Please read and understand this catalog before purchasing the
products. Please consult your OMRON representative if you have any
questions or comments. Refer to Warranty and Application Considerations (page 8) and Safety Precautions (page 7).
Large Setting Dial and Moving Pointers Ideal
for Easy Operation and Monitoring
• Incorporating an easy-to-see large setting dial with moving
pointers.
• Wide time-setting range of 0.2 s to 60 h (available through three
time-range model types)
• Wide AC power supply range (100 to 240 VAC)
• IP65 watertight and dust-tight front panel.
• Approved by UL and CSA.
• Conforms to EN61812-1 and IEC60664-1
4 kV for Low Voltage, and EMC Directives.
• Conforms to EMC standards.
• Six-language instruction manual provided.
• Programmable contact enables the building of a self-holding
relay circuit as well as built-in instantaneous contact. (-NS)
• Memory retention (-NSR)
• Finger protection terminal block
• Enables easy sequence checks through instantaneous outputs
for a zero set value at any time range.
Model Number Legend
H3AM - NS
12-3
1. Resetting System
None: Self-resetting
R: Electric resetting
-
2. Time Range
A: 0.5 s to 30 h
B: 1 s to 60 h
C: 0.2 s to 12 h
3. Accessory
None: Without accessory
300: Waterproof Packing
(Y92S-35) provided
Ordering Information
■ List of Models
Rated supply
voltage
100 to 240
VAC
Note: The operation of the instantaneous contacts differs for the self-resetting and electric resetting systems. Refer to Timing Charts on page 5
for details.
Resetting
system
(See note.)
Self-resettingDPDT contact output
Electric
resetting
Control outputTime range
(Time-limit output SPDT and
switchable SPDT
(time-limit
DPDT contact output
(Time-limit output SPDT and
instantaneous output SPDT)
↔ instantaneous))
0.5 s to 30 h (30 s, 3 min,
30 min, 3 h, 30 h)
H3AM-NS-AH3AM-NS-BH3AM-NS-C
H3AM-NSR-AH3AM-NSR-BH3AM-NSR-C
1 s to 60 h (60 s, 6 min,
60 min, 6 h, 60 h)
0.2 s to 12 h (12 s, 120 s,
12 min, 120 min, 12 h)
Mechatronic Analog Timer H3AM1
■ Accessory (Order Separately)
ItemModel
Waterproof PackingY92S-35 (See note.)
Note: Supplied with H3AM-NS@-@-300 models.
Specifications
■ General
Operating modeON-delay
Screw tightening torque0.98 N·m (10 kgf) max.
Input typeVoltage input
Output typeRelay: DPDT
Mounting methodFlush/Panel mounting, no restriction on mounting angle.
Approved standardsUL 508, CSA C22.2 No. 14
■ Time Ranges
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100
Output category according to IEC60947-5-1
ModelFull scale on
H3AM-@@@-A3---0.5 to 30 s0.05 to 3 min0.5 to 30 min0.05 to 3 h0.5 to 30 h
H3AM-@@@-B6---1 to 60 s0.1 to 6 min1 to 60 min0.1 to 6 h1 to 60 h
H3AM-@@@-C120.2 to12 s2 to 120 s0.2 to 12 min2 to 120 min0.2 to 12 h---
Note: Instantaneous output is obtained by turning the time setting knob below "0" until the time setting knob stops.
dial
s10 smin10 minh (hour)10 h (hour)
Set time unit
■ Ratings
Rated supply voltage100 to 240 VAC (50/60 Hz)
Operating voltage range85% to 110% of rated supply voltage
Power reset (-NS)Minimum power-opening time: 0.5 s
Reset input time (-NSR)Minimum input time: 0.5 s
Reset voltage range (-NSR) H level: 85 to 264 VAC
Power consumptionApprox. 9 VA (Approx. 5 W)
Control outputContact output: 5 A at 250 VAC, resistive load (cos
Ambient temperatureOperating: –10
Ambient humidityOperating: 35% to 85%
Note: The minimum applicable load:
H3AM-NS: 10 mA at 5 VDC (failure level: P, reference value)
H3AM-NSR: 100 mA at 5 VDC (failure level: P, reference value)
L level: 0 to 10 VAC
Storage: –25
°C to 55°C (with no icing)
°C to 65°C (with no icing)
φ = 1)
2Mechatronic Analog TimerH3AM
■ Characteristics
Accuracy of operating time
Setting error
Reset timePower reset: 0.5 s max.
Influence of voltage
Influence of temperature
Insulation resistance100 M
Dielectric strength2,000 VAC (50/60 Hz) for 1 min between exposed non-current-carrying metal parts and current-carrying metal parts
Impulse withstand voltage 3 kV between power terminals
Noise immunity
Static immunityMalfunction: 8 kV
Vibration resistanceDestruction: 10 to 55 Hz, 0.75-mm single amplitude for 2 cycles each in 3 directions (8 min per cycle)
Shock resistance
Life expectancyMechanical: 5,000,000 times min. (under no load at 1,800 times/h)
Motor life expectancy20,000 h
EMC(EMI): EN61812-1
Enclosure ratingIP65 (front panel only) (See note.) IP20 (terminal section)
WeightApprox. 350 g
Note: A separately sold waterproof packing (Y92S-35) is necessary to ensure IP65 waterproofing between the Timer and installation panel.
The H3AM-NS@-@-300 model with waterproof packing is available.
±0.7% FS max.
±2% FS max.
Reset input time: 0.5 s max.
±1% FS max.
±2% FS max.
Ω max. (at 500 VDC)
2,000 VAC (50/60 Hz) for 1 min between the operating circuit and control output terminals
1,000 VAC (50/60 Hz) for 1 min between the operating power supply circuit and reset input circuit (H3AM-NSR only)
1,000 VAC (50/60 Hz) for 1 min between contacts not located next to each other
2,000 VAC (50/60 Hz) for 1 min between contacts of opposite poles
4.5 kV between exposed non-current-carrying metal parts and current-carrying metal parts
±1.5 kV (between power terminals) square-wave noise by a noise simulator
(pulse width: 100 ns/1
Destruction: 15 kV
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 2 cycles each in 3 directions (8 min per cycle)
Destruction: 300 m/s
Malfunction: 150 m/s
Electrical: 100,000 times min. (5-A at 250 VAC, resistive load at 1,800 times/h)
Emission Enclosure: EN55011 class A
Emission AC Mains: EN55011 class A
(EMS): EN61812-1
Immunity ESD: IEC61000-4-2: 6 kV contact discharge