Lithium BatteryY92S-36
Wire-wrap Terminal (set of two Terminals)Y92S-37
Compact Flush Mounting Bracket (See note.)Y92F-35
Flush Mounting Adapter26 mm × 45.3 mmY92F-75
Note: The New H7E models are supplied with a Y92F-34 Mounting Bracket.
30 Hz ←→ 1 kHz
(switchable)
(switchable)
7-segment LCD with
backlight
7-segment LCDH7EC-NVH7EC-NV-B
7-segment LCDH7EC-NH7EC-N-B
27.5 mm × 52.5 mmY92F-76
24.8 mm × 48.8 mmY92F-77B
H7EC-NV-HH7EC-NV-BH
Self-powered Total CounterH7ECC-9
Specifications
■ General
ItemH7EC-NV-@
Operating modeUp type
Mounting methodFlush mounting
External connectionsScrew terminals, optional Wire-wrap Terminals (see note 1)
ResetExternal/Manual reset
Number of digits8
Count inputPNP/NPN universal DC voltage in-
put
Display7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 2)
Max. counting speed30 Hz/1 kHz20 Hz30 Hz/1 kHz
Case colorLight gray or black (-B models)
AttachmentWaterproof packing, flush mounting bracket
Approved standardUL863, CSA C22.2 No.14, Lloyds
Conforms to EN61010-1/IEC61010-1 (Pollution degree2/overvoltage category III)
Conforms to VDE0106/P100
Note: 1. Separately ordered Wire-wrap Terminals (Y92S-37) are required.
2. Only PNP/NPN universal DC voltage input models (-H models) have a backlight.
H7EC-NV-@H
AC/DC multi-voltage inputNo-voltage input
H7EC-NFV-@H7EC-N-@
■ Ratings
ItemH7EC-NV-@
Supply voltageBacklight model: 24 VDC (0.3 W max.)
Count inputHigh (logic) level: 4.5 to 30 VDC
Reset inputNo voltage input
Max. counting
speed (see note)
Minimum signal
width
Reset systemExternal reset and manual reset: Minimum signal width of 20 ms
Terminal screw
tightening torque
Ambient tempera-
ture
Ambient humidity Operating 25% to 85%
Note: ON/OFF ratio 1:1
(only for backlight)
No-backlight model: Not required
(powered by built-in battery)
Static immunity±8 kV (malfunction)
Vibration resistance Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Shock resistance
EMC(EMI)EN61326
Degree of protection Front panel:IP66, NEMA4
Weight (see note)No-backlight model: Approx. 60 g
Note: Weight includes waterproof packing and flush mounting bracket.
current-carrying metal parts and exposed non-current-carrying metal
parts, and between the backlight power
supply terminal and count input terminals/reset terminals for backlight models
current-carrying metal parts and exposed non-current-carrying metal parts
and between the backlight power supply terminal and count input terminals/
reset terminals for backlight models
4.5 kV between current-carrying terminal and exposed non-current-carrying
metal parts
±600 V (Between count input terminals/
Between reset terminals)
±480 V (Between the backlight power
supply terminals for backlight models)
Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
Malfunction: 200 m/s
Destruction: 300 m/s
Emission Enclosure:EN55011 Group 1 class B
(EMS)EN61326
Immunity ESD:EN61000-4-2: 4 kV contact discharge (level 2)
Immunity RF-interference from AM Radio Waves:
Immunity RF-interference from Pulse-modulated Radio Waves:
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:EN61000-4-4: 2 kV power line (level 3)
Terminal block: IP20
Backlight model: Approx. 65 g
H7EC-NV-@H
2
3 times each in 6 directions
2
3 times each in 6 directions
100 MΩ min. (at 500 VDC) between
current-carrying metal parts and exposed non-current-carrying metal parts
and between count input terminals and
reset terminals
3,700 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and exposed non-current-carrying metal parts
2,200 VAC, 50/60 Hz for 1 min between
reset terminals and exposed non-current-carrying metal parts and between
count input terminals and reset terminals
4.5 kV between current-carrying terminal and exposed non-current-carrying
metal parts
3 kV between input terminals and reset
terminals
±1.5 kV (Between count input terminals)
±500 V (Between reset terminals)
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3)
Approx. 60 gApprox. 60 g
H7EC-NFV-@H7EC-N-@
100 MΩ min. (at 500 VDC) between
current-carrying metal parts and exposed non-current-carrying metal parts
1,000 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and exposed non-current-carrying metal parts
4.5 kV between current-carrying terminal and exposed non-current-carrying
metal parts
±500 V (Between count input terminals/
Between reset terminals)
8 kV air discharge (level 3)
2 kV I/O signal line (level 4)
Counters
■ Reference Value
ItemValueNote
Battery life7 years min. with continuous input at 25°C
(lithium battery)
The battery life is calculated according to the conditions in the left column and
therefore is not a guaranteed value. Use these value as reference for maintenance or replacement.
Self-powered Total CounterH7ECC-11
Connections
■ Terminal Arrangement
Bottom view: View of the Total Counter rotated horizontally 180°
Backlight ModelNo-backlight Model
Backlight
24 VDC
Count
input
Reset
input
Count
input
Reset
input
■ Connections
H7EC Total Counter
PNP/NPN Universal DC Voltage Input Model With Backlight
1. Contact Input (Input by a Relay or Switch Contact)2. Solid-state Input
Open collector of a
Relay
Input
or Switchor Switch
Backlight
24 VDC
Reset
Relay
PNP transistor
or Open collector of an
NPN transistor
Input
Backlight
24 VDC*
Reset
Open collector of a
PNP transistor
or Open collector of an
NPN transistor
Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are func-
tionally isolated.
2. Select input transistors according to the following:
Dielectric strength of the collector ≥ 50 V
Leakage current < 100 µA
Note: *Recommended Power supply; eg. OMRON S8VS
C-12Self-powered Total Counter H7EC
PNP/NPN Universal DC Voltage Input Model Without Backlight
1. Contact Input (Input by a Relay or Switch Contact)
Relay
Input
or Switchor Switch
Reset
Relay
No-voltage Input Model
1. Contact Input (Input by a Relay or Switch Contact)
Relay
or Switchor Switch
InputReset
Ter minals 2 and 4 are
internally connected.
Relay
Counters
2. Solid-state Input
Open collector of a
PNP transistor
Input
or Open collector of an
NPN transistor
Open collector of a
PNP transistor
Reset
or Open collector of an
NPN transistor
Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are
functionally isolated.
2. Select input transistors according to the following:
Dielectric strength of the collector ≥ 50 V
Leakage current < 100 µA
AC/DC Multi-voltage Input Model
Relay
Note: Use Relays and Switches that have high contact reli-
ability because the current flowing from terminals 1 or
3 is small. It is recommended that OMRON's G3TAIA/ID be used as the SSR.
2. Solid-state Input
(Open Collector Input of an NPN Transistor)
Open collector of an
NPN transistor
Input
Ter minals 2 and 4 are
internally connected.
Reset
Open collector of an
NPN transistor
or Switch
Note: 1. Residual voltage in the output section of Proximity
Sensors or Photoelectric Sensors becomes less than
0.5 V because the current flowing from terminals 1 or 3
is small thus allowing easy connection.
2. Select input transistors according to the following:
Dielectric strength of the collector ≥ 50 V
Leakage current < 1 µA
or Switch
Input
Reset
Relay
or Switch
or Open collector of
an NPN transistor
Note: Select input transistors according to the following:
Dielectric strength of the collector ≥ 50 V
Leakage current < 1 µA
Self-powered Total CounterH7ECC-13
Operation
■ Operating Modes
H7EC Total Counter
Incrementing Operation
(Up)
Reset
Count input
Counting display values
Nomenclature
Full-scale
(Full-scale
1)
−
Front view
Counting speed switch
For all models except for H7EC-NFV-@.
If the counting speed setting is changed,
the present value will not be held and so
press the Reset Key on the front panel.
Setting
(see note)
Front panel
Ter minal block
Counting speed
Concave
side
(default setting)
Concave
side
30 Hz
1 kHz
Note: Perform switch setting before mounting to a control panel.
H7EC
Bottom view
Reset Key
Reset the count value. Not operable
under key-protect.
Key-protect Switch
The Reset Key is not operable while the
key-protect switch is set to ON.
Setting
(see note)
Front panel
Concave
side
Concave
side
Ter minal block
Key-protect
OFF
(default setting)
ON
C-14Self-powered Total Counter H7EC
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H7EC-N
M3.5 terminal screw
Counters
Panel Cutout
Separate mounting
40 min.
Dimensions with Flush Mounting Bracket
Dense mounting
• When mounting, insert the Counter into
the cutout, insert the adapter from the
back and push in the Counter while
making the gap between the front panel
and the cutout panel as small as
possible. Use screws to secure the
Counter. If waterproofing is desired,
insert the waterproof packing.
• When several Counters are installed,
ensure that the ambient temperature
will not exceed specifications.
• The appropriate thickness of the panel
is 1 to 5 mm.
Note: A Compact Flush Mounting Bracket (Y92F-35) can also be used. Refer to Accessories for details.
+0.5
45
0
+0.5
22.2
0
(48 Units − 2.5)
Waterproofing is not possible for
dense mounting
+1.0
0
22.2
+0.5
0
Self-powered Total CounterH7ECC-15
C-16Self-powered Total Counter H7EC
Self-powered Time Counter
H7ET
• Seven digits, time range 0 to 3999d23.9h.
• Dual time range: 999999.9 ←→ 3999d23.9h or
999h59m59s ←→ 9999h59.9m
Model Number Structure
■ Model Number Legend
H7ET - N -
1234
1. Count Input
None: No-voltage input
V: PNP/NPN universal DC voltage input
FV: AC/DC multi-voltage input