Omron WT30-M01-FLK, WT30-SID16, WT30-SMD16, WT30-SMD16-1 Specification Sheet

Page 1
FA Wireless SS Terminals WT30 1
FA Wireless SS Terminals
WT30
Construct a Wireless System for ON/OFF Data Collection That Is Ideal for Monitoring Production Site Equipment
• Wireless Slave Station equipped with I/O.
• Easily check wireless communications status from indicator display.
• I/O Slave Stations can also be used as Slave Stations in WD30 systems.
• Conforms to radio wave standards for Japan, China (pending), USA, and Europe.
Ordering Information
List of Models
Note: An Antenna and Mounting Brackets are not included with the Wireless SS Terminal.
Accessories
Antennas
Communications Cables
Other
Applicable Standards
FCC part 15.247 (USA)
EN 300 440-2 (Europe)
ARIB STD-T66 (Japan)
(China) (approval pending)
Main Class 2 Power Supplies
OMRON Switching Power Supplies
S8VS (15 W, 30 W, 60 W type)
S82K (15 W, 30 W, 50 W, 90 W type)
Applicable Countries
Wireless standards have been met for the following countries. The product cannot be used in any other countries.
Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungry, Iceland, Ireland, Italy, Japan, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland, UK, USA
Wireless Unit model Type Specifications/No. of I/O points
WT30-M01-FLK Serial master RS-232C
WT30-SID16 I/O slaves 16 DC inputs (NPN/PNP)
WT30-SMD16 8 DC inputs (NPN/PNP) + 8 transistor outputs (NPN)
WT30-SMD16-1 8 DC inputs (NPN/PNP) + 8 transistor outputs (PNP)
Model Type
WT30-AT001 Magnet-base Antenna (2 antennas per set)
WT30-AT002 Flat Diversity Antenna (1 antenna)
WT30-AT003 Pencil Antenna (2 antennas per set)
Model Length Application
XW2Z-0100U-3 1 m For personal computer
XW2Z-0200U-3 2 m
XW2Z-0500U-3 5 m
XW2Z-0200U-5 2 m Cross cable for PLC
XW2Z-0500U-5 5 m
Model Type
WT30-FT001 DIN Rail Mounting Bracket (for TH35-7.5)
WT30-FT002 DIN Rail Mounting Bracket (for TH35-15)
WT30-FT003 Surface Mounting Bracket (screw-mounting)
(2 brackets per set)
WT30-FT011 Flat Diversity Antenna Mounting Brackets
(with magnets)
WT30-CA2M Antenna Extension Cable (1 cable, 2 m)
Conformity to Safety Standards
Always use a Class 2 power supply to conform to UL standards.
Conformity to EN Standards
Use a DC power line less than 3 m to conform to EN standards. If a power line of 3 m or longer is required, extend the length at the Switching Power Supply’s primary side (i.e., the AC power line).
Page 2
2 FA Wireless SS Terminals WT30
Specifications
Ratings
Note: 1. Provide a power supply of at least 15 W, considering the inrush current generated at startup.
2. Use the WT30-FT003 Surface Mounting Bracket when installing the WT30 in environments subject to vibration.
Wireless Interface Specifications
Note: Varies according to the installation environment.
Package Contents
WT30 FA Wireless SS Terminal • Terminal labels (I/O Slaves only)
Instruction Sheet Adhesive non-slip feet (Serial Master only)
Item WT30-M01-FLK Serial Master WT30-SID16/SMD16/SMD16-1 I/O Slaves
Power supply (wireless communications power supply)
Rated voltage 24 V DC
Allowable voltage range
20.4 to 26.4 V DC
Power consumption 3 W max. (See note 1.)
Error output/output power supply (for output circuits)
Rated voltage --- 24 V DC
Allowable voltage range
--- 20.4 to 26.4 V DC
Insulation resistance 20 M
min. (at 100 V DC) between the power
supply and chassis
20 M min. (at 100 V DC) between the power supply and all I/O and I/O power supply and between the power supply and chassis
Dielectric strength 1,500 V AC for 1 min between power supply
and chassis
1,500 V AC for 1 min between the power supply and all I/O and I/O power supply and between the power supply and chassis
Noise immunity IEC61000-4-4. 1 kV (power supply line)
Vibration resistance (See note 2.) JIS C0040
Frequency: 10 to 55 Hz; Amplitude of 0.35 mm or acceleration of 50 m/s
2
, whichever is smaller
(DIN Rail mounting: single amplitude of 0.1 mm or acceleration of 15 m/s
2
)
10 sweeps of 8 min each (i.e., 80 min in total) in X, Y, Z directions
Shock resistance
Conforms to JIS C0041: 300 m/s
2
3 times each in X, Y, and Z directions
Ambient operating temperature
10 to 55°C (with no condensation or icing)
(with the Terminal mounted with the dust-proof label facing up)
Number of simultaneously ON I/O points 10 max.:
10 to 55°C (with no condensation or
icing) 16 max.:
10 to 50°C (with no condensation or
icing) (with the Terminal mounted with the dust-proof label facing up)
Ambient operating humidity 25% to 85% (with no condensation or icing)
Ambient environment No corrosive gases
Storage temperature
25 to 65°C (with no condensation or icing)
Protective structure IP20
Terminal construction Power supply and I/O Screwless terminal block (Phoenix Contact FFKDS/V1-5.08 or equivalent)
Serial D-sub, 9-pin (female) Inch screws (OMRON
XM2F-0910-132 or equivalent), Master station only
---
Safety standards UL: UL508 (Listing)
Weight 330 g max.
Item Specifications
Wave type Spread Spectrum (direct sequence; DS-SS)
Communication method Simplex
Frequency band 2,401 to 2,480.2 MHz
Number of channels 67 channels (based on switching)
Transmitter output power 10 mW/MHz
Baud rate between wireless stations 100 kbps
Communications distance (See note.) Indoors: 60 m min. (approx. 50 m min. with Magnet-base Antennas and Flat Diversity Antennas)
Outdoors: Approx. 300 m min. (anticipated distances) (without using relay stations)
Error detection method CRC-CCITT (16 bits)
Relay functions One stage using I/O slave for the serial master configuration.
Number of stations per area (See note.) 10 sets max. (recommended)
Number of I/O Slaves connected 64 max.
Page 3
FA Wireless SS Terminals WT30 3
Nomenclature
Serial Master Station
I/O Slave Station
Unit No. Switch
Set the unit number of the Serial Master Station
Default: 00
Node Setting Switch (WNODE)
Set the number of connected I/O Slave Stations. Set the node number of the Slave Stations being used as I/O Slave Stations. The Slave Station functions as a relay station when the node number is set to 99.
Default: 01
Channel Setting Switch (WCH)
Set the communications frequency.
Default: 02
Function Setting Switch
Serial Master Station
I/O Slave Station
Antenna terminal (ANT1)
Status indicators
RS-232C Terminal Connect the PLC, personal computer, etc.
Power supply terminal Supply power to the WT30.
Unit No. switch Set the unit number of the Serial Master Station.
Node setting switch (WNODE) Set the number of connected I/O Slave Stations.
Channel setting switch (WCH) Set the communications frequency channel.
Antenna terminal (ANT2)
Received signal strength indicator
Special function switch
Function setting switch Make the detailed settings for RUN/TEST/SET mode.
Mode selection switch Switch between RUN, TEST, and SET mode.
Serial communications setting switch Set the baud rate.
Status indicators
Power supply terminal Supply power to the WT30 and output circuits.
Mode selection switch Switch between RUN, TEST, and SET mode.
Node setting switch (WNODE) Set the unit number of the I/O Slave Station.
I/O terminal status indicators (0 to 7 or 8 to 15) The contact status is displayed.
Channel setting switch (WCH) Set the communications frequency.
Antenna terminal (ANT2)
Received signal strength indicator
Special function switch
Antenna terminal (ANT1)
Function setting switch Make the detailed settings for RUN/TEST mode.
I/O terminals Connect the contact signals.
No. Applicable
mode
ON functions OFF functions
1 RUN mode Holds I/O status data
when a communications error occurs.
Clears I/O status data when a communications error occurs.
2 Enable scan list Disable scan list
3 Relays used Relays not used
4 TEST mode Signal strength monitor
disabled
Signal strength monitor enabled
5 All channels
automatically switched
Specified channels
6 --- ---
7 SET mode Scan list recognition Nothing done
8 Registers specified I/O
slave
Registers all I/O slaves automatically
9 Recognizes serial
numbers
Ignores serial numbers
10 Not used --- ---
No. Applicable
mode
ON functions OFF functions
1 RUN mode Holds I/O status data
when a communications error occurs.
Clears I/O status data when a communications error occurs.
2 Input hold Normal mode
3 Input filter: 100 ms Input filter: 10 ms
4 TEST mode Signal strength monitor
disabled
Signal strength monitor enabled
5 All channels
automatically switched
Specified channels
6 Installation test
function
Nothing done
7 to 10Not used --- ---
Page 4
4 FA Wireless SS Terminals WT30
Serial Communications Setting Switch
Note: For example, if pins number 2, 3, and 4 are all ON, the total is
7, which corresponds to a baud rate of 115,200 bps.
Display
Note: When using the WD30 as the Serial Master Station, the ERR
indicator will light if normal I/O communications are not possible due to an error in the host network.
No. Function ON OFF
1 Communications setting
selection
Detailed settings (settings for No. 2 to 8 used)
Default settings (baud rate: 9,600 bps; data length: 7 bits; parity: even; stop bits:
2) Settings for No. 2 to 8 are ignored.
2 Baud rate (bps)
(See note.) Total value = 0: 1,200
= 1: 2,400 = 2: 4,800 = 3: 9,600 = 4: 19,200 = 5: 38,400 = 6: 57,600 = 7: 115,200
10
3 20
4 40
5 Data length 8 bits 7 bits
6 Parity None Yes
7 Odd Even
8 Stop bits 1 bit 2 bits
Indicator Color Status Meaning (primary error)
PWR Green Lit Power is being supplied.
Not lit Power is not being supplied.
ERR (Slave Station)
Red Lit Error output is ON:
Wireless device error or wireless communications error. (See note)
Not lit No wireless device error or
wireless communications error.
COMM (Master Station)
Yellow Lit Serial communications in
progress.
Not lit No serial communications.
0 to 15 (Slave Station)
Yellow Lit/Not lit ON/OFF status for input or
output signals
RSSI Red/
Yellow/ Green
Lit/ All not lit
Receiving Signal Strength Indicator monitor: Number of indicators lit (receiving signal strength 1 to 9) Receiving signal strength less than 0 to 1.
MS (Module Status)
Green Lit Communications are normal.
Flashing TEST mode or SET mode has
been activated.
Red Lit A fatal error has occurred that
cannot be recovered from. Replace the Unit
Flashing A non-fatal error has occurred
that can be recovered from by resetting the system.
--- Not lit Power is not being supplied or the system is resetting.
WS (Wireless Status)
Green Lit The station has joined the
wireless network.
Flashing Permission to join wireless
network received from Serial Master Station (Slave Station)
Red Lit A fatal error has occurred that
cannot be recovered from.
Flashing Error from which recovery is
possible
--- Not lit Wireless communications are not in progress.
Page 5
FA Wireless SS Terminals WT30 5
Wiring
Serial Master Station (WT30-M01-FLK)
I/O Characteristics
I/O Slave Station
RS-232C Connector
WT30
Power supply terminal Supply power to the Unit
54321
9876
D-sub, 9-pin, Female End at WT30
Pin No. Signal I/O direction
1 --- ---
2RDOutput
3 SD Input
4 --- ---
5 SG ---
6 --- ---
7 --- ---
8 --- ---
9 --- ---
VG 01 2 3
COM
IN
IN
4567
COM ERRP
24 V DC
0 V 8 9 10 11
COM
12 13 14 15
COM
ERRN
Power supply Inputs Inputs
Inputs Inputs
Error output
(
NPN
)
Error output
power supply
Error output
(PNP)
Error output
(NPN)
OUT
24 V DC
0 V 0 1 2 3
COM
4567
COM ERRN
Power supply Outputs Outputs
VG0 1 2 3
COMIN4567
COM ERRP
Inputs Inputs
Error output/output
power supply
Error output
(PNP)
WT30-SID16
WT30-SMD16 WT30-SMD-16-1
Item Specifications
Input Characteristics
Input voltage 24 V DC
Allowable voltage range
20.4 to 26.4 V DC
Input impedance
4.7 k
(typical)
Input current 5 mA (typical)
ON voltage/ current characteristics
17.4 V DC, 3.0 mA min.
OFF voltage/ current characteristics
5.0 V DC, 1.0 mA max.
Input filter 10 ms/100 ms (Selected using switch.)
Output/Error Output
Characteristics
Input voltage 24 V DC
Allowable voltage
20.4 to 26.4 V DC
Max. switching current
100 mA max. per output (at 20.4 to 26.4 V DC) Simultaneous usage of error output NPN/PNP is not possible.
Leakage current
0.1 mA max.
Residual voltage
1.0 V max.
Fuse One for every two outputs except for error
output circuits, which have one for every NPN/ PNP output. (No fuses can be replaced by the user.)
Page 6
6 FA Wireless SS Terminals WT30
Input Circuit Diagram
Error Output Circuit Diagram
Output Circuit Diagram (NPN)
Output Circuit Diagram (PNP)
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Serial Master Station
WT30-M01-FLK
I/O Slave Station
WT30-SID16 WT30-SMD16 WT30-SMD16-1
IN 0
IN 1
IN 2
IN 15
COM (IN)
Secondary internal circuit
V
G
ERRN
ERRP
Fuse
Secondary internal circuit
Fuse
V
G
OUT 0
OUT 1
OUT 2
OUT 7
Secondary internal circuit
Fuse
Fuse
Fuse
V
G
OUT 0
OUT 1
OUT 2
OUT 7
Fuse
OUT
3
Secondary internal circuit
Fuse
Four, 5 dia.
(15)
(15)
60 40
13.3
105 13.3
120
Surface mounting bracket WT30-FT003
105
90
7.3
DIN rail mounting bracket WT30-FT001 or WT30-FT002
Page 7
FA Wireless SS Terminals WT30 7
With Magnet-base Antenna
WT30-AT001
With Flat Diversity Antenna
WT30-AT002
With Pencil Antenna
WT30-AT003
Magnet-base Antenna
WT30-AT001
Flat Diversity Antenna
WT30-AT002
Pencil Antenna
WT30-AT003
DIN Rail Mounting Bracket
WT30-FT001 WT30-FT002
Surface Mounting Bracket
WT30-FT003
Flat Diversity Antenna Mounting Brackets (with magnets)
WT30-FT011
(34)
(32)
(38)
4.6
R38
R40
I/O Slave Station
DIN Rail mounting bracket WT30-FT001 or WT30-FT002
(23)
R50
20
I/O Slave Station
DIN Rail mounting bracke
t
WT30-FT001 or WT30-FT002
150
40
(46)
(46)
Surface Mounting Bracket WT30-FT003
Serial Master Station
115
2010
39
35.8 dia.
10.5 dia.
57.5
2010
57.5 Three, 3 dia.
52
26
10.5 dia
.
75
Page 8
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. N139-E1-01
OMRON Corporation
Industrial Automation Company
Industrial Devices and Components Division H.Q. Wireless Components Department
Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7116/Fax: (81)75-344-7189
Printed in Japan 0105
Loading...