OPTI-UPS PS1250C, PS1000C, PS2000C, PS1500C, PS3000C User Manual

Series
Standby UPS
PS1000C / PS1250C / PS1500C / PS2000C / PS3000C
UPS Series
Line Interactive
On Line UPS
AVR Series
Inverter Series
Specifications
Typology On-battery Output Wave Form INPUT Capacity Voltage Frequency OUTPUT Voltage (on battery) Frequency (on battery)
Series
Voltage Regulation AVR
PROTECTION & FILTERING Spike Protection Unit Input EMI/RFI filter Overload protection
Transfer Time Short Circuit BATTERY Type User Replaceable Battery Typical Recharge Time Protection
Back-up Time ALARM Battery Back-Up Battery Low Overload INTERFACE RS-232 Interface USB Dry Contact SNMP Slot ENVIRONMENT Ambient Operation Audible noise Storage condition PHYSICAL Weight (Net/Gross) (lbs) (Kg)
Dimension (Physical/ Packing) (L x W x H)
(one PC and one 17” LCD monitor)
PS1000C PS1250C PS1500C PS2000C PS3000C
1000VA/600W 1250VA/750W 1500VA/900W 2000VA/1200W 3000VA/1800W
(mm)
100 / 110 / 120 Vac or 220 / 230 / 240 Vac +/-25% (PS3000C 220V/230V/240V only)
AVR automatically increases output voltage 15% above input voltage when input voltage
drops lower than 9% from nominal. AVR decreases output voltage 13% below input voltage
30 min. 35 min. 40 min. 45 min. 90 min.
Sends AC fail and battery low singals, and receives shutdown signal from computer
(in)
3,500 meters max. elevation, 0%-95% humidity non-condensing, Temperature: 0-40ºC
35.0/36.1 33.1/36.2 33.1/36.2 62.6/66.1
13.9/15.3 15.0/16.4 15.0/16.4 28.4/30.3
50 or 60Hz +/-5% (auto sensing)
Pure Sine wave output at nominal +/-5%
when input voltage rises higher than 9% from nominal.
420 Joules (IEC models) / 225 Joules (NEMA models), 8/20μs
UPS automatic shutdown if overload exceeds 110% of nominal
6~8 milliseconds (typical), including detection time
UPS output cut off immediately or input circuit breaker protection
Hot swappable, Sealed, Maintenance-free lead acid
12V / 7.2AH x 2
14.9 x 5.5 x 7.9 / 19.2 x 10.6 x 12.8 378 x 140 x 201 / 487 x 270 x 326
Line-Interactive Pure Sine Wave
50 or 60Hz +/-0.5%
Circuit breaker protection
10dB at 0.15MHz, 50dB at 30MHz
for 20 second and 125% for 2 seconds
4 hours (to 90% of full capacity)
Automatic self-test & discharge protection,
“Replace battery” indicator
Slow beeping sound (about 0.25Hz) Rapid beeping sound (about 1.00Hz)
Continuous beeping sound
Yes Yes
Yes
<45dBA (1 meter from surface)
15,000 meters max. elevation
12V / 34W x 2
17.7 x 6.7 x 8.9 / 22.0 x 11.8x 14.2
450 x 170 x 226 / 560 x 300 x 360
12V / 34W x 4
* PS1000C / PS1250C / PS1500C / PS2000C / PS3000C
windows
2000 / XP
Sine Wave
Front Panel
PS1000C / PS1250C / PS1500C / PS2000C / PS3000C
Surge Series
Battery Capacity
Overload
Backup Replace Battery
Series
Green Power
Series
Networking
Load
Buck AVR Line Normal Boost AVR
On / Test
OFF
USB
TEL / Modem
Output
AC Input
Rear Panel
PS1000C / PS1250C / PS1500C / PS2000C
RS232
TEL / Modem
Output
AC Input
PS3000C
26.
SNMP Port
Battery Pack
Input Circuit Breaker
Battery Pack
USB
Input Circuit Breaker
USB
RS232
TEL / Modem
SNMP Port
Output
RS232
SNMP Port
Battery Pack
Input Circuit Breaker
Loading...