Onkyo SKW 30 Service Manual

SKW-30-BUL-1
11/22/01
SKW-30
Symptom:
Solution:
detached from the main PCB solder terminal. The voltage through R16 may not arrive at its intended target should this happen causing unit not to operate. Make a jumper wire from one end of R16 as seen to the block solder terminal VCC point.
Warning:
source and discharge power supply capacitors very slowly. Do not introduce instant discharge of the power supply filter capacitors, as it would harm the power block.
No power at all
When performing this procedure one must make sure unit is not plugged to the any power
Solder at point A VCC input may crack or come loose. Add wire as indicated to stabilize trace from Power block VCC leading up to R16 solder end as seen.
Loading...