Thank you for choosing this OMNUC W-series product. Proper use and handling of the product will ensure proper product performance, will length product life, and may prevent possible
accidents.
Please read this manual thoroughly and handle and operate the product with care.
1.To ensure safe and proper use of your OMRON Servomotors and Servo Drivers, please read this manual
(Cat. No. I544-E1) to gain sufficient knowledge of the products, safety information, and precautions before
actual use.
2.The products are illustrated without covers and shieldings to enable showing better detail in this manual.
For actual use of the products, make sure to use the covers and shieldings as specified.
3.Copies of this manual and other related manuals must be delivered to the actual end users of the products.
4.Please keep a copy of this manual close at hand for future reference.
5.If a product has been left unused for a long time, please consult with your OMRON sales representative.
NOTICE
1.This manual describes the functions of the product and relations with other products. You
should assume that anything not described in this manual is not possible.
2.Although care has been given in documenting the product, please contact your
OMRON representative if you have any suggestions on improving this manual.
The product contains dangerous high voltages inside. Turn OFF the power and wait for at least
3.
five minutes to allow power to discharge before handling or working with the product. Never
attempt to disassemble the product.
4.We recommend that you add the following precautions to any instruction manuals you prepare
for the system into which the product is being installed.
• Precautions on the dangers of high-voltage equipment.
• Precautions on touching the terminals of the product even after power has been turned
OFF. (These terminals are live even with the power turned OFF.)
5.Specifications and functions may be changed without notice in order to improve product performance.
6.Positive and negative rotation of AC Servomotors described in this manual are defined as looking at the end of the output shaft of the motor as follows: counterclockwise rotation is positive
and clockwise rotation is negative.
7.Do not perform withstand-voltage or other megameter tests on the product. Doing so may
damage internal components.
8.Servomotors and Servo Drivers have a finite service life. Be sure to keep replacement products on hand and to consider the operating environment and other conditions affecting the service life.
9.The OMNUC W Series can control both incremental and absolute encoders. Differences in
functions or specifications according to the encoder type are indicated in this manual. Be sure
to check the model that is being used, and follow the relevant specifications.
• Servomotors with incremental encoders:R88M-W@H-@
• Servomotors with absolute encoders:R88M-W@T- @
Items to Check After Unpacking
1.Check the following items after removing the product from the package:
• Has the correct product been delivered (i.e., the correct model number and specifications)?
• Has the product been damaged in shipping?
• Are any screws or bolts loose?
USER’S MANUAL
OMNUC WSERIES
MODELS R88M-W@
(AC Servomotors)
MODELS R88D-WN@-ML2
(AC Servo Drivers)
AC SERVOMOTORS/SERVO DRIVERS
WITH BUILT-IN MECHATROLINK-II COMMUNICATIONS
Notice:
r
f
OMRON products are manufactured for use according to proper procedures by a qualified operator
and only for the purposes described in this manual.
The following conventions are used to indicate and classify precautions in this manual. Always heed
the information provided with them. Failure to heed precautions can result in injury to people or damage to property.
!DANGER Indicates an imminently hazardous situation which, if not avoided, will result in
death or serious injury. Additionally, there may be severe property damage.
!WARNINGIndicates a potentially hazardous situation which, if not avoided, could result in
death or serious injury. Additionally, there may be severe property damage.
!CautionIndicates a potentially hazardous situation which, if not avoided, may result in
minor or moderate injury, or property damage.
OMRON Product References
All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to
an OMRON product, regardless of whether or not it appears in the proper name of the product.
The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means
“word” and is abbreviated “Wd” in documentation in this sense.
The abbreviation “PC” means Programmable Controller and is not used as an abbreviation for anything
else.
Visual Aids
The following headings appear in the left column of the manual to help you locate different types of
information.
Note Indicates information of particular interest for efficient and convenient operation of the product.
OMRON, 2004
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, o
by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission o
OMRON.
No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without
notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility
for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in
this publication.
General Warnings
Observe the following warnings when using the OMNUC Servomotor and Servo Driver and all connected or peripheral devices.
This manual may include illustrations of the product with protective covers removed in order to
describe the components of the product in detail. Make sure that these protective covers are on the
product before use.
Consult your OMRON representative when using the product after a long period of storage.
!WARNINGAlways connect the frame ground terminals of the Servo Driver and the Servomo-
tor to a class-3 ground (to 100
result in electric shock.
!WARNINGDo not touch the inside of the Servo Driver. Doing so may result in electric shock.
!WARNINGDo not remove the front cover, terminal covers, cables, Parameter Units, or
optional items while the power is being supplied. Doing so may result in electric
shock.
!WARNINGInstallation, operation, maintenance, or inspection must be performed by autho-
rized personnel. Not doing so may result in electric shock or injury.
Ω or less). Not connecting to a class-3 ground may
!WARNINGWiring or inspection must not be performed for at least five minutes after turning
OFF the power supply. Doing so may result in electric shock.
!WARNINGDo not damage, press, or put excessive stress or heavy objects on the cables.
Doing so may result in electric shock.
!WARNINGDo not touch the rotating parts of the Servomotor in operation. Doing so may
result in injury.
!WARNINGDo not modify the product. Doing so may result in injury or damage to the product.
!WARNINGProvide an appropriate stopping device on the machine side to secure safety. (A
holding brake is not a stopping device for securing safety.) Not doing so may result
in injury.
!WARNINGProvide an external emergency stopping device that allows an instantaneous stop
of operation and power interruption. Not doing so may result in injury.
!WARNINGDo not come close to the machine immediately after resetting momentary power
interruption to avoid an unexpected restart. (Take appropriate measures to secure
safety against an unexpected restart.) Doing so may result in injury.
!CautionUse the Servomotors and Servo Drivers in a specified combination. Using them
incorrectly may result in fire or damage to the products.
!CautionDo not store or install the product in the following places. Doing so may result in
fire, electric shock, or damage to the product.
• Locations subject to direct sunlight.
• Locations subject to temperatures or humidity outside the range specified in the specifications.
• Locations subject to condensation as the result of severe changes in temperature.
• Locations subject to corrosive or flammable gases.
• Locations subject to dust (especially iron dust) or salts.
• Locations subject to shock or vibration.
• Locations subject to exposure to water, oil, or chemicals.
!CautionDo not touch the Servo Driver radiator, regeneration resistor, or Servomotor while
the power is being supplied or soon after the power is turned OFF. Doing so may
result in a skin burn due to the hot surfaces.
Storage and Transportation Precautions
!CautionDo not hold the product by the cables or motor shaft while transporting it. Doing so
may result in injury or malfunction.
!CautionDo not place any load exceeding the figure indicated on the product. Doing so
may result in injury or malfunction.
!CautionUse the motor eye-bolts only for transporting the Motor. Using them for transport-
ing the machinery may result in injury or malfunction.
Installation and Wiring Precautions
!CautionDo not step on or place a heavy object on the product. Doing so may result in
injury.
!CautionDo not cover the inlet or outlet ports and prevent any foreign objects from entering
the product. Doing so may result in fire.
!CautionBe sure to install the product in the correct direction. Not doing so may result in
malfunction.
!CautionProvide the specified clearances between the Servo Driver and the control panel
or with other devices. Not doing so may result in fire or malfunction.
!CautionDo not apply any strong impact. Doing so may result in malfunction.
!CautionBe sure to wire correctly and securely. Not doing so may result in motor runaway,
injury, or malfunction.
!CautionBe sure that all the mounting screws, terminal screws, and cable connector
screws are tightened to the torque specified in the relevant manuals. Incorrect
tightening torque may result in malfunction.
!CautionUse crimp terminals for wiring. Do not connect bare stranded wires directly to ter-
minals. Connection of bare stranded wires may result in burning.
!CautionAlways use the power supply voltage specified in the User's Manual. An incorrect
voltage may result in malfunction or burning.
!CautionTake appropriate measures to ensure that the specified power with the rated volt-
age and frequency is supplied. Be particularly careful in places where the power
supply is unstable. An incorrect power supply may result in malfunction.
!CautionInstall external breakers and take other safety measures against short-circuiting in
external wiring. Insufficient safety measures against short-circuiting may result in
burning.
!CautionTake appropriate and sufficient countermeasures when installing systems in the
following locations:
• Locations subject to static electricity or other forms of noise.
• Locations subject to strong electromagnetic fields and magnetic fields.
• Locations subject to possible exposure to radioactivity.
• Locations close to power supplies.
!CautionDo not reverse the polarity of the battery when connecting it. Reversing the polar-
ity may damage the battery or cause it to explode.
Operation and Adjustment Precautions
!CautionConfirm that no adverse effects will occur in the system before performing the test
operation. Not doing so may result in equipment damage.
!CautionCheck the newly set parameters for proper execution before actually running
them. Not doing so may result in equipment damage.
!CautionDo not make any extreme adjustments or setting changes. Doing so may result in
unstable operation and injury.
!CautionSeparate the Servomotor from the machine, check for proper operation, and then
connect to the machine. Not doing so may cause injury.
!CautionWhen an alarm occurs, remove the cause, reset the alarm after confirming safety,
and then resume operation. Not doing so may result in injury.
!CautionDo not use the built-in brake of the Servomotor for ordinary braking. Doing so may
result in malfunction.
Maintenance and Inspection Precautions
!CautionResume operation only after transferring to the new Unit the contents of the data
required for operation. Not doing so may result in an unexpected operation.
!CautionDo not attempt to disassemble, repair, or modify any Units. Any attempt to do so
may result in malfunction, fire, or electric shock.
Warning Labels
Warning labels are pasted on the product as shown in the following illustration. Be sure to follow the
instructions given there.
Warning label
Precautions for Safe Use
Dispose of the product and batteries according to local ordinances as they apply.
Have qualified specialists properly dispose of used batteries as industrial waste.
Read and Understand this Manual
Please read and understand this manual before using the product. Please consult your OMRON
representative if you have any questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a
period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NONINFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE
PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which
liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS
REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS
WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO
CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the
combination of products in the customer's application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying
ratings and limitations of use that apply to the products. This information by itself is not sufficient for a
complete determination of the suitability of the products in combination with the end product, machine,
system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not
intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses
listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or
uses not described in this manual.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical
equipment, amusement machines, vehicles, safety equipment, and installations subject to separate
industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR
PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any
consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other
reasons.
It is our practice to change model numbers when published ratings or features are changed, or when
significant construction changes are made. However, some specifications of the products may be changed
without any notice. When in doubt, special model numbers may be assigned to fix or establish key
specifications for your application on your request. Please consult with your OMRON representative at any
time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when
tolerances are shown.
PERFORMANCE DATA
Performance data given in this manual is provided as a guide for the user in determining suitability and does
not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must
correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and
Limitations of Liability.
ERRORS AND OMISSIONS
The information in this manual has been carefully checked and is believed to be accurate; however, no
responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
OMNUC W-series AC Servo Drivers with built-in MECHATROLINK-II Communications
are designed specifically for use with the MECHATROLINK-II high-speed motion field
network.
Combining these Servo Drivers with MECHATROLINK-II-compatible Motion Control
Units (CS1W-MCH71 or CJ1W-MCH71) or Position Control Units (CJ1W-NCF71) is an
easy way to create a high-speed servo control system with a communications link
between the Servo Drivers and the Controllers.
■ Data Transfer by MECHATROLINK-II Communications
When a Servo Driver is combined with a MECHATROLINK-II-compatible Motion Control Unit (CS1WMCH71 or CJ1W-MCH71) or Position Control Unit (CJ1W-NCF71), all control data is transferred
between the Servo Driver and the Controller by means of data communications.
Control commands are transferred by means of data communications, so Servomotor performance is
not limited by control interface specifications, such as response frequencies for input pulses and
encoder feedback pulses. This allows the Servomotor to perform to its fullest capacity.
Moreover, system data control is simplified by having all Servo Driver parameters and monitor data
managed by the host controller.
■ Built-in Communications Interface
The MECHATROLINK-II communications interface has been built into the Servo Driver. In comparison with earlier W-series Servo Drivers, in which the MECHATROLINK-II Application Module is
installed, only 60% of the installation surface area is required. (for 200-V/100-W Servo Drivers). This
allows a great saving of space in the control panel.
■ W-series Servomotor Compatibility
A W-series Servomotor can be used as is, including the encoder cable and power cable, so the system can be upgraded without changing the structural design.
The W-series product line offers 3,000-r/min Servomotors (Cylinder-style: 50-W to 3-kW; Flat-style:
100-W to 1.5-kw), 1,000-r/min Servomotors (300-W to 2-kW), and 1,500-r/min Servomotors (450-W
to 1.8-kW). Also, IP67 (waterproof) Servomotors can be connected in the same way.
■ High-speed, High-precision Motion Control Capability
A less-deviation control function and a predictive control function are provided to shorten the Servomotor's settling time and achieving high tracking capability.
The W-series Servomotors handle motion control with increased speed and precision, including synchronous control in combination with CS1W-MCH71 or CJ1W-MCH71 Motion Control Units.
1-2
Introduction
■ Regenerative Power Processing
In addition to the built-in regenerative power processing function using regeneration resistance,
external regeneration resistance can also be connected, allowing the W Series to be used for applications with high regenerative energy on vertical axes.
■ Conformity to Standards
The W Series conforms to EC Directives (both low-voltage and EMC) as well as to UL and cUL
requirements, thereby assisting the user in meeting required standards.
■ High-frequency Current Countermeasures
On Servo Drivers of 1 kW and above, a current reactor connection terminal is provided to assist the
user in controlling high-frequency current.
Chapter 1
1-3
Introduction
INC
ABS
Controller (MECHATROLINK-II Type)
Controller (MECHATROLINK-II Type)
MCH71
1-2System Configuration
Controller (MECHATROLINK-II Type)
N
C
F
7
1
M
L
K
R
U
N
E
R
C
E
R
H
E
R
M
C
B
D
A
U
NIT
9
E
0
8
F
1
7
N
o.
2
6
3
5
4
M
LK
P
A
2
0
5
R
P
S
O
Y
W
E
R
SYSMAC CJ1
Programmable Controller
R
U
S
N
M
A
C
E
R
R
/
A
L
M
C
J
1
G
C
P
U
4
4
I
N
H
P
R
O
G
R
A
M
M
A
B
L
E
P
R
P
H
L
C
O
N
T
R
O
L
L
E
R
C
O
M
M
O
P
E
N
M
C
P
W
R
L
1
B
U
S
Y
A
C
1
0
0
2
4
0
V
I
N
P
U
T
L
2
/
N
P
ERI
PH
E
R
AL
R
U
N
O
U
T
P
U
T
A
C
2
4
0
V
D
C
2
4
V
P
O
R
T
CJ1W-NCF71
Position Control Unit
M
C
H
7
1
C
B
D
A
9
E
0
8
F
1
7
2
6
3
5
4
CJ1W-MCH71
Motion Control Unit
Chapter 1
MECHATRO
LINK-II
R88D-WN@@@-ML2
OMNUC W-series AC
Servo Driver with builtin MECHATROLINK-II
Communications
MECHATRO
LINK-II
Controller (MECHATROLINK-II Type)
SYSMAC CS1
Programmable Controller
M
C
H
7
1
R
U
N
E
R
C
E
R
H
E
R
1
E
R
3
E
R
2
E
R
4
S
S
I
M
L
K
U
N
I
T
N
o
.
T
.
B
.
S
S
I
I
/
O
M
L
K
CS1W-MCH71
Motion Control Unit
INC
ABS
R88M-W@
OMNUC W-series
AC Servomotor
1-4
Introduction
1-3Servo Driver Nomenclature
With Top Cover Open
ON
SW1
4
3
2
1
0
F
E
CHARGE
1234
POWER
5
6
7
8
9
A
B
C
D
POWER
COM
COM
DIP Switch
Used for MECHATROLINK-II
communications settings.
Model Number
Rotary Switch (SW1)
Used for setting MECHATROLINK-II
node address.
Charge Indicator
Lit when the main-circuit is powered.
Also, for Servo Drivers of 1 kW or less,
the indicator lights dimly when only the
control power supply is ON. Even after
the power is turned OFF, it remains lit
as long as an electric charge remains in
the main-circuit capacitor, so do not
touch the Servo Driver's terminals
during this period.
Main-circuit Power Terminals
These are the input terminals for
the main-circuit power supply.
R88D-WN01H-ML2
AC SERVO DRIVER
200
100
W
V
A/B
Chapter 1
Analog Monitor Connector (CN5)
Motor rotation speeds, torque
command values, etc., can be
monitored using a special cable.
Panel Display
Displays Servomotor status with
a 7-segment LED display.
Power Indicator (POWER)
Lit when the control power is
being supplied.
Communications Indicator (COM)
Lit when MECHATROLINK-II
communications are in progress.
Control I/O Connector (CN1)R88A-CNW01C
Encoder Connector (CN2)R88A-CNW01R
Encoder Connector for Motor
End
Absolute Encoder Battery
Cable (with Battery)
DOS/V 2 m R88A-CCW002P2
1 m R88A-CMW001S
R88A-CNW02R
R88A-CRWC0R3C
Note Required when using a Servomotor with
an absolute encoder. The cable and connector are included.
■ Reactors
SpecificationsModel
For R88D-WNA5L-ML2/01L-ML2/
02H-ML2
For R88D-WN02L-ML2/04H-ML2R88A-PX5054
For R88D-WN04L-ML2/08H-ML2R88A-PX5056
For R88D-WNA5H-ML2/01H-ML2R88A-PX5052
For R88D-WT04H-ML2R88A-PX5069
For R88D-WN05H-ML2/10H-ML2R88A-PX5061
For R88D-WN15H-ML2/20H-ML2R88A-PX5060
For R88D-WN30H-ML2R88A-PX5059
■ Front-panel Brackets
SpecificationsModel
For R88D-WNA5L-ML2 to 04LML2
For R88D-WNA5H-ML2 to 10HML2
For R88D-WN15H-ML2R88A-TK06W
For R88D-WN20H-ML2/30H-ML2R88A-TK07W
R88A-PX5053
R88A-TK05W
R88A-TK05W
Note Required when mounting a Servo Driver
from the front panel.
Note In order to use a personal computer to
monitor a Servo Driver and set its parameters, Computer Monitor Cable and Computer Monitor Software are required.
Please ask an OMRON representative for
details.
■ Absolute Encoder Backup
Battery
SpecificationsModel
1,000 mA·h, 3.6 V R88A-BAT01W
2-2
Loading...
+ 382 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.