Enclosed Switches ZE/ZV/XE/XV F-121
Limit
Switches
■ Ratings
Note: 1. The above figures are for standard currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
■ Characteristics
Note: 1. The above figures are initial values.
2. IP65 for @E-N models and IP60 for @E-Q models.
3. The values are calculated at an operating temperature of 5°C to 35°C, and an operating humidity of 40% to 70%. Contact your OMRON
sales representative for more detailed information on other operating environments.
4. At the operation limit positions.
5. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm lever.
6. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and sealed roller plunger.
Contact Contact Rated voltage Non-inductive load Inductive load
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
ZE-@
ZV-@
ZV2-@
125 VAC 15 A 3 A 1.5 A 15 A 5 A 2.5 A
250 VAC 15 A 2.5 A 1.25 A 15 A 3 A 1.5 A
480 VAC 10 A 1.5 A 0.75 A 6 A 1.5 A 0.75 A
125 VDC 0.5 A 0.5 A 0.05 A 0.05 A
250 VDC 0.25 A 0.25 A 0.03 A 0.03 A
XE-@
XV-@
XV2-@
8 VDC 15 A 3 A 3 A 15 A 15 A 10 A 10 A
14 VDC 15 A 3 A 3 A 15 A 10 A 10 A 10 A
30 VDC 15 A 3 A 3 A 10 A 10 A 10 A 6 A
125 VDC 10 A 3 A 1.5 A 7.5 A 6 A 6 A 4 A
250 VDC 3 A 1.5 A 0.75 A 2 A 1.5 A 2 A 1 A
Inrush current NC 30 A max.
NO 15 A max.
Degree of protection IP65 (see note 2)
Durability (see note 3) Mechanical:
Z@: 10,000,000 operations min.
X@: 1,000,000 operations min.
Electrical:
Z@: 500,000 operations min., for 15 A, 250 VAC resistive load
X@: 100,000 operations min., for 10 A, 125 VDC resistive load
Operating speed Plunger type: 0.01 mm to 0.5 m/s
Lever type: 0.02 mm to 0.5 m/s
Operating frequency Mechanical: 120 operations/min
Electrical: 20 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 15 mΩ max. (initial value)
Terminal temperature rise 50° max.
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal part and ground, and between each
terminal and non-current-carrying metal part (1,500 VAC for Z@ models and X@ models)
Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (see note 4)
Shock resistance (see note 4)
Destruction: 1,000 m/s
2
min.
Malfunction: 100 m/s
2
min. (see note 5), 50 m/s2 min. (see note 6)
Ambient temperature (see note 1) Operating: –10°C to 80°C (with no icing)
Ambient humidity Operating: General-purpose type: 85% max.
Sealed type: 95% max.
Weight Approx. 260 to 280 g