ Connect the PrizmMT Cables .....................................................................  66
▼ Connect the QSFP Cables ..........................................................................  69
▼ Connect the LC Cables .............................................................................  71
▼ Secure Cables to the Cable Management Comb .............................................  73
Powering On the Switch ...................................................................................  75
▼ Connect the SER MGT Cable ....................................................................  75
▼ Connect a Serial Management Device to the SER MGT Port ............................  77
▼ Connect Power Cords ...............................................................................  77
▼ Power On the Switch ................................................................................  81
▼ Log In to the SP (SER MGT) ....................................................................  82
▼ Assign a Static IP Address to the SP ...........................................................  83
▼ Assign a Static IP Address to the SCP .........................................................  85
▼ Log In to the SP (Network Management) .....................................................  86
Verifying Functionality ......................................................................................  89
▼ Verify LED Status ....................................................................................  89
Chassis Status LEDs ......................................................................................  90
1GBase-T Cable Status LEDs .......................................................................... 91
Power Supply Status LEDs .............................................................................  92
Fan Module Status LED .................................................................................  93
I/O Module Status LEDs ................................................................................  93
I/O Module Port LEDs ...................................................................................  94
6 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 7
Contents
▼ Verify That the Switch Is Operational ..........................................................  94
▼ Verify Connectivity ..................................................................................  96
▼ Run the Oracle Fabric OS Configuration Wizard ..........................................  102
Oracle Fabric OS Configuration Wizard Parameters ...........................................  104
▼ Log In to the Oracle Fabric OS Interface ....................................................  105
▼ Log In to the Oracle Fabric Manager Interface .............................................  106
Glossary ..........................................................................................................  109
Index ................................................................................................................  115
7
Page 8
8 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 9

Using This Documentation

Overview – Describes how to prepare for and install the Oracle Fabric Interconnect F2-12.
Audience – Installers, technicians, system administrators, and authorized service providers.
Required knowledge – Advanced experience installing network hardware.
This document uses the terms virtualization switch and switch to refer to the Oracle Fabric Interconnect F2-12.

Product Documentation Library

Documentation and resources for this product and related products are available at http://www.
oracle.com/goto/f2-12/docs.

Feedback

Provide feedback about this documentation at http://www.oracle.com/goto/docfeedback.
Using This Documentation 9
Page 10
10 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 11

Understanding the Switch

These topics describe the switch and the installation process.
“Installation Task Overview” on page 11
“Switch Overview” on page 13
“Front Panel Components” on page 14
“Rear Panel Components” on page 15

Related Information

“Confirming Specifications” on page 17
“Preparing for Installation” on page 23
“Installing the Switch” on page 29
“Connecting Cables” on page 51
“Powering On the Switch” on page 75
“Verifying Functionality” on page 89

Installation Task Overview

Perform these steps in the order presented to install the switch.
Step Description Links
1. Familiarize yourself with the switch. “Switch Overview” on page 13
“Front Panel Components” on page 14
“Rear Panel Components” on page 15
2. Understand supplied power, environmental, and airflow characteristics and rack precautions.
3. Verify shipped components and accessories. “Shipping Kit” on page 24
“Physical Specifications” on page 17
“Electrical Specifications” on page 18
“Environmental Specifications” on page 18
“Airflow Precautions” on page 19
“Rack Compatibility” on page 20
“Rack Precautions” on page 20
Understanding the Switch 11
Page 12
Installation Task Overview
Step Description Links
4. Record the MAC IDs. “Record the MAC IDs” on page 25
5. If DHCP is to assign specific IP addresses to the SP and SCP, configure the DHCP server.
“Assign IP Addresses to the SP and SCP Through
DHCP” on page 26
6. Heed handling and ESD precautions. “Handling Precautions” on page 26
“ESD Precautions” on page 27
7. Ready the rack for the switch. “Stabilize the Rack” on page 29
“Mark the Rack” on page 30
“Install the Rackmount Hardware” on page 32
“Install the Cable Management Comb” on page 37
“Route the Power Cords and Management Cables” on page 38
8. Install the switch and I/O modules (if necessary). “Installation Tools” on page 27
“Install the Switch” on page 39
“Remove a Filler Panel” on page 47
“Install an I/O Module” on page 42
9. Understand cable requirements and precautions. “Chassis Cable Requirements” on page 51
“I/O Module Cable Requirements” on page 52
“Standard MT and PrizmMT Cables” on page 53
“General Cable Precautions” on page 56
10. Connect data cables. “(Optional) Assemble the QSFP Cables” on page 58
“(Optional) Assemble the SFP+ Cables” on page 60
“Route the Cables” on page 62
“Connect the RJ-45 Ethernet Cables” on page 63
“Connect the PrizmMT Cables” on page 66
“Connect the QSFP Cables” on page 69
“Connect the LC Cables” on page 71
“Secure Cables to the Cable Management Comb” on page 73
11. If you are not using DHCP-assigned IP addresses, connect the serial management device.
“Connect the SER MGT Cable” on page 75
“Connect a Serial Management Device to the SER MGT
Port” on page 77
12. Apply power to the switch. “Connect Power Cords” on page 77
“Power On the Switch” on page 81
13. If you are not using DHCP-assigned IP addresses, log in to the SP through the SER MGT port.
“Log In to the SP (SER MGT)” on page 82
“Assign a Static IP Address to the SP” on page 83
“Assign a Static IP Address to the SCP” on page 85
14. Log in to the SP through the network management
“Log In to the SP (Network Management)” on page 86
interface.
15. Verify switch functionality. “Verify LED Status” on page 89
“Verify That the Switch Is Operational” on page 94
“Verify Connectivity” on page 96
16. Administer the switch. “Run the Oracle Fabric OS Configuration Wizard” on page 102
“Oracle Fabric OS Configuration Wizard
Parameters” on page 104
“Log In to the Oracle Fabric OS Interface” on page 105
“Log In to the Oracle Fabric Manager Interface” on page 106
12 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 13

Related Information

“Switch Overview” on page 13
“Front Panel Components” on page 14
“Rear Panel Components” on page 15

Switch Overview

The switch is a complete access switching and I/O platform designed to consolidate and virtualize the switching infrastructure for server and storage systems deployed in high­performance enterprise clouds.
Switch Overview
The virtualization switch can be configured many ways through I/O modules appropriate for your data center. Through I/O modules, the switch can support up to 48 4x IB ports, 24 16Gb FC ports, 48 10GBASE-T ports, 48 40G Ethernet ports, or a mixture of these ports to provide network and gateway capabilities.
Additionally, the switch has a dedicated port block, which also supports limited customization. Through the port block, the switch supports 4 12x IB ports, 4 1GBASE-T ports, and 2 4x IB/40GbE combination ports provide both network and gateway capabilities.
If you configure the 2 4x IB/40GbE ports for IB, then the switch can support a maximum of 50 4x IB ports.
Understanding the Switch 13
Page 14

Front Panel Components

For more information, see “Rear Panel Components” on page 15.
Separate, dedicated, and optimized on-board SP, ABD, and SCP manage chassis functionality, Ethernet traffic, and IB fabric respectively, through user-friendly CLIs and web interfaces.
The virtualization switch ships preconfigured for network management through DHCP. However, the procedures in this document are serial management focused, with instructions to configure static IP addresses if desired.

Related Information

If you configure the 2 4x IB/40GbE ports for GbE, then the switch can support a maximum of 50 40GbE ports.
“Installation Task Overview” on page 11
“Front Panel Components” on page 14
“Rear Panel Components” on page 15
Front Panel Components
The front panel is the fan and power supply end of the switch. This end of the switch is installed to the cold aisle.
No. Description
1 RFID tag
2 Fan modules 0 to 3, starting from the left most fan.
3 Chassis status LEDs
14 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 15
No. Description
4 Power supplies 0 and 1, starting from the left most power supply.

Related Information

“Installation Task Overview” on page 11
“Switch Overview” on page 13
“Rear Panel Components” on page 15

Rear Panel Components

The rear panel is the data cable connection end of the switch. This end of the switch is installed to the hot aisle.
The switch can be populated with any mixture of Oracle F2 I/O modules as needed for your deployment. The illustration shows an example of one hardware configuration for the switch.
Rear Panel Components
No. Description
1 SER MGT connector
2 PrizmMT connectors:
Ports 1 to 4 – 12x IB, which can be used for high-speed inter-switch links connecting leaf switches, virtualization switches, and spine switches together.
Ports 5 and 6 – Either 4x IB or 40 GbE
3 1GBASE-T RJ-45 connectors – Any one of these connectors can be used for network
management.
Understanding the Switch 15
Page 16
Rear Panel Components
No. Description
4 I/O module slots 0 to 11 with slot 0 as the left most slot.
5 Power receptacles for PS1 (AC1 inlet)
6 Power receptacle for PS0 (AC0 inlet)
7 Oracle F2 10 Gb and 40 Gb Ethernet module
8 Filler Panel
9 Oracle F2 Dual Port 16Gb Fibre Channel module
10 Oracle F2 Long Range InfiniBand module
11 Oracle F2 Quad Port 10GBASE-T module

Related Information

“Installation Task Overview” on page 11
“Switch Overview” on page 13
“Front Panel Components” on page 14
16 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 17

Confirming Specifications

These topics describe the specifications of the switch and related precautions for installation.
“Physical Specifications” on page 17
“Electrical Specifications” on page 18
“Environmental Specifications” on page 18
“Airflow Precautions” on page 19
“Rack Compatibility” on page 20
“Rack Precautions” on page 20

Related Information

“Understanding the Switch” on page 11
“Preparing for Installation” on page 23
“Installing the Switch” on page 29
“Connecting Cables” on page 51
“Powering On the Switch” on page 75
“Verifying Functionality” on page 89

Physical Specifications

Dimension Metric U.S.
RU 2 2
Width 448.0 mm 17.64 in.
Depth 804 mm 31.65 in.
Height 87 mm 3.43 in.
Weight (base chassis) 40.1 kg 88.2 lbs
Weight (fully configured) 55.2 kg 121.4 lbs
Confirming Specifications 17
Page 18

Electrical Specifications

Related Information

“Electrical Specifications” on page 18
“Environmental Specifications” on page 18
“Airflow Precautions” on page 19
“Rack Compatibility” on page 20
“Rack Precautions” on page 20
Electrical Specifications
Parameter AC Requirement
Voltage 200 VAC to 277 VAC single phase, 50 to 60 Hz
Current (per input) 16A maximum per input
Current (total) 13A maximum total for all inputs at 208 VAC
Power 2700W (Total input power is approximately equally divided among the
operating power supplies.)

Related Information

“Physical Specifications” on page 17
“Environmental Specifications” on page 18
“Airflow Precautions” on page 19
“Rack Compatibility” on page 20
“Rack Precautions” on page 20

Environmental Specifications

Parameter Metric Operating U.S. Operating
Temperature 5˚C to 35˚C 41˚F to 95˚F
Humidity 5% to 85% noncondensing, 27˚C maximum wet
Elevation (Oracle requirement) Maximum 3000 meters at 40˚C Maximum 9840 feet at 104˚F
bulb

Related Information

“Physical Specifications” on page 17
5% to 85% noncondensing, 80˚F maximum wet bulb
18 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 19
“Electrical Specifications” on page 18
“Airflow Precautions” on page 19
“Rack Compatibility” on page 20
“Rack Precautions” on page 20

Airflow Precautions

Caution - Proper airflow is essential for keeping the switch's internal temperatures within a safe
operating range.
Air flows from the front (fan end) of the switch to the rear (connector end) of the switch.
Airflow Precautions
Follow these guidelines to ensure unrestricted airflow in the switch:
Install the switch so that the front faces the cool aisle and the rear faces the warm aisle.
Do not direct warm air into the switch.
Prevent recirculation of air within a rack or cabinet.
Ensure that either a module or a filler panel is in place while the switch is operating.
Route cables so that they do not interfere with airflow.

Related Information

“Physical Specifications” on page 17
Confirming Specifications 19
Page 20

Rack Compatibility

“Electrical Specifications” on page 18
“Environmental Specifications” on page 18
“Rack Compatibility” on page 20
“Rack Precautions” on page 20
Rack Compatibility
This switch and rackmounting hardware is designed for installation into an Oracle Sun Rack II or compatible rack or cabinet.

Related Information

“Physical Specifications” on page 17
“Electrical Specifications” on page 18
“Environmental Specifications” on page 18
“Airflow Precautions” on page 19
“Rack Precautions” on page 20

Rack Precautions

Caution - Equipment Loading. Always load equipment into a rack from the bottom to the
top so that the rack does not become top heavy and tip over. Deploy your rack's anti-tilt legs to prevent the rack from tipping during equipment installation.
Caution - Elevated Operating Ambient Temperature. If the switch is installed in a closed
or multi-unit rack assembly, the operating ambient temperature of the rack environment might be greater than the room ambient temperature. Therefore, install the equipment only in an environment compatible with the ambient temperature specified for the switch.
Caution - Reduced Air Flow. Install the equipment in a rack so that the amount of air flow is
adequate for the safe operation of the equipment.
Caution - Mechanical Loading. Mount the equipment in the rack so that the weight is
distributed evenly. A hazardous condition can exist with uneven mechanical loading.
20 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 21
Rack Precautions
Caution - Circuit Overloading. Do not overload the power supply circuits. Before connecting
the switch to the supply circuit, review the equipment nameplate power ratings and consider the effect that circuit overloading might have on overcurrent protection and supply wiring.
Caution - Reliable Grounding. Maintain reliable grounding of rackmounted equipment. Give
particular attention to supply connections other than direct connections to the branch circuit (for example, use of power strips).

Related Information

“Physical Specifications” on page 17
“Electrical Specifications” on page 18
“Environmental Specifications” on page 18
“Airflow Precautions” on page 19
“Rack Compatibility” on page 20
Confirming Specifications 21
Page 22
22 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 23

Preparing for Installation

These topics provide information to prepare for the switch installation process.
“Shipping Kit” on page 24
“Handling Precautions” on page 26
“ESD Precautions” on page 27
“Installation Tools” on page 27

Related Information

“Understanding the Switch” on page 11
“Confirming Specifications” on page 17
“Installing the Switch” on page 29
“Connecting Cables” on page 51
“Powering On the Switch” on page 75
“Verifying Functionality” on page 89
Preparing for Installation 23
Page 24

Shipping Kit

Shipping Kit
No. Description
1 Switch
2 Left and right shelf rails
3 Documentation
4 Power cords
5 Cable management comb
6 Fasteners
7 Mushroom screw kit (for use with shelf rails)

Related Information

“Handling Precautions” on page 26
24 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 25
“ESD Precautions” on page 27
“Installation Tools” on page 27

Record the MAC IDs

1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Remove the Customer Information sheet from the outside of the shipping carton.
3.
On the Customer Information sheet, find the switch serial number.
4.
Record the serial number to a document intended for this purpose.
5.
In the Network Interfaces table of the sheet, find the primary MAC ID.
This is the MAC ID of the SP within the switch.
Record the MAC IDs
6.
Record the SP MAC ID to the document.
7.
In the Network Interfaces table of the sheet, find the secondary MAC ID.
This is the MAC ID of the SCP within the switch.
8.
Record the SCP MAC ID to the document.
9.
Secure the Customer Information sheet in a safe place.
10.
Consider your next steps.
If you will assign IP addresses to the SP and SCP through DHCP, configure your DHCP server now.
See “Assign IP Addresses to the SP and SCP Through DHCP” on page 26.
If you will assign static IP addresses to the SP and SCP through the SER
MGT port, go to “Handling Precautions” on page 26.
Related Information
“Shipping Kit” on page 24
“Assign IP Addresses to the SP and SCP Through DHCP” on page 26
“Handling Precautions” on page 26
Preparing for Installation 25
Page 26

Assign IP Addresses to the SP and SCP Through DHCP

“ESD Precautions” on page 27
“Installation Tools” on page 27
Assign IP Addresses to the SP and SCP Through DHCP
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Log in to the DHCP server and configure it to assign a predetermined IP address and host name for the SP MAC ID you recorded.
Record this IP address and host name for future reference.
3.
Configure the DHCP server to assign a predetermined IP address and host name for the SCP MAC ID you recorded.
Record this IP address and host name for future reference.
When the switch is connected to the management network and powered on, the SP and SCP will receive the predetermined IP addresses.
4.
Continue the installation.
See “Handling Precautions” on page 26.
Related Information
“Shipping Kit” on page 24
“Record the MAC IDs” on page 25
“Handling Precautions” on page 26
“ESD Precautions” on page 27
“Installation Tools” on page 27

Handling Precautions

Caution - Deploy the anti-tilt legs on the equipment rack before beginning an installation.
Caution - A lift is required to lift and mount this switch into a rack when using the tasks in this
document.
26 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 27
Caution - When performing a two-person task, always communicate your intentions clearly
before, during, and after each step to minimize confusion.

Related Information

“Shipping Kit” on page 24
“ESD Precautions” on page 27
“Installation Tools” on page 27

ESD Precautions

When installing the switch chassis, follow antistatic precautions:
Use an antistatic mat as a work surface.
Wear an antistatic wrist strap that is attached to either the mat or a metal portion of the switch chassis.
ESD Precautions

Related Information

“Shipping Kit” on page 24
“Handling Precautions” on page 26
“Installation Tools” on page 27

Installation Tools

These tools are necessary or beneficial for installing the switch:
Antistatic wrist strap
Antistatic mat
No. 2 Phillips screwdriver
Cage nut installation tool or flat-blade screwdriver
Serial terminal device and necessary cabling
Masking tape
Paper clip
PrizmMT ferrule cleaner (third-party part) USConec part number 16899
Flashlight
Preparing for Installation 27
Page 28
Installation Tools
Gloves

Related Information

“Shipping Kit” on page 24
“Handling Precautions” on page 26
“ESD Precautions” on page 27
28 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 29

Installing the Switch

These topics describe how to install the switch.
Description Links
Ready the rack for the switch. “Stabilize the Rack” on page 29
“Mark the Rack” on page 30
“Install the Rackmount Hardware” on page 32
“Install the Cable Management Comb” on page 37
“Route the Power Cords and Management
Cables” on page 38
Install the switch into the rack. “Install the Switch” on page 39
If necessary, install I/O modules into the switch.

Related Information

“Understanding the Switch” on page 11
“Confirming Specifications” on page 17
“Preparing for Installation” on page 23
“Connecting Cables” on page 51
“Powering On the Switch” on page 75
“Verifying Functionality” on page 89
“Remove a Filler Panel” on page 47
“Install an I/O Module” on page 42

Stabilize the Rack

Caution - To reduce the risk of personal injury, stabilize the rack and extend all anti-tilt devices
before installing the switch.
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
Installing the Switch 29
Page 30

Mark the Rack

2.
Open and remove the front and rear doors from the rack.
3.
If there are leveling feet beneath the rack to prevent it from rolling, extend these leveling feet fully downward to the floor.
4.
Fully extend the rack's anti-tilt legs or anti-tilt bar, which are located at the bottom front of the rack.
5.
Mark the rack to where the switch will install.
See “Mark the Rack” on page 30.
Related Information
“Mark the Rack” on page 30
“Install the Rackmount Hardware” on page 32
“Install the Cable Management Comb” on page 37
“Route the Power Cords and Management Cables” on page 38
“Install the Switch” on page 39
“Install an I/O Module” on page 42
“Remove a Filler Panel” on page 47
Mark the Rack
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Determine where you are installing the switch.
3.
Mark this location on each rack post with masking tape.
30 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 31
For example, rack unit 9.
Mark the Rack
Counting the number of rack units from the bottom of the rack to the mounting location assists you when marking the other rack posts.
4.
Install the rackmount hardware.
See “Install the Rackmount Hardware” on page 32.
Related Information
“Stabilize the Rack” on page 29
“Install the Rackmount Hardware” on page 32
“Install the Cable Management Comb” on page 37
“Route the Power Cords and Management Cables” on page 38
Installing the Switch 31
Page 32

Install the Rackmount Hardware

“Install the Switch” on page 39
“Install an I/O Module” on page 42
“Remove a Filler Panel” on page 47
Install the Rackmount Hardware
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Identify the left and right shelf rails.
The words LEFT and RIGHT on the shelf rails indicate the front ends of the shelf rails.
32 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 33
Install the Rackmount Hardware
3.
Insert the mushroom screw into the last screw hole on the interior of the shelf rail.
Installing the Switch 33
Page 34
Install the Rackmount Hardware
4.
Lift the left shelf rail, and from the front of the rack, position the rear of the shelf rail into the rear rack post.
5.
Press the shelf rail into the rear rack post while pressing and releasing the release tab.
The shelf rail secures to the rear rack post.
34 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 35
Install the Rackmount Hardware
6.
Extend the shelf rail toward the front of the rack, and position the front of the shelf rail into the front rack post.
7.
Press the shelf rail into the front rack post while pressing and releasing the release tab.
The shelf rail secures to the front rack post.
8.
Repeat Step 4 through Step 7 for the right shelf rail.
9.
Install a 10-32 cage nut into each rear rack post, in the upper square hole of the rack unit immediately above where the shelf rail is installed.
a.
Orient the cage nut to the upper square hole of the rack unit, with the flanges to the right and left.
Installing the Switch 35
Page 36
Install the Rackmount Hardware
b.
Insert the outer flange into the square hole.
c.
Using the cage nut installation tool or flat-blade screwdriver as a guide, catch the inner flange and pry it into the square hole.
d.
Pull the cage nut installation tool or flat blade screwdriver from the flange.
e.
Repeat to install a 10-32 cage nut into the other rear rack post.
10.
Install the cable management comb.
See “Install the Cable Management Comb” on page 37.
Related Information
“Stabilize the Rack” on page 29
“Mark the Rack” on page 30
“Install the Cable Management Comb” on page 37
“Route the Power Cords and Management Cables” on page 38
“Install the Switch” on page 39
“Install an I/O Module” on page 42
“Remove a Filler Panel” on page 47
36 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 37

Install the Cable Management Comb

1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Orient the upper mounting holes of the cable management comb to where you just installed the 10-32 cage nuts.
Install the Cable Management Comb
3.
Using a No. 2 Philips screwdriver, secure the upper mounting holes of the cable management comb to the 10-32 cage nuts with two 10-32 screws.
4.
Secure the lower mounting holes of the cable management comb to the hole in the end center of the shelf rails with two 10-32 screws.
5.
Route the power cords and management cables.
See “Route the Power Cords and Management Cables” on page 38.
Installing the Switch 37
Page 38

Route the Power Cords and Management Cables

Related Information
“Stabilize the Rack” on page 29
“Mark the Rack” on page 30
“Install the Rackmount Hardware” on page 32
“Route the Power Cords and Management Cables” on page 38
“Install the Switch” on page 39
“Install an I/O Module” on page 42
“Remove a Filler Panel” on page 47
Route the Power Cords and Management Cables
The facility power receptacles for the power cords should be located such that the power cords are routed out of the way.
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Route the female end of the power cords up from the power distribution panel or receptacles at the rear of the rack.
3.
Route the network management cable and serial management cable (if a full-time serial management cable will be used) from their respective hubs, concentrators, or switches, to the rack.
4.
Route the cords and management cables to the left rear side where you are installing the switch.
5.
Add at least 8 inches of slack to the cable lengths to enable connection and disconnection with the switch power receptacles, the SER MGT connector, the PrizmMT connectors, and the RJ-45 connectors.
6.
Secure the cables to the rack mounting location with this additional slack.
Use hook and loop fastener straps to bundle and secure the cables.
7.
Install the switch.
See “Install the Switch” on page 39.
Related Information
“Stabilize the Rack” on page 29
“Mark the Rack” on page 30
“Install the Rackmount Hardware” on page 32
38 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 39
“Install the Cable Management Comb” on page 37
“Install the Switch” on page 39
“Install an I/O Module” on page 42
“Remove a Filler Panel” on page 47

Install the Switch

Caution - The weight of the switch is such that a lift or two people are used to raise the switch
to the shelf rails.
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Locate the bracket on each side of the switch.
This bracket will used to correctly seat the switch in the rack.
3.
Carefully lift the switch and begin sliding it into the rack, from the front of the rack rearward.
Install the Switch
Installing the Switch 39
Page 40
Install the Switch
4.
While sliding the switch into the rack, on each side of the switch, make sure each mushroom screw slips into the slot in its bracket.
5.
If the screws are not seated in each bracket's slot, slide the switch out far enough to realign the brackets and screws, then slide the switch in again.
The switch is correctly installed when you have slid it completely into the rack, and each screw is seated in its bracket.
40 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 41
Install the Switch
6.
When the chassis is correctly installed, use a No. 2 Phillips screwdriver to secure the switch chassis to the front rack posts with the captive screws at each side.
7.
Consider your next task.
If you are installing I/O modules, do that now.
See “Install an I/O Module” on page 42.
If you are not installing additional components, go to Step 8.
8.
Consider your next task.
See “(Optional) Assemble the QSFP Cables” on page 58 or “(Optional) Assemble the
SFP+ Cables” on page 60.
See “Route the Cables” on page 62.
Related Information
“Stabilize the Rack” on page 29
“Mark the Rack” on page 30
“Install the Rackmount Hardware” on page 32
“Install the Cable Management Comb” on page 37
Installing the Switch 41
Page 42

Install an I/O Module

“Route the Power Cords and Management Cables” on page 38
“Install an I/O Module” on page 42
“Remove a Filler Panel” on page 47
Install an I/O Module
This procedure depicts installing the Oracle F2 10 Gb and 40 Gb Ethernet module, however the procedure is the same for all I/O modules. I/O modules can be installed in any module slot in the chassis.
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
If the rack rear door is installed, open it.
3.
Grasp the two green loops of the cable management comb, pull them out to release the comb, then swing the comb 90 ° downward.
4.
Remove the I/O module from its antistatic packaging and set it aside on an antistatic mat.
42 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 43
Install an I/O Module
5.
Remove the filler panel from the slot where you are installing the I/O module.
See “Remove a Filler Panel” on page 47.
6.
On the I/O module, squeeze the upper and lower halves of the release lever together, and swing the release lever to the fully open position.
7.
Align the I/O module to the slot where you are installing it.
Installing the Switch 43
Page 44
Install an I/O Module
The LEDs and data cable receptacles face you, and the release lever is to the lower right.
44 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 45
Install an I/O Module
8.
Slide the I/O module into the chassis until the release lever begins to rise, then close the release lever to secure the I/O module in the slot.
9.
Repeat Step 4 to Step 8 for all I/O modules to be installed.
Installing the Switch 45
Page 46
Install an I/O Module
10.
Grasp the two green loops of the cable management comb, pull them out to release the comb, then swing the comb up to the horizontal position.
11.
Cable the switch.
See “(Optional) Assemble the QSFP Cables” on page 58 or “(Optional)
Assemble the SFP+ Cables” on page 60.
See “Route the Cables” on page 62
Related Information
“Stabilize the Rack” on page 29
“Mark the Rack” on page 30
“Install the Rackmount Hardware” on page 32
“Install the Cable Management Comb” on page 37
“Route the Power Cords and Management Cables” on page 38
“Install the Switch” on page 39
“Remove a Filler Panel” on page 47
46 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 47

Remove a Filler Panel

Caution - To maintain thermal stability, never operate the switch with an empty slot. Remove
filler panels only as you replace them with an I/O module in a one-for-one basis.
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
At the location where you are installing the module, remove the filler panel.
Remove a Filler Panel
Installing the Switch 47
Page 48
Remove a Filler Panel
a.
Squeeze the upper and lower halves of the release lever together, and pull the lever in a downward motion.
The filler panel is unseated from the slot connection.
48 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 49
b.
Use the release lever to pull the filler panel from the switch chassis.
Remove a Filler Panel
c.
Use your free hand to take the weight of the filler panel, as it comes free of the chassis.
d.
Set the filler panel aside.
3.
Finish installing an I/O module.
See “Install an I/O Module” on page 42.
Installing the Switch 49
Page 50
Remove a Filler Panel
Related Information
“Stabilize the Rack” on page 29
“Mark the Rack” on page 30
“Install the Rackmount Hardware” on page 32
“Install the Cable Management Comb” on page 37
“Route the Power Cords and Management Cables” on page 38
“Install the Switch” on page 39
“Install an I/O Module” on page 42
50 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 51

Connecting Cables

These topics provide cabling information and describe how to cable the switch.
Description Links
Understand cable requirements. “Chassis Cable Requirements” on page 51
“I/O Module Cable Requirements” on page 52
Identify cable differences. “Standard MT and PrizmMT Cables” on page 53
Heed cable precautions. “General Cable Precautions” on page 56
If necessary, assemble the optical data cables. “(Optional) Assemble the QSFP Cables” on page 58
“(Optional) Assemble the SFP+ Cables” on page 60
Route the data cables. “Route the Cables” on page 62
Connect the data cables. “Connect the RJ-45 Ethernet Cables” on page 63
“Connect the PrizmMT Cables” on page 66
“Connect the QSFP Cables” on page 69
“Connect the LC Cables” on page 71
Secure the cables to the management comb. “Secure Cables to the Cable Management
Comb” on page 73

Related Information

“Understanding the Switch” on page 11
“Confirming Specifications” on page 17
“Preparing for Installation” on page 23
“Installing the Switch” on page 29
“Powering On the Switch” on page 75
“Verifying Functionality” on page 89

Chassis Cable Requirements

Minimal functionality of the switch requires this cabling:
Connecting Cables 51
Page 52

I/O Module Cable Requirements

Management console – The management console is the physical medium that the administrator uses to interact with the SP. There are two ways of making this connection:
Network Management – Network management permits you to use your existing management network to connect an RJ-45 cable to any one of the four connectors on the left rear of the switch. This is the preferred means of connecting to the SP, because it gives you the flexibility to use any host on the management network to interact with the SP and the Oracle ILOM web interface. To improve security, a VLAN ID can be configured for the SP.
Serial management – A serial device, such as a TIP connection, a serial terminal, or a terminal server, is cabled to the SER MGT port on the front of the switch. An advantage of serial management with a dedicated serial terminal is that the connection is more secure than through network management. Because of the nature of the serial signal, a serial management cable cannot be used reliably if it is more than 30 feet (9 meters) long.
Power supplies – Country-specific power cords shipped with the switch supply facility power to the switch from power distribution units inside of the rack.
RJ-45 Ethernet ports – These 4 ports provide switched 1GBASE-T functionality through CAT 6 rated cabling.
PrizmMT ports - Four ports require PrizmMT 12x IB cables, and two ports require PrizmMT 4x cables.

Related Information

“Standard MT and PrizmMT Cables” on page 53
“General Cable Precautions” on page 56
“(Optional) Assemble the QSFP Cables” on page 58
“(Optional) Assemble the SFP+ Cables” on page 60
“Route the Cables” on page 62
“Connect the RJ-45 Ethernet Cables” on page 63
“Connect the PrizmMT Cables” on page 66
“Standard MT and PrizmMT Cable Precautions” on page 55
“Connect the QSFP Cables” on page 69
“Secure Cables to the Cable Management Comb” on page 73
I/O Module Cable Requirements
The I/O modules require cables specific to the I/O module's functionality.
Oracle F2 10 Gb and 40 Gb Ethernet module – MPO and LC duplex type optical fiber cable.
Oracle F2 Dual Port 16Gb Fibre Channel module – LC type optical fiber cables.
52 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 53

Standard MT and PrizmMT Cables

Oracle F2 Long Range InfiniBand module – MPO optical fiber cable.
Oracle F2 Quad Port 10GBASE-T module – Cat 5e or Cat 6 rated UTP RJ-45 cables.
Additional information for cables and connections is available in a connectivity guide for Oracle's EDR switch and Virtualized I/O Systems. Refer to https://community.oracle.com/
docs/DOC-1006347.

Related Information

“Standard MT and PrizmMT Cables” on page 53
“Standard MT and PrizmMT Cable Precautions” on page 55
“General Cable Precautions” on page 56
“(Optional) Assemble the QSFP Cables” on page 58
“(Optional) Assemble the SFP+ Cables” on page 60
“Route the Cables” on page 62
“Connect the RJ-45 Ethernet Cables” on page 63
“Connect the PrizmMT Cables” on page 66
“Connect the QSFP Cables” on page 69
“Secure Cables to the Cable Management Comb” on page 73
Standard MT and PrizmMT Cables
Even though PrizmMT and standard MT optical fiber cables look similar, they are not. PrizmMT cables use clear plastic ferrules that have lenses to focus the laser light across the connection air gap. Standard MT cables rely upon physical contact of fiber tips at each connection. Standard MT and Prizm MT cables have some considerations regarding storage, handling, and connecting to devices. See “Standard MT and PrizmMT Cable
Precautions” on page 55.
Caution - Connecting an PrizmMT cable to a standard MT receptacle, such as on a QSFP
transceiver damages the PrizmMT ferrule and renders the cable unusable.
To help distinguish between PrizmMT and Standard MT cables, PrizmMT cables are identified with certain features. The features are ferrule, housing color, and alignment method and fiber spacing.
Technology Ferrule Housing Color Alignment Method and
4x PrizmMT optical cable PrizmMT (clear with lenses) Magenta Post and hole —Wide
Spacing
Connecting Cables 53
Page 54
Standard MT and PrizmMT Cables
Technology Ferrule Housing Color Alignment Method and
12x PrizmMT optical cable PrizmMT (clear with lenses) Black Post and hole—Wide
4x standard MT optical cable Standard MT (black) Aqua Pins or holes—Narrow
Spacing
Caution - Some supported cables have a PrizmMT connector on one end, and a Standard MT
connector on the other. Pay close attention when connecting these cables. Do not confuse one connector with the other. Damage might occur.
The following illustration shows the difference between the standard MT cable and the PrizmMT cable. The standard MT cable is on the left and the PrizmMT cable is on the right.
No. Description
1 Aqua housing (standard MT)
2 Standard ferrule (standard MT)
3 Alignment pin holes (standard MT)
4 Contact type optical fibers (standard MT)
5 Magenta housing (PrizmMT)
6 PrizmMT ferrule (PrizmMT)
54 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 55
No. Description
7 Alignment post (PrizmMT)
8 Focused optical fiber array (PrizmMT)
9 Alignment hole (PrizmMT)

Related Information

“Chassis Cable Requirements” on page 51
“I/O Module Cable Requirements” on page 52
“Standard MT and PrizmMT Cable Precautions” on page 55
“General Cable Precautions” on page 56
“(Optional) Assemble the QSFP Cables” on page 58
“(Optional) Assemble the SFP+ Cables” on page 60
“Route the Cables” on page 62
“Connect the RJ-45 Ethernet Cables” on page 63
“Connect the PrizmMT Cables” on page 66
“Connect the QSFP Cables” on page 69
“Secure Cables to the Cable Management Comb” on page 73

Standard MT and PrizmMT Cable Precautions

Standard MT and PrizmMT Cable Precautions
Be aware of the following considerations for storing, connecting, and removing standard MT and PrizmMT cables:
Whenever cables are not in use, put a dust cap on each end to prevent dust and debris from accumulating.
Before connecting the cable:
Clean every connection, both sides, every time the connection is to be mated. Even when the dust caps are in place, dust or debris may have been inside the dust cap from a prior use, then transfer onto the ferrule.
Check the keying of the connector and the keying of the port. The raised rectangular feature on the housing gives you a visual indication of how the cable and port will mate.
Check for a white dot on the cable housing to help you determine how the cable should be inserted into the port. For any vertical receptacle, the white dot must be facing down.
When connecting a cable:
Do not attempt to defeat the internal shutters on the ports because you can possibly damage the cable's ferrule.
Ensure the tip of the ferrule does not forcefully contact the edges of the ports or your risk damaging the equipment. Instead, carefully insert the tip of the ferrule into the center of the port.
Connecting Cables 55
Page 56

General Cable Precautions

When removing a cable, the connector can unlatch from the port only by pulling on the colored cable housing. By pulling on the cable and not the housing, you risk pulling the cable out of the housing.
For additional cable handling precautions, see “General Cable Precautions” on page 56.

Related Information

“Chassis Cable Requirements” on page 51
“I/O Module Cable Requirements” on page 52
“Standard MT and PrizmMT Cables” on page 53
“(Optional) Assemble the QSFP Cables” on page 58
“(Optional) Assemble the SFP+ Cables” on page 60
“Route the Cables” on page 62
“Connect the RJ-45 Ethernet Cables” on page 63
“Connect the PrizmMT Cables” on page 66
“Connect the QSFP Cables” on page 69
“Secure Cables to the Cable Management Comb” on page 73
General Cable Precautions
To prevent data cable damage, you must follow these cautions.
Do not uncoil the cable, as a kink might occur. Hold the coil closed as you unroll the cable, pausing to allow the cable to relax as it is unrolled.
Do not pull the cable out of the shipping box, through any opening, or around any corners. Unroll the cable as you lay it down and move it through turns.
Do not step on the cable or connectors. Plan cable paths away from foot traffic or rolling loads.
Do not bend the cables to a radius tighter than 85 mm (3.4 inches). Ensure that cable turns are as wide as possible.
56 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 57
General Cable Precautions
Do not twist the cable to open a kink. If it is not severe, open the kink by unlooping the cable.
Do not straighten the cable to correct a bend that is too tight. Leave the cable bend as is.
Do not drop the cable or connectors from any height. Gently set the cable down, resting the cable connectors on a stable surface.
Do not drag the cable or its connectors over any surface. Carry the entire cable to and from the points of connection.
Do not pack the cable to fit a tight space. Use an alternative cable route.
Do not hang the cable for a length more than 2 meters (7 feet). Minimize the hanging weight with intermediate retention points.
Do not cinch the cable with hard fasteners or cable ties. Use soft hook-and-loop fastener for bundling and securing cables.
Do not force the cable connector into the receptacle by pushing on the cable. Apply connection or disconnection forces at the connector only.

Related Information

“Chassis Cable Requirements” on page 51
“I/O Module Cable Requirements” on page 52
“Standard MT and PrizmMT Cables” on page 53
“Standard MT and PrizmMT Cable Precautions” on page 55
“(Optional) Assemble the QSFP Cables” on page 58
“(Optional) Assemble the SFP+ Cables” on page 60
“Route the Cables” on page 62
“Connect the RJ-45 Ethernet Cables” on page 63
“Connect the PrizmMT Cables” on page 66
“Connect the QSFP Cables” on page 69
“Secure Cables to the Cable Management Comb” on page 73
Connecting Cables 57
Page 58

(Optional) Assemble the QSFP Cables

(Optional) Assemble the QSFP Cables
If the optical QSFP cables are unassembled, you must assemble the cables before attaching them to the switch.
Note - The ends of the optical fiber cable and the receptacles of the transceivers must be clean
and optically clear before assembly. Do not remove the protective caps from the optical fiber cable or the plugs from the transceivers until instructed to do so.
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Remove the QSFP optical transceivers, and fiber optic cables from their packaging.
3.
Sort the components into groupings ready for assembly.
If you are assembling an InfiniBand cable or Ethernet pass-through cable, you need two QSFP optical transceivers and a fiber optic cable.
If you are to assemble an Ethernet splitter cable, you will need one QSFP optical transceiver, four SFP+ optical transceivers, and an optical splitter cable.
4.
Remove the plug from the QSFP optical transceiver.
5.
Remove the cap from the MTP connector of the fiber optic cable.
6.
Holding the shaft of the MTP connector, insert the MTP connector into the receptacle of the QSFP optical transceiver.
58 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 59
(Optional) Assemble the QSFP Cables
Note - The MPO connector and QSFP receptacle are keyed for proper fitting. There are
different types of QSFP receptacles. For example, some have a retaining clip, shown, and some have a retaining strap.
7.
Push the connector into the transceiver until it clicks.
8.
Consider your next step.
If you are assembling an InfiniBand cable or Ethernet pass-through cable, repeat Step 4 to Step 7 for the other end of the cable, and then go to Step 10.
If you are assembling an Ethernet splitter cable, go to Step 9.
9.
Repeat from Step 4 for all QSFP optical transceivers and MTP connectors.
10.
Repeat from Step 3 for all data cables to be assembled.
11.
Route the data cables.
See “Route the Cables” on page 62.
Connecting Cables 59
Page 60

(Optional) Assemble the SFP+ Cables

Related Information
“Chassis Cable Requirements” on page 51
“I/O Module Cable Requirements” on page 52
“Standard MT and PrizmMT Cables” on page 53
“Standard MT and PrizmMT Cable Precautions” on page 55
“General Cable Precautions” on page 56
“(Optional) Assemble the SFP+ Cables” on page 60
“Route the Cables” on page 62
“Connect the RJ-45 Ethernet Cables” on page 63
“Connect the PrizmMT Cables” on page 66
“Connect the QSFP Cables” on page 69
“Secure Cables to the Cable Management Comb” on page 73
(Optional) Assemble the SFP+ Cables
If the optical SFP+ cables are unassembled, you must assemble the cables before attaching them to the switch.
Note - The ends of the optical fiber cable and the receptacles of the transceivers must be clean
and optically clear before assembly. Do not remove the protective caps from the optical fiber cable or the plugs from the transceivers until instructed to do so.
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Remove the SFP+ optical transceivers and fiber optic cables from their packaging.
3.
Sort the components into groupings ready for assembly.
If you are to assemble an Ethernet splitter cable, you will need one QSFP optical transceiver, four SFP+ optical transceivers, and an optical splitter cable.
4.
Remove the plug from an SFP+ optical transceiver.
5.
Remove the caps from an LC connector of the fiber optic cable.
6.
Holding the shafts of the LC connector, insert it into the receptacles of the SFP+ optical transceiver.
60 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 61
(Optional) Assemble the SFP+ Cables
Note - The LC connector and SFP+ receptacles are keyed for proper fitting.
7.
Push the connector into the transceiver until it clicks.
8.
Repeat from Step 4 for all SFP+ optical transceivers and LC connectors.
9.
Repeat from Step 3 for all data cables to be assembled.
10.
Route the data cables.
See “Route the Cables” on page 62.
Related Information
“Chassis Cable Requirements” on page 51
“I/O Module Cable Requirements” on page 52
“Standard MT and PrizmMT Cables” on page 53
“Standard MT and PrizmMT Cable Precautions” on page 55
“General Cable Precautions” on page 56
Connecting Cables 61
Page 62

Route the Cables

“(Optional) Assemble the QSFP Cables” on page 58
“Route the Cables” on page 62
“Connect the RJ-45 Ethernet Cables” on page 63
“Connect the PrizmMT Cables” on page 66
“Connect the QSFP Cables” on page 69
“Secure Cables to the Cable Management Comb” on page 73
Route the Cables
When cabling a topology, start at the nodes of the fabric or hosts of the network, and work toward the switch.
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Prepare the cables to connect the nodes or hosts to the switch.
See “(Optional) Assemble the QSFP Cables” on page 58 or “(Optional) Assemble the SFP+
Cables” on page 60.
3.
Prepare and verify that the nodes or hosts are operational, properly configured, and ready to accept fabric or network cabling.
4.
For each node or host, begin data cabling.
a.
Attach the cable to the appropriate connector of the node or host.
b.
Route and bundle the data cable through the topology following the cautions provided in this document.
See “General Cable Precautions” on page 56.
c.
Bring the cables to the location in the rack where the switch is installed.
d.
Repeat Step 4a through Step 4c for each node or host.
5.
Connect the cables to the switch.
See “Connect the RJ-45 Ethernet Cables” on page 63.
Related Information
“Chassis Cable Requirements” on page 51
62 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 63
“I/O Module Cable Requirements” on page 52
“Standard MT and PrizmMT Cables” on page 53
“Standard MT and PrizmMT Cable Precautions” on page 55
“General Cable Precautions” on page 56
“(Optional) Assemble the QSFP Cables” on page 58
“(Optional) Assemble the SFP+ Cables” on page 60
“Connect the RJ-45 Ethernet Cables” on page 63
“Connect the PrizmMT Cables” on page 66
“Connect the QSFP Cables” on page 69
“Secure Cables to the Cable Management Comb” on page 73

Connect the RJ-45 Ethernet Cables

Use this procedure to connect RJ-45 cables to an Oracle F2 Quad Port 10GBASE-T I/O module as well as to the switch chassis.
Connect the RJ-45 Ethernet Cables
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Orient the RJ-45 connector to where it will connect to the switch.
Connecting Cables 63
Page 64
Connect the RJ-45 Ethernet Cables
For the chassis, the tab on the connector is up.
64 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 65
Connect the RJ-45 Ethernet Cables
For the Oracle F2 Quad Port 10GBASE-T module, the tab on the connector is to the right.
3.
Insert the connector into the receptacle until it clicks, securing it in place.
4.
Lay the cable into a slot on the cable management comb.
5.
Repeat Step 2 and Step 3 for each cable to be connected.
6.
Consider your next task.
Connect the PrizmMT cables if necessary. See “Connect the PrizmMT Cables” on page 66.
Connecting Cables 65
Page 66

Connect the PrizmMT Cables

Connect the QSFP cables if necessary.
See “Connect the QSFP Cables” on page 69.
Connect the LC cables if necessary.
See “Connect the LC Cables” on page 71.
Secure the cables to the cable management comb.
See “Secure Cables to the Cable Management Comb” on page 73.
Related Information
“Chassis Cable Requirements” on page 51
“I/O Module Cable Requirements” on page 52
“Standard MT and PrizmMT Cables” on page 53
“Standard MT and PrizmMT Cable Precautions” on page 55
“General Cable Precautions” on page 56
“(Optional) Assemble the QSFP Cables” on page 58
“(Optional) Assemble the SFP+ Cables” on page 60
“Route the Cables” on page 62
“Connect the PrizmMT Cables” on page 66
“Connect the QSFP Cables” on page 69
“Secure Cables to the Cable Management Comb” on page 73
Connect the PrizmMT Cables
Use this procedure to connect the PrizmMT cables to the chassis gateway ports.
Note - Only PrizmMT receptacles labeled 5 and 6 are for 4x magenta-colored housing
PrizmMT cables. All other PrizmMT receptacles are for 12x black-colored housing PrizmMT cables. The 12x cables (black-colored housing) are used for connecting the virtualization switch to leaf switches, spine switches, and other F2-12 switches through inter-switch links.
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Remove any filler plug (if installed) from the PrizmMT receptacle where you are installing the cable, and visually inspect the receptacle.
The receptacle should be clean and free of dirt or debris.
66 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 67
Connect the PrizmMT Cables
3.
Clean the receptacle:
a.
Remove the adapter from the end of the PrizmMT cleaner.
b.
Insert the cleaner tip into the receptacle.
c.
Pump the cleaner into the receptacle, advancing the cleaning cloth inside.
d.
Remove the cleaner from the receptacle and verify cleanliness.
e.
Replace the adapter onto the end of the PrizmMT cleaner.
4.
Remove the protective cap from the cable connector and visually inspect the connector.
The connector should be clean and free of dirt or debris.
5.
Identify the cable-alignment features on the cable, such as the keying on the cable connector and port, and the white dot on the housing.
See “Standard MT and PrizmMT Cable Precautions” on page 55.
6.
Align the PrizmMT connector to where it will connect.
For the chassis, the receptacle is vertical, so the connector is correctly aligned when the white dot on the housing is facing down.
Connecting Cables 67
Page 68
Connect the PrizmMT Cables
Caution - When aligning the PrizmMT connector and port receptacle, ensure the tip of the
ferrule does not forcefully contact the edges of the ports or you risk damaging the equipment. Instead, carefully insert the tip of the ferrule into the center of the port.
7.
Firmly press the PrizmMT connector into the receptacle until you feel the connector securely latch into the receptacle.
8.
Lay the cable into a slot on the cable management comb.
9.
Repeat Step 2 through Step 8 for each cable to be connected.
10.
If link quality issues occur, and you suspect cleanliness is the cause:
68 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 69
a.
Unplug the cable(s).
b.
For each end of the cable, repeat Step 3b.
c.
Plug in the cable(s).
11.
When cables are connected, consider your next task.
Connect the QSFP cables if necessary.
See “Connect the QSFP Cables” on page 69.
Connect the LC cables if necessary.
See “Connect the LC Cables” on page 71.
12.
Lay the cables into place.
See “Secure Cables to the Cable Management Comb” on page 73.
Related Information

Connect the QSFP Cables

“Chassis Cable Requirements” on page 51
“I/O Module Cable Requirements” on page 52
“Standard MT and PrizmMT Cables” on page 53
“Standard MT and PrizmMT Cable Precautions” on page 55
“General Cable Precautions” on page 56
“(Optional) Assemble the QSFP Cables” on page 58
“(Optional) Assemble the SFP+ Cables” on page 60
“Route the Cables” on page 62
“Connect the RJ-45 Ethernet Cables” on page 63
“Connect the QSFP Cables” on page 69
“Secure Cables to the Cable Management Comb” on page 73
Connect the QSFP Cables
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Remove the protective cap from the connector or transceiver, and visually inspect the cable connector.
Connecting Cables 69
Page 70
Connect the QSFP Cables
The shell should not be bent and should be parallel to the inner boards. If the connector is bent or damaged, use a different cable.
3.
Ensure that the retraction strap is folded back against the cable.
4.
Orient the cable connector to the QSFP receptacle squarely and vertically.
For the Oracle F2 10 Gb and 40 Gb Ethernet module, ensure that the L groove is to the right.
5.
Slowly move the connector in.
As you slide the connector in, the shell should be in the center of the QSFP receptacle.
If the connector stops or binds after about 1/4 in. (5 mm) travel, back out and
repeat from Step 4.
If the connector stops or binds with about 1/8 in. (2 mm) still to go, back out and repeat Step 5.
6.
Connect the cable.
7.
Lay the cable into a slot on the cable management comb.
8.
Continue to push the connector in until you feel it seat.
70 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 71
9.
Repeat Step 6 through Step 7 for each cable to be connected.
10.
Secure the cables to the cable management comb.
See “Secure Cables to the Cable Management Comb” on page 73.
Related Information
“Chassis Cable Requirements” on page 51
“I/O Module Cable Requirements” on page 52
“Standard MT and PrizmMT Cables” on page 53
“Standard MT and PrizmMT Cable Precautions” on page 55
“General Cable Precautions” on page 56
“(Optional) Assemble the QSFP Cables” on page 58
“(Optional) Assemble the SFP+ Cables” on page 60
“Route the Cables” on page 62
“Connect the RJ-45 Ethernet Cables” on page 63
“Connect the PrizmMT Cables” on page 66
“Secure Cables to the Cable Management Comb” on page 73

Connect the LC Cables

Connect the LC Cables
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Remove the protective caps from the LC connector.
3.
If the module does not already have an SFP+ connector installed, complete Step
6 through Step 7, then return to this procedure.
4.
Orient the cable connector to the LC receptacle squarely and vertically.
Ensure that the release tabs are to the right.
Connecting Cables 71
Page 72
Connect the LC Cables
Note - Depending on whether you assembled the LC cable and SFP+ connector, the connector
might be attached to the cable instead of inserted into the module receptacle. Also, ensure the metal clip on the transceiver is in the closed position prior to connecting the cable to the transceiver.
5.
Push the connector in until you feel a click.
6.
Lay the cable into a slot on the cable management comb.
7.
Repeat Step 2 through Step 8 for each cable to be connected.
8.
Secure the cables to the cable management Comb.
See “Secure Cables to the Cable Management Comb” on page 73.
Related Information
“Chassis Cable Requirements” on page 51
“I/O Module Cable Requirements” on page 52
“Standard MT and PrizmMT Cables” on page 53
“Standard MT and PrizmMT Cable Precautions” on page 55
“General Cable Precautions” on page 56
“(Optional) Assemble the QSFP Cables” on page 58
“(Optional) Assemble the SFP+ Cables” on page 60
“Route the Cables” on page 62
“Connect the RJ-45 Ethernet Cables” on page 63
“Connect the PrizmMT Cables” on page 66
72 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 73

Secure Cables to the Cable Management Comb

“Secure Cables to the Cable Management Comb” on page 73
Secure Cables to the Cable Management Comb
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
While connecting the RJ-45, SFP+, QSFP, and PrizmMT cables to the switch, lay the cables into an available slot on the cable management comb.
3.
Route the data cables so that they do not interfere with other cables, or with servicing the switch or other systems.
Use hook and loop fastener straps to bundle and secure the cables.
Note - Do not use cable zip ties to bundle or secure the cables, because the ties damage the
fibers inside the cables.
Connecting Cables 73
Page 74
Secure Cables to the Cable Management Comb
4.
Consider your next task.
If you have DHCP-assigned IP addresses, connect the power cords.
See “Connect Power Cords” on page 77.
Otherwise, connect the SER MGT cable.
See “Connect the SER MGT Cable” on page 75.
Related Information
“Chassis Cable Requirements” on page 51
“I/O Module Cable Requirements” on page 52
“Standard MT and PrizmMT Cables” on page 53
“Standard MT and PrizmMT Cable Precautions” on page 55
“General Cable Precautions” on page 56
“(Optional) Assemble the QSFP Cables” on page 58
“(Optional) Assemble the SFP+ Cables” on page 60
“Route the Cables” on page 62
“Connect the RJ-45 Ethernet Cables” on page 63
“Connect the PrizmMT Cables” on page 66
“Connect the QSFP Cables” on page 69
74 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 75

Powering On the Switch

These topics describe how to power on the switch for the first time.
Description Links
If you are not using DHCP-assigned IP addresses, connect the serial management device.
Connect the power cords. “Connect Power Cords” on page 77
Power on the switch. “Power On the Switch” on page 81
If you are not using DHCP-assigned IP addresses, log in to the SP through the SER MGT port.
Log in to the SP through the network management interface.

Related Information

“Connect the SER MGT Cable” on page 75
“Connect a Serial Management Device to the SER MGT
Port” on page 77
“Log In to the SP (SER MGT)” on page 82
“Assign a Static IP Address to the SP” on page 83
“Assign a Static IP Address to the SCP” on page 85
“Log In to the SP (Network Management)” on page 86
“Understanding the Switch” on page 11
“Confirming Specifications” on page 17
“Preparing for Installation” on page 23
“Installing the Switch” on page 29
“Connecting Cables” on page 51
“Verifying Functionality” on page 89

Connect the SER MGT Cable

1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Orient the RJ-45 connector to the SER MGT receptacle.
Powering On the Switch 75
Page 76
Connect the SER MGT Cable
The tab is down for the receptacle.
3.
Insert the connector into the receptacle until it clicks, securing it in place.
4.
Connect the other end of the SER MGT cable to a serial device.
See “Connect a Serial Management Device to the SER MGT Port” on page 77.
Related Information
“Connect a Serial Management Device to the SER MGT Port” on page 77
“Connect Power Cords” on page 77
“Power On the Switch” on page 81
“Log In to the SP (SER MGT)” on page 82
“Assign a Static IP Address to the SP” on page 83
“Assign a Static IP Address to the SCP” on page 85
“Log In to the SP (Network Management)” on page 86
76 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 77

Connect a Serial Management Device to the SER MGT Port

Connect a Serial Management Device to the SER MGT Port
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Configure the serial management device to these parameters:
9600 baud
8 data bits
No parity
1 stop bit
No handshake
3.
Connect the SER MGT cable from the switch to the serial management device.
4.
If necessary, route the SER MGT cable so that it does not interfere with other cables, with servicing the switch, or with other systems.
5.
Connect the power cords.
See “Connect Power Cords” on page 77.
Related Information
“Connect the SER MGT Cable” on page 75
“Connect Power Cords” on page 77
“Power On the Switch” on page 81
“Log In to the SP (SER MGT)” on page 82
“Assign a Static IP Address to the SP” on page 83
“Assign a Static IP Address to the SCP” on page 85
“Log In to the SP (Network Management)” on page 86

Connect Power Cords

1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Ensure that the circuit breakers for the facility power receptacle or power distribution device are switched off.
Powering On the Switch 77
Page 78
Connect Power Cords
3.
Lower the retaining wire from in front of the power receptacles at the rear of the switch chassis.
4.
Plug both power cords into the receptacles.
78 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 79
Connect Power Cords
In this illustration, AC1 is the left power receptacle, and AC0 is the right power receptacle.
Powering On the Switch 79
Page 80
Connect Power Cords
5.
Raise the retaining wire back up and snap it over the power cords to secure them.
6.
Plug each power cord into the facility power receptacle or power distribution device.
Note - To provide redundancy, connect each power cord to a separate power source. The switch
can operate with only one power source, but there is no redundancy in that case.
Caution - Do not apply power at this time.
80 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 81
7.
Power on the switch.
See “Power On the Switch” on page 81.
Related Information
“Connect the SER MGT Cable” on page 75
“Connect a Serial Management Device to the SER MGT Port” on page 77
“Power On the Switch” on page 81
“Log In to the SP (SER MGT)” on page 82
“Assign a Static IP Address to the SP” on page 83
“Assign a Static IP Address to the SCP” on page 85
“Log In to the SP (Network Management)” on page 86

Power On the Switch

When live power is delivered to the receptacles at the rear of the chassis, standby and main power is made available by the power supplies. The switch immediately comes to full power. Both the SP and SCP begin their boot processes.
Power On the Switch
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Ensure that:
Nodes of the IB fabric and hosts of the Ethernet and Fibre Channel networks are operational and securely cabled to the switch.
Serial management console is operational, configured with correct parameters, and cabled to the switch. See “Connect a Serial Management Device to the SER MGT
Port” on page 77.
Management network is operational and securely cabled to the switch.
Facility power source or power distribution device is properly cabled to the switch, available, and standing by.
All data, management, and power cabling to the switch is secure at the switch.
3.
Energize the circuit breakers so that facility power is delivered to the switch.
These actions occur in order:
All chassis status LEDs illuminate, then go dark.
The power supply LEDs indicate input power, then output power.
The fans spin up.
Full power is applied to all circuits and systems inside the switch.
Powering On the Switch 81
Page 82

Log In to the SP (SER MGT)

Both the SP and SCP are powered on and booting up.
Note - You might see the boot sequence on the serial device.
The SP LED blinks slowly.
When the SP LED stops blinking and stays lit, and the OK LED lights, it is possible to log in to the SP.
4.
Consider your next steps.
If you have DHCP-assigned IP addresses, log in to the SP through the network.
See “Log In to the SP (Network Management)” on page 86.
Otherwise, log in to the SP through the SER MGT port. See “Log In to the SP (SER MGT)” on page 82.
Related Information
“Connect the SER MGT Cable” on page 75
“Connect a Serial Management Device to the SER MGT Port” on page 77
“Connect Power Cords” on page 77
“Log In to the SP (SER MGT)” on page 82
“Assign a Static IP Address to the SP” on page 83
“Assign a Static IP Address to the SCP” on page 85
“Log In to the SP (Network Management)” on page 86
Log In to the SP (SER MGT)
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
On the serial management device, press the Return or Enter key several times to synchronize the connection.
The login prompt is displayed.
hostname login:
where hostname is the host name of the SP. If no host name is assigned, ORACLESP-unknown might be displayed.
82 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 83

Assign a Static IP Address to the SP

3.
Log in to the SP with user name root and password changeme.
hostname login: root Password: changeme
->
The -> prompt is displayed.
Note - You can change the password at a later time. Refer to the Oracle EDR InfiniBand Switch
and Virtualized I/O System Administration Guide, changing the administrator password.
4.
Consider your next task.
If you have a full-time SER MGT connection, go to “Verify LED
Status” on page 89 or “Assign a Static IP Address to the SP” on page 83.
If your SER MGT connection is only temporary, go to “Assign a Static IP
Address to the SP” on page 83.
Related Information
“Connect the SER MGT Cable” on page 75
“Connect a Serial Management Device to the SER MGT Port” on page 77
“Connect Power Cords” on page 77
“Power On the Switch” on page 81
“Assign a Static IP Address to the SP” on page 83
“Assign a Static IP Address to the SCP” on page 85
“Log In to the SP (Network Management)” on page 86
Assign a Static IP Address to the SP
The switch ships with DHCP IP address assignment for the SP.
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Access the Oracle ILOM CLI.
See “Log In to the SP (SER MGT)” on page 82.
3.
Configure the network management parameters.
-> set /SP/network property=value property=value ...
Powering On the Switch 83
Page 84
Assign a Static IP Address to the SP
where:
property is the parameter of the network to configure.
value is the value of the property to configure.
These properties are supported:
pendingipaddressvalue is the IP address of the SP to be configured.
pendingipdiscoveryvalue is the method of IP discovery to be configured, either static or dhcp.
pendingipgatewayvalue is the IP address of the routing gateway to be configured.
pendingipnetmaskvalue is the netmask to be configured.
Note - You can configure one, several, or all properties in one command line.
For example:
-> set /SP/network pendingipdiscovery=static pendingipaddress=123.45.67.89 pendingipgateway=123.45.67.1 pendingipnetmask=255.255.255.0
Set 'pendingipdiscovery' to 'static' Set 'pendingipaddress' to '123.45.67.89' Set 'pendingipgateway' to '123.45.67.1' Set 'pendingipnetmask' to '255.255.255.0'
->
4.
Commit the changes.
-> set /SP/network commitpending=true Set 'commitpending' to 'true'
->
The static IP address has been configured to 123.45.67.89. You can now manage the SP from any one of the four RJ-45 connectors on the left side of the rear panel.
5.
Consider your next steps.
Configure a static IP address for the SCP.
See “Assign a Static IP Address to the SCP” on page 85.
Log in to the SP through the management network.
See “Log In to the SP (Network Management)” on page 86.
Related Information
“Connect the SER MGT Cable” on page 75
“Connect a Serial Management Device to the SER MGT Port” on page 77
84 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 85
“Connect Power Cords” on page 77
“Power On the Switch” on page 81
“Log In to the SP (SER MGT)” on page 82
“Assign a Static IP Address to the SCP” on page 85
“Log In to the SP (Network Management)” on page 86

Assign a Static IP Address to the SCP

The switch ships with DHCP IP address assignment for the SCP.
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Access the Oracle ILOM CLI.
See “Log In to the SP (SER MGT)” on page 82 or “Log In to the SP (Network
Management)” on page 86.
Assign a Static IP Address to the SCP
3.
Start the host console.
-> start /HOST/console
Are you sure you want to start /HOST/console (y/n)? y Serial console started. To stop, type ESC (
4.
Press the Enter key.
hostname login:
5.
Log in as the root user.
hostname login: root Password:changeme Last login: Fri May 25 09:51:36 on ttyS0 [root@hostname ~]#
The default password is changeme.
6.
If this is the first time the switch has been started, or if the switch config has been cleared, through the Oracle Fabric OS Configuration Wizard:
a.
Specifying the SCP address allocation method, either static or dhcp.
b.
(Optional) For a static SCP address, specify the IP address and netmask in dotted decimal notation.
Powering On the Switch 85
Page 86

Log In to the SP (Network Management)

c.
Set the switch's host name.
See “Run the Oracle Fabric OS Configuration Wizard” on page 102.
Note - If the Oracle Fabric OS Configuration Wizard does not start, you can set the SCP IP
address and netmask, and host name through the set system management-interface, set system management-interface -netmask, and set system hostname commands in the
Oracle Fabric OS.
7.
(Optional) If the SER MGT connection is temporary, you can disconnect it now.
8.
Log in to the SP through the management network.
See “Log In to the SP (Network Management)” on page 86.
Related Information
“Connect the SER MGT Cable” on page 75
“Connect a Serial Management Device to the SER MGT Port” on page 77
“Connect Power Cords” on page 77
“Power On the Switch” on page 81
“Log In to the SP (SER MGT)” on page 82
“Assign a Static IP Address to the SP” on page 83
“Log In to the SP (Network Management)” on page 86
Log In to the SP (Network Management)
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Open an SSH session and connect to the SP by specifying the IP address you previously configured.
For example, type:
% ssh -l root IP_address password: password
->
where IP_address is the IP address of the SP. Initially, the password is changeme.
86 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 87
Log In to the SP (Network Management)
Note - You can change the password at a later time. Refer to the Oracle EDR InfiniBand
Switch and Virtualized I/O System Administration Guide, changing the root user password for
instructions.
The Oracle ILOM shell prompt (->) is displayed.
3.
Verify switch functionality.
See “Verify LED Status” on page 89.
Related Information
“Connect the SER MGT Cable” on page 75
“Connect a Serial Management Device to the SER MGT Port” on page 77
“Connect Power Cords” on page 77
“Power On the Switch” on page 81
“Log In to the SP (SER MGT)” on page 82
“Assign a Static IP Address to the SP” on page 83
“Assign a Static IP Address to the SCP” on page 85
Powering On the Switch 87
Page 88
88 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 89

Verifying Functionality

These topics describe how to verify the functionality of the switch and begin use of it.
Description Links
Verify switch functionality. “Verify LED Status” on page 89
“Chassis Status LEDs” on page 90
“1GBase-T Cable Status LEDs” on page 91
“Power Supply Status LEDs” on page 92
“Fan Module Status LED” on page 93
“I/O Module Status LEDs” on page 93
“I/O Module Port LEDs” on page 94
“Verify That the Switch Is Operational” on page 94
“Verify Connectivity” on page 96
Administer the switch. “Log In to the Oracle Fabric OS Interface” on page 105
“Run the Oracle Fabric OS Configuration
Wizard” on page 102
“Oracle Fabric OS Configuration Wizard
Parameters” on page 104
“Log In to the Oracle Fabric Manager Interface” on page 106

Related Information

“Understanding the Switch” on page 11
“Confirming Specifications” on page 17
“Preparing for Installation” on page 23
“Installing the Switch” on page 29
“Connecting Cables” on page 51
“Powering On the Switch” on page 75

Verify LED Status

1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
Verifying Functionality 89
Page 90

Chassis Status LEDs

2.
3.
See “Installation Task Overview” on page 11.
At the switch, observe the state of the various chassis and component LEDs.
Chassis status LEDs.
See “Chassis Status LEDs” on page 90.
Power supply LEDs.
See “Power Supply Status LEDs” on page 92.
Fan module LEDs.
See “Fan Module Status LED” on page 93.
RJ-45 receptacle LEDs.
See “1GBase-T Cable Status LEDs” on page 91.
I/O module LEDs.
See “I/O Module Status LEDs” on page 93.
Verify that the switch is operating.
See “Verify That the Switch Is Operational” on page 94.
Related Information
“Verify That the Switch Is Operational” on page 94
“Verify Connectivity” on page 96
“Log In to the Oracle Fabric Manager Interface” on page 106
“Log In to the Oracle Fabric OS Interface” on page 105
“Run the Oracle Fabric OS Configuration Wizard” on page 102
“Oracle Fabric OS Configuration Wizard Parameters” on page 104
Chassis Status LEDs
Status LEDs for the entire system are located on the front panel of the virtualization switch above the power supplies.
Glyph Name Color State and Meaning
Locate White Indicates these conditions:
On – No function.
Fast blinking – Switch is identifying itself.
Off – Disabled.
90 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 91
Glyph Name Color State and Meaning
This indicator is an LED only, not a combination LED and button.
Attention Amber Indicates these conditions:
On – Fault detected.
Off – No faults detected.
OK Green Indicates these conditions:
On – Switch is functional without fault.
Off – Switch is off or initializing.
Service Processor (SP)
Green Indicates these conditions:
On – SP is ready.
Slow blinking – SP is booting up.
Off – SP is powered off, resetting, or at fault.

Related Information

“Verify LED Status” on page 89
“Verify That the Switch Is Operational” on page 94
“Verify Connectivity” on page 96
“Log In to the Oracle Fabric Manager Interface” on page 106
“Log In to the Oracle Fabric OS Interface” on page 105
“Run the Oracle Fabric OS Configuration Wizard” on page 102
“Oracle Fabric OS Configuration Wizard Parameters” on page 104

1GBase-T Cable Status LEDs

1GBase-T Cable Status LEDs
The table shows the status of the 1GBase-T ports on the switch's port block above the power plugs.
Glyph Name Color State and Meaning
LNK/ACT Link and
activity
SPD Speed Green Indicates these conditions:
Green Indicates these conditions:
On – Link is up.
Intermittent flash – There is activity on the link.
Off – Link is down.
On – Link is at high speed.
Slow blinking – Link is at medium speed.
Off – Link is at slow speed.
Verifying Functionality 91
Page 92

Power Supply Status LEDs

Related Information

“Verify LED Status” on page 89
“Verify That the Switch Is Operational” on page 94
“Verify Connectivity” on page 96
“Log In to the Oracle Fabric Manager Interface” on page 106
“Log In to the Oracle Fabric OS Interface” on page 105
“Run the Oracle Fabric OS Configuration Wizard” on page 102
“Oracle Fabric OS Configuration Wizard Parameters” on page 104
Power Supply Status LEDs
Glyph Name Color State and Meaning
OK Green Indicates these conditions:
On – 12 VDC is supplied.
Off – No DC voltage is present.
Attention Amber Indicates these conditions:
On – Fault detected, 12 VDC shut down.
Off – No faults detected.
AC Green Indicates these conditions:
On – AC power present and good.
Off – AC power not present.

Related Information

“Verify LED Status” on page 89
“Verify That the Switch Is Operational” on page 94
“Verify Connectivity” on page 96
“Log In to the Oracle Fabric Manager Interface” on page 106
“Log In to the Oracle Fabric OS Interface” on page 105
“Run the Oracle Fabric OS Configuration Wizard” on page 102
“Oracle Fabric OS Configuration Wizard Parameters” on page 104
92 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 93

Fan Module Status LED

Glyph Name Color State and Meaning
Attention Amber Indicates these conditions:

Related Information

“Verify LED Status” on page 89
“Verify That the Switch Is Operational” on page 94
“Verify Connectivity” on page 96
“Log In to the Oracle Fabric Manager Interface” on page 106
“Log In to the Oracle Fabric OS Interface” on page 105
“Run the Oracle Fabric OS Configuration Wizard” on page 102
“Oracle Fabric OS Configuration Wizard Parameters” on page 104
Fan Module Status LED
On – Fault detected,
Off – No faults detected.

I/O Module Status LEDs

Glyph Name Color State and Meaning
Attention Amber Indicates these conditions:
OK Green Indicates these conditions:

Related Information

“Verify LED Status” on page 89
“Verify That the Switch Is Operational” on page 94
“Verify Connectivity” on page 96
“Log In to the Oracle Fabric Manager Interface” on page 106
“Log In to the Oracle Fabric OS Interface” on page 105
On – Fault detected.
Off – No faults detected.
On – I/O module is functional without fault.
Blinking – Module is initializing. Hot plug is not allowed in this state.
Off – I/O module is off or initializing.
Verifying Functionality 93
Page 94

I/O Module Port LEDs

“Run the Oracle Fabric OS Configuration Wizard” on page 102
“Oracle Fabric OS Configuration Wizard Parameters” on page 104
I/O Module Port LEDs
I/O modules have link, activity, and speed LEDs (LNK/ACT and SPD, respectively) that indicate the state of a physical connection or traffic on a port. Port LEDs glow when the port senses an electrical or optical signal, detects a negotiated link speed, or both. Each port has its own LED (s), and the information displayed by the LEDs differs depending on the type of I/O module. Refer to:
Oracle F2 Dual Port 16 Gb Fibre Channel Module User’s Guide
Oracle F2 10 Gb and 40 Gb Ethernet Module User’s Guide
Oracle F2 Quad Port 10GBASE-T Module User’s Guide
Oracle F2 Long Range InfiniBand Module User’s Guide

Verify That the Switch Is Operational

1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
Access the Oracle ILOM CLI.
See “Log In to the SP (SER MGT)” on page 82 or “Log In to the SP (Network
Management)” on page 86.
3.
Display the installed I/O modules.
-> show /SYS -t fru_description Target | Property | Value
------------------------------+------------------------+-------------------­/SYS/MB | fru_description | PCBA,NM3 F2-12,Management Board. /SYS/MODULES/MODULE0 | fru_description | PCBA,40GE/4x10GE,IO MODULE /SYS/MODULES/MODULE1 | fru_description | PCBA,40GE/4x10GE,IO MODULE /SYS/MODULES/MODULE3 | fru_description | PCBA,16GB FC,IO MODULE /SYS/MODULES/MODULE4 | fru_description | PCBA,16GB FC,IO MODULE /SYS/MODULES/MODULE6 | fru_description | PCBA,IB LR,IO MODULE /SYS/MODULES/MODULE7 | fru_description | PCBA,IB LR,IO MODULE /SYS/MODULES/MODULE9 | fru_description | PCBA,10GBASE-T,IO MODULE /SYS/MODULES/MODULE10 | fru_description | PCBA,10GBASE-T,IO MODULE /SYS/PS0 | fru_description | A261_POWER_SUPPLY
94 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 95
Verify That the Switch Is Operational
/SYS/PS1 | fru_description | A261_POWER_SUPPLY /SYS/SP | fru_description | PCA,PILOT3 SP, OPUS
->
Note - If an I/O module is not installed in a slot, that slot is not reported.
4.
Check the health of the switch.
-> show /System -t health Target | Property | Value
---------------------------------------------+-----------+------­/System | health | OK /System/Power | health | OK /System/Power/Power_Supplies/Power_Supply_0 | health | OK /System/Power/Power_Supplies/Power_Supply_1 | health | OK /System/Cooling | health | OK /System/Cooling/Fans/Fan_0 | health | OK /System/Cooling/Fans/Fan_1 | health | OK /System/Cooling/Fans/Fan_2 | health | OK /System/Cooling/Fans/Fan_3 | health | OK /System/Cooling/Fans/Fan_4 | health | OK /System/Cooling/Fans/Fan_5 | health | OK /System/Cooling/Fans/Fan_6 | health | OK /System/Cooling/Fans/Fan_7 | health | OK /System/Networking | health | OK /System/Networking/Switches/Switch_0 | health | OK /System/Networking/Switches/Switch_1 | health | OK /System/Networking/Modules/Module_0 | health | OK /System/Networking/Modules/Module_1 | health | OK /System/Networking/Modules/Module_3 | health | OK /System/Networking/Modules/Module_4 | health | OK /System/Networking/Modules/Module_6 | health | OK /System/Networking/Modules/Module_7 | health | OK /System/Networking/Modules/Module_9 | health | OK /System/Networking/Modules/Module_10 | health | OK
->
Note - If an I/O module is not installed in a slot, that slot is not reported.
5.
If any target has a health value other than OK, investigate why.
Refer to detecting and managing faults in the Oracle Fabric Interconnect F2-12 Service Manual.
6.
Identify any open problems.
-> show /System/Open_Problems Open Problems (0)
Verifying Functionality 95
Page 96

Verify Connectivity

7.
8.
Date/Time Subsystems Component
------------------------ ------------------ ------------
->
If any open problems are discovered, investigate the problem.
Refer to detecting and managing faults in the Oracle Fabric Interconnect F2-12 Service Manual.
Verify the switch's connectivity.
See “Verify Connectivity” on page 96.
Related Information
“Verify LED Status” on page 89
“Verify Connectivity” on page 96
“Log In to the Oracle Fabric Manager Interface” on page 106
“Log In to the Oracle Fabric OS Interface” on page 105
“Run the Oracle Fabric OS Configuration Wizard” on page 102
“Oracle Fabric OS Configuration Wizard Parameters” on page 104
Verify Connectivity
1.
Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.
See “Installation Task Overview” on page 11.
2.
If you are at the switch, check the LEDs of the 1GBASE-T RJ-45 connectors and I/O modules.
See:
“1GBase-T Cable Status LEDs” on page 91
“I/O Module Status LEDs” on page 93
3.
Access the Oracle ILOM CLI.
See “Log In to the SP (SER MGT)” on page 82 or “Log In to the SP (Network
Management)” on page 86.
4.
Verify Ethernet connectivity.
a.
Start the EMS console.
-> start /System/Networking/Switches/Switch_0/fs_cli Are you sure you want to start /System/Networking/Switches/Switch_0/fs_cli (y/n)? y
96 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 97
Management Switch for Oracle Fabric Interconnect F2-12 SEFOS login:
b.
Log in to SEFOS.
SEFOS login: root Password: admin123 SEFOS#
The default password is admin123.
c.
Display the state of the Ethernet ports.
SEFOS# show interfaces status
Port Status Duplex Speed Negotiation Capability
--- ------ ------ ----- ----------- ---------­Gi0/1 connected Full 1 Gbps Auto Auto-MDIX on Gi0/2 not connected Half - Auto Auto-MDIX on Gi0/3 not connected Half - Auto Auto-MDIX on Gi0/4 not connected Half - Auto Auto-MDIX on Gi0/5 connected Full 1 Gbps Auto Auto-MDIX on Gi0/6 connected Full 1 Gbps Auto Auto-MDIX on Gi0/7 not connected Half - Auto Auto-MDIX on Gi0/8 connected Full 1 Gbps Auto Auto-MDIX on Gi0/9 connected Full 1 Gbps Auto Auto-MDIX on Gi0/10 not connected Half - Auto Auto-MDIX on Gi0/11 connected Full 1 Gbps Auto Auto-MDIX on Gi0/12 connected Full 1 Gbps Auto Auto-MDIX on Gi0/13 not connected Half - Auto Auto-MDIX on Gi0/14 connected Full 1 Gbps Auto Auto-MDIX on Gi0/15 connected Full 1 Gbps Auto Auto-MDIX on Gi0/16 not connected Half - Auto Auto-MDIX on Gi0/17 connected Full 1 Gbps Auto Auto-MDIX on Gi0/18 connected Full 1 Gbps Auto Auto-MDIX on SEFOS#
Verify Connectivity
In the output:
Port – Port of the EMS module as connected to chassis components.
Gi0/1 to Gi0/4 – Four 1GBASE-T ports on the left rear of the switch.
Gi0/5 to Gi0/11 – One port per slot on the rear panel. Gi0/5 is connected to slot 0, and Gi0/16 is connected to slot 11.
Gi0/17 and Gi0/18 are internal to the switch architecture.
Status – State of the port.
Duplex, Speed, and Negotiation – Parameters of the link.
Capability – Indicates if auto-crossover capability is on.
Verifying Functionality 97
Page 98
Verify Connectivity
5.
d.
If the output of a known installed card is not connected, or the status of a known-connected port is anything other than connected, investigate why.
Refer to detecting and managing faults in the Oracle Fabric Interconnect F2-12 Service Manual and to the EMS module documentation.
e.
Exit the EMS console.
SEFOS# exit Connection closed by foreign host
Entering character mode Escape character is '^]'. start: The session with /System/Networking/Switches/Switch_0/fs_cli has ended.
->
Verify configuration.
a.
Start the host.
-> start /HOST/console Are you sure you want to start /HOST/console (y/n)? y  Serial console started. To stop, type ESC (
b.
Press Enter to display the login prompt.
hostname login: Password:
where hostname is the host name of the SCP.
c.
Use the appropriate option to complete the login prompt:
If this is the first time you have booted up the virtualization switch, complete the Oracle Fabric OS configuration wizard.
See “Run the Oracle Fabric OS Configuration Wizard” on page 102
If you have already completed the Oracle Fabric OS configuration
wizard, log in as admin with password that was configured through the Oracle Fabric OS configuration wizard.
hostname login: admin Password: password
Welcome to OFOS Controller Copyright (c) 2012, 2016, Oracle and/or its affiliates. All rights reserved.
98 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Page 99
Verify Connectivity
Enter "help" for information on available commands.
Enter the command "show system copyright" for licensing information
admin@hostname[OFOS]
Note - From here forward in this document, the admin@hostname[OFOS] prompt is replaced
with simply [OFOS].
d.
Display the state of the I/O modules.
[OFOS] show iocards slot state descr type v-resources
-------------------------------------------------------------------------------­0 up/up gwEthernet4Port40GbCard 0 1 up/up gwEthernet4Port40GbCard 0 3 up/up sanFc2Port16GbCard 0 4 up/up sanFc2Port16GbCard 0 6 up/up ibLr4Port100GbCard 7 up/up ibLr4Port100GbCard 9 up/up gwEthernet4Port10GbCard 0 10 up/up gwEthernet4Port10GbCard 0 embedded up/up spineIb4Gw2PortCard 0 9 records displayed [OFOS]
In the output:
slot – Slot number as seen on the rear panel.
state– Operational and administrative state of the I/O module in the listed slot.
descr – An optional description of the module or slot.
type – Type of module installed in the slot.
gwEthernet4Port40GbCard – Oracle F2 10 Gb and 40 Gb Ethernet module
sanFc2Port16GbCard – Oracle F2 Dual Port 16Gb Fibre Channel module
ibLr4Port100GbCard – Oracle F2 Long Range InfiniBand module
gwEthernet4Port10GbCard – Oracle F2 Quad Port 10GBASE-T module
spineIb4Gw2PortCard – The interfaces at the left rear of the switch.
v-resources – Indicates a value for internal switch use. This value is not useful to customers.
e.
If the output displays a known installed card as not identified, or if a slot is in a down state, investigate why.
Refer to detecting and managing faults in the Oracle Fabric Interconnect F2-12 Service Manual.
Verifying Functionality 99
Page 100
Verify Connectivity
6.
Verify connectivity.
a.
Display the state of the gateway ports.
[OFOS] show ioports name type state descr v-resources
------------------------------------------------------------------------------
0/1 gwEthernet40GbPort up/up 0 0/2 gwEthernet40GbPort up/up 0 0/3 gwEthernet40GbPort up/up 0 0/4 gwEthernet40GbPort up/up 0 1/1 gwEthernet40GbPort up/up 0 1/2 gwEthernet40GbPort up/up 0 1/3 gwEthernet40GbPort up/up 0 1/4 gwEthernet40GbPort up/up 0 3/1 sanFc16GbPort up/up 0 3/2 sanFc16GbPort up/up 0 4/1 sanFc16GbPort up/up 0 4/2 sanFc16GbPort up/up 0 9/1 gwEthernet10GbPort up/up 0 9/2 gwEthernet10GbPort up/up 0 9/3 gwEthernet10GbPort up/up 0 9/4 gwEthernet10GbPort up/up 0 10/1 gwEthernet10GbPort up/up 0 10/2 gwEthernet10GbPort up/up 0 10/3 gwEthernet10GbPort up/up 0 10/4 gwEthernet10GbPort up/up 0 embedded/5 gwEthernet40GbPort up/up 0 embedded/6 gwEthernet40GbPort up/up 0 22 records displayed [OFOS]
In the output:
name – Slot number and port as seen on the rear panel/port number for the interface.
Note - In the output, embedded is the group of on-board interfaces at the left rear of the
switch.
type – Type of gateway available in the slot.
gwEthernet40GbPort – 40 Gb Ethernet
gwEthernet10GbPort – 10 Gb Ethernet
sanFc16GbPort – 16 Gb Fibre Channel
state– Operational and administrative state of the I/O module in the listed slot.
descr – An optional description of the module or slot.
100 Oracle Fabric Interconnect F2-12 Installation Guide • November 2016