Omron S8VT DATASHEET

Switch Mode Power Supply
S8VT 120/240/480/960 W Models
Natural Cooling Three-phase Power Supply Range from 5A up to 40A with Output Voltage of 24VDC
• 3 phase 400 to 500 VAC
• 5, 10, 20 and 40 A; 24 VDC output
• Mounts to DIN rail
• Fuses protection included
• Natural ventilation
• UL60950 (CSA22.2-60950), UL508 listing in addition to the CE mark
• Conform to EN61000-3-2
• Parallel & serial operation possible
Model Number Structure
Model Number Legend
S8VT - 24 E
123
1. Input Voltage
F: 400 to 500 VAC 3-phase
2. Power Rating
120: 120 W 240: 240 W 480: 480 W 960: 960 W
3. Output Voltage
24: 24 V
Ordering Information
List of Models
Input voltage Power rating Output voltage Output current Model number
120 W 24 V 5 A S8VT-F12024E
400 to 500 VAC 3-phase
240 W 24 V 10 A S8VT-F24024E
480 W 24 V 20 A S8VT-F48024E
960 W 24 V 40 A S8VT-F96024E
1
Specifications
S8VT
Item
Efficiency (400 VAC FULL LOAD) 86% 90% 91% 91%
Input
Output
Others
*1) UL approval up to 600 VDC *2) MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures,
and indicates reliability of devices.
Nominal Input Voltage F: 400 to 500 VAC
Nominal Input Current 5 A 10 A 20 A 40 A
Voltag e range 340 to 576 V 3AC resp. 480 to 810 VDC
Frequency 50 to 60 Hz
Current (max.) (Vin = Range min., Pmax)
Power factor (400 VAC FULL LOAD)
Leakage current (max.) <3.5mA <3.5mA <3.5mA <3.5mA
Inrush current (max.) (Pmax)
EMI filter 2×10 mH 2×27 mH 2×6.8 mH 2×2.2 mH
Line fuses T2A T3.15A T4A T6.3A
Voltage adjustment range 21.6 to 28.0 VDC min.
Tolerance adjustment accuracy
Ripple & noise (Pmax.) 100 mV max. (p.p. 0-20 MHz)
Load variation influence ±0.5% max.
Input variation influence ±0.25% max.
Temperature variation influence
Startup time (max.) 1.3 s 1.3 s 1.3 s 1.3 s
Hold time (min.) (Vin = 400 VAC)
Protection
Parallel operation Yes (for two units)
Serial operation Yes (for two units)
Indicator Yes (Green LED)
Heat radiation Natural air cooling
Ambient temperature -10 to 70°C (de-rating: 5%/°C for 60 to 70°C)
Temperature power derating 60 to 70°C see diagram
Storage temperature -40 to 85°C
Ambient humidity 10 to 90% noncondensing
Dielectric strength
Insulation resistance 500 Mohm min at 500 VDC, Output - P.E.
Vibration resistance
Shock resistance 150 m/s², 3 times each in ±X, ±Y, ±Z directions
EMC
Approval standards
(AC and DC input)
Life expectancy 10 years (Vin=400-500 VAC 50% of rated output current Ta=40°C)
MTBF *2
Weight 0.71 kg 0.91 kg 1.8 kg 3.3 kg
0.5A 1A 1.5A 3A
0.66 0.66 0.86 0.86
< 30A @ Vin max. < 30A @ Vin max. < 40A @ Vin max. < 30A @ Vin max.
1%
Less than 0.05%/°C
15 ms 15 ms 15 ms 15 ms
- Short circuit protection continuative
- Over load protection
- Over voltage protection
2.5 kVAC Input-PE (for 1 sec.; routine test) 3 kVAC Input-Output on isolation components (transformers) (for 1 sec.; high-pot routine test) 1 kVAC Output-PE (for 1 sec.; routine test).
10 to 55 Hz, 0.375 mm single amplitude for 2 h each in X, Y and Z directions 10 to 150 Hz, 0.35 mm single amplitude for 80 min each in-X, Y and Z directions
EN55011 (EN55022) EN61000-3-2, EN61000-4-2, EN61000-4-3,EN61000-4-4,EN61000-4-5, EN61000-4-6,EN61000-4-8,EN61000-4-11, EN61204-3
IEC60950-1, EN60950-1 UL60950-1, CSA 22.2 No. 60950-1, UL508 Listed *1, EN50178, EN60204
> 300.000hrs