Long-life Two-circuit Limit Switch WLM@ F-101
Limit
Switches
Specifications
■ Ratings
General-purpose Ratings
Refer to these ratings before using the product.
Screw Terminal Models
Note: Only for high-sensitivity overtravel models.
Direct-wired/Pre-wired Models
Note: 1. The above figures are for standard currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
■ Characteristics
Note: 1. The figures in parentheses for dielectric strength, are those for overtravel (high-sensitivity) or connector models.
2. The values are calculated at an operating temperature of 5°C to 35°C, and an operating humidity of 40% to 70%. Contact your OMRON
sales representative for more detailed information on other operating environments.
Model Rated
voltage
Non-inductive load Inductive load
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
Standard, overtravel
(except high-sensitivity),
and high-precision
115 VAC 10 3 1.5 10 5 2.5
12 VDC 10 6 3 10 6
24 VDC 6 4 3 6 4
48 VDC 3 2 1.5 3 2
115 VDC 0.8 0.2 0.2 0.8 0.2
Overtravel
(High-sensitivity)
115 VAC 5 --- --- --115 VDC 0.4 --- --- ---
Inrush current NC 30 A max. (15 A max. (See note))
NO 20 A max. (10 A max. (See note))
Model Rated
voltage
Non-inductive load Inductive load
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
DC12 VDC33333333
24 VDC33333333
48 VDC33333333
115 VDC 0.8 0.8 0.2 0.2 0.8 0.8 0.2 0.2
AC 115 VAC 3 3 3 1.5 3 3 3 2.5
Degree of protection IP67
Durability (See note 2.) Mechanical: 30,000,000 operations min. (10 mA at 24 VDC, resistive load)
Electrical: 750,000 operations min. (10 A at 115 VAC, resistive load),
but for high-precision models: 500,000 operations min. (10 A at 115 VAC, resistive load)
Operating speed 1 mm to 1 m/s (for WLMCA2)
Operating frequency Mechanical: 120 operations/minute
Electrical: 30 operations/minute
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ max. (initial value)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between non-continuous terminals. (Except connector models.)
2,200 VAC (1,500 V), 50/60 Hz for 1 min between non-current-carrying metal part and ground.
2,200 VAC (1,500 V), 50/60 Hz for 1 min between each terminal and non-current-carrying metal part.
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction: 1,000 m/s
2
min.
Malfunction: 300 m/s
2
min.
Ambient temperature Operating: –10°C to 80°C (with no icing)
Ambient humidity Operating: 95% max.
Weight Approx. 275 g (for WLMCA2)