OMRON H7CX Technical data

查询H7CX-A供应商
Multifunction Preset Counter
H7CX
• Highly visible display with backlit negative transmissive LCD.
• Intuitive setting enabled using ergonomic up/down digit keys (4­digit models) and DIP switch.
• Configurable as 1-stage counter, 2-stage counter, total and pre­set counter, batch counter, dual counter, or tachometer. (Config­urability varies with model.)
• PNP/NPN switchable input.
• Finger-safe terminals (screw terminal block models).
• Meets a variety of mounting requirements: Screw terminal block models, and pin-style terminal models.
• NEMA4/IP66 compliance.
• Six-language instruction manual.
Contents
Model Number Structure.............................................................. C-88
Ordering Information.................................................................... C-88
Specifications............................................................................... C-89
Connections................................................................................. C-93
Nomenclature .............................................................................. C-98
Dimensions .................................................................................. C-99
Precautions.................................................................................. C-103
Operating Procedures.................................................................. C-106
Setting Procedure Guide ....................................................... C-106
Operating Procedures (Counter Function) ............................ C-107
Operating Procedures (Tachometer Function) ...................... C-118
Operation in Configuration Selection Mode........................... C-124
Additional Information .................................................................. C-125
Counters
Multifunction Preset Counter
H7CX
C-87
Model Number Structure
Model Number Legend
H7CX-A@@@@@@
1 2 3 4 5 6
1. External connection
None: Screw terminals 11: 11-pin socket
2. No. of digits
None: 6 digits 4: 4 digits
3. Stage setting
None: 1-stage setting U: Factory-set to 1-stage setting W: Factory-set to 2-stage setting
Ordering Information
List of Models
4. Output type
None: Contact output or contact and transistor in combination S: Transistor output
5. Supply voltage/external power supply
None: 100 to 240 VAC at 50/60 Hz with 12 VDC power supply D: 12 to 24 VDC without external power supply D1: 12 to 24 VDC or 24 VAC at 50/60 Hz with 12 VDC power
supply
6. Case color
None: Black G: Light gray (Munsell 5Y7/1): Produced upon request.
Supported configurations
Sensor
power
supply
12 VDC Contact output 100 to 240 VAC H7CX-A11 H7CX-A114 H7CX-A H7CX-A4 --- H7CX-AW H7CX-A4W
None Contact output 12 to 24 VDC --- --- H7CX-AD H7CX-A4D --- --- ---
Note:
Flush Mounting Adapter (See note 1.) Y92F-30
Waterproof Packing (See note 1.) Y92S-29
Track Mounting/Front Connecting Socket
Back Connecting Socket 11-pin P3GA-11
Hard Cover Y92A-48
Soft Cover Y92A-48F1
Mounting Track 50 cm (l) × 7.3 mm (t) PFP-50N
End Plate PFP-M
Spacer PFP-S
Note: 1.
Output type Supply voltage 11-pin socket Screw terminal
12 to 24 VDC/ 24 VAC
Contact and transistor output
Transistor output 100 to 240 VAC H7CX-A11S H7CX-A114S H7CX-AS H7CX-A4S --- H7CX-AWS ---
Transistor output --- --- H7CX-ASD H7CX-A4SD --- H7CX-AWSD H7CX-A4WSD
100 to 240 VAC --- --- --- --- H7CX-AU --- ---
12 to 24 VDC/ 24 VAC
12 to 24 VDC/ 24 VAC
Can be used as a 2-stage counter. In this case, each output can be flexibly allocated to either stage 1 or 2.
Accessories (Order Separately)
Name Models
11-pin P2CF-11
11-pin, finger-safe type P2CF-11-E
11-pin, finger-safe type P3GA-11 with Y92A-48G (See note 2.)
1 m (l) × 7.3 mm (t) PFP-100N
1 m (l) × 16 mm (t) PFP-100N2
Supplied with screw-terminal models (i.e., excluding H7CX-A11@/-A114@ models). Y92A-48G is a finger-safe terminal cover attached to the P3GA-11 Socket.
2.
1-stage counter
1-stage counter with total counter
1-stage 1-stage
6 digits 4 digits 6 digits 4 digits 6 digits 6 digits 4 digits
H7CX-A11
H7CX-A11D1 H7CX-A114D1 --- --- --- H7CX-AWD1 ---
--- --- --- --- H7CX-AUD1 --- ---
H7CX-A11SD1 --- --- --- H7CX-AUSD1 H7CX-AWSD1 ---
H7CX-A114@H7CX-A@H7CX-A4@H7CX-AU
@
1-stage counter
2-stage counter
1-stage counter with total counter
1-stage counter with batch counter
Dual counter (addition/subtrac­tion)
Tachometer
(See note.)
H7CX-AW
@
1-stage counter
2-stage counter
1-stage counter with total counter
1-stage counter with batch counter
Dual counter (addi­tion only)
2-stage
@
H7CX-A4W
@
C-88
Multifunction Preset Counter
H7CX
Specifications
Ratings
Item H7CX-A4
Classification
Supported configurations
Rated supply voltage (See note 1.)
Operating voltage range
Power consumption
Mounting method
External connections
Terminal screw tightening torque
Display
PV
SV
Digits
Max. counting speed
Input modes
Input signals
Input method
Reset input
Reset system
Output modes
One-shot output time
Output type
Control output
External power supply
Key protection
Prescaling function
Decimal point adjustment
Sensor waiting time
Memory backup
Ambient temperature
Ambient humidity
Case color
Attachments
Note: 1.
Permissible ripple: 20% (p-p) max. Only when the following modes are selected.
2.
Input mode: command, individual, or quadrature; output mode: K-2, D, or L
@
Preset counter
1-stage counter, 1-stage counter with total counter (selectable)
100 to 240 VAC (50/60 Hz), 12 to 24 VDC 100 to 240 VAC (50/60 Hz)
85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Approx. 9.2 VA at 264 VAC Approx. 7.2 VA at 26.4 VAC Approx. 3.7 W at 12 VDC
Flush mounting Flush mounting, surface mounting, or DIN track mounting
Screw terminals 11-pin socket
0.5 N·m max. ---
7-segment, negative transmissive LCD;
11.5-mm-high characters, red or green (programmable)
6-mm-high characters, green
4 digits (−999 to 9,999) SV range: 0 to 9,999
30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2
Increment, decrement, command, individual, and quadrature
CP1, CP2, reset, and total reset
No-voltage input/voltage input (switchable) No-voltage input ON impedance: 1 kΩ max. (Leakage current: 5 to 20 mA at 0 Ω) ON residual voltage: 3 V max. OFF impedance: 100 kΩ min. Voltage input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
Minimum reset input signal width: 1 or 20 ms (selectable), common setting for all inputs
External, manual, and automatic reset (internal according to C, R, P, and Q mode operation)
N, F, C, R, K-1, P, Q, A N, F, C, R, K-1, P, Q, A,
0.01 to 99.99 s
Contact type: SPDT Transistor type: 1 transistor
Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1) Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) Transistor output: NPN open collector, 100 mA at 30 VDC
NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120 VAC, 1/3 HP 3-A resistive load at 240 VAC
12 VDC (±10%), 100 mA (except for H7CX-A@D models) Refer to
Precautions
Ye s
Yes (0.001 to 9.999) Yes (0.001 to 99.999) Yes (0.001 to 9.999) Yes (0.001 to 99.999)
Yes (rightmost 3 digits)
250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating:−10 to 55°C (−10 to 50°C if counters are mounted side by side) (with no icing or condensation) Storage:−25 to 65°C (with no icing or condensation)
25% to 85%
Black (N1.5), light gray (Munsell 5Y7/1, produced upon request)
Waterproof packing, flush mounting adapter None
for details.
9-mm-high characters, red or green (programmable)
6 digits (−99,999 to 999,999) SV range: −99,999 to 999,999 (See note 2.) or 0 to 999,999
K-2, D, L
Residual voltage: 1.5 VDC max. (approx. 1 V) Leakage current: 0.1 mA max.
H7CX-A
@
H7CX-A114
24 VAC (50/60 Hz)/12 to 24 VDC
11.5-mm-high characters, red 9-mm-high characters, red
4 digits (−999 to 9,999) SV range: 0 to 9,999
N, F, C, R, K-1, P, Q, A N, F, C, R, K-1, P, Q, A,
@
6 digits (−99,999 to 999,999) SV range: −99,999 to 999,999 (See note 2.) or 0 to 999,999
K-2, D, L
H7CX-A11
@
Counters
Multifunction Preset Counter
H7CX
C-89
Ratings (contd.)
Classification
Supported configurations
Rated supply voltage (See note 1.)
Operating voltage range
Power consumption
Mounting method
External connections
Terminal screw tightening torque
Display
Digits
Input signals
Input method
Counter Max. counting speed
Tachometer Pulse measurement
Output type
Control output
External power supply
Key protection
Prescaling function
Decimal point adjustment
Sensor waiting time
Memory backup
Ambient temperature
Ambient humidity
Case color
Attachments
Item H7CX-A4W@ H7CX-AW@ H7CX-AU@
PV
SV
Input mode
Reset input
Reset system
Output modes
One-shot output time
method
Max. counting speed
Measuring ranges
Measuring accuracy
Output modes
Auto-zero time
Startup time
Average processing
Preset counter Preset counter/tachometer
1-stage counter, 2-stage counter, 1-stage counter with total counter, 1-stage counter with batch counter, dual counter (addition only) (selectable)
100 to 240 VAC (50/60 Hz), 12 to 24 VDC
85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Approx. 9.2 VA at 264 VAC Approx. 7.2 VA at 26.4 VAC Approx. 3.7 W at 12 VDC
Flush mounting
Screw terminals
0.5 N·m max.
7-segment, negative transmissive LCD
11.5-mm-high characters, red or green (programmable)
6-mm-high characters, green
4 digits (−999 to 9,999) SV range: 0 to 9,999
CP1, CP2, reset 1, and reset 2
No-voltage input/voltage input (switchable) No-voltage input ON impedance: 1 kΩ max. (Leakage current: 5 to 20 mA at 0 Ω) ON residual voltage: 3 V max. OFF impedance: 100 kΩ min. Voltage input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2
Increment, decrement, command, individual, and quadrature
Minimum reset input signal width: 1 or 20 ms (selectable), common setting for all inputs
External, manual, and automatic reset (internal according to C, R, P, and Q mode operation)
N, F, C, R, K-1, P, Q, A N, F, C, R, K-1, P, Q, A, K-2, D, L, H
0.01 to 99.99 s
--- Periodic measurement (Sampling period: 200 ms)
--- 30 Hz or 10 kHz (selectable)
--- 30 Hz: 0.01 to 30.00 Hz
---
--- HI-LO, AREA, HI-HI, LO-LO
--- 0.1 to 99.9 s
--- 0.0 to 99.9 s
--- OFF/2/4/8 times
H7CX-A4W/-AW/-AWD1: SPDT (OUT2) and SPST-NO (OUT1) H7CX-A4WSD/-AWS/-AWSD/-AWSD1: 2 transistors
Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1) Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) Transistor output: NPN open collector, 100 mA at 30 VDC
NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120 VAC, 1/3 HP 3-A resistive load at 240 VAC
12 VDC (±10%) 100 mA (except for H7CX-A@D models) Refer to
Precautions
Ye s
Yes (0.001 to 9.999) Yes (0.001 to 99.999)
Yes (rightmost 3 digits)
250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating:−10 to 55°C (−10 to 50°C if counters are mounted side by side) (with no icing or condensation) Storage:−25 to 65°C (with no icing or condensation)
25% to 85%
Black (N1.5), light gray (Munsell 5Y7/1, produced upon request)
Waterproof packing, flush mounting adapt-erWaterproof packing, flush mounting adapter, labels for counter/tachometer DIP switch settings
Residual voltage: 1.5 VDC max. (approx. 1 V) Leakage current: 0.1 mA max.
for details.
1-stage counter, 2-stage counter, 1-stage counter with total counter, 1-stage counter with batch counter, dual counter (addition/subtraction), tachometer (selectable)
100 to 240 VAC (50/60 Hz), 24 VAC (50/60 Hz)/12 to 24 VDC, 12 to 24 VDC
9-mm-high characters, red or green (programmable)
6 digits (−99,999 to 999,999 or 0 to 999,999 when using as Tachometer) SV range: −99,999 to 999,999 (See note 2.) or 0 to 999,999
10 kHz: 0.01 Hz to 10 kHz
±
0.1% FS ±1 digit max. (at 23 ±5°C)
100 to 240 VAC (50/60 Hz), 24 VAC (50/60 Hz)/12 to 24 VDC
H7CX-AU/-AUD1: SPDT and 1 transistor H7CX-AUSD1: 2 transistors (Output allocation possible)
Note: 1.
C-90
Permissible ripple: 20% (p-p) max. Only when the following modes are selected.
2.
- Input mode: command, individual, or quadrature; output mode: K-2, D, L, or H
- Dual count calculating mode: SUB; output mode: K-2, D, L, or H in dual counter operation
Multifunction Preset Counter
H7CX
Characteristics
item H7CX
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Life expectancy
Approved safety standards (See note 1.)
EMC
Degree of protection
Weight
Note: 1.
To meet UL listing requirements with the H7CX-A11@ models, an OMRON P2CF-11-@ or P3GA-11 Socket must be mounted on the H7CX. Otherwise, H7CX-A11@ models are considered to meet UL508 recognition requirements.
A waterproof packing is necessary to ensure IP66 waterproofing between the H7CX and installation panel.
2.
100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts, and be­tween non-continuous contacts
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts 2,000 VAC (for 100 to 240 VAC), 50/60 Hz for 1 min between power supply and input circuit (1,000 VAC for 24 VAC/ 12 to 24 VDC) 1,000 VAC (for H7CX-@SD/-@SD1), 50/60 Hz for 1 min between control output, power supply, and input circuit (2,000 VAC for models other than H7CX-@SD/-@SD1) 1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12 to 24 VDC and 12 to 24 VDC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC,
1.5 kV for 24 VAC/12 to 24 VDC and 12 to 24 VDC
±
1.5 kV (between power terminals) for 100 to 240 VAC and 24 VAC/12 to 24 VDC, ±480 V for 12 to 24 VDC
±
600 V (between input terminals)
Square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Destruction: 15 kV Malfunction: 8 kV
Destruction: 10 to 55 Hz with 0.75-mm single amplitude, four cycles each in three directions (8 minutes per cycle) Malfunction: 10 to 55 Hz with 0.35-mm single amplitude, four cycles each in three directions (8 minutes per cycle)
2
Destruction: 294 m/s Malfunction: 98 m/s
Mechanical: 10,000,000 operations min. Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load)
See
UL508/Listing, CSA C22.2 No. 14, conforms to EN61010-1 (Pollution degree 2/overvoltage category II) Conforms to VDE0106/P100 (finger protection).
(EMI) EN61326 Emission Enclosure: EN55011 Group 1 class A Emission AC mains: EN55011 Group 1 class A
(EMS) EN61326 Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2)
Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3);
Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2);
Immunity Voltage Dip/Interruption EN61000-4-11: 0.5 cycle, 100% (rated voltage)
Panel surface: IP66 and NEMA Type 4 (indoors) (See note 2.)
Approx. 140 g
each in three directions
2
each in three directions
Life-test Curve
on page 92.
8 kV air discharge (level 3)
10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)
1 kV I/O signal-line (level 4)
2 kV line to ground (power and output lines) (level 3)
Counters
Multifunction Preset Counter
H7CX
C-91
Life-test Curve (Reference Values)
Resistive Load Inductive Load
1,000
)
3
700
500
1,000
)
700
3
500
300
No. of operations (×10
250 VAC (cosφ=1)
100
70
50
01 2 3
30 VDC (cosφ=1)
Load current (A)
4
300
30 VDC (L/R=7 ms)
No. of operations (×10
100
250 VAC cosφ=0.4
70
50
01 2 3
4
Load current (A)
Reference: A current of 0.15 A max. can be switched at 125 VDC (cosφ=1) and current of 0.1 A max. can be switched if L/R=7 ms. In both cases, a life of 100,000 operations can be expected.
Inrush Current (Reference Values)
The minimum applicable load is 10 mA at 5 VDC (failure level: P).
Model Voltage Applied voltage Inrush current (peak value) Time
H7CX-A11/-AW 100 to 240 VAC 264 VAC 5.8 A 0.7 ms
H7CX-A11D1/-AWD1 24 VAC/12 to 24 VDC 26.4 VAC 10.4 A 1.2 ms
H7CX-AD 12 to 24 VDC 26.4 VDC 6.0 A 1.2 ms
C-92
Multifunction Preset Counter
H7CX
Connections
Block Diagram
(Basic
Output circuit
(Basic insulation)
Input circuit
All models except for H7CX-@D (models with 12 to 24-VDC power supplies) have basic insulation.
Note:
I/O Functions
Using as a Counter
insulation) Power supply
Internal control circuit
circuit
(See note.)
Display circuit
Key switch circuit
Counters
Inputs CP1, CP2
Reset or Reset 1
Total Reset or Reset 2 (See note 2.)
Outputs OUT1, OUT2
Note: 1.
In increment mode or increment/decrement mode, the present value returns to 0; in decrement mode, the present value returns to the set value with 1-stage models, and returns to set value 2 with 2-stage models.
The reset indicator will not be lit when the total reset or reset 2 input is ON.
2.
In general (except for dual counter mode) Reads counting signals Increment, decrement, command, individual, and quadrature inputs accepted.
When used as a dual counter
Reads CP1 count signals with CP1 input and CP2 count signals with CP2 input. Increment signals can be input.
In general (except for dual counter mode) Resets present value and outputs (OUT2 when using the batch counter). (See note 1.) Counting cannot be performed during reset/reset 1 input. The reset indicator is lit during reset input.
When used as a dual counter
Resets the CP1 present value (to 0). Counting for CP1 input cannot be performed during reset 1 input. The reset indicator is lit during reset 1 input.
When used as a 1-stage/2-stage counter
Does not operate (Not used). When used as a total and preset counter
Resets the total count value. Holds the total count value at 0 during total reset input.
When used as a batch counter
Resets the batch count value and batch output (OUT1). Holds the batch count value at 0 during reset 2 input.
When used as a dual counter
Resets the CP2 present value. Counting for CP2 input cannot be performed during reset 2 input.
Outputs take place according to designated output mode when corresponding preset is reached.
Using as a Tachometer
Inputs CP1, CP2
Reset 1, Reset 2
Outputs OUT1, OUT2
Reads counting signals. (CP2 input is not used.)
Holds the measurement value and outputs. (Reset 2 input is not used.) The reset indicator is lit during hold.
Outputs signals according to the specified output mode when a set value is reached.
Multifunction Preset Counter
H7CX
C-93
Terminal Arrangement
Confirm that the power supply meets specifications before use.
H7CX-A/-A4 1-stage Contact Output
CP2
Reset
0 V
(−)
Sensor, etc.
(+)
External power supply
678910
12 VDC
11 12 13
1234
Unused Unused
OUT
H7CX-AS/-A4S 1-stage Transistor Output
CP2
Reset
0 V
()
Sensor, etc.
(+)
External power supply
678910
12 VDC
11 12 13
Unused Unused
CP1
CP1
Total reset
5
Total reset
H7CX-AD/-A4D 1-stage Contact Output
0 V
678910
Unused Unused Unused
11 12 13
1234
(+)(−)
Total reset
5
OUT
CP2
CP1
Reset
Note: Terminals 1 and 6 are connected internally.
H7CX-ASD/-A4SD 1-stage Transistor Output
CP2
CP1
Reset
0 V
678910
Unused Unused Unused
11 12 13
Total reset
12345
OUT
H7CX-A11/-A114/-A11D1/-A114D1 1-stage Contact Output
Reset
CP1
CP2
0 V
5
4
3
2
1
()
Total reset
()
Sensor, etc.
Note:
12 VDC
(+)
External power supply
Do not connect unused terminals as relay terminals.
6
11
7
10
(+)
Internal circuit
8
9
OUT
12345
OUT
(+)
()
Note: Terminals 1 and 6 are connected internally.
H7CX-A11S/-A114S/-A11SD1 1-stage Transistor Output
Reset
CP1
CP2
Total reset
()
Sensor, etc.
12 VDC
(+)
External power supply
0 V
5
4
3
2
1
()
6
7
11
(+)
Internal circuit
8
9
10
OUT
C-94
Multifunction Preset Counter
H7CX
H7CX-AW/-A4W/-AWD1 2-stage Contact Output
Reset 1
0 V
()
Sensor, etc.
(+)
External power supply
678910
12 VDC
11 12 13
12345
()
(+)
CP2
OUT2
CP1
Reset 2
OUT1
H7CX-AWS/-AWSD1 2-stage Transistor Output
CP2
Reset 1
0 V
()
Sensor, etc.
(+)
External power supply
678910
12 VDC
11 12 13
12345
OUT2
(+)()
CP1
Reset 2
OUT1
Counters
H7CX-AWSD/-A4WSD 2-stage Transistor Output
CP2
CP1
Reset 1
0 V
678910
Unused
11 12 13
12345
(+)()
Reset 2
OUT1
OUT2
Note: 1. Terminals 1 and 6 are connected internally.
2. Do not connect unused terminals as relay terminals.
H7CX-AU/-AUD1 1-stage Contact, 1-stage Transistor Output
CP2
CP1
()
Sensor, etc.
(+)
12 VDC
External power supply
Reset 1
0 V
678910
11 12 13
Reset 2
OUT1 or 2
H7CX-AUSD1 1 or 2-stage Transistor Output
CP2
CP1
Reset 1
0 V
()
Sensor, etc.
(+)
External power supply
678910
12 VDC
11 12 13
12345
OUT 1 or 2
(+)()
Note: Each output can be flexibly allocated to
either stage 1 or 2 in function selection mode.
Reset 2
OUT1 or 2
12345
OUT 1 or 2
(+)()
Note: Each output can be flexibly allocated to either
stage 1 or 2 by setting in function selection mode.
Multifunction Preset Counter
H7CX
C-95
Input Circuits
p
p
CP1, CP2, Reset/Reset 1, and Total Reset/Reset 2 Input
+14 V
1 k
IN
The circuit shown above is for no-voltage input (NPN input).
Note:
Input Connections
Internal circuit
The inputs of the H7CX are no-voltage (short-circuit or open) inputs or voltage inputs.
No-voltage Inputs (NPN Inputs)
Open Collector
PLC or sensor
0 V
Input
Reset/reset 1 input
CP2 input
H7CX-A@ H7CX-A11@
Operates when the transistor turns ON.
6 7 8 9
3 7 5 6 4
CP1 input
Total reset/reset 2 input
10
Voltage Output
Sensor
0 V
Input
H7CX-A@ H7CX-A11@
Operates when the transistor turns ON.
6 7 8 9
3 7 5 6104
No-voltage Input Signal Levels
No-contact input Short-circuit level
Transistor ON Residual voltage: 3 V max. Impedance when ON: 1 KΩ max. (The leakage current is 5 to 20 mA when the impedance is 0 Ω.)
Open level Transistor OFF
Impedance when OFF: 100 KΩ min.
Contact input Use contact which can adequately switch
5 mA at 10 V. Maximum applicable voltage: 30 VDC max.
Reset/reset 1 input
CP2 input
CP1 input
Total reset/reset 2 input
Contact Input
0 V
Input
Reset/reset 1 input
CP2 input
H7CX-A@ H7CX-A11@
Operates when the contact turns ON.
6 7 8 9
3 7 5 6104
ut
CP1 input
Total reset/reset 2 in
DC Two-wire Sensor
0 V
Input
Reset/reset 1 input
CP2 input
CP1 input
H7CX-A@ H7CX-A11@
Operates when the transistor turns ON.
Applicable Two-wire Sensor
Leakage current:1.5 mA max. Switching capacity:5 mA min. Residual voltage:3 VDC max. Operating voltage:10 VDC
C-96
6 7 8 9
3 7 5 6104
Multifunction Preset Counter
ut
Total reset/reset 2 in
H7CX
Voltage Inputs (PNP Inputs)
No-contact Input (NPN Transistor)
Sensor
0 V
Input
Reset/reset 1 input
H7CX-A@ H7CX-A11@
Operates when the transistor turns OFF.
6 7 8 9
3 7 5 6104
CP2 input
CP1 input
Total reset/reset 2 input
No-contact Input (PNP Transistor)
H7CX-A@ H7CX-A11@
Operates when the transistor turns ON.
Voltage Input Signal Levels
High level (Input ON): 4.5 to 30 VDC Low level (Input OFF): 0 to 2 VDC Maximum applicable voltage: 30 VDC max. Input resistance: Approx. 4.7 k
Sensor
0 V
Input
Reset/reset 1 input
CP2 input
6 7 8 9
3 7 5 6104
Contact Input
CP1 input
Total reset/reset 2 input
H7CX-A@ H7CX-A11@
Operates when the contact turns ON.
0 V
Input
Reset/reset 1 input
6 7 8 9
3 7 5 6104
CP2 input
CP1 input
Total reset/reset 2 input
Counters
Multifunction Preset Counter
H7CX
C-97
Nomenclature
g
l
l
Indicators Operation Keys
A
Reset Indicator (Orange) Lit when the reset input (1) or reset key is ON.
B
Key Protection Indicator (Orange)
C
Control Output Indicator (Orange) OUT: One stage OUT1, OUT2: Two stages
D
Total Count Indicator Lit when the total count value is displayed.
E
Batch Indicator Lit when the batch count value is displayed.
F
Set Value 1, 2 Stage Indicator
G
Present Value (Main Display) Character height: 11.5 mm (6-digit: 9mm)
H
Set Value (Sub-display) Character height: 6 mm
1
2
3
4 5 6 9
10
Front view of 4-di
1
2
3
4 5 6
9
10
Front view of 6-digit mode
13 14
it mode
I
7
8
11
12
Mode Key Used to switch mode and setting items.
J
Reset Key The operation of the reset function depends on the configuration selected as shown in the table below.
K
Up Keys: 1 to 4 (6-digit models: 1 to 6)
L
Down Keys: 1 to 4
Switches
M
Key Protect Switch
7
8
11
(Factory setting) OFF ON
DIP Switch
N
Reset Operation by Reset Key
Configuration Reset operation
1-stage/2-stage
Resets the present value and outputs.
counter
Total and preset counter
Resets the present value and outputs.
When the total count value is displayed, resets
the present value, the total count value, and outputs.
Batch counter
Resets the present value and OUT2. When the batch count value is displayed,
resets the present value, the batch count value, and outputs.
Dual counter
Resets the CP1 present value, CP2 present val­ue, dual count value, and outputs.
Tachometer
Maintains the measured value and outputs (hold function).
C-98
Multifunction Preset Counter
H7CX
Dimensions
00
6
8
8
)
C
1
)
5
6
8
44.8
44.8
C
1
All units are in millimeters unless otherwise indicated.
Note:
Counter (without Flush Mounting Adapter)
Screw-terminal Models with External Power Supplies
H7CX-A
H7CX-AS
H7CX-A4
H7CX-A4S
H7CX-AW
H7CX-AWS
H7CX-A4W
H7CX-AWD1
X-AWSD
H7
H7CX-AU
H7CX-AUD1
H7CX-AUSD1
484
1
(Flush Mounting)
Note: M3.5 terminal screw (effective length: 6 mm
Screw-terminal Models without External Power Supplies
H7CX-AD
H7CX-ASD
H7CX-A4D
H7CX-A4SD
H7CX-AWSD
H7CX-AWSD
48×48
6
64
44.8×44.8
Counters
44.844.
(Flush Mounting)
11-pin Socket Models
H7CX-A11
H7CX-A11S
H7CX-A11D1
H7CX-A11SD1
H7CX-A114
H7CX-A114S
X-A114D
H7
Note: M3.5 terminal screw (effective length: 6 mm
(Flush Mounting/Surface Mounting)
484
72.
Multifunction Preset Counter
H7CX
C-99
Loading...
+ 30 hidden pages