Note 1. When ordering, add the rated coil voltage to the model number.
Example: G2RL-1A DC5
However, the notation of the coil voltage on the product case will be marked as @@VDC.
Note 2. Place your order in tube (20 pcs/tube) units.
Note 3. Contact your OMRON sales representative for sealed models.
Rated coil voltage
PCB Power Relay
Low Profile Power Relay
with 15.7 mm height, ideal for
incorporation in miniature
equipments
• A wide variety of single pole, double pole, high-capacity (16 A)
type and high-sensitivity type (250 mW) Relays are available.
• Low profile; 15.7 mm max. in height.
• Conforms to VDE (EN61810-1), UL508 and CSA22.2.
• IEC/EN 60335-1 conformed. (-HA Model)
• Satisfies ambient operating temperature requirement of 85°C
and 105°C (-CV Model).
• Clearance and creepage distance: 8 mm / 8 mm min.
• Coil insulation system: Class F (UL1446).
RoHS Compliant
G
2
R
L
■Ordering Information
Terminal ShapeMarket Code ClassificationContact formEnclosure ratingModelRated coil voltage Minimum packing unit
SPST-NO (1a)
SPDT (1c)
DPST-NO (2a)
DPDT (2c)
SPST-NO (1a)
SPDT (1c)
SPST-NO (1a)
SPDT (1c)G2RL-1-H
DPST-NO (2a)G2RL-2A-HA
DPDT (2c)G2RL-2-HA
SPST-NO (1a)G2RL-1A-E-HA
SPDT (1c)G2RL-1-E-HA
PCB terminals
General
purpose
Home
Appliance
Standard
High-capacity
High-sensitivity
Standard
High-capacity
Flux protectionG2RL-1A
SealedG2RL-1A4
Flux protectionG2RL-1
SealedG2RL-14
Flux protectionG2RL-2A
SealedG2RL-2A4
Flux protectionG2RL-2
SealedG2RL-24
Flux protectionG2RL-1A-E
SealedG2RL-1A4-E
Flux protectionG2RL-1-E
SealedG2RL-14-E
G2RL-1A-E-CV
G2RL-1A-H
Flux protection
5 VDC
12 VDC
24 VDC
48 VDC
12 VDC
24 VDC
20 pcs/tube
1
G2RLPCB Power Relay
■Ratings
●Coil
Item
Rated current
Rated voltage% of rated voltage
5 VDC80.062.5
Standard
Highsensitivity
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
* This value was measured at a switching frequency of 120 operations/min.
Note: Contact your OMRON representative for the ratings on sealed models.
12 A at 250 VAC
12 A at 24 VDC (See note)
Must operate voltage
(V)
70% max.
75% max.Approx. 250
8 A at 250 VAC
8 A at 30 VDC (See note)
8 A (70°C)/5 A (85°C) (See
note)
40 mA at 24 VDC
Must release voltage
(V)
10% min.
High-capacity type (resistive load) High-sensitivity type (resistive load)
G2RL-1A-E (-CV)
16 A at 250 VAC
16 A at 24 VDC (See note)
16 A (See note)10 A (See note)
Max. voltage
(V)
130%
(at 85°C)
G2RL-1-EG2RL-1A-HG2RL-1-H
Power consumption
(mW)
Approx. 40012 VDC33.3360
10 A at 250 VAC (See note)
■Characteristics
ItemNumber of poles1-pole2-pole1-pole
Contact resistance *1100 mΩ max.
Operate (set) time15 ms max.
Release (reset) time5 ms max.
Insulation resistance *21,000 MΩ min.
Dielectric
strength
Impulse withstand voltage10 kV (1.2 x 50 μs)
Vibration
resistance
Shock
resistance
Durability
Ambient operating temperature
Ambient operating humidity5% to 85% (with no icing or condensation)
WeightApprox. 12 g
Note. Values in the above table are the initial values at 23°C.
*1. Measurement conditions: 5 VDC, 1 A, voltage drop method
*2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter.
*3. 1,800 operations per hour.
Classification
Between coil and
contacts
Between contacts
of the same
polarity
Between contacts
of different polarity
Destruction10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Destruction1,000 m/s
MalfunctionEnergized: 100 m/s2, De-energized: 100 m/s
Mechanical20,000,000 operations (at 18,000 operations/hr)
Electrical *3
(resistive load)
G2RL-1(A):
50,000 operations at 250 VAC, 12 A
30,000 operations at 24 VDC, 12 A
−
Standard typeHigh-capacity typeHigh-sensitivity type
5,000 VAC, 50/60 Hz for 1min
1,000 VAC, 50/60 Hz for 1min
2,500 VAC, 50/60 Hz for 1min
2
G2RL-1(A)-E:
G2RL-2(A):
30,000 operations at 250 VAC, 8 A
30,000 operations at 30 VDC, 8 A
-40°C to 85°C (with no icing or condensation)
-40°C to 105°C (with no icing or condensation) by G2RL-1A-E-CV
30,000 operations at 250 VAC, 16 A
30,000 operations at 24 VDC, 16 A
G2RL-1A-E-CV:
50,000 operations at 250 VAC, 16 A
at 105°C
−
2
G2RL-1(A)-H:
50,000 operations at 250 VAC, 10 A
2
G2RLPCB Power Relay
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1
0 5 10 20 30 50 100 500
1,000
AC resistive load
DC resistive
load
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1
0 5 10 20 30 50 100 500
1,000
AC resistive load
DC resistive
load
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1
0 5 10 20 30 50 100 500
1,000
AC resistive load
DC resistive
load
(
)
■Engineering Data
●Maximum Switching Capacity
G2RL-1A, G2RL-1G2RL-1A-E, G2RL-1-EG2RL-2A, G2RL-2
50
AC resistive load
10
Switching current (A)
5
1
0.5
0.1
0 5 10 20 30 50 100 500
DC resistive
load
Switching voltage (V)
1,000
●High-sensitivity type
G2RL-1A-H, G2RL-1-H
●
Ambient Temperature vs. Must
Operate and Must Release Voltages
100
Sample:
G2RL-14-E 24 VDC
90
Number of relays: 5 pcs
80
70
60
50
(percentage of rated voltage) (%)
40
Must operate/must release voltage
30
20
10
060402080100 120
Must operate voltage
Must release voltage
Ambient temperature (°C)
max.
min.
max.
min.
●Ambient Temperature vs. Rated
Carry Current
20
G2RL-1A-E, G2RL-1-E
16
15
G2RL-1A, G2RL-1
12
Rated Carry Current (A)
G2RL-1A-H, G2RL-1-H
10
8
G2RL-2A, G2RL-2
5
0 10 20 30 40 50 60 70 80 90 100
Ambient temperature (°C)
85
●Ambient Temperature vs. Maximum
Coil Voltage
250
%
200
180
150
Maximum coil voltage
130
110
100
50
0 10 20 30 40 50 60 70 80 85 90 100 105 110
G2RL-1A-E-CV
Other type
Ambient temperature (°C)
G
2
R
L
Note. The maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
X
X
3
G2RLPCB Power Relay
G2RL-1 (A)-EG2RL-2 (A)
Sample: G2RL-14 12 VDC
Number of Relays: 5 pcs
Test conditions: Shock is applied
in ±X, ±Y, and ±Z directions three
times each with without energ izing
the Relays to check the number of
malfunctions.
Requirement: None malfuction
100 m/s
2
Sample: G2RL-24 12 VDC
Number of Relays: 5 pcs
Test conditions: Shock is applied
in ±X, ±Y, and ±Z directions three
times each with without energizing
the Relays to check the number of
malfunctions.
Requirement: None malfuction
100 m/s
2
G2RL-1A, G2RL-1A4, G2RL-1A-H
PCB Mounting Holes
(Bottom View)
(No coil polarity)
Terminal Arrangement/
Internal Connections
(Bottom View)
G2RL-1, G2RL-14, G2RL-1-H
PCB Mounting Holes
(Bottom View)
(No coil polarity)
Terminal Arrangement/
Internal Connections
(Bottom View)
G2RL-1A-E (-HA), G2RL-1A4-E, G2RL-1A-E-CV
PCB Mounting Holes
(Bottom View)
(No coil polarity)
Terminal Arrangement/
Internal Connections
(Bottom View)
●Shock Malfunction
1,000
X'
Z'
NO contact
NC contact
130
Y
Y'
1,000
1,000
Unit: m/s
Z
1,0001,000
1,000
X
2
Shock direction
XX'
Y
Y'
Z
Z'
1,000
NO contact
X'
Z'
150
NC contact
Y
Y'
1,000
1,000
Unit: m/s
1,0001,000
1,000
2
■Electrical Endurance Data (Reference Value)
G2RL-1-E
G2RL-1
G
G2RL-2
2
R
G2RL-1A-E
L
Note. The results shown reflect values at ambient temperature 23°C. Electrical endurance will vary depending on the test conditions.
Contact your OMRON representative if you require more detailed information for the electrical endurance under your test condition.
8 A 250 VAC (cosφ=0.4)
8 A 30 VDC (L/R=7 ms)
5 A 250 VAC (cosφ=0.4)
5 A 30 VDC (L/R=7 ms)
8 A 250 VAC (cosφ=1)
8 A 30 VDC
Pilot duty (A300), 250 VAC
Pilot duty (A300), 125 VAC
200,000 operation min. (N.O.)
10,000 operation min. (N.O.)
150,000 operation min. (N.O.)
10,000 operation min. (N.O.)
30,000 operation min.
10,000 operation min.
250,000 operation min.
150,000 operation min.
■Dimensions (Unit: mm)
Z
X
Shock direction
XX'
Y
Y'
Z
Z'
12.7 max.
29 max.
(28.8)*
15.7 max.
(15.5)*
3.5
15.7 max.
(15.5)*
3.5
15.7 max.
(15.5)*
3.5
0.5
29 max.
(28.8)*
0.5
0.5
0.5
29 max.
(28.8)*
0.5
(12.5)*
0.50.50.8
* Average value
12.7 max.
(12.5)*
0.50.8
* Average value
12.7 max.
(12.5)*
0.50.5
* Average value
0.8
4
7.5
(2.3)20
7.5
(2.3)20
7.5
(2.3)20
3.5
Four, 1.3-dia. holes
(2.5)
3.5
3.5
Five, 1.3-dia. holes
(2.5)1243
5
Six, 1.3-dia. holes
(2.5)
1
5
5
13
3
4
6458
G2RLPCB Power Relay
G2RL-1-E (-HA), G2RL-14-E
PCB Mounting Holes
(Bottom View)
(No coil polarity)
Terminal Arrangement/
Internal Connections
(Bottom View)
G2RL-2A (-HA), G2R-2A4
PCB Mounting Holes
(Bottom View)
(No coil polarity)
Terminal Arrangement/
Internal Connections
(Bottom View)
123
64758
(2.5)
15.7 max.
(15.5)*
3.5
0.5
0.5
0.50.8
0.5
29 max.
(28.8)*
12.7 max.
(12.5)*
5
Eight, 1.3-dia. holes
5
7.5
(2.3)20
* Average value
G2RL-2 (-HA), G2R-24
PCB Mounting Holes
(Bottom View)
(No coil polarity)
Terminal Arrangement/
Internal Connections
(Bottom View)
5
5
Eight, 1.3-dia. holes
5
Six, 1.3-dia. holes
(2.5)
(2.5)
123
64758
13
6458
15.7 max.
(15.5)*
3.5
15.7 max.
(15.5)*
3.5
12.7 max.
29 max.
(28.8)*
0.5
0.5
0.5
29 max.
(28.8)*
0.5
(12.5)*
0.50.8
* Average value
12.7 max.
(12.5)*
0.50.5
* Average value
7.5
(2.3)20
7.5
(2.3)20
0.8
G
2
R
L
■Approved Standards
• The approval rating values for overseas standards are different from the performance values determined individually. Confirm
the values before use.
UL Recognized:
CSA Certified:(File No. LR31928)
ModelContact formCoil ratingsContact ratings
G2RL-1ASPST-NO (1a)
G2RL-1SPDT (1c)12 A, 24 VDC (Resistive) 40°C50,000
G2RL-1A-E (-HA)SPST-NO (1a)16 A, 250 VAC (General Use) 40°C100,000
G2RL-1-E (-HA)SPDT (1c)16 A, 24 VDC (Resistive) 40°C50,000
G2RL-1A-E-CVSPST-NO (1a)16 A, 250 VAC (Resistive) 105°C100,000
G2RL-1A-HSPST-NO (1a)10 A, 250 VAC (General Use) 40°C
G2RL-1-HSPDT (1c)10 A, 24 VDC (Resistive) 40°C
G2RL-2A (-HA)DPST-NO (2a)
G2RL-2 (-HA)DPDT (2c)
(File No. 41643)
3 to 48 VDC
Number of test
operations
12 A, 250 VAC (General Use) 40°C100,000
50,000
8 A, 277 VAC (General Use) 40°C
8 A, 30 VDC (Resistive) 40°C
100,000
5
G2RLPCB Power Relay
EN/IEC, VDE Certified (Certificate No. 119650)
ModelContact formCoil ratingsContact ratings
G2RL-1ASPST-NO (1a)
G2RL-1SPDT (1c)
G2RL-1A-E (-HA)SPST-NO (1a)
G2RL-1-E (-HA)SPDT (1c)
G2RL-1A-E-CVSPST-NO (1a)16 A, 250 VAC (cos
G2RL-1A-H
G2RL-1-H
G2RL-2A (-HA)DPST-NO (2a)
G2RL-2 (-HA)DPDT (2c)
Creepage distance8 mm min.
Clearance distance8 mm min.
Insulation material groupIIIa
Type of insulation coil-contact circuit
G
Rated Insulation voltage250 V
2
Pollution degree3 (Flux protection / Sealed)
R
Rated voltage system250 V / 400 V (Flux protection)
L
Over voltage categoryIII
Category of protection according to IEC 61810-1 RT II (Flux protection) / RT III (Sealed)
Glow wire according to IEC 60335-1
Tracking Index of relay basePTI 250 V min. (housing parts)
SPST-NO (1a)
SPDT (1c)
open contact circuit
3 to 48 VDC
12 A, 250 VAC (cos
12 A, 24 VDC (L/R=0 ms) 85°C
AC15: 3 A at 240 VAC at room temperature
DC13: 2.5 A at 24 VDC, 50ms at room temperature
16 A, 250 VAC (cos
16 A, 24 VDC (L/R=0 ms) 85°C15,000
AC15: 3 A at 240 VAC (NO) at room temperature,
1.5 A at 240V AC (NC) at room temperature
DC13: 2.5 A at 24 VDC (NO), 50ms at room temperature
10 A, 250 VAC (cos
10 A, 250 VAC (cos
10 A, 24 VDC (L/R=0 ms) 85°C50,000
8 A, 250 VAC (cos
8 A, 30 VDC (L/R=0 ms) 85°C15,000
AC15: 1.5 A at 240VAC at room temperature
DC13: 2 A at 30 VDC, 50ms at room temperature
Reinforced
Micro disconnection
<HA Models only>
GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12)
φ
=1) 85°C
φ
=1) 85°C30,000
φ
=1) 105°C100,000
φ
=1) 85°C50,000
φ
=1) 40°C100,000
φ
=1) 85°C30,000
Number of test
operations
100,000
6,000
6,000
6,000
■Precautions
• Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
● Mounting Position Compared to G2R Model
• Although the G2RL model and the G2R model are both low
profile Relays, their characteristics such as switching capacity
are different. Be sure to check operation under the actual
operating conditions before use.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
● Cleaning
• The G2RL model is flux-resistant with two sealing holes on the
case. Thus, do not clean the Relay by boiling or soaking in
water. Consult your Omron sales representative for sealed
type Relay.
●
Using Relays in an Atmosphere Containing Corrosive Gas
• Do not use Relays in an atmosphere containing corrosive gas
(sulfuric or organic gas).Otherwise, connection failure due to
corrosion on the contact surface may lead to functional faults.
OMRON Corporation
Electronic and Mechanical Components Company
6
Note: Do not use this document to operate the Unit.
Contact: www.omron.com/ecb
Cat. No. J117-E1-09
0316(0207)(O)
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.