Optex SL-200TNRi, SL-200TNR, SL-100TNR, SL-100TNRi Installation Instructions

OPERATION CHECK
5-2
After installation is complete, be sure to check the operation.
Make sure that the Alarm/Level indicator LED is OFF.
1
If it is illuminated even when the beams are not blocked, make optical alignment again.
Check that the Power/Low battery indicator LEDs on both transmitter and
2
receiver are ON. If the Power/Low battery indicator LED is blinking, the battery power is low. Replace with new batteries.
Conduct a walk test to check that Alarm/Level indicator LED on the
3
receiver turns ON as the walker interrupts the beams.
TROUBLESHOOTING
6
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Power/Low battery indicator LEDs are not illuminated. (transmitter/receiver)
Alarm is not output.
When the beam is blocked, the “ALARM” indicator LED is illuminated but the alarm is not activated.
Alarm is activated even if the light is not blocked.
Batteries are running out too quickly. Set the cover properly.
Frost, snow or heavy rain causes false alarm.
Improper output Problem with wiring. Install the correct wiring.
Even if new batteries are used, Low battery indicator LED is ON.
SPECIFICATIONS
8
Model
Maximum detection range 30 m/100 ft.
Maximum arrival distance 265 m/800 ft.
Detection method Twin infrared beam interruption detection
Interruption time
Power source
Current draw
(stand by /at 25°C)
Battery
life
* **
Output
Indicator
LED
Specifications and design are subject to change without prior notice. * The value is based on the condition that it is used within the ambient temperature range of 20 to 25°C. ** Using batteries other than those recommended may shorten the battery life.
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net
3.9 VDC
3.0 VDC
SB-D02HP by VITZROCELL
CRH-5 (CR123A by Panasonic)
Alarm output
Alarm period 2 s (±1)
Low battery output
Cover tamper output (Receiver)
Alarm/ Level indicator (Receiver)
Power/ Low battery indicator (Transmitter and Receiver)
Operating temperature -20°C to +60°C (-4°F to 140°F)
Operating humidity 95 % (max.)
Alignment angle ±90° Horizontal, ±5° Vertical
Dimension
Weight
International protection IP65
Reversed battery polarity. Check the battery polarity.
5HÀHFWLRQIURPWKHÀRRURUZDOO
Beam has not been blocked. Block all two beams.
Signal line short-circuited Check the wiring.
Interruption time is too short.
Surface of Transmitter/Receiv­er cover soiled.
Optical alignment was not performed properly.
Problem with tamper output.
Optical alignment not optimized.
Batteries are inactive condition.
SL-100TNR SL-200TNR
Variable between 50/100/250/500 ms (4 steps)
3.9 VDC D size lithium batteries Each Transmitter and Receiver: 2 units (SB-D02HP manufactured by VITZROCELL)
3.0 VDC CR123A lithium batteries Each Transmitter and Receiver: 8 units (OPTION CRH-5: 2unit) Total: Approx. 500 μA Transmitter: Approx. 200 μA Receiver: Approx. 300 μA
Total: Approx. 600 μA Transmitter: Approx. 200 μA Receiver: Approx. 400 μA
Transmitter
Approx. 6 years
Receiver
Approx. 5 years
Transmitter
Approx. 1.5 years
Receiver
Approx. 1 year
Form C-Solid State Switch: 3.9 VDC, 0.01 A
N.C. (Solid State Switch): 3.9 VDC, 0.01 A
N.C. (Solid State Switch): 3.9 VDC, 0.01 A Opens when the battery cover removed.
ON: Beam not received Blinking: Beam not received sufficiently OFF: Beam received
ON: Power ON Blinking: Voltage reduction OFF: Power OFF
H × W × D mm (inch): 295 (11.6) × 69 (2.7) × 117 (4.6)
1200 g (Total weight of Transmitter + Receiver, excluding accessories)
OPTEX INC. (U.S.)
www.optexamerica.com
OPTEX DO BRASIL LTDA. (Brazil)
www.optex.net/br/es/sec
OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)
www.optex-europe.com
Transmitter
Align beams away from the floor or wall.
See “4-1 BEAM INTERRUPTION ADJUSTMENT” on page 3, set an appropriate interruption time.
Clean the cover (wipe the cover with a soft cloth dampened with water or diluted neutral detergent).
See “4-2 OPTICAL ALIGNMENT” on page 3 and make realignment.
See “4-2 OPTICAL ALIGNMENT” on page 3 and make realignment.
Open and close the battery cover 20 times with two seconds intervals. After this, open the battery plate and then close it.
60 m/200 ft.
530 m/1740 ft.
Total: Approx. 600 μA Transmitter: Approx. 300 μA Receiver: Approx. 300 μA
Total: Approx. 700 μA Transmitter: Approx. 300 μA Receiver: Approx. 400 μA
Approx. 5 years
Approx. 5 years
Approx. 1 year
Approx. 1 year
Receiver
A
B
C
DIMENSIONS
7
OPTIONS
9
BCU-5 Battery Common use Unit (1 unit/set)
Share power source and low battery signals between the main unit and the wireless transmitter.
CRH-5 CR123A Battery Holder (2 units/set)
Battery holder when using CR123A as a power source
PCU-5 Power Convertor Unit (1 unit/set, battery is sold separately.)
Voltage convertor unit used to enable wired operation of the detector
NOTE
These units are designed to detect an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion. These products conform to the EMC Directive 2004/108/EC.
OPTEX TECHNOLOGIES B.V. (The Netherlands)
www.optex.eu
OPTEX SECURITY SAS (France)
www.optex-security.com
OPTEX SECURITY Sp.z o.o. (Poland)
www.optex.com.pl
- 4 -
Be sure to conduct a walk test at the following three points: A. In front of the transmitter B. In front of the receiver C. At the mid point between the transmitter and receiver
The detector is installed properly when Alarm/Level indicator LED turns ON in the tests at all the three points.
69 (2.7)
(WALL)
Unit: mm (inch)
34 (1.3)
20 (0.8)
16 (0.6)
Unit: mm (inch)
56 (2.2)
Unit: mm (inch)
53 (2.1)
Unit: mm (inch)
83.5 (3.3)
26 (1.0)
295 (11.6)
117 (4.6)
55 (2.2)
34 (1.3)
71 (2.8)
OPTEX PINNACLE INDIA, PVT., LTD. (India)
www.optex.net/in/en/sec
OPTEX KOREA CO.,LTD. (Korea)
www.optexkorea.com
OPTEX (DONGGUAN) CO.,LTD. SHANGHAI OFFICE (China)
www.optexchina.com
Copyright (C) 2016 OPTEX CO., LTD.
BATTERY OPERATED
BATTERY OPERATED
PHOTOELECTRIC DETECTOR
PHOTOELECTRIC DETECTOR
Smart Line series
Smart Line series
• Battery operated detector
- D size lithium battery or CR123A lithium battery (OPTION CRH-5)
• Simplified optical adjustment
- Sniper View Finder with ×2 magnification
• Avoids having to install a wireless transmitter in the photoelectric transmitter.
- IR signal transmission technology transfers the low battery signal to the receiver Possible to connect the power and alarm cables to both the receiver and the transmitter or either of them
- OPTION PCU-5
INTRODUCTION
1
BEFORE YOUR OPERATION
1-1
Read this instruction manual carefully prior to installation.
After reading, store this manual carefully in an easily accessible place for reference.
This manual uses the following warning indications for correct use of the product, harm to you
or other people and damage to your assets, which are described below. Be sure to understand the description before reading the rest of this manual.
Indicates a potentially hazardous situation which, if not avoided, will result
Warning
Caution
1-2
. Do not install the
unit on an unstable surface.
1-3
Main unit cover lock screw
Battery cover lock screw
PREPARATIONS
2
Wired
* Refer to “9 OPTIONS” on page 4.
in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage.
This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.
This symbol requires an action or gives an instruction.
This symbol indicates recommendation.
PRECAUTIONS
Do not install the pole in a location where sufficient stability can not be ensured.
Do not install the unit in trees, leaves, or other objects that may swing in the wind and block the beam.
Do not install the receiver in a location where it is exposed to direct sunlight.
PARTS IDENTIFICATION
Main unit cover
Optical lens
Optical alignment dial
Battery cover
Detector power source Battery type Wireless transmitter power source
Wireless
Either Transmitter or
Receiver
Both Transmitter and
Receiver
Main unit Back box
Viewfinder
Dip SW
(Receiver only)
D size
CR123A
D size
CR123A
From independence battery
From detector battery
From independence battery
From detector battery
From independence battery
From detector battery
From independence battery
From detector battery
From independence battery
Do not use the product for purposes other than the detection of moving objects such as people and vehicles. Do not use the product to activate a shutter, etc., which may cause an accident.
Do not touch the unit base or power terminals of the product with a wet hand (do not touch when the product is wet with rain, etc.). It may cause electric shock.
Never attempt to disassemble or repair the product. It may cause fire or damage to the devices.
Do not use batteries that have different levels of power remaining (i.e., new and used batteries). Not observing the above may result in an explosion, leakage of electrolyte, emission of toxic gases or other outcomes that may be harmful to people and property.
[Handling of Batteries] Do not recharge, short circuit, crush, disassemble, exceed heat above 100°C (212°F), incinerate, or expose contents to water. Do not solder directly to the cell.
Do not pour water over the product with a bucket, hose, etc. The water may enter, which may cause damage to the devices.
Clean and check the product periodically for safe use. If any problem is found, do not attempt to use the product as it is and have the product repaired by a professional engineer or electrician.
Do not allow the infrared beam from a another detector to reach the receiver.
Receiver
Receiver (another detector)
Main unit mounting bracket
Wireless transmitter size
35 (1.4)
Unit: mm (inch)
- 1 -
INSTALLATION INSTRUCTIONS
MODEL SL-100 TNR SL-200 TNR
Long battery life
Battery saving function
Intermittent output function
Slim body design
Easy to see vivid interior color
for optical alignment
Install the unit at a height where an object can be detected without fail.
Transmitter
Transmitter (another detector)
Accessories>>
47 (1.9)
4×20 self tapping for wall mounting (with rubber washer): 4
141 (5.6)
M4×16 screws for pole mounting (with rubber washer): 4
D-size
4 pcs.From detector battery
4 pcs.
2 pcs.
2 pcs.
BATTERY OPTION*
CR123A CRH-5 BCU-5 PCU-5
For Wireless transmitter
16 pcs.
16 pcs.
8 pcs.
8 pcs.
DETECTION RANGE
IP65 waterproof structure
Tamper function
Indicator LED for an easy alignment
Various options (Refer to page 4.)
(BCU-5, CRH-5, PCU-5)
Warning
Caution
The pole size should be 43 to 48 mm dia. (1.69 to 1.89 inch dia.).
Velcro tape: 1 set
No
Need
No
Need
No
Need
No
Need
No
Need
30m/100ft. 60m/200ft.
Install the unit at least 1 m (3.3 ft.) away from the wall or fence that may be running parallel to the beam.
1 m (3.3 ft.)
2 sets
2 sets
1 set
1 set
No. 59-2032-3
Cables: 3
U-brackets: 2Pole brackets: 2
1 set
1 set
1 set
1 set
1 set
1 set
1 set
1 set
1 set
2 sets
2 sets
INSTALLATION
3
3-1
SEPARATING
Remove the battery
1
cover.
1
Loosen the battery cover lock screw.
3-2
WALL MOUNTING
Using a screwdriver or similar tool, break
1
the knockout position (×2) in the back box as shown.
Knockout position
WALL
Open the screw holes from the inside of the back box to the outside.
Attach the connectors.
5
Note>>
• Avoid placing the cables in a position where they can be caught between the main unit and cover.
POLE MOUNTING
3-3
Using the guide below, break the knockout positions (×2) in the back box with a screwdriver.
1
Knockout position
WALL
Instruction
condition
One detector
Two detectors in
opposing directions
Remove the main unit
2
cover.
1
2
Pull
POLE (1)
POLE (2)
Loosen the main unit cover lock screw.
2
POLE (1)
POLE (2)
Replace batteries.
6
< When using D size battery >
Open the battery plate in the
1
direction of the arrow.
2
Insert the two batteries into their compartment. Ensure the positive terminals are facing toward the front.
3
Close the battery plate.
< When using CR123A battery >
Open the battery plate in the
1
direction of the arrow.
2
Set CR123A in the CRH-5 and insert two CRH-5 into their compartment. Ensure the positive terminals are facing toward the front.
3
Close the battery plate.
4
Connect the CRH-5 male connectors to the female connectors of the battery plate.
• Do not mix D size lithium batteries with CRH-5 batteries.
• Do not mix batteries that have different levels of power remaining (i.e., new and used batteries or batteries of different manufacturers). Not observing the above may result in an explosion, leakage of electrolyte, emission of toxic gases or other outcomes that may be harmful to people and property.
• Remove all batteries prior to replacing with new ones. If this is not followed, the low battery indicator LED will not reset and will continue to blink.
Disposal method for batteries
Dispose of used batteries in accordance with local government regulations/low and EU Battery Directive (2006/66/EU).
Open the screw holes from the inside of the back box to the outside.
Knockout position
Detector No. 1 Detector No. 2
POLE (1) -
POLE (1) POLE (2)
Remove the connectors.
3
Pull
Mount the back box to the wall.
2
Side wall
Distance from the side wall: at least 1m
4×20 self tapping (with rubber washer)
Warning
Caution
• If you accidentally open an unnecessary knockout, be sure to fill the knockout. Not doing so may result in waterproof failure and malfunction of the product.
3.9 VDC D size Lithium batteries
CRH-5
3.0 VDC CR123A
Caution
MOUNTING EXAMPLE AT PARTICULAR CASE
3-4
Avoid installing the transmitter and receiver facing each other through the corner of the cover.
1
Remove the main unit from the back box.
4
2
1
Turn the optical unit
1
90 degrees and loosen the screw.
Using Velcro tape, fix the wireless
3
transmitters in the back box. For more information on wiring, see “3-5 WIRING” on page 3.
Pitch: 83.5 mm For connection to gang electric box
Note>>
• When using BCU-4 (option), refer to BCU-4 manual.
3
1
2
4
7
8
• Do not touch the optical unit when mounting the cover. Otherwise, the resulting shift of the optical axis may result in malfunction of the unit and require readjustment.
Fix the back box on the pole.
2
Side wall
Distance from the side wall: at least 1m
M4×20 screw (with rubber washer)
3
2
Take the main unit out of the back box.
Velcro tape
Cut the supplied Velcro tape to an appropriate length and apply.
Referring to “4 SETTING” on page 3, perform the necessary settings.
Close the main unit cover.
1
Hook on the upper part of the back box.
2
Push the lower part of the main unit cover.
Fasten the main unit
3
cover lock screw.
Caution
Pole bracket
Pole 43 to 48 mm dia. (1.69 to 1.89 inch dia.)
Detector
No. 1
U-bracket
Remove the main unit mounting bracket.
5
Caution
• Do not place the main unit where it is exposed to direct sunlight. Doing so may cause damage to the product.
Mount the main unit.
4
3
4
Close the battery cover.
9
1
Close the battery cover.
2
2
Tighten the fixing screw for the battery cover.
• When closing the cover, be careful that the cables are not caught by the cover.
2
3
Detector
No. 2
Attach the main unit
1
mounting bracket to the back box.
1
Route the three connectors
2
of the back box through the slits on the upper part of the main unit.
3
Tighten the main unit fixing screw and turn the optical unit 90 degrees.
1
Just fit
Caution
Perform the wall
3
mounting procedure of 3 to 9 on page 2.
3-5
Receiver
Main unit
Red
Black
Yellow Orange Brown
Green Blue Purple Gray
Transmitter
Main unit
Red
Black
Green Blue
• When using BCU-5 (option), be sure to read the BCU-5 manual. Do not insert batteries into the wireless transmitter. Doing so may result in fire or explosion.
SETTINGS
4
4-1
DIP SWITCH
1
Receiver
SELECTOR POSITION
SL-TNR
BATTERY SAVING TIMER
3
The battery saving timer enforces 2 min intervals between alarm outputs. If the site of security involves a lot of traffic or in/out of people over a detection zone, wireless transmitters may wear out batteries quickly. The battery saving timer cancels alarms for two minutes after the initial output, preserving powers of wireless transmitters.
4-2
Optical alignment is an important procedure to increase reliability. Be sure to take alignment step 1 through 2 described below to attain the maximum level of the output through the monitor jack.
Look into the viewfinder and perform fine alignment of the horizontal and vertical
1
angles using the alignment dial.
Viewfinder
OPERATION CHECK
5
5-1
Alarm/Level indicator LED (Receiver only)
Note>>
• The operation of the Alarm/Level indicator LED will not change due to the battery saving timer setting. Whenever the beam is interrupted, the indicator will turn ON.
Transmitter Receiver
WIRING
Back box
Power
Main control
COM NC
Alarm
NO
Low battery
Tamper
Back box
Power Main control
Low battery
Warning
FUNCTIONS
(factory default)
Beam interruption adjustment switch 1 Beam interruption adjustment switch 2 Battery saving timer switch
ON
Intermittent output function switch
Note>>
• Do not press the tamper when you set the DIP switches. Otherwise the settings will not actually be changed.
OPTICAL ALIGNMENT
< Horizontal alignment >
Turn the horizontal alignment dial by fingers to make alignment
LED INDICATION
Beam Interruption
Alarm/Level indicator
Beam not
received sufficiently
LED
OFF
[ Top view ]
When connecting to BCU-5 (OPTION)
Receiver
Main unit Back box
Wireless
Transmitter
Wireless
Transmitter
Red
Black
Yellow Orange Brown
Green Blue Purple Gray
Transmitter
Main unit
Red
Black
Green Blue
Power Main control
Alarm
Low battery
Tam pe r
Back box
Power Main control
Low battery
Note>>
• To monitor low battery levels separately for the receiver and the transmitter, install a wireless transmitter in each of them. When the low battery levels are monitored for both the receiver and transmitter centrally, install a wireless transmitter in only the receiver.
• If there is only an N.O. output on a wireless transmitter, the low battery output and tamper output cannot be used.
• The power supply can be shared between the back box and wireless transmitter by using BCU-5 (option).
• When using PCU-5 (option) with either only the transmitter or receiver, ensure the low battery signal is monitored. (Refer to PCU-5 manual.)
Refer to “1-3 PARTS IDENTIFICATION”.
Receiver
ON
OFF
SL-TNR
• Alarm output: 1 output/ 2 minutes
Horizontal alignment angle Vertical alignment angle
90°
Note>>
90°
< How to look into the viewfinder >
From right side
Left eye
• Remove all batteries prior to replacing with new ones. If this is not followed, the low battery indicator LED will not reset and continue to blink.
5° 5°
From left side
Right eye
< Vertical alignment >
Turn the vertical alignment dial with a screwdriver to make alignment
Power/Low battery indicator LED
LEDDETECTOR
ON
(continue)
or
OFF
Transmitter
Transmitter
Caution
Checking of the illumination
• After the rough alignment using the view
< Receiver >
Fine adjustment with monitor jack
• After checking the receiving level of optical
< Receiver >
Power/Low battery indicator LED
- 2 -
In doing this installation, the maximum detection
2
range shall be half of the original detection range. (This is to compensate the attenuation of beam by the corner of the cover.)
Battery
Attach the BCU-5 to the
plate
BCU-5
EXEX – +
Through the center hole.
+
Wireless
–+
BCU-5
EXEX – +
Through the center hole.
Wireless
2
finder, check the light receiving status by the Alarm/Level Indicator.
axis by using the alarm indicator, make sure to make fine alignment for both transmitter and receiver with voltmeter until it reaches maximum monitor output over “Good” level.
–+
+
BEAM INTERRUPTION ADJUSTMENT
2
Initial setting is at 50 ms for normal work. According to the speed of a supposed target you select one specific setting out of 4 steps. Set the beam interruption adjustment switches of the Receiver according to the speed of the human object to detect.
INTERMITTENT OUTPUT FUNCTION
4
Intermittent output function enforces outputs to reset while beams continues to be interrupted. This function is effective if your wireless transmitters do not have supervised features to monitor relay status. Intermittent output function repeats alarms with intervals to let the system be aware of interrupted status.
Checking the Indicator LED and fine alignment
Set the voltmeter range to 5 to 10VDC and connect the voltmeter probes and to and of the monitor jack respectively.
Receiver
BATTERY
CONDITION
Normal
Receiver is low battery
Transmitter is
low battery
Both Receiver
and Transmitter
are low battery
Battery
plate
Alarm/Level Indicator LED
ON (continue)
battery plate using double-sided adhesive tape.
• Be careful not to cover the power/low battery indicator LED.
• Select a location that does not interfere with the connector installation.
Power/Low battery
indicator LED
Note>>
• When making the adjustments by the monitor jack, be careful not to cover the optical unit with your hand, the voltmeter pin cord, etc.
Alarm/Level
indicator
Adjustment
Monitor jack
output
The Alarm/Level indicator LED is a supporting tool for easy alignment. Be sure to perform fine alignment to ensure the maximum output level through the monitor jack.
• The Alarm/Level indicator LED should only be used for rough alignment. For fine or good alignment, always use the monitor jack output level.
LED
• • •
• • •
• • •
- 3 -
ex) SL-200TNR 60m/200ft. 30m/100ft.
When connecting to PCU-5 (OPTION)
This unit used to enable wired operation. For more information on connecting, see PCU-5 manual.
Note>>
• Route the cables through the center hole.
ON
SELECTOR
POSITION
SL-TNR
Running Jogging Walking Slow movement
(50 msec) (100 msec) (250 msec) (500 msec)
Typical interruption time setting
SL-TNR
• A
Beam
interrupted
ON Fast blink Slow blink OFF
LED
level
Realign Fair Good Excellent
0 V 0.1 VDC 2.0 VDC 2.8 VDC
Caution
Transmitter
BATTERY
CONDITION
Normal
Receiver is
low battery
Transmitter is
low battery
Both Receiver
and Transmitter
are low battery
Receiver
ON
OFF
larm output: 1 output/ 1 minute
Beam received
LED
ON (continue)
ON (continue)
• • •
• • •
Loading...