The scalable high-precision laser measurement sensor
ZS-HL series
The ZS laser sensor family provides outstanding measurement performance on
all kind of materials. Its huge range of
sensor heads and scalable concept
makes it a versatile platform for all high
precision sensing applications.
• Highest resolution and dynamic
sensing range for all surfaces
• Modular and scalable platform
concept for up to 9 sensors
• Easy to use, install and maintain for all
user levels
• Fast response time of 110 µs
• Multi-tasking capability – manages up
to 4 measurement tools in one
controller
This is the peak-to-peak displacement conversion value in the displacement output at the measuring center distance in high-precision mode when the number of
samples to average is set to 128 and the measuring mode is set to the high-resolution mode. The standard workpiece is white aluminum ceramics in diffuse reflection mode and glass in the regular reflection mode.
20±1 mm
40±2.5 mmLine beam 2000x35 µmZS-LD40T
50±5 mm
80±15 mmLine beam900x60 µm2 µmZS-LD80
130±15 mm Line beam600x70 µm3 µmZS-LD130
200 ±50 mmLine beam900x100 µm5 µmZS-LD200
350 ±135 mm Spot beam240 µm dia.20 µmZS-LD350S
Sampling cycle110 µs (high-speed mode), 500 µs (standard mode), 2.2 ms (high-precision mode), 4.4 ms (high-sensitivity mode)
Indica-
NEAR
tors
indicator
FAR
indicator
Operating
ambient
illumination
Ambient
temperature
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Degree of
protection
Vibration
resistance
(destructive)
Shock resistance
(destructive)
MaterialsCase: aluminum die-cast, front cover: glass
Cable length0.5 m, 2 m2 m0.5 m, 2 m
WeightApprox. 350 gApprox. 600 gApprox. 800 g
F.S.: Full scale of measurement
*1.
Defined as 1/e² (13.5%) of the center optical intensity in the measurement center distance. The beam diameter is sometimes influenced by the ambient conditions
of the workpiece such as leaked light from the main beam.
*2.
This is the error on the measured value with respect to an ideal straight line. Linear curve may change according to the workpiece. The following lists the workpieces
ModelDiffusive reflectionMirror reflection
ZS-HLDS2TSUS blockGlass
ZS-HLDS5T/HLDS10White alumina ceramicGlass
ZS-HLDS60/HLDS150White alumina ceramic-
ZS-HLDS2VT-Glass
*3.
This is the “peak-to-peak” displacement conversion value of the displacement output in the measurement center distance when high-resolution mode and the average number in the table are set (For ZS-HLDS60, the maximum resolution at 250 mm is also included). The following lists the workpieces.
ModelDiffusive reflectionMirror reflection
ZS-HLDS2TSUS blockGlass
ZS-HLDS5TWhite alumina ceramicGlass
ZS-HLDS10White alumina ceramic
ZS-HLDS60/HLDS150White alumina ceramic-
ZS-HLDS2VT-Glass
*4.
Value obtained when the sensor part and object part are fixed with an aluminum jig.
Lits near the measurement center, and nearer than the measurement center distance inside the measuring range.
Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient.
Lits near the measurement center, and further than the measurement center distance inside the measuring range.
Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient.
Illumination on received light surface 3,000 lx or less (incandescent light)Illumination
on received
light surface
1,000 lx or
less (incandescent light)
Operating: 0 to +50°C, storage: -15 to +60°C (with no icing or condensation)
Measuring range ±1 mm±1 mm±1 mm±1 mm±2.5 mm±2 mm±0.5 mm±0.75 mm
Light sourceVisible semiconductor laser (wavelength: 650 nm, 1 mW max., JIS Class 2)
Beam shapeLine beamSpot beamLine beam
Beam diameter
*2
Linearity
Resolution
Temperature
characteristic
Sampling cycle
Indica-
NEAR
tors
indicator
FAR
indicator
Operating ambient illumination
Ambient
temperature
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Degree of
protection
MaterialsCase: Aluminum die-cast, front cover: Glass
Cable length0.5 m, 2 m
WeightApprox. 350 gApprox. 400 g
AccessoriesLaser labels (1 each for JIS/EN, 3 for FDA), ferrite cores (2), insure Locks (2), instruction sheetLaser safety labels (1 each for JIS/
*1.
Defined as 1/e² (13.5%) of the center optical intensity at the actual measurement center distance (effective value). The beam diameter is sometimes influenced by
the ambient conditions of the workpiece, such as leaked light from the main beam.
*2.
This is the error in the measured value with respect to an ideal straight line. The standard workpiece is white aluminum ceramics in diffuse reflection mode and
glass in the regular reflection mode of the ZS-LD20T/40T/50. Linearity may change according to the workpiece.
*3.
This is the peak-to-peak displacement conversion value in the displacement output at the measuring center distance in high-precision mode when the number of
samples to average is set to 128 and the measuring mode is set to the high-resolution mode. The standard workpiece is white aluminum ceramics in diffuse reflection mode and glass in the regular reflection mode.
*4.
This is the value obtained at the measuring center distance when the Sensor and workpiece are fixed by an aluminum jig.
*5.
This value is obtained when the measuring mode is set to the high-speed mode.
ZS-HLDC/LDC series
reflection
Diffuse
reflection
Regular
reflection
Diffuse
reflection
Regular
reflection
Diffuse
reflection
Regular reflection
20 mm6.3 mm20 mm6.3 mm40 mm30 mm10 mm15 mm
*1
900x25 µm25 µm dia.2,000x35 µmApprox. 25x900 µm
±0.1%F.S
*3
0.25 µm0.25 µm0.4 µm0.25 µm0.25 µm
0.04% FS/°C0.04% FS/°C0.02% FS/°C0.04% FS/°C
*4
*5
110 µs (high-speed mode), 500 µs (standard mode), 2.2 ms (high-precision mode), 4.4 ms (high-sensitivity mode)
Lights near the measuring center distance, and nearer than the measuring center distance inside the measuring range.
Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient.
Lights near the measuring center distance, and further than the measuring center distance inside the measuring range.
Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient.
Illumination on received light surface: 3,000 lx or less (incandescent light)
Operating: 0 to 50°C, storage: -15 to 60°C (with no icing or condensation)
110 µs (high-speed mode), 500 µs (standard mode), 2.2 ms (high-precision mode), 4.4 ms (high-sensitivity mode)
Lights near the measuring center distance, and nearer than the measuring center distance inside the measuring range.
Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient.
F.S.
±0.1%F.S. ±0.25%
Lights near the measuring center distance, and further than the measuring center distance inside the measuring range.
Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient.
Illumination on received light surface: 3,000 lx or less (incandescent light)Illumination on received
light surface: 2,000 lx or
Illumination on received light surface:
3,000 lx or less (incandescent light)
less (incandescent light)
Operating: 0 to 50°C, storage: -15 to 60°C (with no icing or condensation)
F.S.
dia.
±0.04%
F.S.
FS/°C
Ambient humidity Operating and storage: 35% to 85% (with no condensation)