STANDBY/ON
PHONES
SERVICE MANUAL
CD RECEIVER
MODEL CR-305TX
MEMORY FM MODE
CLEAR
DISPLAY
INPUT
TUNING/PRESET
U
M
L
O
E
V
M
I
N
M
CR-305TX
Ref. No. 3723
062002
REMOTE CONTROLLER
STANDBY/ON
TIMER ENTER
RANDOM
MEMORY REPEAT
SCROLL
PLAY MODE
SLEEP
CLOCK
CALL
E
E
C
C
N
N
E
E
S
S
E
E
R
R
P
P
C
C
I
I
T
T
S
S
U
U
O
O
C
C
A
A
X
A
PLAY MODE
TUNER
PRESET
REPEAT
O
V
VOLUME
V
O
L
REPEAT
RC-421S
INPUT
CD
MD
M
E
U
A.PRESENCE
L
U
P
MUTING
N
W
U
O
M
D
E
CDR
TAPE
Silver model
UDD,UDT
UGT,UGR,
UPP
120V AC, 60Hz
220-230V AC, 50Hz
230-240V AC, 50Hz
SAFETY-RELATED COMPONENT
WARNING!!
COMPONENTS IDENTIFIED BY MARK ON THE
SCHEMATIC DIAGRAM AND IN THE PARTS LIST ARE
CRITICAL FOR RISK OF FIRE AND ELECTRIC SHOCK.
REPLACE THESE COMPONENTS WITH ONKYO
PARTS WHOSE PART NUMBERS APPEAR AS SHOWN
IN THIS MANUAL.
MAKE LEAKAGE-CURRENT OR RESISTANCE
MEASUREMENTS TO DETERMINE THAT EXPOSED
PARTS ARE ACCEPTABLY INSULATED FROM THE
SUPPLY CIRCUIT BEFORE RETURNING THE
APPLIANCE TO THE CUSTOMER.
RC-421S
SERVICE PROCEDURES-1
PROTECTION OF EYES FROM LASER BEAM DURING SERVICING
CR-305TX
This set employs a laser. Therefore, be sure to follow
carefully the instructions below when servicing.
WARNING!!
SERVICE WARNING : DO NOT APPROACH THE
LASER EXIT WITH THE EYE TOO CLOSELY.
IN CASE IT IS NECESSARY TO CONFIRM LASER
BEAM EMISSION, BE SURE TO OBSERVE FROM
A DISTANCE OF MORE THAN 30cm FROM THE
SURFACE OF THE OBJECTIVE LENS ON THE
OPTICAL PICKUP BLOCK.
LASER W ARNING LABEL
The labels shown below are affixed.
1. Warning label
2. Class 1 label
LUOKAN 1
"CLASS 1 LASER
PRODUCT"
LASERLAITE
KLASS 1
LASER APPARAT
Laser Diode Properties
Material: GaAS/GaAlAs
Wavelength: 780nm
Laser output: max. 0.5mW*
Emission Duration: continuous
*This output is the value measured at a distance about 1.8mm
from the objective lens surface on the Optical Pickup Block.
DANGER:
INVISIBLE LASER RADIATION WHEN OPEN AND
INTERLOCK FAILED OR DEFEATED. AVOID DIRECT
EXPOSURE TO BEAM.
CAUTION:
HAZARDOUS LASER AND ELECTROMAGNETIC
RADIATION WHEN OPEN AND INTERLOCK DEFEATED.
ATTENTION:
RAYONNEMENT LASER ET ELECTROMAGNETIQUE
DANGEREUX SI OUVERT AVEC L'ECLENCHEMENT
DE SECURITE ANNULE.
Printed on rear panel
SERVICE PROCEDURES-2
SERVICE PROCEDURES
1. Replacing the fuses
This symbol located near the fuse indicates that the
fuse used is show operating type, For continued protection against
fire hazard, replace with same type fuse , For fuse rating, refer to
the marking adjest to the symbol.
Ce symbole indique que le fusible utilise est e lent.
Pour une protection permanente, n'utiliser que des fusibles de meme
type. Ce demier est indique la qu le present symbol est apposre.
CR-305TX
REF.NO.
F901
PART NO.
252157
252083
DESCRIPTION
1.25A-UL/T-237, Fuse <DD, DT>
0.4A-SE-EAW, FUSE <PP,GR, GT>
NOTE : <DD, DT> : 120 V model only
<PP,GR, GT> : 230 V model only
2. To initialize the unit
1. Press and hold the MEMORY button and press the DISPLAY button.
All segments light up.
2. Press the STANDBY/ON button.
When " CLEAR " appears on the display, the preset memory and each mode stored in the memory are initialized
and will return to the factory setting.
3. Safety-check out
(Only U.S.A. model)
After correcting the original service problem perform the follwing safety check before releasing the set to the customer
Connect the insulating-resistance tester between the plug of power supply cord and terminal GND on the back panel.
Specifications: More than 10Mohm at 500V
4. Memory Preservation
This unit does not require memory preservation batteries. A built-in memory power back-up system preserves the contents of
the memory during power failures and even when the unit is un-plugged.
The unit must be plugged in order to charge the back-up system.
The memory preservation period after the unit has been unplugged varies depending on climate and placement of the unit.
On the average, memory contents are protected over a period of a few weeks after the last time the unit has been unplugged.
This period is shorter when the unit is exposed to a highly humid cli-mate.
5. Changing the AM band step
With the exception of the worldwide models, a tuning step selector switch is not provided.
When you change the band step, change the parts as shown below.
To 10kHz To 9kHz
R705 3.3k 10k
R706 5.6k open
CR-305TX
P ANEL VIEW
REAR PANEL
Do not connect the AC power cord (mains lead) to the wall outlet (the mains) until you have completed all the other connections
including the connections on page 7, and the speaker connections on page 8.
On each pair of connectors, a red connector (marked R) corresponds to the right channel, and a white connector (marked L)
to the left channel.
Connect white plugs of audio connection cables to L connectors and connect red plugs of audio connection cables to R connectors .
Audio connection cable
OUT
(
)
REC
)
PLAY
IN
OUT
)
REC
)
PLAY
IN
(White)
(Red)
ANTENNA
L
R
RL
To L connector
To R connector
FM
75
AM
DIGITAL
OPTICAL
OUTPUT
SUBWOOFER
PRE OUT
Improper connection
Insert completely
SPEAKERS
RL
To L connector
To R connector
(White)
(Red)
Please refer to the instruction manual for each component when you make
any connections.
Insert the plug securely. If the connection is incomplete, noise or malfunction may result.
U.S. and Canadian models
REMOTE
CONTROL
Stereo cassette
tape deck
CD recorder
INPUT (REC)
OUTPUT (PLAY)
INPUT (REC)
OUTPUT (PLAY)
TAPE
CDR
(
(
(
DIGITAL OPTICAL NPUT
Asian and European models
Stereo cassette
tape deck
CD recorder
Protective cap for the optical digital audio connector
Remove the protective cap before you use
the OPTICAL DIGITAL OUTPUT connector.
Please retain it for future use. If
you do not use the optical digital audio
connector, make sure to replace the cap.
INPUT (REC)
OUTPUT (PLAY)
INPUT (REC)
OUTPUT (PLAY)
DIGITAL OPTICAL NPUT
DIGITAL OPTICAL
INPUT
: Signal flow
REMOTE
CONTROL
TAPE
OUT
(
REC
(
PLAY
IN
OUT
(
REC
(
PLAY
IN
CDR MD
ANTENNA
R
)
)
)
)
RL
FM
75
L
OPT I CAL
OUT
(
)
REC
(
)
PLAY
IN
RL
OUTPUT
(PLAY)
MD recorder
AM
DIGITAL
OUTPUT
SPEAKERS
RL
INPUT
(REC)
: Signal flow
To wall outlet
To wall outlet
EXPLODED VIEW PARTS LIST-1
CR-305TX
REF NO. PART NO. DESCRIPTION
1
6
7
8
9
10
12
14
15
16
20
22
23
24
25
26
31
33
41
42
43
44
46
47
50
52
53
54
3217210171000
838130088
3200210996000
27190693A
27191112
4070210311000
27175253-1A
27300750
830440069
831430088
4310210401000
3000210266000
838930088
5087210571000
4317210391000
27150456
3207211006000
3207211006100
838430068
3067210858000
3067210858011
5127210262000
4357210031000
5070210851000
3710210333000
5077210843000
880009
5507100500450
5507100500470
5507100500480
5507100500460
5507100500510
5507100500520
5507100500440
FRAME FRONT
3TTB+8B, Self tapping screw
MAIN CHASSIS
KGLS-6RF, Holder
KGPS-6RF, Holder
SUPPORTER CD MECHA
Leg
Busing, cord
4TTC+6C(BC), Self tapping screw
3TTW+8B(BC), Self tapping screw
COVER HEAT SINK
CABINET COVER
3TTB+8B(UN), Self tapping screw
KNOB VOLUME
DOOR CD
Shield plate
BACK CHASSIS
BACK CHASSIS
3TTB+6B(BC), Self tapping screw
AL PANEL FRONT
AL PANEL FRONT
DECORATION VOLUME
GUIDE VOLUME
WINDOW REMOCON
LENS INDICATOR
WINDOW DISPLAY
Plastic rivet, NRP-345
LABEL RATING
LABEL RATING
LABEL RATING
LABEL RATING
LABEL FCC and WARNING
LABEL FCC and WARNING
LABEL LASER CAUTION
<DD>
<PP, GR, DT, GT>
<DD, GR, DT, GT>
<PP>
<PP, GR, GT>
<DD>
<GR>
<DT>
<PP>
<DD>
<PP, GT, DT>
<GR, GT, PP>
REF NO. PART NO. DESCRIPTION
F901
P302
P303
P351
P352
P701
P778
P901
Q557,Q558
Q559,Q560
Q557A
Q557B
T901
Z1
Z2
Z3
Z5
Z6
CAUTION:
Replacement of the transistor of mark , if necessary, must be made
from the same beta group(HFE) as the original type.
252157
252083
2009990500
20022391210
2047161012
2042161022
2047360612
2047151012
253294HDK
253287HIT
253237HIT
2203384 or
2203383
2203394 or
2203393
2120210418000
801433
2301452
2301454
2301453
24800018A
24840133
24840135
838120080
838426088
1.25A-UL/T-237, Fuse
0.4A-SE-EAW, Fuse
NSAS-10P0654, Socket
NSAS-12P0723, Socket
NCFC7-161012, Flexible flat cable
NCFC2-161022, Flexible flat cable
NCFC7-360612, Flexible flat cable
NCFC7-151012, Flexible flat cable
AS-UC-2#18, Power supply cord
AS-CCEE, Power supply cord
AS-CEE, Power supply cord
2SC3851-Y or
2SC3851-O, Transistor
2SA1488-Y or
2SA1488-O, Transistor
HEAT SINK
3SMS8W.SW+14B(BC), Special screw
NPT-1391D, Power transformer
NPT-1391G, Power transformer
NPT-1391P, Power transformer
NCD-170S, CD mechanism
Boss, PCB
Boss, PCB3
2TTB+8P, Self tapping screw
2.6TTB+8B(BC), Self tapping screw
<DD, DT>
<PP,GR, GT>
<DD, DT>
<GR>
<PP, GT>
<DD, DT>
<GR, GT>
<PP>
NOTE: THE COMPONENTS IDENTIFIED BY MARK ARE
CRITICAL FOR RISK OF FIRE AND ELECTRIC SHOCK.
REPLACE ONLY WITH PART NUMBER SPECIFIED.
NOTE:
<DD> : USA and Canadian model only
<PP> : European model only
<DT> : Taiwanese model only
<GT> : Asian model only
<GR> : Chinese model only
CR-305TX