Ultra-compact Timer Provides Advanced
Functions and Security Settings.
Basic Features
• Short body with depth of only 59 mm (for 24-VAC / 12 to 24-VDC Models with
Screw Terminals).
• Character height of 12 mm for better readability (on models with 4 digits).
• The present value display characters can be switched between red, green,
and orange.
Safety and Reliability
• Power supply circuit and input circuits are isolated for safety and reliability.
• New set value limit and output counter functions have been added. *4
Other Features
• Front Panel can be changed to white or light gray. *5
• Models with instantaneous contact output added to the series.
*1. For 100 to 240 VAC Models with Screw Terminals 78 mm, Models with Sockets: 63.7 mm
(case dimension).
*2. The H5CX-A11, H5CX-L8 and H5CX-B Timers have only red characters.
*3. Specifications: 100 to 240 VAC
*4. The value of the output counter can only be monitored. It cannot be reset.
*5. Replacement Front Panels sol d separately.
*1
*2
*3
Refer to “Safety Precautions” on page 41.
Features
Basic Features
Ultra Short Body
The body depth has been greatly reduced. Helps in making thinner
control panels. (Models with Screw Terminals)
24-VAC / 12 to 24-VDC Models with Screw Terminals: 59 mm
100 to 240-VAC / VDC Models with Screw Terminals: 78 mm
Models with Sockets: 63.7 mm (case dimension)
* The shortest body for a timer with isolated power supply and input circuits and a maximum
ambient temperature of 55°C (according to OMRON investigation in June 2009).
New models
Easier to Read
For better readability, the character height for the present value display
is 12 mm (on models with 4 digits), the largest class in the industry. The
wide viewing angle and brightness provide excellent visibility.
The number of display segments has also been increased to make settings
easier to understand, and the present value display can be switched between
red, green and orange so that output status can be seen from a distance.
Model with 4 Digits Model with 6 Digits
12 mm
(actual size)
10 mm
(actual size)
New
models
Previous
models
Previous
models
*
Safety and Reliability
Isolated Power Supply and Input Circuits
Power supply circuit and input circuits are isolated for safety and
reliability.
Previous non-isolated timers had wiring restrictions and could be damaged if
wired incorrectly. The New H5CX removes these worries.
Previous
H5CX
AC power
*2
supply
*2. The AC power supply ground is on the commercial power supply side.
*1. New Models (H5CX-@-N) with 100 to 240-VAC specifications.
Input terminal
0-V terminal
Output terminal on PLC
or other device
COM terminal
–V+V
Stabilized DC
power supply
Set Value Limit
You can set an upper limit for the set value to prevent unexpected
operation of output devices caused by setting mistakes.
Worry-free operation
is achieved with the
New H5CX by
restricting the time
that can be set.
*1
Forget These
Worries with the
New H5CX
(Display example)
Note: The H5CX-A11 and H5CX-L8 Timers have only red characters.
Easy to read from the top, bottom, and sides!
The Easiest Operation
Operation is simplified by the
Up/Down Keys for each digit
on 4-digit models and Up Keys
for each digit on 6-digit
models.
Model with 4 DigitsModel with 6 Digits
Output Counter
An output counter counts the number of times that the output turns
ON. (An alarm can be set and the value of the output counter can be
monitored, Unit: 1,000 operations.) This counter is useful in managing
the service life of the Timer or the load.
1
H5CX-@-N
Other Features
Change the Front Panel Color
The Front Panel can be replaced with an optional Front Panel (order
separately) with a different color to match the installation site. Select
from black, white, and light gray.
Black
(standard)
Models with Instantaneous Contact Output
Models with instantaneous contact outputs have been added to the
lineup for use with self-holding circuits and as auxiliary relays. These
models are also convenient when replacing analog timers.
WhiteLight gray
You can replace
the Front Panel.
Model Number Structure
Model Configuration
Universal NPN/PNP Input
DC 2-wire sensors can be connected for a wide range of input
devices.
Waterproof, Dust-proof Structure (UL508 Type
4X and IP66)
Worry-free application is possible in locations subject to water.
Note: When the Y92S-29 Waterproof Packing is used.
Key Protection
Select from any of seven protection patterns. Use the best one for the
application.
New Modes
Modes, such as a stopwatch mode (Mode S), have been added.
Select any of 15 modes.
Note: 1. You can change the color of the front panel when mounting the Timer. The Timer is shipped with a black (N1.5) Front Panel.
2. "TIMER" is printed on the front of Replacement Front Panels.
Soft Cover
ModelsRemarksPage
Y92A-48F1---12
Hard Cover
ModelsRemarksPage
Y92A-48---12
Flush Mounting Adapter
ModelsRemarksPage
Y92F-30Included with models with terminal blocks.
Y92F-45
Use this Adapter to install the Timer in a cutout
previously made for a DIN 72 x 72 mm device
(panel cutout: 68 x 68 mm).
12
Waterproof Packing
ModelsRemarksPage
Y92S-29Included with models with terminal blocks.12
Connection Sockets
ModelsTypeConnectable TimersRemarksPage
P2CF-08
P2CF-08-E
P2CF-11
P2CF-11-E
P3G-08
P3GA-11H5CX-A11@
Front Connecting
Socket
Front Connecting
Socket
(Finger-safe Type)
Front Connecting
Socket
Front Connecting
Socket
(Finger-safe Type)
Back Connecting Socket
H5CX-L8@
H5CX-A11@
H5CX-L8@
Round crimp terminals cannot be used on Finger-safe
Sockets. Use forked crimp terminals.
Round crimp terminals cannot be used on Finger-safe
Sockets. Use forked crimp terminals.
A Y92A-48G Terminal Cover can be used with the
Socket to create a finger-safe construction.
Terminal Covers for P3G-08 and P3GA-11 Back-connecting Sockets
ModelsRemarksPage
Y92A-48G---14
13
4
H5CX-A@-N/-L@-N
H5CX-A@-N/-L@-N Digital Timers
• Switch the display color* between red, green, and orange
to see the output status from a distance.
• Up/Down Keys for each digit enable easy operation.
• Cyclic control is easy with the Twin Timer and Variable
ON/OFF Duty modes.
* Not supported by the H5CX-A11@ or H5CX-L8@.
Specifications
Ratings
ItemModelsH5CX-A@-NH5CX-A11@-NH5CX-L8@-N
ClassificationStandard TypeEconomy Type
Ratings
Mounting methodFlush mountingFlush mounting, surface mounting, DIN track mounting
External connectionsScrew terminals11-pin socket8-pin socket
Degree of protection
Digits
Time ranges
Timer modeElapsed time (Up), remaining time (Down) (selectable)
Inputs
Reset systemPower reset (depending on output mode), external reset, manual reset, automatic reset (depending on output mode)
Power resetMinimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1, and toff-1 mode)
Reset voltage10% max. of rated supply voltage
Sensor waiting time250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Power supply
*1
voltage
Operating voltage
fluctuation range
Power consumption Approx. 6.2 VA at 100 to 240 VAC, Approx. 5.1 VA/2.4 W at 24 VAC/12 to 24 VDC
Input signalsSignal, Reset, Gate
Input method
Signal, reset, gate Minimum input signal width: 1 or 20 ms (selectable, same for all input)
• 100 to 240 VAC 50/60 Hz
• 12 to 24 VDC/24 VAC 50/60 Hz
85% to 110% of rated supply voltage (90% to 110% at 12 to 24 VDC)
IEC IP66, UL508 Type 4X (indoors) for panel surface only and when Y92S-29 Waterproof Packing is used
4 digits
0.001 s to 9.999 s, 0.01 s to 99.99 s, 0.1 s to 999.9 s, 1 s to 9999 s, 1 s ti 99 min 59 s
0.1 m to 999.9 min, 1 min to 9999 min, 1 min to 99 h 59 min, 0.1 h to 999.9 h, 1 h to 9999 h
No-voltage InputON impedance: 1 kΩ max. (Leakage current: 12 mA when 0 Ω)
Voltage InputHigh (logic) level: 4.5 to 30 VDC
No-voltage input/voltage input (switchable)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Signal, Reset
(no inputs on models with instantaneous
contact outputs)
No-voltage Input
ON impedance: 1 kΩ max.
(Leakage current: 12 mA when 0 Ω)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
A: Signal ON Delay I, A-1: Signal ON Delay II, A-2: Power ON Delay I, A-3: Power ON
Output modes
Output
Display method
Memory backupEEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature range -10 to 55°C (-10 to 50°C if counters are mounted side by side) (with no icing or condensation)
Storage temperature range-25 to 70°C (with no icing or condensation)
Operating humidity range25% to 85%
Case colorBlack (N1.5) (Optional Front Panels are available to change the Front Panel color to light gray or white.)
Attachments
*1. Do not use the output from an inverter as the power supply. The ripple must be 20% maximum for DC power.
*2. Inrush current will flow for a short time when the power supply is turned ON.
*3. The display is lit only when the power is ON. Nothing is displayed when power is OFF.
One-shot output
time
Control output
*3
Inrush Current (Reference Values)
VoltageApplied voltageInrush current (peak value)Time
100 to 240 VAC264 VAC5.3 A0.4 ms
12 to 24 VDC/24 VAC
Delay II, b: Repeat Cycle 1, b-1: Repeat Cycle 2, d: Signal OFF Delay, E: Interval, F:
Cumulative, Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, toff: Flicker OFF Start 1,
ton: Flicker ON Start 1, toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2
0.01 to 99.99 s
• Models with Contact Outputs
5 A at 250 VAC/30 VDC, resistive load (cos =1)
Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
• Transistor output: NPN open collector,
100 mA at 30 VDC max., residual voltage: 1.5 VDC max. (Approx. 1 V), Leakage current: 0.1 mA max.
Waterproof packing, flush mounting
adapter, label for DIP switch settings
26.4 VAC6.4 A1.4 ms
26.4 VDC4.4 A1.7 ms
(switchable between red,
green, and orange)
green
7-segment, negative transmissive LCD;
Present value: 12-mm-high characters, red
Set value:6-mm-high characters, green
Label for DIP switch settings
Models with Instantaneous Contact
Outputs
A-2: Power ON Delay I, b: Repeat Cycle 1,
E: Interval, Z: ON/OFF-duty-adjustable
flicker, toff: Flicker OFF Start 1, ton:
Flicker ON Start 1
---
5
H5CX-A@-N/-L@-N
Characteristics
Power-ON start: ±0.01% ±50 ms max. (See note 1.)
Accuracy of operating time
and setting error (including
temperature and voltage
influences)
Signal start: ±0.005
Signal start for transistor output model: ±0.005%±3 ms max. (See note
1 and 2.)
If the set value is within the sensor waiting time at startup the control
output of the H5CX will not turn ON until the sensor waiting time passes.
Note: 1. The values are based on the set value.
2. The value is applied for a minimum pulse width of 1 ms.
100 MΩ min. (at 500 VDC) between current-carrying terminal and
Insulation resistance
exposed non-current-carrying metal parts, and between non-continuous
contacts
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and
non-current-carrying metal parts
2,000 VAC, 50/60 Hz for 1 min between power supply and input circuits
Dielectric strength
for the models other than H5CX-@D-N
1,000 VAC, 50/60 Hz for 1 min between control output, power supply,
and input circuits for H5CX-@SD-N
2,000 VAC, 50/60 Hz for 1 min between control output, power supply,
and input circuits for other models
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12
Impulse withstand voltage
Noise immunity
Static immunity
Vibration
resistance
Shock
resistance
Life
expectancy
Destruction
Malfunction
Destruction 300 m/s2 in three directions, three cycles
Malfunction 100 m/s2 in three directions, three cycles
Mechanical
Electrical
to 24 VDC
4.5 kV (between current-carrying terminal and exposed non-currentcarrying metal parts) for 100 to 240 VAC 1.5 kV for 24 VAC/12 to 24 VDC
±1.5 kV (between power terminals) and ±600 V (between input
terminals), square-wave noise by noise simulator (pulse width: 100 ns/
1 µs, 1-ns rise)
Malfunction: 8 kV
Destruction: 15 kV
10 to 55 Hz with 0.75-mm single amplitude each in three directions for
2 h each
10 to 55 Hz with 0.35-mm single amplitude each in three directions for
10 min each
10,000,000 operations min. (under no load at 1,800 operations/h and
ambient temperature of 23
100,000 operations min. (5 A at 250 VAC, resistive load at 1,800
operations/h and ambient temperature of 23
Weight Approx. 115 g (Timer only)
* Refer to Life-test Curve.
%±30 ms max. (See note 1.)
°C)
°C)
Life-test Curve (Reference
Values)
)
4
1,000
500
100
Switching operations (× 10
50
10
0 1 2 3 4 5
A maximum current of 0.15 A can be switched at
125 VDC (cosφ =1) and a maximum current of 0.1
A can be switched if L/R is 7 ms. In both cases, a
life of 100,000 operations can be expected.
*
DC30V L/R=7ms
AC250V cos
φ
=0.4
AC250V/DC30V
φ
=1
cos
Load current (A)
6
H5CX-A@-N/-L@-N
Applicable Standards
UL508/Listing, UL508 Type 4X for indoor use (enclosure rating), CSA C22.2 No. 14
conforms to EN61812-1 (Pollution degree 2/overvoltage category III)
Approved safety standards
EMC
*1. The following safety standards apply to models with sockets (H5CX-A11@ or H5CX-L8@).
cUL (Listing): Applicable when an OMRON P2CF (-E) Socket is used.
cUR (Recognition): Applicable when any other socket is used.
*2. Excluding the H5CX-ASD-N/-A11SD-N/-L8SD-N.
B300 PILOT DUTY
1/4 HP 120 VAC, 1/3 HP, 240 VAC, 5 A resistive load
VDE0106/P100
CCC: Pollution degree 2, Overvoltage category II
(EMI)EN61812-1
Emission Enclosure:EN55011 Group 1 class A
Emission AC mains:EN55011 Group 1 class A
(EMS)EN61812-1
Immunity ESD:EN61000-4-2: 6 kV contact discharge (level 2)
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:EN61000-4-4: 2 kV power-line (level 3);
Immunity Surge:EN61000-4-5: 1 kV line to lines (power and output lines) (level 3);
Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage)
*2
8 kV air discharge (level 3)
10 V/m (Pulse-modulated, 900 MHz 5 MHz) (level 3)
1 kV I/O signal-line (level 4)
2 kV line to ground (power and output lines) (level 3)
I/O Functions
For details, refer to the timing charts on page 20 and page 29.
Start signal
*1
Inputs
OutputsControl output (OUT) Outputs take place according to designated operating mode when timer reaches corresponding set value.
*1. The H5CX-L8E@ does not have an input.
*2. The H5CX-L@ does not have a gate input.
Reset
Gate
*2
Normally functions to start timing.
In modes A-2 and A-3, disable timing. In mode S, starts and stops timing.
• Resets present value. (In elapsed time mode, the present value returns to 0; in remaining time mode,
the present value returns to the set value.)
• Count inputs are not accepted and control output turns OFF while reset input is ON.
• Reset indicator is lit while reset input is ON.
Disables timing. (If a reset occurs while the gate input is ON, a reset will be performed.)
*1
,
Response Delay Time When Resetting (Transistor Output)
The following table shows the delay from when the reset signal is input until the output is turned OFF.
Minimum reset signal widthOutput delay time
1 ms0.8 to 1.2 ms
20 ms15 to 25 ms
(Reference value)
7
H5CX-A@-N/-L@-N
Connections
Block Diagram
Output circuit
(Basic insulation)
Input circuits
(Basic insulation)
Internal control
circuit
Power supply
circuit
(See note.)
Display circuit
Key switch circuit
Note: Basic insulation is provided between the power supply circuit and the input circuits. However, basic insulation is not provided in the
H5CX-@D-N.
Terminal Arrangement
Confirm that the power supply meets specifications before use.
H5CX-A-N/-AD-NH5CX-AS-N/-ASD-N
Gate
Reset
0V
6789
12345
(-)(+)
Signal
Contact output
Terminals 1 and 6 of the H5CX-AD-N
are connected internally.
H5CX-A11-N/-A11D-NH5CX-A11S-N/-A11SD-N
Reset
Signal
Gate
Unused
0V
5
4
3
2
Unused
(-)(+)
6
1
11
7
10
8
9
Internal circuit
Contact
output
Terminals 2 and 3 of the
H5CX-A11D-N are
connected internally.
H5CX-L8-N/-L8D-NH5CX-L8S-N/-L8SD-N
5
6
7
Internal circuit
Contact
output
Terminals 1 and 2 of the H5CX-L8D-N
are connected internally.
Signal
Reset
3
2
0V
4
1 8
(-) (+)
H5CX-L8E-N/-L8ED-N
Internal circuitInternal circuit
4
5
3
Instantaneous
contact output
OUT1
2
6
7
1 8
(–) (+)
Time-limit
contact output
OUT2
Note: Do not connect unused terminals as relay terminals.
0V
6789
12345
(-)(+)
Reset
Signal
Gate
Unused
0V
Signal
Reset
Transistor Output
• The transistor output of
the H5CX is insulated
from the internal circuitry
by a photocoupler, so the
transistor output can be
used as both NPN and
PNP output.
• The diode connected to
the collector of the output
transistor is used to
absorb inverted voltage
that is generated when an
inductive load is
connected to the H5CX.
Gate
Reset
Signal
Transistor output
6
5
4
3
2
1
11
Unused
(-)(+)
4
3
2
1 8
0V
(-) (+)
7
10
5
8
9
Unused
6
7
Terminals 1 and 6 of the H5CX-ASD-N
are connected internally.
Internal circuit
Transistor
output
Terminals 2 and 3 of the
H5CX-A11SD-N are
connected internally.
Internal circuit
Transistor
output
Terminals 1 and 2 of the H5CX-L8SD-N
are connected internally.
The inputs are no-voltage (closed or open) inputs or voltage inputs except for the H5CX-L8@. (The inputs of the H5CX-L8@ are no-voltage inputs
only. The H5CX-L8E@ does not have an input.)
No-voltage Inputs (NPN Inputs)
Open CollectorVoltage OutputContact InputDC Two-wire Sensor
Approx. 4.7 kΩ
IN
Internal
circuit
PLC or
sensor
Gate input
Reset input
Signal input
0 V for inputs
H5CX-A@
H5CX-A11@
H5CX-L8@
Note: Operate with transistor ON
6789
3765
134
-
No-voltage Input Signal Levels
Short-circuit level Transistor ON
• Residual voltage: 3 V max.
No-contact
input
• Impedance when ON: 1 kΩ max.
(The leakage current is approx. 12 mA when the
impedance is 0 Ω.)
Open level Transistor OFF
• Impedance when OFF: 100 kΩ min.
Sensor
Reset input
0 V for inputs
H5CX-A@
H5CX-A11@
H5CX-L8@-
Note: Operate with transistor ON
6789
3765
134
Gate input
Signal input
0 V for inputs
H5CX-A@
H5CX-A11@
H5CX-L8@
Note: Operate with relay ON
6789
3765
134
Gate input
Reset input
Signal input
-
Applicable Two-wire Sensor
• Leakage current: 1.5 mA max.
• Switching capacity: 5 mA min.
• Residual voltage: 3.0 VDC max.
• Operating voltage: 10 VDC
Contact input Use contacts which can adequately switch 5 mA at 10 V
Note: The DC voltage must be 30 VDC max.
Voltage Inputs (PNP Inputs)
The inputs of the H5CX-L8@ are no-voltage inputs only.
H5CX-A-N/-AS-N (Provided with Adapter and Waterproof Packing)
Y92S-29 (provided)
Waterproof
Packing
58
48
(51)
Y92F-30 (provided)
Pane l
Flush Mounting Adapter
76.57.5
H5CX-AD-N/-ASD-N (Provided with Adapter and Waterproof Packing)
Y92S-29 (provided)
Waterproof
Packing
58
48
(51)
Y92F-30 (provided)
Pane l
Flush Mounting Adapter
57.57.5
Panel Cutouts
Panel cutouts areas shown below. (according
to DIN43700).
60 min.
+0.6
45
0
+0.6
45
0
15 min.
60 min.
Note: 1. The mounting panel thickness
should be 1 to 5 mm.
2. To allow easier operation, it is
recommended that Adapters
be mounted so that the gap
between sides with hooks is at
least 15 mm (i.e., with the
panel cutouts separated by at
least 60 mm).
3.
It is possible to horizontally
mount Timers side by side.
Attach the Flush Mounting
Adapters so that the surfaces
without hooks are on the sides of
the Timers. (However, if Timers
are mounted side by side, water
resistance will be lost.)
n Units mounted side-by-side
H5CX-A11@-N (Adapter and Waterproof Packing Ordered Separately)
Y92S-29 (order separately)
Waterproof Packing
58
48
(51)
Pane l
Y92F-30 (order separately)
Flush Mounting Adapter
89.97.5
H5CX-L8@-N (Adapter and Waterproof Packing Ordered Separately)
Y92F-30 (order separately)
Pane lY92S-29 (order separately)
Waterproof Packing
58
48
(51)
Flush Mounting Adapter
84.87.5
P3GA-11 (order
separately)
Back-connecting
Socket
P3G-08 (order
separately)
Back-connecting
Socket
A
A=(48n-2.5)
With Y92A-48F1 attached.
A={48n-2.5+(n-1)×4}
With Y92A-48 attached.
A = (51n - 5.5)
+1
–0
+1
–0
+1
–0
Dimensions with Front
Connecting Socket
*
103.2
*
92.3
P2CF-08(-E) (order separately)
Front Connecting Socket
* These dimensions vary with the type of DIN track
(reference value).
H5CX
-A11@-N
P2CF-11(-E) (order separately)
Front Connecting Socket
H5CX
-L8@-N
100.9
90
11
H5CX-A@-N/-L@-N
Accessories (Order Separately)
Note:
Depending on the operating environment, the condition of
resin products may deteriorate, and may shrink or become
harder. Therefore, it is recommended that resin products are
replaced regularly.
Front Panel (Replacement Part)
You can change the color of the front panel when mounting the Timer.
The Timer is shipped with a black (N1.5) Front Panel.
Y92P-CXT4S
Cover for Timer with 4 Digits
White (5Y9.2/0.5)
Y92P-CXT4G
Cover for Timer with 4 Digits
Light gray (5Y7/1)
Y92P-CXT4B
Cover for Timer with 4 Digits
Black (N1.5)
Replacement Method
The Front Panel is attached to
the Terminal with tabs in four
locations. To remove the Front
Panel, open the tabs and pull the
Front Panel forward.
Ta bs
Grooves
To attach the Front Panel, press
it onto the Timer so that all four
tabs lodge into the groves on the
body of the Timer.
Soft Cover
Y92A-48F1
Hard Cover
Y92A-48
Protecting the Timer in Environments Subject to Oil
The H5CX's panel surface is water-resistive (IP@6, UL Type 4X)
and so even if drops of water penetrate the gaps between the keys,
there will be no adverse effect on internal circuits. If, however, there
is a possibility of oil being present on the operator's hands, use the
Soft Cover. The Soft Cover ensures protection equivalent to IP54
against oil. Do not, however, use the H5CX in locations where it
would come in direct contact with oil.
Flush Mounting Adapter
Y92F-30
Order the Flush
Mounting Adapter
separately if it is
lost or damaged.
Note: A Flush
Mounting
Adapter is
included with
models with
screw
terminals.
Y92F-45
Use this Adapter
to install the
Timer in a cutout
previously made
for a DIN 72 x 72
mm device
(panel cutout:
68 x 68 mm).
Waterproof Packing
Y92S-29
Note: The
Waterproof
Packing is
included with
models with
screw
terminals.
The Waterproof Packing will deteriorate, harden, and shrink
depending on the application environment. To ensure maintaining the
IP@6, UL Type 4X waterproof level, periodically replace the
Waterproof Packing. The periodic replacement period will depend on
the application environment. You must confirm the proper
replacement period. Use 1 year or less as a guideline. If the
Waterproof Packing is not replaced periodically, the waterproof level
will not be maintained.
It is not necessary to mount the Waterproof Packing if waterproof
construction is not required.
Order the Waterproof Packing
separately if it is lost or damaged.
The Waterproof Packing can be used
to achieve IP66 protection.
12
Connection Sockets
Front-connecting Sockets
ModelDimensions
P2CF-08
Two, 4.5-dia. holes
50 max.
20.3 max.
H5CX-A@-N/-L@-N
Terminal arrangement
and internal connections
Mounting hole
dimensions
P2CF-08-E
(Finger Safe Terminal)
P2CF-11
P2CF-11-E
(Finger Safe Terminal
Type)
Eight, M3.5 x 7.5 sems screws
Two, 4.5-dia. holes
Eight, M3.5 x 7.5 set screws
Two, 4.5-dia. holes
Eleven, M3.5 x 7.5 sems screws
Two, 4.5-dia. holes
9
10 11
Eleven, M3.5 x 7.5 set screws
4
7.8
50 max.
±0.2
40
4365
P2CF-08-E
70 max.
10A250VAC
RESISTIVE
1278
4
7.8
50 max.
70 max.
4
7.8
50 max.
±0.2
40
7865
P2CF-11-E
10A250VAC
RESISTIVE
4
3
12
70 max.
4
7.8
70 max.
3
21.5 max.
20.3
3
1.3
5
31.2 max.
3
31.2 max.
30
3
1.2
5
35.4
4.5
19
35.4
4.5
35.4
4.5
35.4
4.5
Note: Round crimp terminals cannot be used on Finger-safe Sockets. Use forked crimp terminals.
6 54 3
7 81 2
(Top View)
8 76 5
93
10 111 2
(Top View)
Two, M4 or 4.5-dia. holes
±0.2
40
Note: The Socket can
also be mounted
to DIN track.
4
Two, M4 or 4.5-dia. holes
±0.2
40
Note: The Socket can
also be mounted
to DIN track.
Back-connecting Sockets
ModelDimensions
P3G-08
45
P3GA-11
45
27 dia
45
27 dia
45
4.917
4.5
16.3
25.6
6.2
Note: A Y92A-48G Terminal Cover can be used with the Socket to create a finger-safe construction.
Terminal arrangement
and internal connections
6543
7812
(Bottom View)
876
5
4
3
9
101112
(Bottom View)
13
H5CX-A@-N/-L@-N
Terminal Covers for P3G-08 and P3GA-11 Back-connecting Sockets
ModelDimensions
Y92A-48G
Twelve, 6.4 dia
34
Y92A-48G
47.4
47.7×47.748×48
UP
P C
16.5
24.6
27.6
Note: The Terminal Cover can be used with a Back-mounting Socket (P3G-08 or P3GA-11) to create a finger-safe construction.
Optional Products for Track Mounting
Mounting Track
PFP-100N
PFP-50N
Mounting Track
PFP-100N2
4.5
4.5
15 252510
10
15 2525
1,000 (500) *
1,000
2525 1510
102525
15 (5) *
* The values shown in parentheses are for the PFP-50N.
±0.15
7.3
±0.3
35
±0.3
242735
1
±0.15
27
1
16
29.2
1.5
End Plate
PFP-M
Spacer
PFP-S
Note: Order Spacers in increments of 10.
M4 x 8 pan
head screw
50
11.5
10
M4 spring washer
5
44.3
10
16
12
16.5
6.2
1.8
1
35.5 35.3
1.8
1.3
4.8
34.8
14
Operating Procedures
Setting Procedure Guide
Settings for Timer Operation
Use the following settings.
Settings for Twin Timer Operation
Refer to page 25.
* It is not necessary to mount the Waterproof Packing if waterproof construction is not required.
Operating Procedures for Timer Function
*
*
H5CX-A@-N/-L@-N
Timer
Step1
Settings for basic functions can be performed with just the DIP switch.
Note: There is no DIP switch on the H5CX-L8@. Go to .
Key-protect Switch
ON
OFF
ItemOFFONTime rangePin 4Pin 3Pin 2
1
DIP switch settings
2
Time range
3
4
5
Output modes
6
Timer mode
7
Input signal width
8
Note: All the pins are factory-set to OFF.
DisabledEnabledON
Refer to the table on
the right.
Refer to the table on
the right.
UPDOWN
20 ms1 ms
Be sure to turn ON pin 1 of the DIP switch.
Changes to DIP switch settings are enabled when the
power is turned ON.
(Set the DIP switch while the power is OFF.)
Step2
Be sure to set pin 1 to ON when using the DIP switch.
12345678
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
Pin 6 Output modePin 5
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
Mode A: Signal ON delay 1
(Timer resets when power comes ON.)
Mode A-2: Power ON delay 1
(Timer resets when power comes ON.)
Mode E: Interval
(Timer resets when power comes ON.)
Mode F: Cumulative
(Timer does not reset when power
comes ON.)
0.001 s to 9.999 s
0.01 s to 99.99 s
0.1 s to 999.9 s
1 s to 9999 s
0 min 01 s to 99 min 59 s
0.1 min to 999.9 min
0 h 01 min to 99 h 59 min
0.1 h to 999.9 h
After making DIP switch settings for basic operation, advanced functions can be added using the operation keys on the front panel. Refer to
Step2
on page 16 for details.
15
H5CX-A@-N/-L@-N
Timer
Step2
Settings that cannot be performed with the DIP switch are performed with the operation keys.
• Change to Function Setting Mode.
Power ON
*
1
3 s min.
Run mode
Function setting mode
*
2
3 s min.
*1. If the mode is switched to the function setting mode during operation, operation will continue.
*2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode.
Also, when settings are changed, the timer is reset (time initialized and output turned OFF).
The characters displayed in reverse video are the default settings.
When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).
If pin 1 of the DIP switch is set to ON, the setting items indicated in will not be displayed.
Time range
Set the time range using the keys.
For details, refer to the Time Range List.
Timer mode
Set the timer mode using the keys.
Set the output mode using the keys.
Output modes
Note:
contact outputs.
Set each digit for the output time using the corresponding keys.
Output time
(If the output time is set to 0.00, is displayed.)
Note:
Set the input signal width using the keys.
Note:
Function setting mode
Input signal
For details on operations in run mode, refer to page 19.
s
(DOWN)(UP)
(A-1)(A-2)(A-3)(b-1)(b)(d) (E) (F)(S)(Z)(A)
Only modes A-2, b, E, and Z can be selected for models with instantaneous
(0.01s) (99.99s)(Output hold)
sshs
downup
a-3bb-1defs
99.990.01hold
~
……
za-1aa-2
hold
Displayed for modes A, A-1, A-2, A-3, b, b-1 and S only.
20ms1ms
Not displayed for models with instantaneous contact outputs.
Displayed only for models with terminal screws (H5CX-A@).
Set the function (instantaneous or time-limit operation) for the instantaneous output (output 1)
using the Keys.
(Instantaneous) (Time-limit)
Note:
Displayed only for models with instantaneous contact outputs.
2c1c1c
H5CX-A@-N/-L@-N
Timer
page
To previous
page
From previous
Function setting mode
Set value
upper limit
Key protect
level
*1
Output ON
count alarm
set value/
monitor value
Set the digits for the set value limit using the corresponding keys.
9999
1
(9999)(1)
Set the key protect level using the keys.
kp-1
(KP-1)(KP-2)(KP-3)(KP-4)(KP-5)(KP-6)(KP-7)
kp-2
kp-3kp-4kp-5kp-6kp-7
*1. Set each digit for the output time using the corresponding keys.
• Models without Instantaneous Contact Outputs
Output ON
count alarm
set value
(0 x 1000 times)
~
99990
(9999 x 1000 times)
Output ON
count monitor
value
Note: The monitor value is only displayed.
It cannot be set.
• Models with Instantaneous Contact Outputs
Instantaneous
output 1
(OUT1) ON
count alarm
set value
Instantaneous
output 2
(OUT2) ON
count alarm
set value
Instantaneous
output 1
(OUT1) ON
count monitor
value
Instantaneous
output 2
(OUT2) ON
count monitor
value
(0 x 1000 times)
(0 x 1000 times)
Note: The monitor value is only displayed.
It cannot be set.
Note: The monitor value is only displayed.
It cannot be set.
~
(9999 x 1000 times)
~
(9999 x 1000 times)
99990
99990
17
H5CX-A@-N/-L@-N
Timer
Explanation of Functions
Operating Procedures for Timer Function
Items marked with stars () can be set using the DIP switch.
Time Range (timr)
Set the range to be timed in the range 0.001 s to 9,999 h.
Settings of type ---- h (9,999 h) and ---- min (9,999 min) cannot be
made with the DIP switch. Use the operation keys if these settings are
required.
Timer Mode (timm)
Set either the elapsed time (UP) or remaining time (DOWN) mode.
In UP mode, the elapsed time is displayed, and in DOWN mode, the
remaining time is displayed.
Output Mode (outm)
Set the output mode.
The possible settings are A, A-1, A-2, A-3, b, b-1, d, E, F, Z and S.
Only output modes A, A-2, E, and F can be set using the DIP switch.
Use the operation keys if a different setting is required.
(For details on output mode operation, refer to "Timing Charts" on
page 20.)
Output Time (otim)
When using one-shot output, set the output time for one-shot output
(0.01 to 99.99 s).
One-shot output can be used only if the selected output mode is A,
A-1, A-2, A-3, b, b-1 or S.
If the output time is set to 0.00,
held.
Input Signal Width (iflt)
Set the minimum signal input width (20 ms or 1 ms) for signal, reset,
and gate inputs.
The same setting is used for all external inputs (signal, reset, and gate
inputs).
If contacts are used for the input signal, set the input signal width to
20 ms.
Processing to eliminate chattering is performed for this setting.
NPN/PNP Input Mode (imod)
Select either NPN input (no-voltage input) or PNP input (voltage
input) as the input format.
Set an NPN input when using a 2-wire sensor.
For details on input connections, refer to "Input Connections" on
page 9.
hold is displayed, and the output is
Display Color (colr)
(Terminal block model: H5CX-A@ only)
Set the color used for the present value.
Output OFFOutput ON
red
grn
org
r-g
g-r
r-o
o-r
g-o
o-g
Red Green
GreenRed
RedOrange
Orange Red
GreenOrange
OrangeGreen
Red (fixed)
Green (fixed)
Orange (fixed)
Key Protect Level (kypt)
Set the key protect level.
Refer to “Key Protect Level” on page 32.
Instantaneous/Time-limit (otmd)
Set the contact output to time-limit SPDT + instantaneous SPDT or
time-limit SPDT operation.
Set Value Upper Limit (sl-h)
Set the upper limit for the set value when it is set in Run Mode.
The limit can be set to between 1 and 9999.
This setting does not apply to the ON duty in Z mode.
Output ON Count Alarm Set Value (on-a)
Set the alarm value for the output ON count.
The limit can be set to between 0
(9,999,000 times). Only the underlined values are set. The alarm will
be disabled if 0 is set.
If the total ON count of the output exceeds the alarm set value,
be displayed on the Timer to indicate that the output ON count alarm
value was exceeded. Refer to “Self-diagnostic Function” on page 32 for information on the
x 1000 (0 times) and 9999 x 1000
e3 will
e3 display.
ON Count Alarm Set Values for Outputs 1 and 2 (OUT1
and OUT2) (on1a and on2a)
Set the ON count alarm values for the outputs 1 and 2.
The limit can be set to between 0
(9,999,000 times). Only the underlined values are set. The alarm will
be disabled if 0 is set.
If the total ON count of instantaneous output 1 or 2 exceeds the alarm
set value,
ON count alarm value was exceeded. Refer to “Self-diagnostic Function” on page 32 for information on the
e3 will be displayed on the Timer to indicate that the output
x 1000 (0 times) and 9999 x 1000
e3 display.
18
Output ON Count Monitor Value (on-c)
The monitor value is only displayed. It cannot be set.
The output ON count will be 1,000 times the displayed value.
ON Count Monitor Values for Outputs 1 and 2 (OUT1 and
OUT2) (on1c and on2c)
The monitor value for output 1 or 2 is only displayed. It cannot be set.
The output ON count will be 1,000 times the displayed value.
Operation in Run Mode
↔
Operating Procedures for Timer Function
H5CX-A@-N/-L@-N
Timer
Present value
Set value
When Output Mode Z Is Selected
Present value
ON duty ratio
Present value
Cycle time
Set each digit for the output time using the corresponding keys.
Note: H5CX-L8E@-N Precautions
Set the Timer’s set value before using the Timer in a self-holding circuit.
Set each digit for the output time using the corresponding keys.
(The keys for the 4th digit cannot be used.)
Set each digit for the output time using the corresponding keys.
Present Value and Set Value
These items are displayed when the power is turned ON. The present
value is displayed in the main display and the set value is displayed
in the sub-display.
The values displayed will be determined by the settings made for the
time range and the timer mode in function setting mode.
Present Value and ON Duty Ratio (Output Mode = Z)
The present value is displayed in the main display and the ON duty
ratio is displayed in the sub-display. Set the ON duty ratio used in ON/
OFF-duty-adjustable flicker mode (Z) as a percentage.
ON time = Cycle time x
ON duty ratio (%)
100
The output accuracy will vary with the time range, even if the ON duty
ratio setting is the same. Therefore, if fine output time adjustment is
required, it is recommended that the time range for the cycle time is
set as small as possible.
Examples: 1. When Time Range = - - - - s (9999 s)
20(s) x
31(%)
100
= 6.2(s)
Rounded off to the nearest integer (because of the
time range setting) → ON time = 6 s
2. When Time Range = - -. - - s (99.99 s)
20.00(s) x
31(%)
100
= 6.200(s)
Rounded off to 2 decimal places (because of the time
range setting) → ON time = 6.20 s
If a cycle time is set, cyclic control can be performed in ON/OFF-dutyadjustable flicker mode simply by changing the ON duty ratio.
Present Value and Cycle Time (Output Mode = Z)
The present value is displayed in the main display and the cycle time
is displayed in the sub-display. Set the cycle time.
ON duty (%)
Control output
Cycle time
Elapsed cycle time
ON duty set as a percentage
Up/Down keys used for analog
adjustment of the ON duty
OpenClose
Opening/
closing valve
ON duty
Fully closed
Fully open
0%↔100%
19
H5CX-A@-N/-L@-N
Timer
Timing Charts
Operating Procedures for Timer Function
Models without Instantaneous Contact Outputs
The gate input is not included in the H5CX-L8@ models.Either one-shot output or sustained output can be selected.
Mode A: Signal ON delay 1 (Timer resets when power comes ON.)
Basic operationDetailed operation
Power
Power
Start signal
*
Start signal
input
Output
Timing
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
The control output is controlled using a sustained or
one-shot time period.
Note: Output is instantaneous when setting is 0.
Mode A-1: Signal ON delay 2 (Timer resets when power comes ON.)
Basic operation Detailed operation
Powe r
Start signal
input
Output
Timing starts when the start signal goes ON, and
resets when the start signal goes OFF.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
The control output is controlled using a sustained or
one-shot time period.
Timing
Note: Output is instantaneous when setting is 0.
Mode A-2: Power ON delay 1 (Timer resets when power comes ON.)
Basic operationDetailed operation
Gate
Reset
Control output
Set value
UP
Set value
Timing diagram
DOWN
Power
Start signal
Gate
Reset
Control output
Set value
UP
Set value
Timing diagram
DOWN
Power
tt
0
0
t
0
0
Powe r
Output
Timing starts when the reset input goes OFF.
The start signal disables the timing function (i.e.,
same function as the gate input).
The control output is controlled using a sustained or
one-shot time period.
Timing
Note: Output is instantaneous when setting is 0.
Start signal
Gate
Reset
Control output
Set value
UP
Set value
Timing diagram
DOWN
0
0
Mode A-3: Power ON delay 2 (Timer does not reset when power comes ON.)
Basic operationDetailed operation
Power
Powe r
Output
Timing starts when the reset input goes OFF.
The start signal disables the timing function (i.e.,
same function as the gate input).
The control output is controlled using a sustained or
one-shot time period.
Timing
Sustained
Note: Output is instantaneous when setting is 0.
Start signal
Gate
Reset
Control output
Set value
UP
Set value
Timing diagram
DOWN
0
0
t
ttt
20
Mode b: Repeat cycle 1 (Timer resets when power comes ON.)
Basic operationDetailed operation
Sustained Output
Power
Power
H5CX-A@-N/-L@-N
Timer
*
Start signal
input
Output
TimingTimingTimingTiming
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The status of the control output is reversed when time
is up (OFF at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact
output type).
Power
*
Start signal
input
Output
TimingTimingTimingTiming
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The control output is turned ON when time is up.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact
output type).
Start signal
Gate
Reset
Control output
Set value
UP
Set value
Timing diagram
DOWN
One-shot Output
Power
Start signal
Gate
Reset
Control output
Set value
UP
Set value
Timing diagram
DOWN
0
0
tt
0
0
Mode b-1: Repeat cycle 2 (Timer does not reset when power comes ON.)
Basic operationDetailed operation
Sustained Output
Power
*
Start signal
input
Output
Timing
TimingTiming Timing
Sustained
Timing
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The status of the control output is reversed when time
is up (OFF at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact
output type).
Power
*
Start signal
input
Output
Timing
TimingTiming Timing
Sustained
Timing
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The control output is turned ON when time is up.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact
output type).
One-shot Output
Power
Start signal
Gate
Reset
Control output
Set value
UP
Set value
Timing diagram
DOWN
Power
Start signal
Gate
Reset
Control output
Set value
UP
Set value
Timing diagram
DOWN
0
0
0
0
ttttt
21
H5CX-A@-N/-L@-N
Timer
Mode d: Signal OFF delay (Timer resets when power comes ON.)
Basic operationDetailed operation
Control output
Gate
0
0
Gate
0
0
Power
Start signal
Gate
Reset
Set value
UP
Set value
Timing diagram
DOWN
Power
*
Start signal
input
Output
Timing
* Start signal input is enabled during timing.
The control output is ON when the start signal is ON
(except when the power is OFF or the reset is ON).
The timer resets when the time is up.
Note: Output functions only during start signal input
when setting is 0.
Mode E: Interval (Timer resets when power comes ON.)
Basic operation Detailed operation
Power
*
Start signal
input
Output
Timing
* Start signal input is enabled during timing.
Timing starts when the start signal comes ON.
The timer resets when the time is up.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Output is disabled when the setting is 0.
Power
Start signal
Reset
Control output
Set value
UP
Set value
Timing diagram
DOWN
Mode F: Cumulative (Timer does not reset when power comes ON.)
Basic operationDetailed operation
Power
Start signal
input
Timing
Sustained
Output
Start signal enables timing (timing is stopped when the
start signal is OFF or when the power is OFF).
Timing
A sustained control output is used.
Note: Output is instantaneous when setting is 0.
When the H5CX is used with power start, there will be a
timer error (approximately 100 ms each time the H5CX
is turned ON) due to the characteristics of the internal
circuitry. Use the H5CX with signal start if timer
accuracy is required.
Power
Start signal
Reset
Control output
Set value
UP
Set value
Timing diagram
DOWN
Mode Z: ON/OFF-duty-adjustable flicker (Timer resets when power comes ON.)
Basic operation Detailed operation
0
0
Power
*
Start signal
input
Output
Timing
(cycle time)
Timing
ON duty
(%)
Timing
(cycle time)
Timing
ON duty
(%)
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The status of the control output is reversed when time is
up (ON at start).
While the start signal is ON, the timer starts when power
comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact output
type).
22
Power
Start signal
Gate
Reset
Control output
Cycle time
UP
ON duty setting
(%) ON time
Timing diagram
Cycle time
ON duty setting
(%) ON time
DOWN
0
0
Mode S: Stopwatch (Timer resets when power comes ON.)
Basic operationDetailed operation
H5CX-A@-N/-L@-N
Timer
Power
Start signal
input
Gate/Reset
Display
(for elapsed
time)
Timing
*
RST
*
flashes
The signal starts and stops timing.
The display is held and timing is continued if the reset
or gate input is received during timing operation.
The timer resets if the reset or gate input is received
when the timing operation is stopped.
Power
Start signal
Gate/Reset
Set time
UP
Timing diagram
Set time
DOWN
Output
9999
0
0
Note: Output is instantaneous when setting is 0.
Models with Instantaneous Contact OutputsEither one-shot output or sustained output can be selected.
Mode A-2: Power ON delay (Timer resets when power comes ON.)
Basic operationDetailed operation
Power
Time-limit
output
Instantaneous
output
The Timer starts when the power comes ON or when
the reset input goes OFF.
Timing
Note: Output is instantaneous when setting is 0.
Power
Reset Key
Time-limit
contacts, NC
Time-limit
contacts, NO
Instantaneous
contacts, NC
Instantaneous
contacts, NO
Mode b: Repeat cycle 1 (Timer resets when power comes ON.)
Basic operationDetailed operation
Power
t (time) t (time) t (time) t (time)
Time-limit
output
Instantaneous
output
The Timer starts when the power comes ON or when
the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms.
Note: H5CX-L8E@-N Precautions
Set the Timer’s set value before using the Timer in a self-holding circuit.
Reset Key
Time-limit
contacts, NC
ustained Output
S
Time-limit
contacts, NO
Time-limit
contacts, NC
One-shot Output
Time-limit
contacts, NO
Instantaneous
contacts, NC
Instantaneous
contacts, NO
t-a
t = Set time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.)
t-at-at-aRtRttttt-at-attt
Po
wer
t = Set time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.)
tt-at-aRtRtt
23
H5CX-A@-N/-L@-N
Timer
Mode E: Interval (Timer resets when power comes ON.)
Basic operation Detailed operation
Power
Time-limit
output
Instantaneous
output
The Timer starts when the power comes ON or when
the reset input goes OFF.
Timing
Note: Output is not instantaneous when setting is 0.
Power
Reset Key
Time-limit
contacts, NC
Time-limit
contacts, NO
Instantaneous
contacts, NC
Instantaneous
contacts, NO
Mode Z: ON/OFF-duty adjustable flicker (Timer resets when power comes ON.)
Basic operationDetailed operation
Po
wer
Timing (cycle time) Timing (cycle time)
Time-limit
output
Instantaneous
output
The Timer starts when the power comes ON or when
the reset input goes OFF.
Note: Normal output operation will not be possible if
Note: H5CX-L8E@-N Precautions
Timing
(ON duty)(ON duty)
the set time is too short.
Set the value to at least 100 ms.
Timing
Set the Timer’s set value before using the Timer in a self-holding circuit.
Power
Reset Key
Time-limit
contacts, NC
Time-limit
contacts, NO
Instantaneous
contacts, NC
Instantaneous
contacts, NO
t-a
t = Set time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.)
t-at-aRtRt
t = Set time, dty = ON duty time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.)
tt-at-aRtRtt
ttt-at-a
dtydtydtydty
t-a
24
Setting Procedure Guide
Operating Procedures for Twin Timer Function
H5CX-A@-N/-L@-N
Twin Timer
Step1
Step2
Switching to a Twin Timer
Power ON
1
+
Run mode
Hold down for 1 s min.
1
+
Hold down for 1 s min.
Settings for basic functions can be performed with just the DIP switch.
Note: There is no DIP switch on the H5CX-L8@. Go to .
Key-protect Switch
ItemOFFONOFF time rangePin 3Pin 2
DIP switch settings
1
2
OFF time range
3
4
ON time range
5
6
Output mode
7
Timer mode
Input signal width
8
Note: All the pins are factory-set to OFF.
Refer to the table on the right.
Refer to the table on the right.
Flicker OFF startFlicker ON start
Press the or Key to
Timer/twin timer
selection mode
DisabledEnabled
UPDOWN
20 ms1 ms
switch to a Twin Timer.
tim
Timer
ON
OFF
twn
Twin timer
Step3
Be sure to set pin 1 to ON when using the DIP switch.
12345678
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
0 min 01 s to 99 min 59 s
0 min 01 s to 99 min 59 s
0.01 s to 99.99 s
0.1 s to 999.9 s
1 s to 9999 s
ON time rangePin 5Pin 4
0.01 s to 99.99 s
0.1 s to 999.9 s
1 s to 9999 s
Be sure to turn ON pin 1 on the DIP switch.
Changes to DIP switch settings are enabled when the power is turned ON.
(Perform DIP switch settings while the power is OFF.)
After making DIP switch settings for basic operation, advanced functions can be added using the operation keys on the front panel. Refer to
Step3
on page 26 for details.
25
H5CX-A@-N/-L@-N
Twin Timer
To switch to twin timer operation, use the procedure given below. For details, refer to page 31.
Step3
Settings that cannot be performed with the DIP switch are performed with the operation keys.
• Change to Function Setting Mode.
Power ON
*1
3 s min.
Run mode
Function setting mode
*2
3 s min.
*1. If the mode is switched to the function setting mode during operation, operation will continue.
*2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode.
Also, when settings are changed, the timer is reset (time initialized and output turned OFF).
The characters displayed in reverse video are the default settings.
When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).
If pin 1 of the DIP switch is set to ON, the setting items indicated in will not be displayed.
OFF time
range
Set the OFF time range using the keys.
For details, refer to Time Range List.
ON time
range
Set the ON time range using the keys.
For details, refer to Time Range List.
Set the timer mode using the keys.
Timer mode
ON/OFF
start mode
Set the twin timer output mode using the keys.
For details on operations in run mode, refer to page 28.
s
s
updown
(DOWN)(UP)
sshs
sshs
……
……
tofftontof1ton1
Function setting mode
Input signal
width
Flicker
( ) ( ) ( ) ( )
OFF start 1
Note:
Only Flicker OFF Start 1 or Flicker ON Start 1 can be selected for the H5CX-L8E@.
Set the input signal width using the keys.
20ms
Note:
Not displayed for models with instantaneous contact outputs.
Flicker
On Start 1
1ms
(1 ms)(20 ms)
Flicker
OFF start 2
Flicker
On Start 2
Time Range List
DisplaySet Value
0.01 s to 99.99 s
(default setting)
0.1 s to 999.9 s
1 s to 9999 s
0 min 01 s to
99 min 59 s
0.1 min to
999.9 min
1 min to
9999 min
0 h 01 min to
99 h 59 min
0.1 h to 999.9 h
1 h to 9999 h
0.001 s to
9.999 s
26
NPN/PNP
input
Display
color
Instantaneous/
time-limit
From next pageTo next page
Set the NPN/PNP input mode using the keys.
npn
Note: Displayed only for the H5CX-A
pnp
(PNP input)(NPN input)
@ and H5CX-A11@.
Set the display color using the keys.
redorgr-gg-rr-oo-rg-oo-g
Note: Displayed only for models with terminal screws (H5CX-A
Set the function (instantaneous or time-limit operation) for the instantaneous output (output 1)
using the Keys.
(Instantaneous) (Time-limit)
Note: Displayed only for models with instantaneous contact outputs.
2c1c1c
H5CX-A@-N/-L@-N
Twin Timer
page
To previous
page
From previous
Function setting mode
Set value
upper limit 1
Set value
upper limit 2
Key protect
level
*1
Output ON
count alarm
set value/
monitor value
Set the digits for the set value limit using the corresponding keys.
9999
1
(9999)(1)
Set the digits for the set value limit using the corresponding keys.
99991
(9999)(1)
Set the key protect level using the keys.
kp-1
(KP-1)(KP-2)(KP-3)(KP-4)(KP-5)(KP-6)(KP-7)
kp-2
kp-3kp-4kp-5kp-6kp-7
*1. Set the digits for the output ON alarm set value using the corresponding
keys.
• Models without Instantaneous Contact Outputs
Output ON
count alarm
set value
(0 x 1000 times)
~
99990
(9999 x 1000 times)
Output ON
count monitor
value
Note: The monitor value is only displayed.
It cannot be set.
• Models with Instantaneous Contact Outputs
Instantaneous
output 1
(OUT1) ON
count alarm
set value
Instantaneous
output 2
(OUT2) ON
count alarm
set value
Instantaneous
output 1
(OUT1) ON
count monitor
value
Instantaneous
output 2
(OUT2) ON
count monitor
value
(0 x 1000 times)
(0 x 1000 times)
Note:
The monitor value is only displayed.
It cannot be set.
Note:
The monitor value is only displayed.
It cannot be set.
~
99990
(9999 x 1000 times)
~
99990
(9999 x 1000 times)
27
H5CX-A@-N/-L@-N
Twin Timer
Explanation of Functions
Operating Procedures for Twin Timer Function
Items marked with stars () can be set using the DIP switch.
OFF Time Range (oftr)
Set the time range for the OFF time in the range 0.000 s to 9,999 h.
Only settings of type --.-- s (99.99 s), ---.- s (999.9 s), ---- s (9,999 s),
and -- min -- s (99 min 59 s) can be made with the DIP switch. Use the
operation keys if another type of setting is required.
ON Time Range (ontr)
Set the time range for the ON time in the range 0.001 s to 9,999 h.
Only settings of type --.-- s (99.99 s), ---.- s (999.9 s), ---- s (9,999 s),
and -- min -- s (99 min 59 s) can be made with the DIP switch. Use the
operation keys if another type of setting is required.
Timer Mode (timm)
Set either the elapsed time (UP) or remaining time (DOWN) mode.
In UP mode, the elapsed time is displayed, and in DOWN mode, the
remaining time is displayed.
ON/OFF Start Mode (totm)
Set the output mode.
Set either flicker OFF start or flicker ON start. (For details on output
mode operation, refer to "Timing Charts" on page 29.)
Input Signal Width (iflt)
Set the minimum signal input width (20 ms or 1 ms) for signal, reset,
and gate inputs.
The same setting is used for all external inputs (signal, reset, and gate
inputs).
If contacts are used for the input signal, set the input signal width to
20 ms.
Processing to eliminate chattering is performed for this setting.
NPN/PNP Input Mode (imod)
Select either NPN input (no-voltage input) or PNP input (voltage input)
as the input format. Set an NPN input when using a 2-wire sensor.
The same setting is used for all external inputs.
For details on input connections, refer to "Input Connections" on
page 9.
Display Color (colr)
(Terminal black model: H5CX-A@ only)
Set the color used for the present value.
Key Protect Level (kypt)
Set the key protect level.
Refer to “Key Protect Level” on page 32.
red
grn
org
r-g
g-r
r-o
o-r
g-o
o-g
Output OFFOutput ON
Red (fixed)
Green (fixed)
Orange (fixed)
RedGreen
GreenRed
RedOrange
OrangeRed
GreenOrange
OrangeGreen
Operation in Run Mode
Operating Procedures for Twin Timer Function
Present value
OFF set time
Present value
ON set time
Note: 1. The display will automatically show the OFF set time when the OFF time is being timed and the ON set time when the ON time is being timed.
Note: 2. H5CX-L8E@-N Precautions
Set the Timer’s set value before using the Timer in a self-holding circuit.
Present Value and OFF Set Time
The present value is displayed in the main display and the OFF set
time is displayed in the sub-display. Set the OFF time.
Set the digits for the OFF set time using the corresponding keys.
Set the digits for the ON set time using the corresponding keys.
Present Value and ON Set Time
The present value is displayed in the main display and the ON set
time is displayed in the sub-display. Set the ON time.
28
Timing Charts
Operating Procedures for Timer Function
Models without Instantaneous Contact Outputs
The gate input is not included in the H5CX-L8@ models.
Mode toff: Flicker OFF start 1 (Timer resets when power comes ON.)
Basic operationDetailed operation
H5CX-A@-N/-L@-N
Twin Timer
Power
Start signal
input
Output
*
Timing
OFF
Timing ONTiming
OFF
Timing
ON
Power
Start signal
Gate
Reset
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The status of the control output is reversed when time is
up (OFF at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact output
type).
Control output
OFF time
UP
ON time
OFF time
Timing diagram
DOWN
ON time
0
0
Mode ton: Flicker OFF start 1 (Timer resets when power comes ON.)
Basic operationDetailed operation
Power
Start signal
input
Output
*
Timing ONTiming
OFF
Timing ONTiming
OFF
Power
Start signal
Gate
Reset
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The status of the control output is reversed when time is
up (ON at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact output
type).
Control output
OFF time
UP
ON time
OFF time
Timing diagram
DOWN
ON time
0
0
Mode toff-1: Flicker OFF start 2 (Timer does not reset when power comes ON.)
Basic operationDetailed operation
Power
*
Start signal
Output
input
Timing
OFF
Timing ONTiming
OFF
ab
(a + b = ON time)
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The status of the control output is reversed when time is
up (OFF at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact output
type).
Power
Start signal
Gate
Reset
Control output
OFF time
UP
ON time
OFF time
Timing diagram
DOWN
ON time
0
0
29
H5CX-A@-N/-L@-N
Twin Timer
Mode ton-1: Flicker ON start 2 (Timer does not reset when power comes ON.)
Basic operationDetailed operation
Power
Start signal
input
Output
*
Timing ONTiming
OFF
Timing
ON
ab
(a + b = OFF time)
Power
Start signal
Gate
Reset
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The status of the control output is reversed when time is
up (ON at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact output
type).
Control output
OFF time
UP
ON time
OFF time
Timing diagram
DOWN
ON time
Models with Instantaneous Contact Outputs
Mode toff: Flicker OFF start 1 (Timer resets when power comes ON.)
Basic operationDetailed operation
Power
Time-limit
output
Instantaneous
output
Ton timeToff timeTon timeToff time
The Timer starts when the power comes ON or when
the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the ON time and OFF time to at least 100
ms.
Mode ton: Flicker ON start 1 (Timer resets when power comes ON.)
Basic operationDetailed operation
Power
Ton time
Time-limit
output
Instantaneous
output
The Timer starts when the power comes ON or when
the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the ON time and OFF time to at least 100
ms.
Note: H5CX-L8E@-N Precautions
Set the Timer’s set value before using the Timer in a self-holding circuit.
Select whether the H5CX is used as a timer or a twin timer in timer/twin timer selection mode.
The H5CX is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be
confirmed using the front display.
Power ON
KeyKey
1
Run modeTimer/Twin Timer Selection Mode
*2*1
1 s min.
Caution
+
1
Timer/Twin
timer selection
DIP switch
monitor
Convenient
To change the mode to timer/twin timer selection mode,
hold down the key for 1 s min. with the key held
down. The key must be pressed before the key. If the
key is pressed first, the mode will not change.
Select either timer operation or twin timer operation using the
keys.
Note: The H5CX is factory-set for timer operation.
Confirm the status of DIP switch pins 1 to 8 using the keys.
Note: 1. This display is not supported with H5CX-L8@-N.
2. This display is only possible when DIP switch pin 1 (DIP switch settings
enable/disable) is set to ON (enable).
tim
1
1
twn
Example
ON
OFF
12345678
Indicates that DIP switch pin 8 is ON.
Indicates that DIP switch pin 7 is OFF.
Indicates that DIP switch pin 6 is ON.
Indicates that DIP switch pin 5 is OFF.
Indicates that DIP switch pin 4 is ON.
Indicates that DIP switch pin 3 is OFF.
Indicates that DIP switch pin 2 is ON.
Indicates that DIP switch pin 1 is ON.
*1. When the mode is changed to timer/twin timer selection mode, the present value is reset and output turns OFF.
Timing operation is not performed in timer/twin timer selection mode.
*2. Setting changes made in timer/twin timer selection mode are enabled when the mode is changed to run mode.
If settings are changed, the HC5X is automatically reset (present value initialized, output turned OFF).
31
H5CX-A@-N/-L@-N
Key Protect Level
When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the
key protect level (KP-1 to KP-7).
The key protect indicator is lit while the key-protect switch is set to ON.
*
(Disabled)
* Factory-set to OFF
OFF
ON
(Enabled)
Key protect indicator
LevelMeaning
KP-1
(default setting)
KP-2InvalidValidInvalidValid
KP-3InvalidValidValidInvalid
KP-4InvalidValidInvalidInvalid
KP-5InvalidInvalidInvalidInvalid
KP-6InvalidInvalidValidValid
Changing mode*
InvalidValidValidValid
Switching display
during operation
Details
Reset Key
Up/down key
KP-7InvalidInvalidInvalidValid
* Changing mode to Timer/Twin Timer Selection Mode or Function Setting Mode.
Self-diagnostic Function
The following displays will appear if an error occurs.
Main displaySub-displayErrorOutput statusCorrection methodSet value after reset
e1
e2
e2sum
*2
e3
*1. This includes times when the life of the EEPROM has expired.
*2. The normal display and
When the Reset Key is pressed,
continue without clearing the output ON count.)
Not litCPUOFF
Not litMemory error (RAM)OFFReset the power supply. No change
Memory error EEPROM
No change
will appear alternately.
e3
e3
Output ON count alarm set
value exceeded
will no longer be displayed even if the alarm set value is exceeded. (Monitoring is possible, however, because the Timer will
32
Either press the reset key or
reset the power supply.
*1
OFFReset KeyFactory setting
No changeReset KeyNo change
No change
H5CX-B@-N
Digital Timer H5CX-B@-N
• H5CX Digital Timers with 6-digit Display, 2-stage Setting,
and Forecast Output (DIN 48 x 48-mm)
• Times the daily operating hours of machinery and tools,
predicting and notifying when maintenance is required.
• Easy-to-read backlit negative LCD with 6 digits (displays
to 99999.9 h).
• The 2-stage settings and forecast output are ideal for
maintenance applications.
Specifications
Ratings
Classification Digital Timer with 6-digit display, 2-stage setting, and forecast output
Power supply voltage12 to 24 VDC
Ratings
Mounting methodFlush mounting
External connectionsScrew terminals
Degree of protection IEC IP66, UL508 Type 4X (indoors) for panel front surface only and only when Y92S-29 Waterproof Packing is used
Digits 6 digits
Time range0.01 s to 9999.99 s, 1 s to 99 h 59 min 59 s, 0.1 min to 99999.9 min, 0.1 h to 99999.9 h
Timer mode Elapsed time (Up)
Inputs
Reset systemPower resets (only for A mode), external and manual reset
Power reset Minimum power-opening time: 0.5 s (except for F-1 mode)
Reset voltage 10% max. of rated supply voltage
Sensor waiting time250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Outputs
Display
Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature range-10 to 55°C (-10 to 50°C if counters are mounted side by side) (with no icing or condensation)
Storage temperature range-25 to 70°C (with no icing or condensation)
Operating humidity range 25 to 85%
Case color Black (N1.5)
Attachments Waterproof packing, flush mounting adapter, unit label
*1. Inrush current will flow for a short time when the power supply is turned ON.
Inrush Current (Reference Values)
*2. The display is lit only when the power is ON.
Operating voltage
fluctuation range
Power consumptionApprox. 2.3 W
Input signalsSignal, reset, gate
Input method
Signal, reset, gateMinimum input signal width: 1 or 20 ms (selectable, same for all input)
Output modes A, F-1
Output type
VoltageApplied voltage Inrush current (peak value) Time
12 to 24 VDC26.4 VDC4.4 A1.7 ms
90% to 110% rated supply voltage
*1
No-voltage InputON impedance: 1 kΩ max. (Leakage current: 12 mA when 0 Ω)
Accuracy of operating time
and setting error
(including temperature and
voltage influences)
Insulation resistance 100 MΩmin. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration
resistance
Shock
resistance
Weight Approx. 105 g (Timer only)
Destruction10 to 55 Hz with 0.75-mm single amplitude in three directions for 2 h each
Malfunction10 to 55 Hz with 0.35-mm single amplitude in three directions for 10 min each
Destruction300 m/s2 in three directions, three cycles
Malfunction100m/s2 in three directions, three cycles
Applicable Standards
Approved safety standards
EMC
Signal start: ±0.005%±0.03 ms max. (See note 1.)
Signal start for transistor output model: ±0.005%±3 ms max. (See note 1 and 2.)
If the set value is within the sensor waiting time at startup the control output of the H5CX will not turn ON until the sensor waiting
time passes.
Note: 1. The values are based on the set value.
2. The value is applied for a minimum pulse width of 1 ms.
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts
1,000 VAC, 50/60 Hz for 1 min between control output, power supply, and input circuit
1.0 kV (between power terminals)
1.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
±480 V (between power terminals) and ±600 V (between input terminals), square-wave noise by noise simulator
(pulse width: 100 ns/1 µs, 1-ns rise)
Destruction: 15 kV
Malfunction: 8 kV
UL508/Listing, CSA C22.2 No. 14, conforms to EN 61812-1 (pollution degree 2/overvoltage category III)
Conforms to VDE0106/P100 (finger protection).
(EMI)
Emission Enclosure:
(EMS)
Immunity ESD:
Immunity RF-interference:
Immunity Conducted Disturbance:
Immunity Burst:
Immunity Surge:
EN61812-1
EN55011 Group 1 class A
EN61812-1
EN61000-4-2: 6 kV contact discharge (level 2)
3. Terminals 7 and 10 have the same
reset function. The same function will
be performed whichever terminal is
connected. Terminals 7 and 10 are
not connected internally, however, so
do not use them for cross-over wiring.
from the internal circuitry
by a photocoupler, so the
transistor output can be
used as both NPN and
PNP output.
• The diode connected to
the collector of the output
transistor is used to
absorb inverted voltage
that is generated when an
inductive load is
connected to the H5CX.
+
Power for load
Timer
Load
+
Power for load
Load
Inductive
load
Input Connections
The inputs of the H5CX-B are no-voltage (short-circuit or open) inputs or voltage inputs.
No-voltage Inputs (NPN Inputs)
Open CollectorVoltage OutputContact InputDC Two-wire Sensor
Internal
circuit
+
Power for load
PLC or
sensor
Gate
Reset
Signal
0 V for inputs
6789
Note: Operate with transistor ON
10
Reset
Sensor
Gate
Signal
Reset
10
Reset
0 V for inputs
6789
Note: Operate with transistor ON
Gate
Reset
Signal
0 V for inputs
6789
Note: Operate with relay ON
10
Reset
No-voltage Input Signal Levels
Short-circuit level (Transistor ON)
• Residual voltage: 3 V max.
No-contact
input
Contact inputUse contacts which can adequately switch 5 mA at 10 V
• Impedance when ON: 1 kΩ max.
(The leakage current is approx. 12 mA when the impedance is 0 Ω.)
Forecast value setting
Forecast output ON: OUT 1 is lit.
Control output ON: OUT 2 is lit.
Absolute value setting
Control output 1 ON: OUT 1 is lit.
Control output 2 ON: OUT 2 is lit.
3. Reset Indicator
(orange)
Lit when the reset input or Reset Key is ON.
4. Present Value Display
Character height: 10 mm
If the time range is 0.0 min or 0.0 h, the decimal
point flashes to indicate timing operation.
5. Time Unit Indicators
6. Set Value
Character height: 6 mm
(green)
7. Set Value 1, 2 Indicator
Character Size
for Present
Value Display
10mm
Character Size
for Set Value
Display
(green)
6mm
(orange)
(orange)
(red)
(green)
1
2
3
8
9
11
Key Protect Level
When the Key-protect Switch is ON, key operations are prohibited
according to the settings for DIP switch pins 6 to 8, thus preventing
setting errors.
The Key-protect Switch can be turned ON and OFF while the power
is ON.
Operation Key
8. Mode Key
4
5
6
7
10
First digitSixth digit
12
(Changes modes and setting items)
9. Reset Key
Resets present value and output.
10. Up Keys 1 to 6
Switches
11. Key-protect Switch
(Default setting)
OFF
(Disabled)
ON
(Enabled)
12. DIP Switch
ON
OFF
12345678
The Key Protection Indicator is lit orange when the Key-protect Switch
is ON.
If the key protect switch is ON, you will not be able to switch to
Function Setting Mode.
H5CX-BWSD-N (Provided with Adapter and Waterproof Packing)
Y92F-30 (provided)
Pane lY92S-29 (provided)
Waterproof Packing
58
48
(51)
7.557.5
Flush Mounting Adapter
Accessories (Order Separately)
Refer to page 12 for details.
44.8×44.8
Panel Cutouts
Panel cutouts areas shown below. (according
to DIN43700)
60 min.
+0.6
45
–0
+0.6
45
–0
15 min.
60 min.
Note: 1. The mounting panel thickness should
be 1 to 5 mm.
2. To allow easier operation, it is
recommended that Adapters be
mounted so that the gap between
sides with hooks is at least 15 mm
(i.e., with the panel cutouts separated
by at least 60 mm).
3. It is possible to mount Timers side by
side, but only in the direction without
the hooks. However, if Timers are
mounted side by side, water
resistance will be lost.
n side by side mounting
A
A= (48n–2.5)
–0
With Y92A-48F1 attached.
A={48n–2.5+(n–1)×4}
–0
With Y92A-48 attached.
A= (51n–5.5)
–0
+1
+1
+1
36
Operating Procedures
DIP Switch Settings
All functions are set using the DIP switch.
ItemOFFON
1
Time range
2
3 Output modes F-1 mode
4 Input signal width 20 ms1 ms
5 NPN/PNP input mode
6 Reset Key protection Disabled Enabled
7 Up Key protection Disabled Enabled
8 Mode Key protection Disabled Enabled
Note: 1. All the pins are factory-set to OFF.
2. DIP switch settings are effective when the power is
turned ON again. (Set the DIP switch before installation
and power-up.)
Refer to the table on the
right.
A mode
NPN
(no-voltage)
PNP
(voltage)
Operation in Run Mode
Set the digits for the set values using the corresponding Key.
Pin 1 Pin 2Time range
OFFOFF0.1 h to 99999.9 h
ONOFF0.01 s to 9999.99 s
OFFON
ONON0.1 min to 99999.9 min
0 h 00 min 01 s to
99 h 59 min 59 s
ON
OFF
12345678
H5CX-B@-N
Forecast Value SettingAbsolute Value Setting
Present value
Set value
Present value
Forecast set value
Each time the Key is pressed,
the sub-display will switch between
the set value (“SET” is lit) and the
forecast set value (“1” is lit).
Present value
Set value 1
Present value
Set value 2
Each time the Key is pressed,
the sub-display will switch between
set value 1 (“SET 1” is lit) and set
value 2 (“SET 2” is lit).
37
H5CX-B@-N
Operation in Function Setting Mode
Settings that cannot be performed with the DIP switch are performed with the operation keys.
• Change to Function Setting Mode.
Power ON
*1
3 s min.
Run mode
*1. If the mode is switched to the function setting mode during operation, operation will continue.
*2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode.
Also, when settings are changed, the timer is reset (time initialized and output turned OFF).
Function setting mode
*2
3 s min.
Function Setting Mode
Absolute
value setting/
forecast value
setting
Set value
upper limit
Forecast
setting upper
limit
Output 1
(OUT1)
ON count
alarm set value
Output 2
(OUT2)
ON count
alarm set value
Set the digits for the set values using the
corresponding Key.
~
(Forecast
value setting)
Set the digits for the set values using the
corresponding Key.
(Absolute
value setting)
~
(1)
Set the digits for the set values using the
corresponding Key.
(999999)
~
(1)
Note: Displayed only in forecast setting mode.
Set the digits for the set values using the
corresponding Key.
(999999)
~
times)
(9999 x 1000
times)
(0 x 1000
Set the digits for the set values using the
corresponding Key.
~
times)
(9999 x 1000
times)
(0 x 1000
38
Output 1
(OUT1)
ON count
monitor value
Output 2
(OUT2)
ON count
monitor value
Note: The monitor value is only displayed. It cannot be set.
Note: The monitor value is only displayed. It cannot be set.
Explanation of Functions
Absolute value setting/forecast value setting
(setm)
Set value 1 can be set as the forecast value setting (ofst) or the
absolute value setting (
Forecast Value Setting
Forecast
set value
• OUT1 (forecast output) turns ON when the present value reaches
the forecast value.
Forecast value = Set value - Forecast set value
Note: The forecast set value is used to set the deviation for the set value.
• OUT2 (control output) turns ON when the present value reaches
the set value.
• If the forecast set value ≥ set value, OUT1 (forecast output) will turn
ON as soon as timing starts.
value
Forecast
value
Forecast output
(OUT1)
Control output
(OUT 2)
abs).
Example: F-1 Mode
Set
0
Present
value
H5CX-B@-N
Absolute Value Setting
Example: F-1 Mode
Set value 2
Set value 1
0
Control output 1
(OUT1)
Control output 2
(OUT2)
• OUT1 (control output 1) turns ON when the present value reaches
set value 1.
• OUT2 (control output 2) turns ON when the present value reaches
set value 2.
Refer to pages 18 and 28 for information on other functions.
Present
value
Self-diagnostic Function
The following displays will appear if an error occurs.
Main displaySub-displayErrorOutput statusCorrection method Set value after reset
e1
e2
e2sum
*2
e3
*1. This includes times when the life of the EEPROM has expired.
*2. The normal display and
When the Reset Key is pressed,
continue without clearing the output ON count.)
Not litCPU OFF
Not litMemory error (RAM) OFFReset the power supply. No change
will no longer be displayed even if the alarm set value is exceeded. (Monitoring is possible, however, because the Timer will
No change Reset Key No change
Either press the Reset Key or
reset the power supply.
No change
39
H5CX-B@-N
g
Timing Charts
Mode A: Signal ON delay (Timer resets when power comes ON.)
Basic operationDetailed operation
Power
Start signal input
Forecast
output
OUT1
Control
output
OUT2
( ) The names in parentheses are used for the absolute value setting.
* Start signal input is disabled during timing.
• Timing starts when the start signal goes ON.
• While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
• A sustained control output is used.
• Timing stops when the time is up.
Note: Output is instantaneous when the set value is 0.
Mode F-1: Cumulative (Timer does not reset when power comes ON.)
Basic operation Detailed operation
Start signal input
Forecast
output
OUT1
Control
output
OUT2
( ) The names in parentheses are used for the absolute value settin
• Start signal enables timing (timing is stopped when the
start signal is OFF or when the power is OFF).
• A sustained control output is used.
• Timing continues even after the time is up.
Note: Output is instantaneous when the set value is
When the H5CX is used with power start, there will be
a timer error (approximately 100 ms each time the
H5CX is turned ON) due to the characteristics of the
internal circuitry. Use the H5CX with signal start if
timer accuracy is required.
Note: 1. The forecast value = set value - forecast set value
*
Control
output 1
(
)
OUT1
Control
output 2
(
)
OUT2
Power
Control
output 1
(
)
OUT1
Control
output 2
(
)
OUT2
0.
2. The forecast set value is used to set the deviation for the set value.
Timing
TimingTiming
Sustained
Set value (SV 2)
Forecast value
Timing diagram
The names in parentheses are used for the absolute value setting.
Power
Start signal
Gate
.
Timing diagram
Reset
999999
Set value (SV 2)
Forecast value
(SV 1)
OUT1
OUT2
The names in parentheses are used for the absolute value setting.
Power
Start signal
Gate
Reset
999999
(SV 1)
OUT1
OUT2
0
0
40
Safety Precautions for All H5CX Series (Common)
H5CX-@-N
CAUTION
Do not allow pieces of metal, wire clippings, or fine
metallic shavings or fillings from installation to enter
the product. Doing so may occasionally result in
electric shock, fire, or malfunction.
Minor injury due to explosion may occasionally occur.
Do not use the Timer where subject to flammable or
explosive gas.
Fire may occasionally occur. Tighten the terminal
screws to the rated torque.
H5CX terminals: 6.55 to 7.97 lb-in (0.74 to 0.90 N m)
P2CF Socket terminals: 4.4 lb-in (0.5 N m)
Minor injury due to electric shock may occasionally
occur. Do not touch any of the terminals while power
is being supplied. Be sure to mount the terminal cover
after wiring.
The life expectancy of the output relay varies
considerably according to its usage. Use the output
relay within its rated load and electrical life
expectancy. If the output relay is used beyond its life
expectancy, its contacts may become fused or there may be a
risk of fire. Also, be sure that the load current does not exceed
the rated load current and when using a heater, be sure to use a
thermal switch in the load circuit.
Minor electric shock, fire, or malfunction may
occasionally occur. Do not disassemble, modify, or
repair the Timer or touch internal components.
•
•
Precautions for Safe Use
• The panel surface of the H5CX is water-resistant (conforming to
NEMA4, IP66, UL Type 4X (Indoor Use Only). To protect the
internal circuits from water penetration through the space between
the H5CX and operating panel, waterproof packing is included.
Attach the Y92F-30 Adapter with sufficient pressure with the
reinforcing screws so that water does not penetrate the panel.
0.5 to 1 mm
It is recommended that the
space between the screw
head and the Adapter be 0.5
to 1 mm.
• When mounting the Timer to a panel, tighten the two mounting
screws alternately, a little at a time, so as to keep them at an equal
tightness. If the panel screws are tightened unequally, water may
enter the panel.
• Store the Timer at the specified temperature. If the Time has been
stored at a temperature of less than -10°C, allow the Time to stand
at room temperature for at least 3 hours before use.
• Mounting the Timer side-by-side may reduce the life expectancies
of internal components.
• Use the Timer within the specified ranges for the ambient operating
temperature and humidity.
• Do not use in the following locations:
• Locations subject to sudden or extreme changes in
temperature.
• Locations where high humidity may result in condensation.
• Do not use the Timer outside of the rated ranges for vibration,
shock, water exposure, and oil exposure.
• Do not use this Timer in dusty environments, in locations where
corrosive gasses are present, or in locations subject to direct
sunlight.
• Install the Timer well away from any sources of static electricity,
such as pipes transporting molding materials, powders, or liquids.
• Internal elements may be destroyed if a voltage outside the rated
voltage range is applied.
• Be sure that polarity is correct when wiring the terminals.
• Separate the Timer from sources of noise, such as devices with
input signals from power lines carrying noise, and wiring for I/O
signals.
• Do not connect more than two crimp terminals to the same
terminal.
• Up to two wires of the same size and type can be inserted into a
single terminals.
• Use the specified wires for wiring. Applicable Wires: AWG 18 to
AWG 22, solid or twisted, copper.
• Install a switch or circuit breaker that allows the operator to
immediately turn OFF the power, and label it to clearly indicate its
function.
• When the Timer is operated with no-voltage input (NPN input),
approximately 14 V is output from the input terminals. Use a sensor
that contains a diode.
Sensor
Input0V
• Use a switch, relay, or other contact so that the rated power supply
voltage will be reached within 0.1 seconds. If the power supply
voltage is not reached quickly enough, the Timer may malfunction
or outputs may be unstable.
• Use a switch, relay, or other contact to turn the power supply OFF
instantaneously. Outputs may malfunction and memory errors may
occur if the power supply voltage is decreased gradually.
•H5CX-A@-N/-L@-N:
When changing the set value during a timing operation, the output
will turn ON if the set value is changed as follows because of the
use of a constant read-in system:
Elapsed time (UP) mode: Present value
Remaining time (DOWN) mode: Elapsed time
present value is set to 0.)
When in the remaining time mode, the amount the set value is
changed is added to or subtracted from the present value.
Operation with a set value of 0 will vary with the output mode. Refer
to the timing charts on page 20.
•H5CX-B@-N:
When changing the set value during a timing operation, the output
will turn ON if the set value is changed as follows because of the
use of a constant read-in system:
1. Forecast Value Setting
When the present value
turns ON.
When the present value
set value - forecast set value), OUT1 (forecast output) turns ON.
2. Absolute Value Setting
When the present value
turns ON.
When the present value
set value - forecast set value), OUT1 (control output 1) turns
ON.
When the set value is 0, the output turns ON the moment the
signal is input. The reset operation turns OFF the output.
• Do not use organic solvents (such as paint thinners or benzine),
strong alkali, or strong acids. They will damage the external finish.
• Confirm that indications are working normally, including the
backlight LED, and LCD. The indicator LEDs, LCD, and resin parts
may deteriorate more quickly depending on the application
environment, preventing normal indications. Periodic inspection
and replacement are required.
• The waterproof packing may deteriorate, shrink, or harden
depending on the application environment. Periodic inspection and
replacement are required.
≥ the set value, OUT2 (control output)
≥ the forecast value (forecast value =
≥ set value 2, OUT2 (control output 2)
≥ the forecast value (forecast value =
Diode
≥ Set value
≥ Set value (The
41
H5CX-@-N
Precautions for Correct Use
• H5CX models with a 24-VDC/12 to 24-VDC power supply use a
transformer-free power supply method in which the power supply
terminals are not isolated from the signal input terminals. If a nonisolating DC power supply is used, unwanted current paths may
occasionally burn or destroy internal components depending on
the wiring. Always check the wiring sufficiently before use.
• An inrush current of approx. 10 A will flow for a short time when the
power supply is turned ON. If the capacity of the power supply is
not sufficient, the Timer may not start. Be sure to use a power
supply with sufficient capacity.
• Maintain voltage fluctuations in the power supply within the
specified operating voltage range.
• When turning the power ON and OFF, input signal reception is
possible, unstable, or impossible as shown in the diagram below.
ON
Power
supply
OFF
200ms5ms0 to 50 ms0 to 500 ms
Input Impossible
• To allow for the startup time of peripheral devices (sensors, etc.),
the Timer starts timing operation between 200 to 250 ms after
power is turned ON. For this reason, in operations where timing
starts from power ON, the time display will actually start from 249
ms. If the set value is 249 ms or less, the time until output turns ON
will be a fixed value between 200 and 250. The present value
display will start from 250 ms. (Normal operation is possible for set
values of 250 ms or more.) In applications where a set value of 249
ms or less is required, use start timing with signal input.
• Inrush current generated by turning ON or OFF the power supply
may deteriorate contacts on the power supply circuit. Turn ON or
OFF to a device with the rated current of more than 10 A.
• Make sure that all settings are appropriate for the application.
Unexpected operation resulting in property damage or accidents
may occur if the settings are not appropriate.
• Do not leave the Timer for long periods at a high temperature with
output current in the ON state. Doing so may result in the
premature deterioration of internal components (e.g., electrolytic
capacitors).
• EEPROM is used as backup memory when the power is
interrupted. The write life of the EEPROM is 100,000 writes.
The EEPROM is written at the following times:
• When the power supply is turned OFF
• When switching from Timer/Twin Timer Selection Mode or
Function Setting Mode to Run Mode
• Dispose of the product according to local ordinances as they apply.
• Attach the front panel when using the Timer. The tabs in the middle
of each of four sides secure the front panel to the main body. To
remove the panel, widen the four tabs and pull the panel toward
you. To mount the panel, fit all four tabs correctly into the grooves
on the main body.
Unstable
Possible
Unstable Impossible
Conformance to EN/IEC Standards
• When conforming to EMC standards, refer to the information
provided in this datasheet for cable selection and other conditions.
• This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take
adequate measures to reduce interference.
•H5CX-A@-N/-L@-N:
Basic insulation is provided between the power supply and input
terminals. (No insulation is provided between the power supply and
input terminals for the H5CX-@D-N.)
Basic insulation is provided between power supply and output
terminals, and between input and output terminals.
•H5CX-B@-N:
No insulation is provided between the power supply and input
terminals.
Basic insulation is provided between the power supply and output
terminals.
• When double insulation or
double insulation or reinforced insulation as defined in IEC 60664
that is suitable for the maximum operating voltage with clearances
or solid insulation.
• Connect the input and output terminals to devices that do not have
any exposed charged parts.
reinforced insulation is required, app
ly
42
Ta bs
Grooves
Warranty and Application Considerations
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or
other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS,
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of
products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR
SYSTEM.
Disclaimers
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a
warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with
your OMRON representative at any time to confirm actual specifications of purchased product.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON Corporation Industrial Automation Company
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200