Optex SIP-4010, SIP-404, SIP-3020, SIP-3020CAMDN Installation

No. 59-1494-2 0911-01
2
INSTALLATION INSTRUCTIONS
INSTALLATION AND MAINTENANCE NOTES
Synthesized Intelligent PIR
Synthesized Intelligent PIR
REDWALL-V series
REDWALL-V series
FEATURES
* Intelligent PIR Detection System
- Detection of ambient temperature and illuminance for automatic sensitivity management
- Advanced detection algorithm
- Three dual pyro-elements with patented Double Conductive Shielding
* Anti-vandalism functions
- Anti-rotation function with 3-axis accelerometer
- Anti-masking function with photo-beam
- Reinforced polycarbonate housing
- Max. 4 m (13 ft.) installation height
* Independent sensitivity selector for near/far areas * Detection logic selector * Detection range selector * Independent N.C. and N.O. outputs * Adjustable alarm interval time
• SIP-3020CAM DN (EU), SIP-3020CAM DN (US) * High-quality camera image: Day (colour)/Night (B/W) * 480 TV lines * Varifocal lens 3-9 mm * Minimum illumination: Day (colour) 0.5 lx, Night (B/W): 0.03 lx
Warning Caution
Never repair or modify product
Nylon wire loop
When servicing, the sensor can be hooked onto the base using the nylon wire loop.
Caution Verify that the power is off before connecting the wiring.
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
REDWALL-V REDWATCH-V
: Synthesized Intelligent PIR
SIP-3020
• SIP-4010
• SIP-404
1
PARTS IDENTIFICATION
Base
Fixing screw for the base
Adjustment screws (two facing each other)
Main unit
Angle adjustment guide
: Synthesized Intelligent PIR
with D/N camera
SIP-3020CAM DN (EU)
• SIP-3020CAM DN (US)
Far area mirror
Masking plate for far area
Fixing rubber form
Window
Fixing rubber
form (*1) Masking plate for near area (*1)
Near area mirror
*1: Not used for the SIP-4010 and SIP-404.
SIP-3020CAM DN
Fixing screw for the cover
Cover
2-1
INSTALLATION HINTS
2.3-4.0 m (7.6-13 ft.)
Mount the detector so that the majority of traffi c fl ow is across the detection pattern.
Arrow marking
Fixing screw
Camera unit
- 1 -
3
INSTALLATION AND ANGLE ADJUSTMENT
3-1
Wall Mounting
Attach the paper template (an accessory) onto the wall,
(1)
and drill a 6-mm dia. mounting hole and a cabling hole. Insert the anchor bolt (an accessory) into the board mount hole.
Distance from the ground to the bottom of the template must be between 2.3 m (7.6 ft.) and 4 m (13 ft.).
Using an allen key, remove the main unit from the base.
(2)
4 Pull out.
2 Open.
3-2
Inside View of the Base
Main unit connector
Wall mounting hole
BNC terminal (SIP-3020CAM DN ONLY)
Wall mounting hole
Bushing of wiring hole
Base
Waterproof seal (Do not remove this seal.)
Wiring terminals
Bushing of wiring hole
Open wiring cap
1 Loosen the
xing screw for the base.
(3)
Drill through the bushing of the wiring hole, pass the cable through the hole, and secure the base to the wall.
(4)
Connect the cable to the terminal block (see Step 3-3).
(5)
Mount the main unit onto the base.
1 Insert and
secure here.
Nylon wire loop
3 Unplug
4 Tighten and
3 Close.
2 Connect the
connector.
Cautions>>
When mounting the main unit, take care not to trap the nylon wire loop. Also, take care not to get your fingers caught.
(6)
Check to see that the various settings and operations are correct.
Caution>>
When the red LED flashes after the power turns on, this signifies that the system is warming up. Wait for approximately 60 seconds.
the cable connector.
secure the xing screw for the base.
- 2 -
3-3
WIRING
BNC terminal (SIP-3020CAM DN ONLY)
POWER INPUT
TAMPER OUTPUT *1
ALARM OUTPUT (N.C.)
ALARM OUTPUT (N.O.)
*1: TAMPER terminals to be connected to a 24 hour supervisory loop.
Name Function
Trouble out is used for anti-masking signal. When
TROUBLE
OUTPUT
TAMPER OUTPUT
an object is placed close to the lens surface, for a period of more than 20 seconds (approx.), the IR anti-masking circuit will activate and generate a trouble signal.
It is detected when the cover is opened. It is detected when the main unit is removed from
its base. Anti-Rotation:
Damage sustained by the main unit is detected. When the system power switch is turned on while the cover is closed, the mounting position of the main unit itself will be determined and stored in memory after approximately 10 seconds. Then, if the main unit is impacted in a horizontal or vertical direction and if the position of the main unit has changed, damage sustained by the main unit will be detected. However, if you remove the cover while keeping the system power turned on, and if you close the cover again after correcting the position of the main unit, the new position of the main unit will be stored in memory after approximately 10 seconds.
TROUBLE OUTPUT
SPARE
D
Power wires should not exceed the following lengths.
SIP-3020CAM DN (EU) SIP-3020CAM DN (US)
WIRE SIZE
SIP-3020/SIP-4010/SIP-404
12V DC 14V DC 24V AC 12V DC
2
0.33 mm (AWG22)
0.52 mm (AWG20)
0.83 mm (AWG18)
4
DETECTION AREA SETTING
580
(1900)
2
910
(2990)
2
1450
(4760)
770
(2530)
1210
(3970)
1930
(6330)
1370
(4490)
2160
(7090)
3450
(11320)
You can adjust the detection area by 90 degrees in a horizontal direction and by 10 degrees in a vertical direction. Correct the vertical detection angle according to the mounting height of the sensor unit.
Applicable models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
100
(330)
160
(520)
250
(820)
SIP-3020CAM
m (ft.)
Adjust the angle of the main unit in a horizontal direction so
(1)
that you can cover the desired detection area.
3 Rotate the main unit.
1 Loosen the xing screw for
the base.
2 Loosen the adjustment screw. 4 Tighten the adjustment screw slightly.
(2)
Adjust the angle of the main unit in a vertical direction so that you can cover the desired detection area.
Align the arrow of the main unit with the “Angle adjustment guide” of the adjustment screw. The main unit is usually adjusted within the width of this guide.
When mounted at a height of
2.3 meters (7.6ft.)
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
10°
10°
90°
90°
10°
10°
90°
Applicable models
90°
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
Cautions>>
To rotate the main unit counterclockwise, loosen the RHside adjustment screw. To rotate the main unit clockwise, loosen the LH-side adjustment screw. Otherwise, you may find it difficult to tighten or you may find that you cannot tighten the adjustment screw when you are securing the main unit.
When mounted at a height of 4.0 meters (13ft.)
Cautions>>
If the mounting wall is at an angle, the arrow of the main unit may exceed the top or bottom limit of “Angle adjustment guide”. Always check this using the area viewfinder or the walk tester. If the detection area is too high or too low, an object outside the detection area may be detected or incorrect object detection may occur.
(3)
Remove the cover.
Hooks
3 Slide the cover downward
and release the hooks.
1 Loosen two fi xing screws for
the cover and pull out the cover until it stops.
Cover
2 Hold the heads of both cover fi xing screws with your
hands, and pull down and remove the bottom section of the cover from the main unit.
Adjustment screw
To rotate the unit counterclockwise
Cautions>>
The cover is linked to the main unit by nylon wire loop so that the cover does not fall. Do not pull the cover using excessive force.
To rotate the unit clockwise
- 3 -
Mount the area viewfinder.
(4)
1
Put the red string round the main unit.
Red string to hold the main unit
Center circle of the lens
2
Insert and mount to the main unit.
Area viewfi nder AVF-1 (optional)
Inspection window
Mounting tips>>
Engage the convex section of the area viewfi nder fi xing
• arms with the notches of the main unit, and insert and mount the arms.
Determine the
3
detection direction
(see Step 5-
Area plate (an accessory)
* Peel off the
protection seal from both faces of the area plate.
4
Insert the area plate into the slot.
1).
Fixing arms
3 Locate the center circle of the area
plate on the center circle of the lens of the area viewfi nder, and check the detection area pattern on the area plate and the background image. * Each letter on the area plate
corresponds to each mirror number (see Step 8-2).
* You cannot observe mirror
numbers B1 to F1 and B6 to F6 (shown at right) of the SIP-3020 area plate through the inspection window. Check them using the walk tester.
Invisible area
Center circle of the lens
Center circle of the area plate
The detection area is inside the frame border.
Adjusting tips>>
If you experience any of the following, see Step 10.
Limit line of
detection area The sensor area is extended over the street where a person walks or a car drives.
Branches of a tree and grass move when the wind blows.
Notch
Mount the area plate so that an arrow of the plate
• center section faces upward and the letter surface can be seen. Insert the area plate into the top and bottom grooves of
• the area viewfi nder until the plate is stopped by the ribs.
SIP-3020 SIP-4010
Arrow marking
Fine adjust the main unit angle in vertical and horizontal
(5)
SIP-3020CAM DN
Grooves
Ribs
SIP-404
direction by observing the target area through the area viewfinder.
1 To change the direction of the inspection
window, rotate the area viewfi nder in a horizontal direction until it clicks and stops.
2 Move your face close to the viewfi nder
so that your eye comes within 5 mm of the inspection window (lens surface).
4010 (521204)4010 (521204)
404 (521205)404 (521205)
Convex section
Cautions>>
The area viewfi nder is a supporting tool for detection area adjustment.
After you have adjusted the detection area using the area viewfi nder, always check the area using the walk tester.
Never look directly into the sun through the area view fi nder.
After you have used the area viewfi nder, store it away from direct sunlight.
(6)
Securely tighten the adjustment screw that you have loosened.
(7)
Connect the walk tester (optional) to the sensor unit, and check that the detection area is correct.
(OPM-WT) (AWT-3)
For near area
For far area
Use at “REDWALL” position.
Power selector switch
REDWAVE
REDWAVE
PIR NEAR
PIR FAR
REDWAVE
REDWAVE
MICROWAVE
ALARM OUTPUT
CELL BATTERY
REDWAVE
POWER SUPPLY FROM
SENSOR REDWALL REDWIDE
POWER OFF
MEGARED
REDWALL
MEGARED
REDWIDE
FAR
MEGARED
NEAR
CONNECTION
MODE
POWER
SELECT
SELECT
SELECT
SWITCH
SWITCH
SWITCH
WALKTESTER
OPM-WT
For all areas
For near area
For far area
Use at “REDWALL” position.
Power selector switch
- 4 -
1 When the power selector switch is turned to “POWER
SUPPLY FROM SENSOR” position after plugging the cable into the walk tester connector, a continuous beeping sound will be heard.
2 When a pedestrian first enters the detection area, the
strong and weak beeps will sound alternately.
3 When the entirety of a pedestrian’s body is detected, the
strong beep will sound continuously.
Cautions>>
When you are checking the detection area, take care not to cover the shaded area of the window with the walk tester or its cable. If infrared beams to the sensor are partially shielded, the detection sensitivity will drop and the detection operation may fail.
If it is diffi cult to detect an object>>
1. Set the detection logic switch to the “OR” position (see Step 5-2). If the sensor is OK when you have completed the walk test, return the logic switch to the “AND” position.
2. Adjust the sensor sensitivity switch (see Step 5-1).
To mask the detection area>>
Detection
area
Far area
Near area
5
FUNCTION SETTING
Applicable models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
How to mask the area Reference
Use the switch. 5-3 Use the masking plate (mounted
in the main unit). Use the masking plate (mounted
in the main unit). Attach the masking seal (an
accessory) to the area mirror surface.
Far area sensitivity selector switch
Walk tester
connector
Operation indicator
(See Step 11.)
Cautions>>
If the red LED keeps blinking for approx. 60 seconds after turning the power on, turn the power off and then on again.
5-1
Sensitivity Selector Switch for Near and Far Area
Applicable models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
You can change the sensitivity for far
Sens.Select.SW.Sens.Select.SW.
area detection and near area detection independently.
SELECTOR
POSITION
SH
H
M
(Factory
default)
L
Step 7
8-1
8-2
Near area sensitivity selector switch
Sens.Select.SW.Sens.Select.SW.
Far areaFar area Near areaNear area
1: Detection logic selector (AND or OR) 2: Detection range selector
3,4: Alarm holding time selectors
57307315730731
switch
UP DWN
Tamper switch
FUNCTION
Suitable for sites requiring a level of sensitivity higher than “H”
Suitable for sites requiring a level of sensitivity higher than “M”
Suitable for standard applications
Suitable for hostile and narrow area
- 5 -
5-2
Detection Logic Selector Switch
Applicable models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
The near area sensor has two dual-element devices, and it covers two types of plane areas alternately using the two devices.
SELECTOR
UP
POSITION
DWN
UP
STATUS
FUNCTION
A sensor signal is output when an object is detected in either of the two detection areas.
OR
Factory
* Use this mode when you adjust
( )
default
the detection area. Switch to AND mode after you have finished the
detection area adjustment. Use this mode to reduce instances of incorrect detection of objects. The sensor signal is output only when
DWN AND
an object is detected within the two detection areas. If any objects are blocking multiple detection areas, use OR mode.
5-3
Detection Range Selector Switch
SELECTOR
UP
POSITION
DWN
STATUS
UP OFF
FUNCTION
Cancels the far area detection. The detection area is reduced as shown below.
DWNONFactory
Applicable models
[m]
[ft.]
413
10
2
0
0
0102030 0 10 20 30 40 50 60 70 80 90 100 110 120 130[ft.]
Applicable models
[m]2[ft.]
413
10
00
0102030 0 10 20 30 40 50 60 70 80 90 100 110 120 130[ft.]
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
Enables the far area detection.
( )
default
Far area detection is canceled.
Far area detection is canceled.
Cautions>>
If you cancel the far area detection, the detection distance is limited to approximately 20 meters (65ft.). Be sure to readjust and check the detection area using the area viewfinder and the walk tester.
5-4
Alarm Interval Switch
Applicable models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
You can set an interval (4 different times) to suspend the alarm signal output. For example, if you set this interval to 30 seconds, no more alarm signals will be output for 30 seconds after the output of the first alarm signal. If no pedestrians are detected for more than 30 seconds, the system returns to the standby mode. Then, when a pedestrian is detected, the alarm signal will be output.
SELECTOR
POSITION
0 sec
FUNCTION
(Factory
15 sec 30 sec 60 sec
default)
Dip switch 1
Dip switch 2
40 [m]
40 [m]
Dip switch 3-4
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
6
DETECTION AREA
Applicable models
[m]
[ft.]
TOP VIEW
50
15
40
10
30
20
5
10
0
0
10
5
20
30
10
40
50
15
[m]
[ft.]
SIDE VIEW (Installation height 4.0 m (13ft.)) : Near area : Far area
413
10
2
0
0
0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
TOP VIEW (Installation height 2.3 m (7.6ft.))
[m]
[ft.]
15
50
40
10
30
20
5
10
0
0
10
5
20
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
(Installation height 4.0 m (13ft.))
40 [m]
Applicable models
TOP VIEW (Installation height 4.0 m (13ft.))
[m]
[ft.]
10
30
20
5
10
0
0
10
5
20
30
10
[m]2[ft.]
SIDE VIEW (Installation height 4.0 m (13ft.)) : Near area : Far area
413
10
00
0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
TOP VIEW (Installation height 2.3 m (7.6ft.))
[m]
[ft.]
10
30
20
5
10
0
0
10
5
20
30
10
SIDE VIEW (Installation height 2.3 m (7.6ft.)) : Near area : Far area
[m]
[ft.]
2.3
7.6
0
0
0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
40 [m]
40 [m]
30
10
40
15
50
[ft.]
[m]
SIDE VIEW (Installation height 2.3 m (7.6ft.)) : Near area : Far area
2.3
7.6
0
0
0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
40 [m]
Applicable models
TOP VIEW (Installation height 4.0 m (13ft.))
[m]
[ft.]
5
10
0
0
10
5
[m]2[ft.]
SIDE VIEW (Installation height 4.0 m (13ft.)) : Near area : Far area
413
10
00
0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
[m]
[ft.]
TOP VIEW (Installation height 2.3 m (7.6ft.))
5
10
0
0
10
5
[m]
[ft.]
SIDE VIEW (Installation height 2.3 m (7.6ft.)) : Near area : Far area
2,3
7,6
0
0
0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
40 [m]
40 [m]
- 6 -
Applicable models
TOP VIEW (Installation height 4.0 m (13ft.))
[m]
[ft.]
15
50
40
10
30
20
5
10
0
0
10
5
20
30
10
40
15
50
[m]
[ft.]
SIDE VIEW (Installation height 4.0 m (13ft.)) : Near area : Far area
413
10
2
0
0
0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
Angle of camera view: Approx. 60° (Factory default)
40 [m]
7
Masking the Far Area Sensor
The far area mirror mounted in the main unit has 2 far masking plates; one at the right side of this mirror and the other at the left side of this mirror. You can mask the detection area by changing the position of these masking plates.
Cautions>>
You can only mask the detection area from its outside to
• its inside using the masking plates. You cannot mask only the inside detection area. However, if you need to mask the inside detection area
• only, use the white space (margin) of the near area masking seal (an accessory) for the masking. Attach the seal and mask all mirrors that you need to shield.
Cautions>>
The window is linked to the main unit by nylon wire loop
• so that the window does not fall. Do not pull the window using excessive force. After you have masked the detection areas, mount the
• window and place the excessive nylon wire loop inside the main unit.
How to remove the window>>
Window
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
TOP VIEW (Installation height 2.3 m (7.6ft.))
[m]
[ft.]
50
15
40
10
30
20
5
10
0
0
10
5
20
30
10
40
50
15
SIDE VIEW (Installation height 2.3 m (7.6ft.)) : Near area : Far area
[m]
[ft.]
2.3
7.6
0
0
0102030
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [ft.]
Angle of camera view: Approx. 60° (Factory default)
40 [m]
Applicable models
1 Remove the masking plate from
15
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
the storage, and check the detection area and the mirror you use by referring to the area chart.
Far area mirror
Rib
34 12567
40
20
10 0 10
Press the left bottom hole with your nger, and pull the window up.
2 Attach the masking plate to the mirror,
and secure it to the ribs.
Rib
3 Insert the fi xing rubber form to secure
the knob of the masking plate.
20
50510
30 40
10 [m]
[ft.]30
5050 15
- 7 -
1
2
3
If tree branches or other moving objects are in the path of the detection beam.
5
4
7
6
8
MASKING THE NEAR AREA SENSOR
Applicable models
1 Remove the masking plate from the
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
storage, and check the detection area and the mirror you use by referring to the area chart.
Far area mirror
Rib
1234
SIP-4010 SIP-404
[ft.]10010
5
5
0
[m]
2 Attach the masking plate to the mirror,
and secure it to the ribs.
Rib
3 Insert the fi xing rubber form to secure
the knob of the masking plate.
[ft.]10 0 10 [m]505
8-1
Masking the Detection Areas using Masking Plates
The near area mirror mounted in the main unit has 2 near masking plates; one at the right side of this mirror and another at the left side of this mirror. You can mask the detection area by changing the position of these masking plates.
Cautions>>
You can mask the outside detection areas only; they are areas 1 and 6. Use the area masking seals (an accessory) to mask the other detection areas (see Step 8-2).
Applicable models
1 Remove the masking plate
from the storage, and check the detection area and the mirror you use by referring to the area chart.
Rib
664 2 5 3 1
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
2 Attach the masking plate to the mirror, and
secure it to the ribs.
3 Insert the fi xing rubber form to secure the
knob of the masking plate.
Rib
1
If tree branches or other moving objects are in the path of the detection beam.
432
2
Near area mirror
10 [m]155051015
3
1
2
3
If tree branches or other moving objects are in the path of the detection beam.
5
4
[ft.]30 20 10 0 10 20 30 40 5050 40
6
- 8 -
8-2
t
Masking the Detection Areas using Masking Seals
Using the tweezers (an accessory), carefully attach the area masking seals (an accessory) to the near area mirror.
Near area mirror
F 6
E 6
30 20 10 0 10 20 30 40
Area masking seals
MIRROR
642 53 1
F E
D C
B
F
F
F
642 53 1
E
E
E
D
D
D
642 53 1 642 53 1
C
C
C
642 53 1
B
B
B
50510
9
ADJUSTMENT OF CAMERA
9-1
Adjustment of Camera
Applicable models
(1)
135246
F
F
F
E
E
E
D
D
D C
C
C
B
B
B
[ft.]
5050 40
[m]10 1515
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
Open the camera cover, and connect the monitor unit cable to the camera unit.
1 Loosen the fi xing
screws.
2 Open the
camera cover.
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
F
E
D
C
B
1
2
3
[m]
.]
4
3 0
2
0
0
10 20 30 40 50 60 70 80 90 100 [ft.]
0
10 20 30
5
4
BCDEF
Points>>
If you are using the SIP-3020, SIP-4010, or SIP-404 sensor unit when you have completed Step 8, proceed to Step 9-2.
3 Connect the
monitor unit cable to the BNC terminal of camera
Caution>>
Peel off the protection seal(s) off the window.
unit.
Caution>>
Remove the transportation protection ardboard(s).
Adjust the vertical angle and the angle of view of the
(2)
camera.
6
[m]
1 Loosen the focal length
screw, and adjust the angle of view.
2 Loosen the focus screw, and
adjust the focus.
3 Adjust the angle by rotating
the vertical angle adjustment screw.
4 When you have completed these adjustments,
tighten screws 1 and 2.
Cautions>>
The vertical camera angle adjustment mechanism is separated from the detection area control mechanism. To satisfy the BS8418 Standard, make sure that the vertical angle and the angle of view of the camera match the detection area correctly.
(3)
Close the camera cover, and tighten two fixing screws.
Check the image viewed by the camera, using the monitor
(4)
unit or another monitoring device.
- 9 -
9-2
Termination Procedure
(1)
Applicable models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
After you have adjusted all sensor items, securely tighten all adjustment screws that you have loosened. Finally, securely tighten the bottom fixing screws.
2 Fixing screw
1 Adjustment screw
10
OPERATION TEST
10-1
If There is a Public Street Where a People Walk or Cars Drive by the Detection Area
Points>>
Reduce the size of the detection area so that it does not include any public streets.
Check to see that the arrow of the main unit is within the
(1)
width of “Angle adjustment guide” on the adjustment screw.
Using the area viewfinder, check to see that the detection
(2)
area does not include any public streets.
If the detection area does go beyond a public street,
(3)
correct the vertical angle of the main unit. However, exercise care so that the arrow does not move away significantly from the “Angle adjustment guide” position.
Cautions>>
If you need to adjust the detection area again, be sure
• to loosen the fi xing screw. If you try to move the main unit without loosening the fi xing screw, the unit may be damaged. When you mount the cover, place the excessive nylon
• wire loop in the main unit. If the wire has been pinched by the window and the cover, rain drops may be able to enter into the main unit.
(2)
Mount the cover.
If the arrow does move away signi cantly from
the “Angle adjustment guide” position:
Mask the far area detection area using the masking plate or by using the far area masking switch. You may be required to also mask the near area detection area under specific sensor installation conditions (see Steps 5 and 8).
When a person walks along the street or a car drives along
(4)
it, check the detection area using the walk tester.
Points>>
You cannot mount and use both the area viewfinder and walk tester simultaneously.
Cautions>>
The detection area may increase if there is a large difference in temperature between the moving object and the background.
- 10 -
Cautions>>
A heat source beyond the detection area may cause a false alarm due to the reflection of heat off the ground. Examples of types of surfaces that reflect include water (puddles), wet roads, smooth concrete surfaces and asphalt roads. If the source of the heat is strong and/or the reflection rate is high, the detection distance will be longer than required and may detect unnecessary objects beyond the target area. Therefore, select the detection range position according to the ground conditions of the installation site.
10-2
If Tree Branches or Grass are Detected When They Move Within the Detection Area
Points>>
Adjust the detection area so that it does not cover tree branches or grass that move when the wind blows.
Check to see that the arrow of the main unit is within the
(1)
width of “Angle adjustment guide” on the adjustment screw.
Using the area viewfinder, check to see that the detection
(2)
area does not cover tree branches or grass that may move when the wind blows.
Use the walk tester to listen for sound level changes when
(3)
there is no apparent activity in the detection area. Adjust the detection area so that it does not detect unwanted areas.
If the sound level changes, some part of the detection area must be active (i.e.: an object is moving).
Use the walk tester and locate the part of the detection area
(4)
that is active. Change the walk tester selector switch position and determine whether the active part of the detection area is far or near.
12
SPECIFICATIONS
12-1
Specifi cations of the Main Unit
Applicable models
Detection method Passive infrared
Number of detection
Mounting height 2.3 to 4m (7.6 to 13ft.)
Operation indicator RED ALARM
Warm-up period Approx. 60 sec.
Detection range
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
Model SIP-3020 SIP-4010 SIP-404
Coverage
zones
Power input
With optional
heating unit
Current draw
With optional
heating unit
selector
30 x 20m
(100 x 65ft.)
74 zones 48 zones 24 zones 74 zones
410mA max. (24V AC)
40 x 10m
(130 x 33ft.)
11 - 16V DC 22 - 26V AC
22 - 26V AC
35mA max. (12V DC) 70mA max. (24V AC)
Far area: ON / OFF
40 x 4m
(130 x 13ft.)
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
SIP-3020
CAM DN
30 x 20m
(100 x 65ft.)
12V DC
Can not use
SIP-HU
180mA max.
(12V DC)
Using the area viewfinder again, locate the active detection
(5)
area.
Mask the active detection area. To do this, mask the area
(6)
using the masking plate or the masking seal. Otherwise mask the area using the far area masking switch (see Steps 5, 7, and 8).
Using the walk tester again, check that the sound level
(7)
changes. If the sound level does not change excessively, you can finish the adjustment.
Points>>
You cannot mount and use both the area viewfinder and the walk tester simultaneously.
11
LED FUNCTIONS
Alarm interval period
Detection logic
selector
Tamper output N.C. 28V DC, 0.1A max.
Trouble output N.C. 28V DC, 0.2A max.
Alarm output
Sensitivity selector Far: SH/H/M/L Near: SH/H/M/L
Operating temperature
IP rating
Dimensions (H × W × D)
Weight 1.2kg (42 oz.)
Accessories
-25 to +60°C, -40 to +60°C with optional heating unit (-13 to +140°F, -40 to +140°F with optional heating unit)
Screws, paper template, allen key, area masking seal, tweezers, instruction manual, area plate, fixing rubber form
0 / 15 / 30 / 60 sec.
AND/OR
N.C.28V DC, 0.2A max. N.O.28V DC, 0.2A max.
Main unit: IP65 Chassis :IP55
227 x 102 x 266mm (9.0 x 4.0 x 10.5 in.)
252 x 102 x 317 mm (9.9 x 4.0 x 12.5 in.)
1.5kg (52 oz.)
Cautions>>
If the red LED keeps blinking for approx. 60 seconds after turning
Far areaFar area
Operation indicator - Red LED
DETECTOR STATUS If the cover is removed
During power ON Blinks.
During standby Turns OFF.
When detected (in far/near area) Lights.
the power on, turn the power off and then on again.
- 11 -
12-2
Camera Specifi cations
Applicable models
SIP-3020 SIP-4010 SIP-404 SIP-3020CAM DN
SIP-3020CAM
102
(4.0)
317
(12.5)
Model
SIP-3020CAM DN (EU) SIP-3020CAM DN (US)
Image sensor 1/3" CCD (PAL) 1/3" CCD (NTSC)
TV line 480TVL (at wide position)
Resolution PAL
752 H x 582 V
Lens
f = 3 to 9mm, varifocal, DC auto iris lens F1.2
NTSC
768 H x 494 V
Minimum illumination Day (colour): 0.5 lx (F1.2)
Night (B/W): 0.03 lx (F1.2)
Video output
1.0Vp-p/75
/BNC connector, PAL
Close.
Open.
1.0Vp-p/75 /BNC connector, NTSC
Iris
90
(3.6)
21
(0.83)
96
(3.78)
216
(8.5)
21
(0.83)
17.1
(0.67)
75
(3.0)
Unit:mm (inch)
252
(9.9)
13
116
(0.51)
(4.57)
DIP switch
No.
1 ELC/ALC Exposure control
2 AGC Automatic sensitivity
3 BLC Backlight correction ON
4 * Leave this switch OFF (factory default).
DIMENSION
SIP-3020/4010/404
102
(4.0)
90
(3.6)
NAME Function Factory default
setting
OFF (ALC)
method setting
ON
setting
266
(10.5)
227
(9.0)
96
(3.78)
21
(0.83)
21
(0.83)
75
17.1
(0.67)13(0.51)
(3.0)
Unit:mm (inch)
116
(4.57)
OPTION
OPM-WT, AWT-3 -Audio Walk Tester
AVF-1 -Area View Finder
SIP-MINIHOOD -Sun/Snow shield
SIP-HU -Heating unit
Cautions>>
When SIP-HU is used, the power for SIP unit should be 22 - 26V AC. SIP-3020CAM DN can not use SIP-HU.
These units are designed to detect movement to activate CCTV system. Being only part of a complete surveillance system, we cannot accept responsibility for any damage or other consequences resulting form the activation of the unit. This product confirms the EMC Directive 2004/108/EC.
Specifications and design are subject to change without prior notice.
OPTEX CO., LTD. (JAPAN)
(ISO 9001 Certifi ed) (ISO 14001 Certifi ed)
5-8-12 Ogoto Otsu Shiga 520-0101 JAPAN TEL:+81-77-579-8670 FAX:+81-77-579-8190 URL:http://www.optex.co.jp/e/
OPTEX INCORPORATED (USA)
TEL:+1-909-993-5770 Tech:(800)966-7839 URL:http://www.optexamerica.com/
OPTEX (EUROPE) LTD. (UK)
TEL:+44-1628-631000 URL:http://www.optexeurope.com/
- 12 -
OPTEX SECURITY SAS (FRANCE)
TEL:+33-437-55-50-50 URL:http://www.optex-security.com/
OPTEX SECURITY Sp. z o. o. (POLAND)
TEL:+48-22-598-06-55 URL:http://www.optex.com.pl/
Loading...