OMRON H7BR User Manual

Digital Counter H7BR
DIN 72 x 72 mm Counters with Easy-to-use Functions
Designed with an emphasis on ease of operation.
All models equipped with prescale function which displays in units of actual physical parameters (length, volume, etc.).
High-speed response allows 10,000 counts per second.
High-visibility LCD display with built-in backlight.
Online change of set value possible.
Meets UL and CSA standards.
Conforms to EMC standards.
Conforms to EN61010-1/IEC1010-1.
Six-language instruction manual provided.
1
H7BR
Ordering Information
H7BR
H7BR Counters
Standard
(with backlight)
One Stage Two Stages One Stage Two Stages
External power supply
12/24 VDC (switching) [160 mA at 12 VDC; 80 mA at 24 VDC]
Outputs
Contact and NPN transistor output
Contact and PNP transistor output
Control power source
100 to 240 VAC 50/60 Hz
24 VAC 12 to 24 VDC
100 to 240 VAC 50/60 Hz
24 VAC 12 to 24 VDC
No-voltage
Input
H7BR-B
H7BR-B
H7BR-BP
H7BR-BP
H7BR-BV
H7BR-BV
H7BR-BVP
H7BR-BVP
Voltage
input
No-voltage
H7BR-BWP
H7BR-BWP
Note: Specify both the model and control power supply when ordering.
With shock prevention cover types are named “H7BR-jjjj-500.”
Model Legend
Input
H7BR-BW
H7BR-BW
Voltage
input
H7BR-BWV
H7BR-BWV
H7BR
-BWVP
H7BR
-BWVP
No-voltage
Input
H7BR-C
H7BR-C
H7BR-CP
H7BR-CP
±Range type
(with backlight)
Voltage
input
H7BR-CV
H7BR-CV
H7BR-CVP
H7BR-CVP
No-voltage
Input
H7BR-CW
H7BR-CW
H7BR-CWP
H7BR-CWP
Voltage
input
H7BR-CWV
H7BR-CWV
H7BR
-CWVP
H7BR
-CWVP
H7BR-
1234
1. Type
B: Standard C: +/- range
2. Classification
None: 1-stage set counter W: 2-stage set counter
3. Input Type
None: No-voltage input V: Voltage input
4. Output Type
None: NPN output P: PNP output
Accessories (Order Separately)
Soft Cover/Y92A-72F1 Hard Cover/Y92A-72
Note: Models with a Shock Prevention Cover can be ordered by adding “-500” to the end of the model number.
e.g., H7BR-B-500 (100 to 240 VAC, 50/60 Hz)
2
Shock Prevention Cover/Y92A-72T
H7BR
Specifications
Model H7BR-B (Standard type) H7BR-C (±Range type)
Classification Digital preset counter
Mounting method Flush mounting
External connections Screw terminals
Enclosure ratings IP54 (panel surface)
Approved standards UL508, CSA C22.2 No.14, conforms to EN61010-1/IEC61010-1, EN50081-2, and EN50082-2
Input modes* Up (Incrementing), Down (decrementing), and
Output modes* N, F, C, R, K, P, Q, A K, D, L, H
Reset system External, manual and automatic resets (internal
Prescaling function Yes (0.001 to 99.999)
Decimal point adjustment
Teaching function --- Yes
Batch counting function Yes ---
Set compensation --- Yes
Gate input Yes
Sensor power supply 12 VDC/24 VDC (switching)
Input signals Count, reset, key protection, and gate inputs
Input method No-voltage input: Via opening and closing of contact
Control outputs 1 stage model: SPST-NO contact and transistor (NPN or PNP open collector) output
Batch outputs Transistor output (NPN or PNP open collector) ---
Display LCD with backlight
Digits 6 digits (0 to 999,999) ±6 digits (-999,999 to 999,999)
Memory backup Backup time for power interruption: Approx. 10 years at 20°C (lithium battery)
reversible Up/Down A (command inputs), Up/Down B (individual inputs), Up/Down C (quadrature inputs)
according to C, R, P, AND Q mode operation)
Yes (Rightmost 3 digits)
Batch count reset input Compensation input
Voltage input: Via high and low signal voltage (key protection is no-voltage input)
2 stage model: 2 stages of SPST-NO contact and transistor (NPN or PNP open collector) output Transistor output can be changed by switch. (Except for batch count output.)
Reversible Up/Down A (command inputs), Up/Down B (individual inputs), Up/Down C (quadrature inputs)
External and manual resets
H7BR
3
H7BR
gp
300 m/s (Approx. 30G) each in three directions
p
H7BR
Ratings
Rated supply voltage 100 to 240 VAC, 50/60 Hz
Operating voltage range 85% to 110% of rated voltage
Current consumption Approx. 10 VA at 50 Hz, 240 VAC; approx. 6 W at 24 VDC *
Max. counting speeds (CP1, CP2) 30/1k/5k/10 kcps (separate setting for CP1 and CP2)
Compensation and gate input Set to the faster of the CP1 and CP2 max. counting speeds
Reset Min. pulse width for external reset: 1 or 20 ms, also manual reset
Batch count reset Min. pulse width: Approx. 20 ms
Key protection Response time: 1 s
One-shot time 10, 50, 100, 200, 500, and 1,000 ms (separate setting for stages 1 and 2)
Count, compensation, reset, batch count reset, and gate inputs
Key protection input No-voltage input
Control outputs
External power supply 160 mA, 12 VDC ±10% (5% ripple max.)
*When power is turned ON, approx. 8 A inrush current flows for about 2 ms. (24 VDC, 240 VAC)
24 VAC/12 to 24 VDC (contains 20% ripple max.)
No-voltage input ON impedance: 1 kΩ max. (Approx. 2 mA when 0 kΩ) ON residual voltage: 2 V max. OFF impedance: 100 kΩ max. Voltage input (input resistance: approx. 4.7 kΩ) High level: 4.5 to 30 VDC Low level: 0 to 2 VDC
ON impedance: 1 kΩ max. (Approx. 2 mA when 0 kΩ) ON residual voltage: 1 V max. OFF impedance: 100 kΩ min.
Contacts: 3 A at 250 VAC, resistive load (cos φ = 1) Transistor output: Open collector 100mA at 30 VDC max. residual voltage 2 V max. (Approx. 1 V)
80 mA, 24 VDC ±10% (5% ripple max.)
Characteristics
Insulation resistance 100 M min. (at 500 VDC) (between current-carrying terminal and exposed non-current-carrying metal
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminal and exposed non-current-carrying
Impulse withstand voltage 3 kV (between power terminals) for 100 to 240 VAC type, 1 kV for 24 VAC/12 to 24 VDC
Noise immunity ±2 kV (between power terminals) and ±600 V (between input terminals), square-wave noise by noise
Static immunity Malfunction: 8 kV; destruction: 15 kV
Vibration resistance
Shock resistance
Life expectancy
Weight Approx. 270 g
Ambient temperature Operating: –10°C to 55°C (with no icing)
Ambient humidity Operating: 35% to 85%
EMC (EMI): EN50081-2
Case color Light gray (Munsell 5Y7/1)
parts, and between non-continuous contacts)
metal parts)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts for 100 to 240 VAC type, 1.5 kV for 24 VAC/12 to 24 VDC.
simulator (pulse width: 100 ns/1 µs, 1-ns rise)
10 to 55 Hz with 0.75-mm single amplitude each in three directions 10 to 55 Hz with 0.5-mm single amplitude each in three directions
300 m/s2 (Approx. 30G) each in three directions 100 m/s2 (Approx. 10G) each in three directions
10 million operations min. 100,000 operations min. 5 A at 250 VAC in load resistance)
Storage: –25°C to 65°C (with no icing)
Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS): EN50082-2 Immunity ESD: EN61000-4-2:4 kV contact discharge
8 kV air discharge
Immunity RF-interference: ENV50140: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz)
10 V/m (Pulse-modulated, 900 MHz) Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz) Immunity Burst: EN61000-4-4:2 kV power-line
2 kV I/O signal-line
4
H7BR
Block Diagram
H7BR
LCD drive clock generator
Function setting circuit
Key switch circuits
Input circuits (CP1, CP2, com­pensation, gate, reset, batch count reset, key protec­tion)
AC (DC) input
Power circuits *
External power supply
* Power supply is insulated from I/O.
ROM
Count circuits
System clock generator
RAM
Control circuits
Battery
LCD reference voltage generator
LCD driver
One-chip microcom­puter
Power outage detector
LCD
No-contact outputs inverter (DIP switch pins 1,2)
Output circuits (OUT, batch output)
I/O Functions
Inputs CP1/CP2 Count signal inputs.
Reset Resets present value. (to zero in Up modes, to preset with 1-stage models in Down mode, and
Compensation input (±Range type)
Batch count reset (Standard type)
Key protection Makes keys inoperative according to key protection level.
Gate Inhibits counter operation when gate input is ON.
Outputs OUT 1.2 Outputs made according to designated output mode when corresponding preset is reached.
Batch output (Standard type)
Up, Down, and Up/Down (command, individual, or quadrature) inputs accepted.
to preset with 2-stage models.) Count inputs are not accepted while reset input is ON. Reset indicator lit while reset input is ON.
On rising edge of up count signal, present count is reset to compensation value and, therefore, count inputs are accepted even if the compensation input is set to ON (not effective for down count signals.)
Resets batch count to zero and batch output turns OFF. Signals are taken in on the ON edge. Batch count signals are not accepted while batch count reset is ON.
Key protection indicator lit while key protection input is ON. Effective when power supply is turned off. Effective when protect terminals are shorted.
Outputs inhibit on the teaching mode.
Outputs made when batch counter is up to preset number of batches. Batch output remains ON until batch count reset goes ON. When the number of batches is set to zero, batch counting is performed but batch outputs are not made. Batch counter counts the number of completed counts to the preset for 1-stage models and to preset 2 for 2-stage models.
5
H7BR
Engineering Data
Life Expectancy of Contacts
Electrical Life Expectancy (Resistive Load)
H7BR
Electrical Life Expectancy (Inductive Load)
3
No. of operations (x 10 )
250 VAC (cos φ = 1)
Reference: A current of 0.15 A max. can be switched at 125 VDC (cos φ =1) and a current of 0.1 A max. can be switched if L/R = 7 ms. In both cases, a life of 100,000 operations can be expected.
Nomenclature
Front View
Indicator
1. Power indicator
2. Key protection indicator
3. Control output indicator OUT: 1 stage OUT1, OUT2: 2 stages
4. Batch output indicator (H7BR-B only)
5. Present value (character height: 12 mm) (Zeroes suppressed)
6. Set value (character height: 8 mm) (Indicates data in function setting mode)
7. Set value 1,2 stage indicator.
8. Batch indicator (Displays batch count indicator.)
3
30 VDC (cos φ = 1)
No. of operations (x 10 )
250 VAC (cos φ = 0.4)
Load current (A) Load current (A)
30 VDC (L/R = 7 ms)
Operation Key
2
1
5
8
7
10
15
3 4
12 13 1114
9. Increment Keys (1 to 6) (Used to change the corresponding digit of the set value. Used to change data in the function setting mode.)
10. Code Key (H7BR-C type only) (Changes ±code of setting value.)
11. Display Key (Switches to the batch count, teaching mode, setting displays.
6
For 2 stage model, switch set value 1,2.)
12. Batch Key (H7BR-B type only)
9
(Switches to the batch display.)
13. Teaching Key (H7BR-C type only) (Switches to the teaching mode.)
14. Mode Key (Switches from run mode to function setting mode. Changes items in the function setting mode.
15. Reset Key (Resets present value and outputs.)
6
H7BR
Side View
Dip switch
Models
One-stage
Two-stage
Switch No.
OFF
ON
OFF
ON
1234
Operation of each transistor output when count up
---
---
Output 1 OFF to ON Output 1 ON to OFF
Output OFF to ON
Output ON to OFF
Output 2 OFF to ON Output 2 ON to OFF
Invalid
---
---
---
---
H7BR
External power supply
12 VDC
24 VDC
12 VDC
24 VDC
Note: All DIP Switches are set to OFF at the factory.
Operation
Factory Settings
The following table shows the counter settings when it is shipped. Please change the settings as necessary to suit the system before operation. Settings and the display receive power from the internal battery and are therefore unaffected by external power interruptions.
Model
Present value 0 0
Presets 0 0
Batch present count 0 ---
Batch setting count 0 ---
Input mode Up Up/Down C (quadrature)
Output mode N K
Output 2 time (Hold) 1,000 ms
Output 1 time (2-stage only) Hold 1,000 ms
CP1 and CP2 counting speeds 30 cps 30 cps
Min. reset time 20 ms 20 ms
Decimal point Far right (no fractions) Far right (no fractions)
Prescale 1,000 1,000
Compensation count value --- 0
Key protection level KP-1 KP-1
Note: With the initial settings, there will be no output even if the power supply is connected. External inputs and outputs cannot be used
without a power supply.
H7BR-B H7BR-C
7
H7BR
Operational Overview
Run mode
Present value, set value 1
Press the MODE Key
H7BR
Setting mode
Input mode
Press the DISPLAY Key
Press the TEACH key
Teaching mode
Press the MODE or TEACH Key
Press the DISPLAY Key
Present value, set value 2
Batch count value
Present value
Press the MODE or TEACH Key
Present value, set value 1
Press the MODE or TEACH Key
Present value, set value 2
Press the BATCH key
Press the DISPLAY Key
Press the DISPLAY Key
Press the MODE Key
Output mode
Output 2 time
Output 1 time
CP1 and CP2 Count speed
Min. reset time
Decimal point
Prescale value
Compensation count value
Key protection level
Press the MODE Key
Press the MODE Key
Press the MODE Key
Press the MODE Key
Press the MODE Key
Press the MODE Key
Press the MODE Key
Press the MODE Key
Note: Set values are changed with the Increment
Keys (1 to 6).
8
Loading...