G2RL
G2RL-@@@-@ -@ -@ -@
——— — — — —
1 2 3 4 5 6 7
1. Number of poles
1: 1 pole
2: 2 pole
2. Contact Form
None : SPDT (1c)
A : SPST-NO (1a)
3. Enclosure rating
None : Flux protection
4: Sealed
4. Classification
None : Standard
E : High-capacity
H : High-sensitivity
■Model Number Legend ■Application Examples
• Home appliances
• OA equipments
• Industrial machinery
5. Special Requirement
None : Standard
CV : 16 A, pinning 5 mm,: switching at 105°C
6. Market Code
None : General purpose
HA : Home Appliance according to IEC/EN60335-1
7. Contact material
None : Standard (Ag-alloy, Cd free)
ASI : AgSnIn
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G2RL-1A DC5
However, the notation of the coil voltage on the product case will be marked as @@VDC.
Note 2. Place your order in tube (20 pcs/tube) units.
Note 3. Contact your OMRON sales representative for sealed models.
Rated coil voltage
PCB Power Relay
Low Profile Power Relay
with 15.7 mm height, ideal for
incorporation in miniature
equipments
• A wide variety of single pole, double pole, high-capacity (16 A)
type and high-sensitivity type (250 mW) Relays are available.
• Low profile; 15.7 mm max. in height.
• Conforms to VDE (EN61810-1), UL508 and CSA22.2.
• IEC/EN 60335-1 conformed. (-HA Model)
• Satisfies ambient operating temperature requirement of 85°C
and 105°C (-CV Model).
• Clearance and creepage distance: 8 mm / 8 mm min.
• Coil insulation system: Class F (UL1446).
• G2RL-1A-E-ASI: TV3 Rating models available.
RoHS Compliant
G
2
R
L
■Ordering Information
Terminal Shape Market Code Classification Contact form Enclosure rating Model Rated coil voltage Minimum packing unit
SPST-NO (1a)
Standard
General
purpose
PCB terminals
Home
Appliance
High-capacity
High-sensitivity
Standard
High-capacity
SPDT (1c)
DPST-NO (2a)
DPDT (2c)
SPST-NO (1a)
SPDT (1c)
SPST-NO (1a)
SPDT (1c) G2RL-1-H
DPST-NO (2a) G2RL-2A-HA
DPDT (2c) G2RL-2-HA
SPST-NO (1a) G2RL-1A-E-HA
SPDT (1c) G2RL-1-E-HA
Flux protection G2RL-1A
Sealed G2RL-1A4
Flux protection G2RL-1
Sealed G2RL-14
Flux protection G2RL-2A
Sealed G2RL-2A4
Flux protection G2RL-2
Sealed G2RL-24
Flux protection
Sealed G2RL-1A4-E
Flux protection G2RL-1-E
Sealed G2RL-14-E
Flux protection
G2RL-1A-E
G2RL-1A-E-ASI
G2RL-1A-E-CV
G2RL-1A-H
5 VDC
12 VDC
24 VDC
48 VDC
12 VDC
24 VDC
20 pcs/tube
1

G2RL PCB Power Relay
■Ratings
●Coil
Item
Rated current
Rated voltage % of rated voltage
5 VDC 80.0 62.5
Standard
Highsensitivity
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
24 VDC 16.7 1,440
48 VDC 8.96 5,358 Approx. 430
12 VDC 20.8 576
24 VDC 10.42 2,304
(mA)
Coil resistance
(Ω)
●Contacts
Classification Standard type (resistive load)
Item Model G2RL-1A G2RL-1 G2RL-2A G2RL-2
Contact type Single
Contact material Ag-alloy (Cd free)
Rated load
Rated carry current 12 A (See note)
Max. switching voltage 440 VAC, 300 VDC
G
Max. switching current 12 A 8 A 16 A 10 A
2
R
Failure rate (P level)
L
(reference value*)
* This value was measured at a switching frequency of 120 operations/min.
Note: Contact your OMRON representative for the ratings on sealed models.
12 A at 250 VAC
12 A at 24 VDC (See note)
8 A at 250 VAC
8 A at 30 VDC (See note)
8 A (70°C)/5 A (85°C)
Must operate voltage
70% max.
75% max. Approx. 250
(See note)
(V)
Must release voltage
High-capacity type (resistive load) High-sensitivity type (resistive load)
G2RL-1A-E (-CV, -ASI)
16 A at 250 VAC
16 A at 24 VDC (See note)
40 mA at 24 VDC
(V)
10% min.
16 A (See note) 10 A (See note)
Max. voltage
(V)
130%
(at 85°C)
G2RL-1-E G2RL-1A-H G2RL-1-H
Power consumption
(mW)
Approx. 40012 VDC 33.3 360
10 A at 250 VAC (See note)
■Characteristics
Item Number of poles 1-pole 2-pole 1-pole
Contact resistance *1 100 mΩ max.
Operate (set) time 15 ms max.
Release (reset) time 5 ms max.
Insulation resistance *2 1,000 MΩ min.
Dielectric
strength
Impulse withstand voltage 10 kV (1.2 x 50 μs)
Vibration
resistance
Shock
resistance
Durability
Ambient operating temperature
Ambient operating humidity 5% to 85% (with no icing or condensation)
Weight Approx. 12 g
Note. Values in the above table are the initial values at 23°C.
*1. Measurement conditions: 5 VDC, 1 A, voltage drop method
*2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter.
*3. 1,800 operations per hour.
Classification
Between coil and
contacts
Between contacts
of the same
polarity
Between contacts
of different polarity
Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Destruction 1,000 m/s
Malfunction Energized: 100 m/s2, De-energized: 100 m/s
Mechanical 20,000,000 operations (at 18,000 operations/hr)
Electrical *3
(resistive load)
G2RL-1(A):
50,000 operations at 250 VAC, 12 A
30,000 operations at 24 VDC, 12 A
−
Standard type High-capacity type High-sensitivity type
5,000 VAC, 50/60 Hz for 1min
1,000 VAC, 50/60 Hz for 1min
2,500 VAC, 50/60 Hz for 1min
2
G2RL-1(A)-E, G2RL-1A-E-ASI:
G2RL-2(A):
30,000 operations at 250 VAC, 8 A
30,000 operations at 30 VDC, 8 A
-40°C to 85°C (with no icing or condensation)
-40°C to 105°C (with no icing or condensation) by G2RL-1A-E-CV
30,000 operations at 250 VAC, 16 A
30,000 operations at 24 VDC, 16 A
G2RL-1A-E-CV:
50,000 operations at 250 VAC, 16 A
at 105°C
2
−
G2RL-1(A)-H:
50,000 operations at 250 VAC, 10 A
2