180° Panoramic Outdoor Detector
WX Infinity Series
180° detection area, adjustable 8 to 40 range
Individual le / right side settings
2 hardwired & 3 wireless models available
Comprehensive Exterior Sensing Solution
The OPTEX WXI Series is a family of external sensors built upon our years of proven experience.
The series utilizes both analog and digital technologies to detect approaching intruders before
they gain access into your protected area.
With its comprehensive 180° field of view and capabilities to tailor its settings to meet the
environment around your premise, the WXI Series will provide an effective solution for new
and existing security systems.

180° Wall-to-Wall Coverage
Complete coverage & flexibility to eliminate blind spots
Individual Le/Right Settings
Individual Alarm Outputs
An installation of a WXI values 2 detectors because it trig gers alarm
signals both le and right side individually So it’s useful for PTZ
activation, direction recognition and changing detection pattern by day
and night with a CP.
Individual Sensitivity Setting
Detection sensitivity can be set to High, Medium and Low by le and
right switches individually.
High sensitivity Low sensitivity
Reliability
Self-Learning IR Digital Anti-Masking Function
WXI detects covering objects on lens surface. IR digital anti-masking
function optimizes trigger level of trouble outputs generated by masking
depends on status of lens surface. A well-calibrated adjustment for both of
emitting and receiving level of IR LED fluctuating by temperature contributes
to stable anti-masking.
Trouble
signal
Individual Detection Area Size
Detection distance can be easily adjusted
between 2.5m(8) and 12m(40) by le and right
sliding lower PIR units individually.
12m
Sunlight canceling
The trigger level of
anti-masking is automatically
adjusted when sunlig ht is too
strong.
Rainwater and insect
canceling
Small objects such as a spider
or rainwater can be cancelled.
6m
Tri gge r
UP
Time
AND Logic Function To Reduce False Alarms
WXI only triggers an alarm signal when both upper and lower detection
areas detect movement.
No detection Detection
SMDA Logic
(Super Multidimensional Analysis)
It can differentiate among various noise
factors such as climate changes and
vegetation sways and
genuine intrusions.
etc.
No detection Detection

Easy And Flexible Detection Area Settings
Area Masking Shutter
By rotar y sliding area masking
shutter, the size of detection areas
can be changed.
a n
b
c
d k
e
f
g
When are a maskin g shut ter’s position is th at Le is d and rig ht is k,
detec tion area a- d and k-n are mas ked.
i
h
Mechanical Features
EOL module socket (WXI-ST, AM only)
Optional EOL (end of line) resistor
modules are available.
Wide LED window
Wide and bright LED for a recognition
from a distance.
Area Masking Plate
Unwanted detection areas
can be masked by optional
area masking plate
(MKP-01).
m
l
j
a n
b
c
d k
e
f
g
When a MKP- 01 is set on position h,
detec tion area h is masked.
i
h
m
l
j
Back tamper
A tamper output is generated when unit is
removed from the wall.
Pole mount plate
(option PMP-01)
Suitable for a metal band up
to 23 mm (1 inch)
in width.
Screw free design
You can open / close front
cover and remove / put
main unit without any
screws. It contributes to
reduction of installation
time
Easy open Remove / put main unit Auto lock
PULL PUSH
Applications
For residential For rooop For substation
Basic Common Features
・Double conductive shielding
・Cover tamper
Web based manual
for wired models
http://navi.optex.net/manual/50196
Web based manual
for battery operated models
http://navi.optex.net/manual/50198
Automatic walk test
It automatically begins
when you close front
cover and ends aer 3
minutes.

Coverage
Unit: m (.)
Top view
12.0
(40)
a
10.0
(33)
(17)
5.0
0
5.0
(17)
b
c
d
e
f
g
i
h
12.0
10.0
(40)
(33)
0
n
m
5.0 (17)
l
k
j
10.0 (33)
12.0 (40)
Side view
2.5 m (8 )
3.5 m (12 .)
6.0 m(20 .)
8.5 m(28 .)
12.0 m(40 .)
1.0
(3)
0 5.0
(17)
0 5.0 10.0 12.0
0 5.0 10.0 12.0
0 5.0 10.0 12.0
0 5.0 10.0 12.0
10.0
(33)
12.0
(40)
Specifications
Model
Detection method
PIR coverage
PIR zones
PIR distance limit
Detectable speed
Sensitivity
Power input
Current draw
Alarm period
Warm-up period
Alarm (R) output
Alarm (L) output
Trouble output
Tamper output
LED indicator
(DIP switch ON or Walk test)
Operation temperature
Environment humidity
International protection
Mounting
Mounting height
Weight
Accessories
・Specifications and designs are subject to change without prior notice.
・These units are designed to detect an intruder and activate an alarm control panel.
Being only a part of a complete system, we cannot accept responsibility for any damages or
consequences resulting from an intrusion.
WXI-ST
2.0 °C (3.6°F) at 0.6 m/s Selectable for each side individually
21 mA max. at 12 VDC
[Individual;Right or General], [N.O. or N.C.] are selectable
[Individual;Left or General], [N.O. or N.C.] are selectable
-
Open when either the cover, main or base unit is removed
Red LED ; 1. Warm-up
2. Alarm
420 g (14.8 oz.)
Mounting screw (4 x 20 mm) x 2, lock screw x 1
Passive infrared
Horizontal 14 pairs, vertical 2 layers
2.5 to 12 m (Stepless adjustment)
0.3 to 2.0 m/s (1' to 6'7"/s)
9.5 to 18 VDC
60 sec. or less (LED blinks)
28 VDC 0.1 A max.
28 VDC 0.1 A max.
N.C. 28 VDC 0.1 A max.
-30 °C to +60 °C (-22°F to +140°F)
Wall, Pole (Outdoor, Indoor)
0.8 to 1.2 m (2'7" to 4')
Dimensions
Wired Model
Wireless transmitter
& battery
Options
Pole mount plate
(PMP-01)
180° wide
2.0 ±1 sec.
Red LED ; 1. Warm-up
95% max.
IP 55
other
81.2 (3.20)
81.5 (3.21)
200 (7.88)
119
125
WXI-AM
23 mA max. at 12 VDC
N.C. 28 VDC 0.1 A max.
2. Alarm
3. Masking detection
440 g (15.5 oz.)
Interval (sec.)
CR123A (3V DC, 1300 mAh)
CR2 (3V DC, 750 mAh)
1/2AA (3.6V DC, 1000 mAh)
Battery holder
(BH-01)
Battery Operated Model
8.7 (0.34)
119.2 (4.69)
81.5 (3.21)
68 (2.68)
83.5 (3.29)
35
119
130
52
Cover lens
(WXI-CL)
2.0 °C (3.6°F) at 0.6 m/s Selectable for each side individually
15 µA stand-by 4 max. at 3 V DC
except walk test
[Individual;Right or General], [N.O. or N.C.] are selectable
[Individual;Left or General], [N.O. or N.C.] are selectable
Red LED ; 1. Warm-up
Connector for POWER and ALARM (R), Connector for ALARM (L)
120
5
3
4
200 (7.88)
100 (3.94)
with BH-01
25.5
89
52
WXI-R
Horizontal 14 pairs, vertical 2 layers
2.5 to 12 m (Stepless adjustment)
Solid-state switch, 10 V DC 0.01 A max.
Solid-state switch, 10 V DC 0.01 A max.
Solid-state switch, 10 V DC 0.01 A max.
Tamper output is shared with trouble output.
2. Alarm
-30 °C to +60 °C (-22°F to +140°F)
Connector for TROUBLE, Velcro tape
Mounting screw (4 x 20 mm) x 2, Lock screw x 1
119
Back box
(WXI-BB)
Passive infrared
0.3 to 2.0 m/s (1' to 6'7"/s)
3 to 3.6 V DC lithium batteries
60 sec. or less (LED blinks)
[N.O. or N.C.] is selectable
except batteries
Wall, Pole (Outdoor, Indoor)
0.8 to 1.2 m (2'7" to 4')
600 g (21.2 oz.)
5
3.5
2
2.5
WXI-RAM WXI-RAMi
180° wide
16 µA stand-by 4 max. at
3 V DC except walk test
2.0 ±1 sec.
Red LED ; 1. Warm-up
95% max.
IP 55
35
52
2. Alarm
3. Masking detection
WXI-RAM / WXI-RAMiWXI-R
120
5
3
4
Unit: mm (inch)
83.5 (3.29)
Area masking plate
(MKP-01)
25 µA stand-by 74 max. at
3 V DC except walk test
Unit: years (approx.)
5
3.5
2
2.5
68 (2.68)
100 (3.94)
800.966.7839
sales@optexamerica.com
www.optexamerica.com