Onkyo A-9010 Service Manual

INTEGRA TED AMPLIFIER
MODEL A-9010(B)/(S)
8.PRGHOV
A-9010
Ref. No. 4516
032015
042015(WMB)
Black and Silver models
B WMP B WMB S WMP B WDC S WJJ
220-240V AC, 50/60Hz
120V AC, 60Hz 100V AC, 50/60Hz
RC-902S
SERVICE PROCEDURE
INITIAL SETTING FOR SHIPPING
Initialization of memories. Hold down [DIRECT button and then press [ON/STANDBY] button. Unplug the power cord after it goes standby mode.
A-9010
ADJUSTMENT PROCEDURE
Idling Current
When
1. Exchange the transistor (Q308-Q310, Q315, Q316, Q408-Q410, Q415, Q416).
2. Exchange the Main PC board.
3. Exchange the Power transformer (main).
Setting position
BASS, TREBLE and BALANCE: Center. VOLUME: Minimum.
Procedure
a. Pre-adjustment
Set the following registers to minimum position before POWER ON. Set the voltages at the following terminals to the following voltage by adjusting the following registers, under the condition of no input and no load, immediately after POWER ON.
Channel Terminals Registers Voltage
b. Aging
Heat run during the following time.
Time 4 - 6 minutes
L CN04 VR41 8 mV
R CN03 VR31 8 mV
A-9010
c. Final adjustment
Re-adjust by the following procedure after heat running for the above mentioned time.
L / R Below Between Over
7.5 mV 8 mV(+0.5 / -0.5 mV)
8.5 mV
7.5 mV Do not adjust.
8.5 mV
Adjustment point / Test terminal
VR31
CN03
VR41
CN04
Front
Connection
DC Voltmeter
CN03, CN04
Main PC board
A-9010
A
EXPLODED VIEW - 1/2
(B): Black
1
2
BCDE
Q315, Q308, Q316, D901, Q415, Q408, Q416
FUSE
LABEL , HOT
3
A-9010
4