Opticon CRD 13 User Manual

CRD-13
Quick Start Guide
Introduction
• The CRD-13 is a designated charging and communication cradle for the H-13.
• Read this quick start guide carefully before installing and/or using this product.
• Keep this quick start guide for future reference and store it in a safe place.
Notice
• This quick start guide may be revised or withdrawn at any time without prior notice.
• This quick star t guide may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon.
• Trademarks used are property of their respective owners.
• Under no circumstances shall Opticon be held responsible for any special, incidental, consequential or indirect damages howsoever caused.
Cautions and Warnings
1. Handling Instructions
• Do not atte mpt to disassemble, modify or update this device.
• Do not use this device near combustible materials.
• Use only the AC adapter specified for this product.
• Do not drop this pro duct or put heavy items on this product.
• Keep the device out of the reach of small children.
• Do not damage the AC adapter or power cable by bending, twisting, pulling, or heating. Do not use them if they are s eriously damaged.
• Do not store this device in an ex tremely cold or hot environment.
• Do not touch the AC adapter or power cable while your hands are wet.
• Do not insert foreign substances into the device.
• Do not charge the battery in temperatures l ess than 0 deg. C or greater than 40 deg. C.
• Keep the IrDA communication window clean to avo id communication problems.
• When clea ning thi s prod uct , ru b gently wi th eit her a soft dr y cl oth or a damp cl ot h with mi ld deterge nt.
• Do not use this product in the following areas:
- In areas exposed to direc t sunlight for long periods of time.
- Near water or other liquids, or in extremely high humi dit y.
- Near heat sources, such as radiators, heat registers, stoves, or other types of devices that produce heat.
( Please refer to the specification manual for details.)
Before Getting Started
Whatʼs in the Box
Confirm that you have the following items before getting started:
No. Item Function
1 Cradle
2 AC/DC Adapter Designated AC/DC adapter with a replaceable plug for the CRD-13.
3 RS-232C Cable Designated RS-232C cable for the CRD-13.
4 USB Cable Designated USB cable for the CRD-13.
5 Quick Start Guide
* The n umber of accessori es may di ffer d epending on the pr oduct specifica tion. Plea se contac t the nea rest deal er if accessori es are da maged or missin g.
Copyright© 2008 OPTO ELECTRONICS CO., LTD. All rights reserved.
Designated charging an d communication cradle for the H-13.
Provides product infor mation and inst ruction guide.
CRD-13 Basic Specifications
Parameter Specifications
Physical Features
Control Section
Comm. Section
(H-13-CRD-13)
Comm. Section
(CRD-13- Host)
Size (H)64.9
Weight Approx. 125g
CPU 32bit RI SC CPU
Internal Memory
1
IrDA
RS-232C
2
USB
Power Supply Section
Main Power Supply
Current Consumption
Charging Time
Power Feed Section
Display Section
Durability
For Charging the Portable Terminal
LED
Operating Temp.
Operating Humidity
Storage Temp.
Storage Humidity
Charging Temp.
Shock Endurance
1
B aud Rate: Theoreti cal fi gure
2
RS-232C baud rate synchronizes with IrDA baud rate.
3
Can be switched ON/OFF using the detection switch.
To avoid communication problems between the cradle and a portable terminal, keep the IrDA window clean.
Memo
IrDA communication performance may decline due to excessive ambient light (especially under strong sunlight or inverted fluorescent light.)
AC adapter Basic Specifications
×
(W)70.0×(D) 144.4mm
ROM : 2 56KB RAM : 6 4KB
IrDA Ver1.2 (physical layer only)
Baud rate: SiR : 9600 to 115.2kbps FiR : 4Mbps
Baud rate: 9600 bps
19.2, 38.4, 57.6,115.2 kbps
Ver2.0 (Full-Speed)
Virtual COM
AC Adapter : DC 6.0V, 2.0A
When communicating : 110mA or less (DC 6.0V, when not charging)
Max: 1.7A or less (when charging a portable terminal)
Approx. 3 hours
Output: DC 6.0V (Typ.)
3
Electrical terminals : + / -
Power Supply : Red / Green
Data communication : Red / Green
-10 deg. C to 50 deg. C
25% to 85% (non-condensing)
-20 deg. C to 60 deg. C
20% to 90% ( non-condensing)
0 deg. C to 40 deg. C
Dr opped onc e from eac h of 6 angles onto concrete from a height of 75cm with no defects found.
Parameter Specifications
AC adapter
Input
Output
Power Voltage: AC 90 to 265V
Current Consumption: 0.5A max.
Power Voltage: 5.7 to 6.3V
Maximum current: 2.0A max.
Overview
Detailed View
No. Part Function
Power Supply
Status LED
Comm. Status LED
IrDA Communication
Window
Detection Switch
Portable Terminal Charging
Terminals
Guard Bar
Product Label
DIP Switches
DC jack
USB Connector
RS-232C Connector
Alerts users to the status of power distribution from the AC adapter to the cradle.
Alerts user s to the status of the IrDA data transmission.
Th e c radl e c ommu nica tes with the designated portable ter minal thr ough the I rDA communication window.
Term inal d etec tion s witch to cha nge the set tings o f the power feeding sectio n.
Electrical terminals for power distribution to the designated portable terminal.
To protect the USB, RS-232C cables and DC jack.
DIP switches to configure the settings of the CRD-13. Refer to the DIP Switch Configuration for details.
DC6.0V power s upply jack . Please us e the AC adapter.
Connector for U SB interface.
Connector for RS-232C cable.