Optex URX-P01WH, URX-P01BL Installation Instructions And Operators Manual

INSTALLATION INSTRUCTIONS
No. 59-2412-0
Warning
Caution
1
PARTS IDENTIFICATION
2
INSTALLATION HINTS
- 1-
URX-P01WH : WHITE LENS MODEL URX-P01BL : BLACK LENS MODEL
URX-P01
URX-P01
Lens
Wall/Ceiling Bracket
[Main unit] [Back case]
[Bracket] [Cover key]
[Screws x2]
Ø4 x 30L
Included in the box
Install at a place detection area is directed to the route of intrusion.
LED
0
0 35 ft302010
10 m
5 m
10
15 ft
0
10
15 ft
5 m
0 m
3.0 m
2.4 m 10 ft
1.8 m
10 m
(32.8 ft)
5 m
(16.4 ft)
0
8 ft
6 ft
0 ft
123 4 5 6 7 8 9 10
3
DETECTION AREA
4
INSTALLATION
Features
• Ultra Wide Band technology detector using 9 Ghz frequency band.
• Low false alarm risk by installed temperature fluctuations.
• Easy range selector up to 10 m/ 33 ft detection range
• Bracket included for easy angle setting.
• Self-Check function (Output when failure conditions)
ULTRA WIDE BAND IMPULSE RADAR TECHNOLOGY TIME-OF-FLIGHT INDOOR DETECTOR
ULTRA WIDE BAND IMPULSE RADAR TECHNOLOGY TIME-OF-FLIGHT INDOOR DETECTOR
Failure to follow the instructions provided with this indication and improper handling may cause death or serious injury.
Failure to follow the instructions provided with this indication and improper handling may cause injury and/or property damage.
Warning
Caution
Note>>
Adjust detection range if the site is smaller than 10 m x 10 m (33 ft x 33 ft).
Do not remove!
TOP VIEW
SIDE VIEW
Basic installation
Terminals
Range selector rotary switch
Intrusion route
Doorway
URX-P01
Note>>
Please refer to “ 6 SETTINGS” for range adjustment.
Caution
If detection area is set too wide, it may detect movements outside of the target area, which may cause false alarms. Adjust the detection area according to target area.
URX-P01
1.
2.
1. Hook the top.
2. Groove the bottom
[Main unit] [Back case]
Cover Key
[Ceiling installation]
[Wall installation]
STEP 1
Separate the main unit and the back case.
STEP 2
Assemble the back case and the bracket.
STEP 3
Wire to the terminals.
STEP 4
Assemble the main unit and the back case.
1
2
Wire the cable.
Assemble with the back case.
*When taking out of a box.
Note>>
Please refer to “ 8 TERMINALS” for details.
Model
Lens color
Detection method
Coverage
Mounting height
Detection speed
LED alarm indicator
Tamper alarm
Alarm output period
Warm-up period
Current consumption
Weight
Operating temperature
Environmental humidity
URX-P01
URX-P01WH : White URX-P01BL : Black
Impulse Radio (Ultra Wide Band)
2.0 ~ 3.0 m (6.5 to 10 ft)
0.3 ~ 1.5 m/sec. (1 to 5 ft/sec.)
Red LED ON When detecting, Switchable ON/OFF
2 sec.
Power input
Approx. Under 10 sec.
12 VDC (9.6 to 14.4 VDC)
30 mA (max.) at 12 VDC
Approx. 85 g (2.99 oz)
-10˚C to +50˚C (+14˚F to +122˚F)
95% max.
N.C. (30 VDC, 0.1A max.)
9
DIMENSIONS
11
COMPLIANCE
NOTE
This unit is designed to detect movement of an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion.
10
SPECIFICATIONS
Specifications and design are subject to change without prior notice.
10 m x 10 m (33 ft x 33 ft), 90˚ wide
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net/
OPTEX INC. (U.S.)
URL: http://www.optexamerica.com/
OPTEX DO BRASIL LTDA. (Brazil)
URL: http://www.optex.net/br/es/sec/
WIRE GAUGE 12 VDC 14 VDC
AWG 22 (0.33 mm2)
AWG 20 (0.52 mm
2
)
AWG 18 (0.83 mm
2
)
Model
Color
Angle (Default)
Angle (Max. range)
Min. angle adjustment
Installation location
GB-41
White
±50°
15°
2.5°
Wall, Ceiling
Horizontal
Vertical
Horizontal
Vertical
Horizontal
Vertical
Unit: mm (inch)
Alarm output
Gray
White
Green
Black
Red
Tamper
output
Alarm output
Power
input
Spare
NC COM NC COM (-) (+)
- 2-
FCC ID: Q54URXP01 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference. (2) This device must accept any interference received, including
interference that may cause undesired operation.
5
BRACKET ADJUSTMENT
8
TERMINALS
6
SETTINGS
7
WALK TEST
Note>>
Adjust correctly detector range according to site condition.
Angle adjustment lever
Adjustable
Lock
Power wire maximum length (using one unit on a single wire)
1
Set LED ON.
LED
ON
LED OFF
2
Conduct a walk test.
190 m
(620 ft)
300 m
(980 ft)
480 m
(1,570 ft)
420 m
(1,380 ft)
660 m
(2,170 ft)
1,050 m
(3,440 ft)
Terminals color
0
1
2 3
4
5
6
7
8
9
LED
ON
LED OFF
LED switch
Range selector rotary switch
10m
Switch
detection
Range
1m 2m 3m 4m 5m 6m 7m 8m 9m
0 1 2 3 4 5 6 7 8 9
N.C. (30 VDC, 0.1A max.)
Lever position
15°
50°
50°
Detector specifications
Bracket specifications
Note>>
60 (2.36)
95 (3.74)
109 (4.29)
0
1
2 3
4
5
6
7
8
9
Adjust bracket angle vertically can reduce the detection range.
Removing the bracket from the detector
1
Separate the main unit and the back case.
2
Push the hook downward.
3
Pull the back case forward.
103 (4.06)
112 (4.41)
124 (4.88)
1.
2.
Note>>
Caution
Conduct a walk test outside of the room to check there is no area outside.
Conduct a walk test at least once a year.