Multifunction Preset Counter H7CX-A 5
■Ratings (contd.)
Note: 1. Permissible ripple: 20% (p-p) max.
2. The display is lit only when the power is ON.
3. Only when the following modes are selected.
- Input mode: command, individual, or quadrature; output mode: K-2, D, L, or H
- Dual count calculating mode: SUB; output mode: K-2, D, L, or H in dual counter operation
Item H7CX-A4W@ H7CX-AW@ H7CX-AU@
Classification Preset counter Preset counter/tachometer
Supported configuratio ns 1-stage counter, 2-stage counter, 1-stage
counter with total counter , 1-stage count er
with batch counter, dual counter (addition
only) (selectable)
1-stage counter, 2-stage counter, 1-stage counter with total counter, 1-stage counter with batch
counter, dual counter (addition/subtraction), tachometer (selectable)
Rated supply voltage (See note 1.) 100 to 240 VAC (50/60 Hz),
12 to 24 VDC
100 to 240 VAC (50/60 Hz),
24 VAC (50/60 Hz)/12 to 24VDC,
12 to 24 VDC
100 to 240 VAC (50/60 Hz),
24 VAC (50/60 Hz)/12 to 24VDC
Operating voltage range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Power consumption Approx. 9.2 VA at 264 VAC
Approx. 7.2 VA at 26.4 VAC
Approx. 3.7 W at 12 VDC
Mounting method Flush mounting
External connections Screw terminals
Terminal screw tightening torque 0.5 N·m max.
Display (See note 2.) 7-segment, negative transmissive LCD
PV 11.5-mm-high characters, red or green
(programmable)
9-mm-high characters, red or green (programmable)
SV 6-mm-high characters, green
Digits 4 digits (−999 to 9,999)
SV range: 0 to 9,999
6 digits (−99,999 to 999,999 or 0 to 999,999 when using as Tachometer)
SV range: −99,999 to 999,999 (See note 3.) or 0 to 999,999
Input signals CP1, CP2, reset 1, and reset 2
Input method No-voltage input/voltage input (switchable)
No-voltage input
ON impedance: 1 kΩ max. (Leakage current: 5 to 20 mA at 0 Ω)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Voltage input
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
Counter Max. counting speed 30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2
Input mode Increment, decrement, command, individual, and quadrature
Reset input Minimum reset input signal width: 1 or 20 ms (selectable), common setting for all inputs
Reset system External, manual, and automatic reset (internal according to C, R, P, and Q mode operation)
Output modes N, F, C, R, K-1, P, Q, A N, F, C, R, K-1, P, Q, A, K-2, D, L, H
One-shot output time 0.01 to 99.99 s
Tachometer Pulse measurement
method
--- Periodic measurement (Sampling period: 200 ms)
Max. counting speed --- 30 Hz or 10 kHz (selectable)
Measuring ran ges --- 30 Hz: 0.01 to 30.00 Hz
10 kHz: 0.01 Hz to 10 kHz
Measuring accuracy --- ±0.1% FS ±1 digit max. (at 23 ±5°C)
Output modes --- HI-LO, AREA, HI-HI, LO-LO
Auto-zero time --- 0.1 to 99.9 s
Startup time --- 0.0 to 99.9 s
Average processing --- OFF/2/4/8 times
Output type H7CX-A4W/-AW/-AWD1: SPDT (OUT2) and SPST-NO (OUT1)
H7CX-A4WSD/-AWS/-AWSD/-AWSD1: 2 transistors
H7CX-AU/-AUD1: SPDT and 1 transistor
H7CX-AUSD1: 2 transistors
(Output allocation possible)
Control output Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1)
Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
Transistor output: NPN open collector, 100 mA at 30 VDC
Residual voltage: 1.5 VDC max. (approx. 1 V)
Leakage current: 0.1 mA max.
NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120VAC, 1/3 HP 3-A resistive load at 240 VAC
External power supply 12 VDC (±10%), 100 mA (except for H7CX-A@D models)
Refer to Safety Precautions (page 60) for details.
Key protection Yes
Prescaling function Yes (0.001 to 9.999) Yes (0.001 to 99.999)
Decimal point adjustment Yes (rightmost 3 digits)
Sensor waiting time 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Ambient temperature Operating: −10 to 55°C (−10 to 50°C if counters are mounted side by side) (with no icing or condensation)
Storage: −25 to 65°C (with no icing or condensation)
Ambient humidity 25% to 85%
Case color Black (N1.5), light gray (Munsell 5Y7/1, produced upon request)
Attachments Waterproof packing, flush moun ting adapt-erWaterproof packing, flush mounting adapter, labels for counter/tachometer DIP switch settings