EtherNet/IP master
CJ-series CPU Unit or master from another manufacturer
Communications cable
Ethernet cables
NX-series EtherNet/IP
Coupler Unit NX-EIC202
Sysmac Studio
Support Software
End Cover
NX Units *
EtherNet/IP port
EtherNet/IP Unit
Peripheral USB port
Network Configurator
Connection to peripheral USB
port on EtherNet/IP Coupler Unit
Industrial Switching Hubs
W4S1
EDS files
Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products.
EtherCAT
is a registered trademark of Beckhoff Automation GmbH for their patented technology. EtherNet/IPTM is the trademarks of ODVA.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
NX-EIC
CSM_NX-EIC_DS_E_4_3
Connecting to open industrial network standard
EtherNet/IP
• The EtherNet/IP Coupler Unit is the link between the EtherNet/IP multivendor
network and the NX-series I/O Units and Safety Units. With wide variety of
the I/O Units and Safety Units, the NX-series is the perfect match for the
CJ-series and multivendor Controllers.
Features
• Up to 63 NX-IO Units can be connected to one EtherNet/IP Coupler Unit. Standard and high-performance units can be mixed.*
• Each Coupler plus its I/O form just a single EtherCAT node on the network.
• I/O control and safety control can be integrated by connecting Units for safety.
• The IP address can be found on the label on the Unit, without using software.
• Slave configuration by Sysmac Studio can be done centrally via the controller, or on-the-spot using the Coupler's built-in USB port.
* Input per Coupler Unit: Maximum 504 bytes, Output per Coupler Unit: Maximum 504 bytes
System Configuration
System Configuration of Slave Terminals
Note: Do not make a loop connection in the communications path between Ethernet switches.
* Refer to Configuration Unit on page 8 for the NX Units that can be connected to the NX-series EtherNet/IP Coupler Unit.
1
NX-EIC
Ordering Information
Applicable standards
Refer to the OMRON website (www.ia.omron.com) or ask your OMRON representative for the most recent applicable standards for each model.
EtherNet/IP Coupler Unit
Product nameCurrent consumptionMaximum I/O power supply currentModel
EtherNet/IP Coupler Unit
1.60 W or lower10 ANX-EIC202
Automation Software Sysmac Studio
Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available
individually. Each model of licenses does not include any DVD.
Product nameSpecificationsModel
Sysmac Studio NX-I/O Edition is a limited license that
Sysmac Studio
NX-I/O Edition
Ver.1.@@
Sysmac Studio
Standard Edition
Ver.1.@@
*1. Model "SYSMAC-SE200D-64" runs on Windows 10 (64 bit).
*2. The Sysmac Studio Standard Edition with license(s) (SYSMAC-SE@@@L) provides functions of the NX-I/O Edition (SYSMAC-NE001L).
*3. With the Sysmac Studio Standard Edition with license(s) (SYSMAC-SE@@@L) version 1.10 or higher, you can use the setup functions for the
EtherNet/IP Coupler.
*4. Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).
provides selected functions required for EtherNet/IP
Coupler settings.
Because this product is a license only, you need the
Sysmac Studio Standard Edition DVD media to install
it.
The Sysmac Studio is the software that provides an
integrated environment for setting, programming,
debugging and maintenance of machine automation
controllers including the NJ/NX-series CPU Units, NYseries Industrial PC, EtherCAT Slave, and the HMI.
Sysmac Studio runs on the following OS.
Windows 7 (32-bit/64-bit version)/
Windows 8 (32-bit/64-bit version)/
Windows 8.1 (32-bit/64-bit version)/
Windows 10 (32-bit/64-bit version) *1
This software provides functions of the Vision Edition.
Refer to your OMRON website for details such as
supported models and functions.
Number of
licenses
1 license---SYSMAC-NE001L
--(Media only)
--(Media only)
1 license *2 *3 *4---SYSMAC-SE201L
Media
Sysmac
Studio
(32-bit)
DVD
Sysmac
Studio
(64-bit)
DVD
SYSMAC-SE200D
SYSMAC-SE200D-64
2
NX-EIC
Connecting Cable
Peripheral (USB) Port
Use a commercially available USB-certified cable.
Specifications: USB 1.1 or 2.0 cable (A connector - B connector), 5.0 m max.
Recommended EtherNet/IP Communications Cables
For EtherNet/IP, required specification for the communications cables varies depending on the baud rate. For 100BASE-TX/10BASE-T, use a
straight or cross STP (shielded twisted-pair) cable of category 5 or higher. For 1000BASE-T, use a straight or cross STP cable of category 5e or
higher with double shielding (aluminum tape and braiding).
Cable with Connectors
ItemAppearance
Cable with Connectors on Both Ends
(RJ45/RJ45)
Standard RJ45 plugs type *1
Wire Gauge and Number of Pairs:
AWG26, 4-pair Cable
Cable Sheath material: LSZH *2
Cable color: Yellow *3
Cable with Connectors on Both Ends
(RJ45/RJ45)
Rugged RJ45 plugs type *1
Wire Gauge and Number of Pairs:
AWG22, 2-pair Cable
Cable color: Light blue
Cable with Connectors on Both Ends
(M12 Straight/M12 Straight)
Shield Strengthening Connector cable *4
M12/Smartclick Connectors
Wire Gauge and Number of Pairs:
AWG22, 2-pair Cable
Cable color: Black
Cable with Connectors on Both Ends
(M12 Straight/RJ45)
Shield Strengthening Connector cable *4
M12/Smartclick Connectors
Rugged RJ45 plugs type
Wire Gauge and Number of Pairs:
AWG22, 2-pair Cable
Cable color: Black
*1. Standard type cables length 0.2, 0.3, 0.5, 1, 1.5, 2, 3, 5, 7.5, 10, 15 and 20 m are available. Rugged type cables length 0.3, 0.5, 1, 2, 3, 5, 10
and 15 m are available. For details, refer to Cat.No.G019.
*2. The lineup features Low Smoke Zero Halogen cables for in-cabinet use and PUR cables for out-of-cabinet use. Although the LSZH cable is
single shielded, its communications and noise characteristics meet the standards.
*3. Cables colors are available in blue, yellow, or Green.
*4. For details, contact your OMRON representative.
Recommended
manufacturer
OMRON
OMRON
OMRON
OMRON
Cable length (m)Model
0.3XS6W-6LSZH8SS30CM-Y
0.5XS6W-6LSZH8SS50CM-Y
1XS6W-6LSZH8SS100CM-Y
2XS6W-6LSZH8SS200CM-Y
3XS6W-6LSZH8SS300CM-Y
5XS6W-6LSZH8SS500CM-Y
0.3XS5W-T421-AMD-K
0.5XS5W-T421-BMD-K
1XS5W-T421-CMD-K
2XS5W-T421-DMD-K
5XS5W-T421-GMD-K
10XS5W-T421-JMD-K
0.5XS5W-T421-BM2-SS
1XS5W-T421-CM2-SS
2XS5W-T421-DM2-SS
3XS5W-T421-EM2-SS
5XS5W-T421-GM2-SS
10XS5W-T421-JM2-SS
0.5XS5W-T421-BMC-SS
1XS5W-T421-CMC-SS
2XS5W-T421-DMC-SS
3XS5W-T421-EMC-SS
5XS5W-T421-GMC-SS
10XS5W-T421-JMC-SS
3
Cables / Connectors
Protrusions for removing the Unit
Unit hookup guide
Unit hookup guide
Protrusions for removing the Unit
ItemRecommended manufacturerModel
Products for EtherNet/IP
(100BASE-TX)
Products for EtherNet/IP
(100BASE-TX)
*1. We recommend you to use above cable for EtherNet/IP and RJ45 Connector together.
*2. We recommend you to use above cable for EtherNet/IP and RJ45 Assembly Connector together.
Wire Gauge and
Number of
Pairs: AWG24, 4-pair
Cable
Wire Gauge and
Number of
Pairs: AWG22, 2-pair
Cable
Cables
RJ45 ConnectorsPanduit CorporationMPS588-C *1
Cables
RJ45 Assembly
Connector
Hitachi Cable, Ltd.
Kuramo Electric Co.KETH-SB *1
SWCC Showa Cable Systems Co. FAE-5004 *1
Kuramo Electric Co.KETH-PSB-OMR *2
JMACS Japan Co., Ltd.PNET/B *2
OMRONXS6G-T421-1 *2
NETSTAR-C5E SAB
× 4P CP *1
0.5
Optional Products
Product nameSpecificationModel
Unit/Terminal Block Coding Pins
Product name
Terminal Block8A/BProvided10 ANX-TBC082
Pins for 10 Units
(30 terminal block pins and 30 Unit pins)
No. of terminals
Terminal number
indications
Specification
Ground terminal
mark
Terminal current
capacity
NX-AUX02
NX-EIC
Model
Accessories
End Cover (NX-END01)
One End Cover is provided together with the EtherNet/IP Coupler Unit.
4
NX-EIC
General Specification
ItemSpecification
EnclosureMounted in a panel
Grounding methodGround to 100 Ω or less
Ambient operating temperature 0 to 55°C
Ambient operating humidity10% to 95% (with no condensation or icing)
AtmosphereMust be free from corrosive gases.
Ambient storage temperature−25 to 70°C (with no condensation or icing)
Altitude2,000 m max.
Operating
environment
Applicable standards *2
*1. Refer to the NX-series Digital I/O Units User’s Manual (Cat. No. W521) for the vibration and shock resistance specifications of the Relay Output
Unit.
*2. Refer to the OMRON website (http://www.ia.omron.com/) or consult your OMRON representative for the most recent applicable standards for
each model.
Pollution degreePollution degree 2 or less: Meets IEC 61010-2-201.
Noise immunityConforms to IEC 61000-4-4. 2 kV (power supply line)
Overvoltage categoryCategory II: Meets IEC 61010-2-201.
EMC immunity levelZone B
Vibration resistance
Shock resistanceConforms to IEC 60068-2-27. 147 m/s2, 3 times each in X, Y, and Z directions *1
Conforms to IEC 60068-2-6.
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m/s2, 100 min each in
X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) *1
cULus: Listed UL508, ANSI/ISA 12.12.01
EU: EN 61131-2, C-Tick or RCM, KC: KC Registration
EtherNet/IP Coupler Unit Specifications
ItemSpecification
ModelNX-EIC202
Number of connectable NX Units63 Units max.*1
EtherNet/IP
Number of buffers (sockets):
• 8 message buffers for server
• No message buffers for client
• Shared buffers for UDP/IP messages and TCP/IP
Communications protocols
ModulationBaseband
Link speed100 Mbps
Physical layer100BASE-TX (IEEE 802.3)
Number of connections8
Received Packet Interval (RPI, refresh cycle)4 to 1,000 ms
Allowed communications bandwidth
addressing to the local node
TopologyLine, Tree, Star
Ethernet SwitchLayer 2 Ethernet switch
Transmission media
Transmission distanceDistance between nodes: 100 m or less
NX bus I/O data size
EtherNet/IP I/O connection size
Refreshing methodsFree-Run refreshing
Power supply voltage24 VDC (20.4 to 28.8 VDC)
NX Unit power supply capacity 10 W max. (Refer to Installation orientation and restrictions for details.)
Unit power
supply *2
I/O power
supply *2
NX Unit power consumption1.60 W max.
Current consumption from I/O power supply10 mA max. (for 24 VDC)
*1. Refer to the NX-series Safety Control Unit User's Manual (Cat. No. Z930) for the number of Safety Control Units that can be connected.
*2. Refer to the NX-series EtherNet/IP™Coupler Unit User’s Manual (Cat. No. W536) for procedures for designing the Unit power supply system
and I/O power supply system.
*3. Use a voltage that is appropriate for the I/O circuits of the NX Units and the connected external devices.
NX Unit power supply efficiency
Isolation methodNo isolation between NX Unit power supply and Unit power supply terminals
Current capacity of power
supply terminals
Power supply voltage5 to 24 VDC (4.5 to 28.8 VDC) *3
Maximum I/O power supply current
Current capacity of power
supply terminals
UDP/IP and TCP/IP (Message Services)
1,000 pps
Category 5 or higher twisted-pair cable (Recommended cable:
double-shielded cable with aluminum tape and braiding)
Input: 512 bytes max. (including input data, status, and unused areas)
Output: 512 bytes max. (including output data and unused areas)
Input: 504 bytes max. (including input data, status, and unused areas)
Output: 504 bytes max. (including output data and unused areas)
70%
4 A max.
10 A (Refer to Installation orientation and restrictions for details.)
10 A max.
messages
Maximum message size:
• Request: 492 bytes
• Response: 496 bytes
Maximum NX output data size:
• 490 bytes
Maximum NX input data size:
• 496 bytes
5
ItemSpecification
0 10 20 30 40 45 50 55 60
Ambient temperature [°C]
10
8
4
2
0
6
12
Unit power supply [W]
10 W output, 40°C
8.5 W output, 55°C
0 10 20 30 40 45 50 55 60
Ambient temperature [°C]
10
8
4
2
0
6
12
Unit power supply [W]
10 W output, 40 °C
6.0 W output, 55°C
0 10 20 30 40 45 50 55 60
Ambient temperature [°C]
10
8
4
2
0
6
12
°C
6 A current, 55°C
10 A current, 45
I/O power supply [A]
Dielectric strength510 VAC for 1 min, leakage current: 5 mA max. (between isolated circuits)
Insulation resistance100 VDC, 20 MΩ min. (between isolated circuits)
Communications Connector
For EtherNet/IP communications.
• RJ45 × 2 (shielded)
External connection terminals
Dimensions46 × 100 × 71 mm (W×H×D)
Weight150 g max.
Screwless Clamping Terminal Block
For Unit power supply, I/O power supply, and grounding. Removable.
Peripheral USB Port
For Sysmac Studio connection.
• Physical layer: USB 2.0-compliant, B-type connector
• Transmission distance: 5 m max.
Installation orientation: 6 possible orientations
Restrictions:
• Used in the upright installation orientation.
NX-EIC
Installation orientation and restrictions
• Used in any other orientation than the upright installation orientation.
6
Circuit layout
NX Unit
power supply +
NX Unit
power supply −
Terminal
block
I/O power
supply +
I/O power
supply −
DIN Track contact plate
Peripheral
USB port
IN communications
connector
OUT communications
connector
NX bus
connector
UV
UV
UG
UG
IOV
IOG
UNIT PWR LED
I/O PWR LED
Internal
circuits
Non-isolated
power supply
circuits
IOV
UG
UV
IOG
UV
UG
A1
A8
B1
B8
Unit power supply
(24 VDC)
Through-wiring
for unwired
terminals.
I/O power supply
(5 to 24 VDC)
Ground to 100 Ω
or less.
NX-EIC
ItemSpecification
Terminal arrangement
AccessoryEnd Cover (NX-END01): 1
7
Configuration Unit
Refer to the user's manuals for information on the NX Units that can be connected to the NX-series EtherNet/IP Coupler Unit.
EtherNet/IP Coupler Unit
UnitModel
EtherNet/IP Coupler UnitNX-EIC202
I/O Units
Unit
Digital Input Unit−
Digital Output Unit
Digital Mixed I/O Unit−−−
Analog Input Unit
Analog Output Unit
Temperature Input Unit
Heater Burnout Detection Unit−
2-point Units4-point Units8-point Units16-point Units32-point Units
Additional I/O Power Supply UnitNX-PF0630, NX-PF0730
I/O Power Supply Connection Unit
Shield Connection UnitNX-TBX01
NX-PC0010, NX-PC0020,
NX-PC0030
Safety CPU UnitNX-SL3300 *1
Safety Input UnitNX-SIH400 *2, NX-SID800
Safety Output UnitNX-SOH200, NX-SOD400
*1. Safety CPU Unit Ver.1.1 or higher.
*2. Safety Input Unit Ver.1.1 or higher.
UnitModel
8
NX-EIC
Version Information
Depending on the type and model of the Unit, some Units do not have all of the versions given in the corresponding versions. If a Unit does not
have the specified version, support is provided by the oldest available version after the specified version. Refer to the user’s manuals for the
specific Units for the relation between models and versions.
Connection to the NJ/NX-series CPU Unit or NY-series Industrial PC
NX-series CPU Unit or NY-series Industrial PC
EtherNet/IP Coupler UnitCorresponding unit version/version
* The CX-ConfiguratorFDT with version 2.2 or later can be used if it is connected to the peripheral USB port on the EtherNet/IP Coupler Unit.
Unit version of
CJ1W-EIP21
Network Configurator for
EtherNet/IP version
Sysmac Studio
version
Network
Configurator for
EtherNet/IP version
CX-ConfiguratorFDT
version
CX-
ConfiguratorFDT
version
Connection to CS/CJ/CP-series CPU Unit
CS1G/CS1H/CJ1H/CJ1M * CPU Units* Final order entry date for CJ1M:The end of March, 2021
EtherNet/IP Coupler UnitCorresponding unit version/version
ModelUnit version
NX-EIC202
Unit version of CPU
Unit
Ver.1.2
Ver.1.0Ver.1.00 *2Ver.2.2
Ver.3.0Ver.2.1Ver.3.00
Unit version of
CS1W-EIP21/CJ1W-
EIP21
*1. The CX-ConfiguratorFDT with version 2.2 or later can be used if it is connected to the peripheral USB port on the EtherNet/IP Coupler Unit.
*2. You can connect only to the peripheral USB port on the EtherNet/IP Coupler Unit. You cannot connect with any other path.
CJ2H-CPU6/CJ2M-CPU1/CP1H CPU Unit
EtherNet/IP Coupler UnitCorresponding unit version/version
ModelUnit version
NX-EIC202
Unit version of CPU
Unit
Ver.1.2
Ver.1.0Ver.1.00 *2Ver.2.2
Ver.1.0Ver.2.1Ver.3.00
Unit version of
CJ1W-EIP21
*1. The CX-ConfiguratorFDT with version 2.2 or later can be used if it is connected to the peripheral USB port on the EtherNet/IP Coupler Unit.
*2. You can connect only to the peripheral USB port on the EtherNet/IP Coupler Unit. You cannot connect with any other path.
CJ2H-CPU6-EIP CPU Unit
EtherNet/IP Coupler UnitCorresponding unit version/version
ModelUnit version
NX-EIC202
Ver.1.2
Ver.1.0Ver.1.00 *2Ver.2.2
Unit version of CPU
Unit
Ver.1.5Ver.2.1Ver.3.00
*1. The CX-ConfiguratorFDT with version 2.2 or later can be used if it is connected to the peripheral USB port on the EtherNet/IP Coupler Unit.
*2. You can connect only to the peripheral USB port on the EtherNet/IP Coupler Unit. You cannot connect with any other path.
Unit version of
CJ1W-EIP21
Network
Configurator for
EtherNet/IP version
Network
Configurator for
EtherNet/IP version
Network
Configurator for
EtherNet/IP version
NX-IO Configurator
version
Ver.1.00Ver.2.4 *1
NX-IO Configurator
version
Ver.1.00Ver.2.4 *1
NX-IO Configurator
version
Ver.1.00Ver.2.4 *1
ConfiguratorFDT
version
ConfiguratorFDT
version
ConfiguratorFDT
version
CX-
CX-
CX-
CJ2M-CPU3 CPU Unit
EtherNet/IP Coupler UnitCorresponding unit version/version
ModelUnit version
NX-EIC202
Unit version of CPU
Unit
Ver.1.2
Ver.1.0Ver.1.00 *2Ver.2.2
Ver.1.0Ver.2.1Ver.3.21
Unit version of
CJ1W-EIP21
Network
Configurator for
EtherNet/IP version
NX-IO Configurator
version
Ver.1.00Ver.2.4 *1
*1. The CX-ConfiguratorFDT with version 2.2 or later can be used if it is connected to the peripheral USB port on the EtherNet/IP Coupler Unit.
*2. You can connect only to the peripheral USB port on the EtherNet/IP Coupler Unit. You cannot connect with any other path.
CX-
ConfiguratorFDT
version
9
NX-EIC
Connection to the Sysmac Gateway
Sysmac Gateway
EtherNet/IP Coupler UnitCorresponding unit version/version
ModelUnit versionSysmac Gateway version
NX-EIC202
*1. The CX-ConfiguratorFDT with version 2.2 or later can be used if it is connected to the peripheral USB port on the EtherNet/IP Coupler Unit.
*2. You can connect only to the peripheral USB port on the EtherNet/IP Coupler Unit. You cannot connect with any other path.
Ver.1.2
Ver.1.0Ver.1.00 *2Ver.2.2
Ver.1.31Ver.3.50
Network Configurator for
EtherNet/IP version
NX-IO Configurator
version
Ver.1.00Ver.2.4 *1
CX-ConfiguratorFDT
version
10
NX-EIC
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NX-EIC202
NET
(B)
(D)
(E)
(C)
(F)
(C)
(G)
(A)
Eight-terminal Block
(A)
A1
A2
A3
A4
A5
A6
A7
A8
B1
B2
B3
B4
B5
B6
B7
B8
(B)
(C)
External Interface
EtherNet/IP Coupler Unit NX-EIC202
LetterNameFunction
(A)NX bus connector
(B)IndicatorsThe indicators show the current operating status of the Unit and the status of the power supply.
(C)Communications connectorsThese connectors are connected to the communications cables of the EtherNet/IP network.
(D)Peripheral USB portThis port is used to connect to the Sysmac Studio.
(E)Terminal blockThe terminal block is used to connect to the power supply cables and ground wire.
(F)Rotary switches
(G)DIP switch
This connector is used to connect the EtherNet/IP Coupler Unit to the NX Unit on the right of the
Coupler Unit.
The rotary switches are used to set the last octet of the IP address of the EtherNet/IP Coupler
Unit as an EtherNet/IP Slave. The address is set in hexadecimal.
The DIP switch is used to set the default node address of the EtherNet/IP Coupler Unit as an
EtherNet/IP slave.
Terminal Block
SymbolNameFunction
(A)Terminal number indications
(B)Release holesInsert a flat-blade screwdriver into these holes to connect and remove the wires.
(C)Terminal holesThe wires are inserted into these holes.
The terminal numbers (A1 to A8 and B1 to B8) are displayed.
The terminal number indicators are the same regardless of the number of terminals on the
terminal block, as shown above.
11
Applicable Wires
1.6 mm max.
(Terminals other than ground terminals)
2.0 mm max.
(Ground terminals)
2.4 mm max.
(Terminals other than ground terminals)
2.7 mm max.
(Ground terminals)
8 to 10 mm
Conductor length (stripping length)
Using Ferrules
If you use ferrules, attach the twisted wires to them.
Observe the application instructions for your ferrules for the wire stripping length when attaching ferrules.
Always use plated one-pin ferrules. Do not use unplated ferrules or two-pin ferrules.
The applicable ferrules, wires, and crimping tool are given in the following table.
Terminal typesManufacturerFerrule model
AI0,34-80.34 (#22)
AI0,5-8
AI0,5-10
Terminals other
than ground
terminals
Phoenix Contact
AI0,75-8
AI0,75-10
AI1,0-8
AI1,0-10
AI1,5-8
AI1,5-10
Ground
terminals
AI2,5-102.0 *1
H0.14/120.14 (#26)
H0.25/120.25 (#24)
H0.34/120.34 (#22)
H0.5/14
Terminals other
than ground
terminals
Weidmuller
H0.5/16
H0.75/14
H0.75/16
H1.0/14
H1.0/16
H1.5/14
H1.5/16
2
*1. Some AWG 14 wires exceed 2.0 mm
and cannot be used in the screwless clamping terminal block.
Applicable wire
2
(AWG))
(mm
0.5 (#20)
0.75 (#18)
1.0 (#18)
1.5 (#16)
0.5 (#20)
0.75 (#18)
1.0 (#18)
1.5 (#16)
Phoenix Contact (The figure in parentheses is the applicable wire
size.)
CRIMPFOX 6 (0.25 to 6 mm
Weidmueller (The figure in parentheses is the applicable wire size.)
PZ6 Roto (0.14 to 6 mm
2
, AWG 26 to 10)
Crimping tool
2
, AWG 24 to 10)
NX-EIC
When you use any ferrules other than those in the above table, crimp them to the twisted wires so that the following processed dimensions are
achieved.
Using Twisted Wires/Solid Wires
If you use the twisted wires or the solid wires, use the following table to determine the correct wire specifications.
*1. Secure wires to the screwless clamping terminal block. Refer to the Securing Wires in the USER'S MANUAL for how to secure wires.
*2. With the NX-TB@@@1 Terminal Block, use twisted wires to connect the ground terminal. Do not use a solid wire.
Wire type
PossiblePossiblePossible
Possible
Not
Possible
*1
Not
Not
Possible
Possible
Possible *2Possible
*2
Wire size
0.08 to 1.5 mm
AWG28 to 16
2
2.0 mm
Conductor length
(stripping length)
2
8 to 10 mm
9 to 10 mm
<Additional Information> If more than 2 A will flow on the wires, use plated wires or use ferrules.
12
NX-EIC
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NX-EIC202
NET
48.1
80
71
65.2
104.5
100
1.5
1.5
0.55
46
Dimensions(Unit: mm)
● EtherCAT Coupler Unit Only
● With Cables Connected
*1
*2
100 to 120
5.8
*1. This dimension depends on the specifications of the commercially available USB-certified cable. Check the specifications of the USB cable
that is used.
*2. This is the dimension from the back of the Unit to the communications cables.
• 100 mm: When an MPS588-C Connector is used.
• 120 mm: When an XS6G-T421-1 Connector is used.
71
USB cable
Communications cable
13
● End Cover
NX-EIC
12
1.5
100
1.5
71
Related Manuals
Man. NoModelManualApplicationDescription
W536NX-EIC@@@
NX-series EtherNet/IP
Coupler Unit User’s Manual
Learning how to use an NXseries Ether-Net/IP Coupler
Unit and EtherNet/IP Slave
Terminals
Introduces the system, configuration methods, Unit
hardware, setting methods, and functions of
EtherNet/IP Slave Terminals that consist of an
EtherNet/IP Coupler Unit and NX Units.
replacementthereof)thenon-complyingProduct,(ii)repairthenon-complyingProduct,or(iii)repayorcreditBuyeranamountequaltothepurchasepriceofthenon-complyingProduct;providedthatinnoeventshallOmronberesponsibleforwarranty, repair,indemnityoranyother claimsorexpensesregardingtheProductsunlessOmron’sanalysisconfirmsthattheProductswereproperlyhandled,stored,installedandmaintainedandnotsubjecttocontamination,abuse,misuseorinappropriatemodification. Return of any Productsby Buyer must be approved in writing by Omronbeforeshipment. Omron Companies shallnotbeliableforthesuitabilityorunsuitabilityortheresultsfromtheuseofProductsincombinationwithanyelectricalorelectroniccomponents,circuits,systemassembliesoranyothermaterialsorsubstancesorenvironments.Anyadvice,recommendationsorinformationgivenorallyorinwriting,arenottobeconstruedasanamendmentoradditiontotheabovewarranty.Seehttp://www.omron.com/global/orcontactyourOmronrepresentativeforpublishedinformation.
ChangeinSpecifications.Productspecificationsandaccessoriesmaybechangedatanytimebasedonimprovementsandotherreasons.Itisourpracticetochangepartnumberswhenpublishedratingsorfeaturesare changed,orwhensignificant construction changesaremade.However,somespecificationsoftheProductmaybechangedwithoutanynotice. Whenindoubt,specialpartnumbersmaybeassignedtofixorestablishkeyspecificationsforyourapplication.PleaseconsultwithyourOmron’srepresentativeatanytimetoconfirmactualspecificationsofpurchasedProduct.