ClassificationEnclosure ratingContact formModelRated coil voltage
12, 24, 100/(110) VAC
NOG2R-1A-T
General-purpose Unsealed
NO/NCG2R-1-T
● Full-wave Rectifier
Number of poles1-pole2-pole
ClassificationEnclosure ratingContact formModelRated coil voltageModelRated coil voltage
NOG2R-1A-Z
Flux protection
NO/NCG2R-1-Z
General-purpose
NOG2R-1A4-Z
Fully sealed
NO/NCG2R-14-Z
High-capacityFlux protection
NOG2R-1A-EZ
NO/NCG2R-1-EZ12, 24, 48 VDC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
5, 12, 24 VDC
100 VDC100 VDC
5, 12, 24, 48 VDC
100 VDC100 VDC
5, 12, 48 VDC
100 VDC100 VDC
5, 12, 24, 48 VDC
100 VDC100 VDC
5, 12, 24 VDC
G2R-2A-Z
G2R-2-Z
G2R-2A4-Z
G2R-24-Z
5, 6, 12, 24, 48 VDC
12, 24, 48 VDC
24, 48 VDC
5, 12, 24 VDC
−100 VDC
G
2
R
● For Ultrasonically Cleanable
Number of poles1-pole2-pole
ClassificationEnclosure ratingContact formModelRated coil voltageModelRated coil voltage
NOG2R-1A4-U
General-purpose Fully sealed
NO/NCG2R-14-U
Note: When ordering, add the rated coil voltage to the model number.
Example: G2R-1A-T 12 VAC
12, 24, 100/(110) VAC
200/(220) VAC−
5, 6, 12, 24, 48 VDC5, 12, 24 VDC
100/(110) VAC
200/(220) VAC
5, 12, 24, 48 VDC5, 12, 24, 48 VDC
100 VDC100 VDC
G2R-2A4-U
G2R-24-U
100/(110) VAC
24, 100/(110) VAC
200/(220) VAC
3
Page 4
G2RPCB Power Relay
G
2
R
■Ratings
● Coil
Item Rated current (mA)
Classification
• General-purpose
• Quick-connect
• Fully sealed
• High-capacity
• General-purpose
• High-capacity
• Bifurcated contact
• Quick-connect
• Fully sealed
• High-sensitivity
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of+15%/-20% (AC rated current) or ±10% (DC coil resistance).
2.AC coil resistances shown above are only reference values.
3.The operating characteristics are measured at a coil temperature of 23°C.
4.The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Rated voltage50 Hz60 Hz% of rated voltage
12 VAC937565
24 VAC46.537.5260
100/(110) VAC119/(10.6)4,600
200/(220) VAC5.54.5/(5.3)20,200
5 VDC10647
6 VDC88.268
12 VDC43.6275
24 VDC21.81,100
48 VDC11.54,170
100 VDC5.318,860
5 VDC71.470
6 VDC60100
12 VDC30400
24 VDC151,600
48 VDC7.56,400
Coil resistance
(Ω)
Must operate
voltage (V)
80% max.30% min.
70% max.15% min.
70% max.15% min.
Must release
voltage (V)
Max. voltage
(V)
140%
(at 23°C)
170%
(at 23°C)
170%
(at 23°C)
Powe r
consumption
(VA, W)
Approx. 0.9
(60 Hz)
Approx. 0.53
Approx. 0.36
● Coil: Double-winding Latching Relays
ItemSet CoilReset coil
Rated current
Rated voltage
5 VDC1673011942
6 VDC13843.510060
12 VDC70.617050240
24 VDC34.669425960
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2.The operating characteristics are measured at a coil temperature of 23°C.
3.The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
(mA)
Coil resistance
(Ω)
Rated current
(mA)
Coil resistance
(Ω)
Must set
voltage (V)
70% max.70% max.
Must reset
voltage (V)
% of rated voltage
Max. voltage
(V)
140%
(at 23°C)
Power consumption
Set Coil
(mW)
Approx.
850
Reset coil
(mW)
Approx.
600
4
Page 5
G2RPCB Power Relay
● Contacts
Classification
Number of poles1-pole2-pole1-pole2-pole1-pole2-pole
* This value was measured at a switching frequency of 120 operations/min.
Load
Resistive load
(cos
φ
= 1)
5 A at 250 VAC
5 A at 30 VDC
100 mA at 5 VDC10 mA at 5 VDC
Inductive load
(cos
φ
= 0.4; L/R = 7 ms)
3.5 A at 250 VAC
2.5 A at 30 VDC
Resistive load
(cos
φ
= 1)
3 A at 250 VAC
3 A at 30 VDC
(cos
1.5 A at 250 VAC
2 A at 30 VDC
Inductive load
φ
= 0.4; L/R = 7 ms)
5
Page 6
G2RPCB Power Relay
G
2
R
Flux Protection/Plug-in Relays
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1
0 5 10 20 30 50 100 500
AC resistive load
DC resistive load
AC
inductive load
(cosφ = 0.4)
DC inductive load
(L/R = 7 ms)
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1
0 5 10 20 30 50 100 500
AC
inductive load
(cosφ = 0.4)
DC inductive load
(L/R = 7 ms)
DC resistive load
AC resistive load
■Characteristics
● Standard Relays
ItemNumber of poles1-pole2-pole
Contact resistance *130 mΩ max.50 mΩ max.
Operate time *215 ms max.
Release time *2AC: 10 ms max.; DC: 5 ms max.
Max.
operating
frequency
Mechanical18,000 operations/hr
Electrical1,800 operations/hr
Insulation resistance *31,000 MΩ min.
Dielectric
strength
Insulation
distance
Vibration
resistance
Shock
resistance
Durability
Between coil and
contacts
Between contacts
of different polarity
Between contacts
of the same
polarity
Between coil and
contacts
Destruction
Malfunction
Destruction1,000 m/s
Malfunction
Mechanical
Electrical
5,000 VAC, 50/60 Hz for 1 min
-
3,000 VAC, 50/60 Hz
for 1 min
1,000 VAC, 50/60 Hz for 1 min
Clearance: 8 mm, Creepage: 8 mm
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
200 m/s
2
when no energized
100m/s
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min.
(at 18,000 operations/hr)
100,000 operations min.
(at 1,800 operations/hr under rated load)
2
2
when energized;
Ambient operating temperature-40°C to 70°C (with no icing)
Ambient operating humidity5% to 85%
WeightApprox. 17 g (Approx. 20 g *4)
Note: The values here are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage-drop method.
*2. Measurement conditions: Rated operating voltage applied, not including
contact bounce.
*3. Measurement conditions: The insulation resistance was measured with a
500 VDC megohmmeter at the same locations as the dielectric strength
was measured.
*4. Value for quick-connect terminals.
■Engineering Data
Double-winding Latching Relays
ItemNumber of poles1-pole2-pole
Contact resistance *130 mΩ max.50 mΩ max.
Set
Reset
Max. operating
frequency
Insulation resistance *41,000 MΩ min.
Dielectric
strength
Insulation
distance
Vibration
resistance
Shock
resistance
Durability
Ambient operating temperature
Ambient operating humidity5% to 85%
WeightApprox. 17 g
Note: The values here are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage-drop method.
*2. Measurement conditions: Rated operating voltage applied, not including
contact bounce.
*3. Measurement couditions: Rated operating voltage applied.
*4. Measurement conditions: The insulation resistance was measured with a
500 VDC megohmmeter at the same locations as the dielectric strength
was measured.
Time *220 ms max.
Min. set pulse width
Time *220 ms max.
Min. reset pulse
width *3
Mechanical18,000 operations/hr
Electrical1,800 operations/hr
Between coil and
contacts
Between contacts of
different polarity
Between contacts of
the same polarity
Between set and
reset coils
Between coil and
contacts
Test Conditions:
Shock is applied in
±X, ±Y, and ±Z
directions three times
each with and without
energizing the Relays
to check the number
of contact
malfunctions.
Requirement:
200 m/s
2
when
energized; 100m/s
2
when de-energized
Z
Z'
Shock direction
Unit: m/s
2
Y
Y
Y'
Y'
X
X
X'
X'
SPST-NO (1a)
SPST-NC (1c)
1,000
1,000
800
600
400
200
200
400
600
800
Z
Z'
270
Test Conditions:
Shock is applied in
±X, ±Y, and ±Z
directions three times
each with and without
energizing the
Relays to check the
number of contact
malfunctions.
Requirement:
200 m/s
2
when
energized; 100m/s
2
when de-energized
Decrement of keep-power (%)
Elapsed time (H)
Number of Relays: 50 pcs
Measurement: after the relay kept static by
applying a rated voltage, leave the relay at room
temperature of 20°C to 30°C, and high temperature
of 80°C ± 2°C respectively, to measure how the
keep-power varies with time.
50 100 500
1,000 5,000 10,000
160
140
120
100
80
60
40
20
0
MAX
MIN
)
MAX
MIN
)
Room
temperature
High
temperature
G2RK-1A, G2RK-1G2RK-2A, G2RK-2
1,000
500
300
operations)
4
100
50
Durability (x10
30
10
5
3
250 VAC/30 VDC
resistive load
30 VDC inductive load
(L/R = 7ms)
250 VAC inductive load
(cosφ = 0.4)
0
1 1.5 2 2.5 3 4
Switching current (A)
G2R-14, G2R-1A4G2R-24, G2R-2A4G2R-1Z4, G2R-1AZ4
1,000
500
300
operations)
● Ambient Temperature vs. Maximum
Coil Voltage
● Ambient Temperature vs. Must
Operate and Must Release Voltage
4
100
50
Durability (x10
30
10
5
3
0
30 VDC inductive load (L/R = 7ms)
250 VAC inductive load
(cosφ = 0.4)
1 2 3 4 5 6
G2R-1G2R-2
250
200
170
150
140
Maximum coil voltage (%)
110
100
AC coil
50
DC coil
100
Sample: G2R-1
Number of Relays: 5 pcs
80
60
40
20
Must operate voltage
Must release voltage
max.
X
min.
max.
X
min.
100
Sample: G2R-2
Number of Relays: 5 pcs
80
60
40
20
250 VAC/30 VDC
resistive load
Switching current (A)
Must operate voltage
Must release voltage
max.
X
min.
max.
X
min.
0
−25 20 30 40 50 60 70 80 90 100
Note: The maximum coil voltage refers to the maximum
value in a varying range of operating power voltage,
not a continuous voltage.
● Shock Malfunction
G2R-1
8
Number of Relays: 5 pcsG2R-2 Number of Relays: 5 pcs
Ambient temperature (°C)
0
Must-operate/must-release voltage (On the basis of rated voltage) (%)
−60 −40 −20 0 20 40 60 80
Ambient temperature (°C)
0
Must-operate/must-release voltage (On the basis of rated voltage) (%)
−60 −40 −20 0 20 40 60 80
Ambient temperature (°C)
● Keep-power decrement with time
G2RK-1
Page 9
G2RPCB Power Relay
** Average value
** With AC coil or “-H” models: 0.3.
1 2 3
5 4
3.5 3.5
(2.7)
20 (2.1)
1 0.5** 0.5
0.16
0.3
4
(0.3)
25.5 max.
(25.3)*
29 max.
(28.8)*
13 max.
(12.7)*
7.5
Five, 1.3-dia.
holes
(No coil polarity)
Relays with PCB Terminals
(SPDT (1c) Relays)
G2R-1(-Z)
G2R-1Z
G2R-1-H
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
This illustration is the
G2R-1 model.
** Average value
** With AC coil or “-H” models: 0.3.
1 3
5 4
3.5
(2.7)
20 (2.1)
1 0.5** 0.3
0.16
4
(0.3)
25.5 max.
(25.3)*
29 max.
(28.8)*
13 max.
(12.7)*
7.5
Four, 1.3-dia.
holes
(No coil polarity)
Relays with PCB Terminals
(SPST-NO (1a) Relays)
G2R-1A(-Z)
G2R-1AZ
G2R-1A-H
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
This illustration is the
G2R-1A model.
123
76
4
85
* Average value
0.310.5
0.16
0.3
4
(0.3)
25.5 max.
(24.9)*
29 max.
(28.6)*
13 max.
(12.6)*
2.5
2.5
(2.1)
20
(2.1)55
(2.7)
7.5
Eight, 1.3-dia. holes
(No coil polarity)
Relays with PCB Terminals
(SPDT (1c) /High-capacity Relays)
G2R-1-E(Z)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
1364
85
* Average value
0.3
0.16
0.3
4
(0.3)
25.5 max.
(24.9)*
29 max.
(28.6)*
13 max.
(12.6)*
2.5
2.5
(2.1)
20
(2.1)5
(2.7)
7.5
Six, 1.3-dia. holes
1
(No coil polarity)
Relays with PCB Terminals
(SPST-NO (1a)/High-capacity Relays)
G2R-1A-E(Z)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Note: Orientation marks are indicated as follows:
■Dimensions
G
2
R
9
Page 10
G2RPCB Power Relay
G
2
R
* Average value
12 3
54
3.5 3.5
(2.7)
20(2.1)
10.50.5
0.16
0.3
4
25.5 max.
(24.8)*
29 max.
(28.6)*
13.5 max.
(12.9)*
7.5
Five, 1.3-dia.
holes
(No coil polarity)
Relays with PCB Terminals
(SPDT (1c) Relays)
G2R-14(-Z)(-U)
G2R-1Z4
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
* Average value
10.5
0.16
0.3
4
25.5 max.
(24.8)*
29 max.
(28.6)*
13.5 max.
(12.9)*
13
54
3.5
(2.7)
20(2.1)
7.5
Four, 1.3-dia.
holes
(No coil polarity)
Relays with PCB Terminals
(SPST-NO (1a) Relays)
G2R-1A4(-Z)(-U)
G2R-1AZ4
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
* Average value
1
-
+
S
3 4
7
2
-
+
R
6 5
3.5 3.5
(2.7)
20
5
(2.1)
1
0.3
1
4
(0.3)
25.5 max.
(25.2)*
29 max.
(28.8)*
13 max.
(12.8)*
7.5
Seven, 1.3-dia.
holes
(After confirming coil
polarity, wire correctly.)
0.5
0.5
10.16
Double-winding Latching Relays with
PCB Terminals
(SPDT (1c) Relays)
G2RK-1
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
1
1
−
+
S
4
7
2
−
+
R
65
3.5
(2.7)
20
5
(2.1)
7.5
Six, 1.3-dia.
holes
* Average value
0.50.3
0.161
4
(0.3)
25.5 max.
(25.2)*
29 max.
(28.8)*
13 max.
(12.8)*
(After confirming coil
polarity, wire correctly.)
Double-winding Latching Relays with
PCB Terminals
(SPST-NO (1a) Relays)
G2RK-1A
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
* Average value
1 0.5
0.50.3
1 0.15
4
(0.3)
25.5 max.
(25.3)*
29 max.
(28.8)*
13 max.
(12.8)*
1
-
+
S
10
2
-
+
R
9
3 4
8 7
5
6
2.5
2.5
(2.1)
20
(2.1) 5 5 5
(2.7)
(2.7)
7.5
Ten, 1.3-dia. holes
(After confirming coil
polarity, wire correctly.)
Double-winding Latching Relays with PCB Terminals
(DPDT (2c) Relays)
G2RK-2
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
* Average value
1 0.5
0.3
1 0.15
4
(0.3)
25.5 max.
(25.3)*
29 max.
(28.8)*
13 max.
(12.8)*
2.5
2.5
(2.1)
20
(2.1) 5 5
(2.7)
(2.7)
7.5
Eight, 1.3-dia. holes
1
-
+
S
10
2
-
+
R
9
4 7 5
6
(After confirming coil
polarity, wire correctly.)
Double-winding Latching Relays with PCB Terminals
(DPST-NO (2a) Relays)
G2RK-2A
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
10
Note: Orientation marks are indicated as follows:
Page 11
G2RPCB Power Relay
10.50.5
0.15
0.3
4
(0.3)
25.5 max.
(25.2)*
29 max.
(28.8)*
13 max.
(12.7)*
* Average value
1
8
23
76
4
5
2.5
2.5
(2.1)
20
(2.1)55
(2.7)
7.5
Eight, 1.3-dia. holes
(No coil polarity)
Relays with PCB Terminals
(DPDT (2c) Relays)
G2R-2(-Z)
G2R-2-H
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
10.5
0.3
0.15
4
(0.3)
25.5 max.
(25.2)*
29 max.
(28.8)*
13 max.
(12.7)*
* Average value
1
8
3
6
4
5
2.5
2.5
(2.1)
20
(2.1)5
(2.7)
7.5
Six, 1.3-dia. holes
(No coil polarity)
Relays with PCB Terminals
(DPST-NO (2a) Relays)
G2R-2A
G2R-2A-H
G2R-2A-Z
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
* Average value
10.50.5
0.15
0.3
4
25.5 max.
(24.7)*
29 max.
(28.6)*
13.5 max.
(12.8)*
1
8
23
76
4
5
2.5
2.5
(2.1)
20
(2.1)55
(2.7)
7.5
Eight, 1.3-dia. holes
(No coil polarity)
Relays with PCB Terminals
(DPDT (2c) Relays)
G2R-24(-Z)(-U)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
* Average value
10.5
0.15
0.3
4
25.5 max.
29 max.
(28.6)*
13.5 max.
(12.8)*
1
8
3
6
4
5
2.5
2.5
(2.1)
20
(2.1)5
(2.7)
7.5
Six, 1.3-dia. holes
(No coil polarity)
Relays with PCB Terminals
(DPST-NO (2a) Relays)
G2R-2A4(-Z)(-U)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Note: Orientation marks are indicated as follows:
G
2
R
11
Page 12
G2RPCB Power Relay
G
2
R
38
Two M3 or
two 3.5 dia.
30.5 max.
(29.7)*
45 max.
(43.9)*
14 max.
(13.1)*
7.5
5.25.2
17.5
4.75
Five, 1.3-dia. holes
0.5
8.5
29.5 max.
2.5
1
5
24
3
* Average value
(No coil polarity)
Note: Model number of
quick-connect terminal is 187.
Relays with Quick-connect
Terminals
(SPDT (1c) Relays)
G2R-1-T
Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Relays with Quick-connect
Terminals
(SPST-NO (1a) Relays)
G2R-1A-T
Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
30.5 max.
(29.7)*
7.5
Four, 1.3-dia. holes
2.5
17.4
4.75
45 max.
(43.9)*
5.2
0.5
29.5 max.
* Average value
8.5
14 max.
(13.1)*
38
Note: Model number of
quick-connect terminal is 187.
Two M3 or
two 3.5 dia.
1
4
5
(No coil polarity)
Note: Orientation marks are indicated as follows:
3
12
Page 13
G2RPCB Power Relay
■Approved Standards
• The approval rating values for overseas standards are different from the performance values determined individually. Confirm the
values before use.
UL Recognized:
1-pole
Model
G2R-1A
G2R-1A4
G2R-1A-H
G2R-1A-T
G2R-1
G2R-14
G2R-1-H
G2R-1-T
G2R-1AZ
G2R-1AZ4
G2R-1Z
G2R-1Z4
G2R-1A-E
G2R-1-E
Contact
form
SPST-NO
(1a)
SPDT
(1c)
SPST-NO
(1a)
SPDT
(1c)
SPST-NO
(1a)
SPDT
(1c)
2-pole
Model
G2R-2A
G2R-2A4
G2R-2A-H
G2R-2
G2R-24
G2R-24-H
Contact
form
DPST-NO
(2a)
DPDT
(2c)
File No. E41643
Coil ratingsContact ratings
10 A, 250 VAC (General
Use) at 40°C
5 A, 277 VAC (General
5 to 110 VDC
12 to 220 VAC
5 to 110 VDC
12 to 220 VAC
5 to 110 VDC
12 to 220 VAC
Coil ratingsContact ratings
5 to 110 VDC
12 to 220 VAC
Use) at 40°C
5 A, 30 VDC (Resistive)
at 40°C
TV-3 (N. O. only) at
40°C
10 A, 250 VAC (General
Use) at 40°C
5 A, 30 VDC (Resistive)
at 40°C
16 A, 250 VAC (General
Use) at 40°C
16 A, 30 VDC
(Resistive) at 40°C
TV-3 (N. O. only) at
40°C
5 A, 250 VAC (General
Use) at 40°C
5 A, 30 VDC (Resistive)
at 40°C
TV-3 (N. O. only) at
40°C
Number of
test
operations
100,000
6,000
100,000
25,000
6,000
30,000
6,000
25,000
Number of
test
operations
6,000
100,000
25,000
CSA Certified:
File No. LR31928
1-pole
Model
G2R-1A
G2R-1A-H
G2R-1A-T
G2R-14
G2R-1-H
G2R-1-T
G2R-1AZ
G2R-1AZ4
G2R-1Z
G2R-1Z4
G2R-1A-E
G2R-1-E
Contact
form
SPST-NO
(1a)
SPDT
(1c)
SPST-NO
(1a)
SPDT
(1c)
SPST-NO
(1a)
SPDT
(1c)
5 to 110 VDC
12 to 220 VAC
5 to 110 VDC
12 to 220 VAC
5 to 110 VDC
12 to 220 VAC
2-pole
Model
G2R-2A
G2R-2A4
G2R-2A-H
G2R-2
G2R-24
G2R-24-H
Contact
form
DPST-NO
(2a)
5 to 110 VDC
12 to 220 VAC
DPDT
(2c)
EN/IEC, VDE Certified:
Model
G2R-1(A)-E1
G2R-( )
Contact
form
5, 6, 12, 24,
48, 100 VDC
200/220 VAC
5, 6, 12, 24,
48, 100 VDC
1
200/220 VAC
5, 6, 12, 24,
48, 100 VDC
2
200/220 VAC
Coil ratingsContact ratings
10 A, 250 VAC (General
Use) at 40°C
10 A, 30 VDC
(Resistive) at 40°C
TV-3 (N. O. only) at
40°C
5 A, 250 VAC (General
Use) at 40°C
5 A, 30 VDC (Resistive)
at 40°C
16 A, 250 VAC (General
Use) at 40°C
16 A, 30 VDC
(Resistive) at 40°C
TV-3 (N. O. only) at
40°C
Coil ratingsContact ratings
5 A, 250 VAC (General
Use) at 40°C
5 A, 30 VDC (Resistive)
at 40°C
TV-3 (N. O. only) at
40°C
Registration No. 40015012
Coil ratingsContact ratings
12, 24,
100/110,
12, 24,
100/110,
12, 24,
100/110,
16 A, 250 VAC
(cos
φ
= 1.0) at 70°C
10 A, 250 VAC
(cos
φ
= 1.0) at 40°C
10 A, 30 VDC (0 ms) at
40°C
5 A, 250 VAC
(cos
φ
= 1.0) at 40°C
5 A, 30 VDC (0 ms) at
40°C
Number of
test
operations
100,000G2R-1A4
100,000 G2R-1
25,000
6,000
6,000
25,000
Number of
test
operations
6,000
100,000
25,000
Number of
test
operations
100,000
G
2
R
EN, TÜV Certified:
Model
G2R-1(A)-E1
G2R-( )
Contact
form
1
2
Registration No. R50030327
Coil ratingsContact ratings
5 to 110 VDC
12 to 220 VAC
5 to 110 VDC
12 to 220 VAC
5 to 110 VDC
12 to 220 VAC
16 A, 250 VAC
(cos
φ
= 1.0) at 70°C
10 A, 250 VAC
(cos
φ
= 1.0) at 70°C
10 A, 30 VDC (0 ms) at
70°C
5 A, 250 VAC
(cos
φ
= 1.0) at 40°C
5 A, 30 VDC (0 ms) at
40°C
Number of
test
operations
100,000
13
Page 14
G2RPCB Power Relay
G
2
R
● Mounting
• When mounting a number of relays on
a PCB, be sure to provide a minimum
mounting space of 5 mm between the
two juxtaposed relays as shown
below.
● Handling
• The terminals are compatible with
Faston receptacle #187 and are
suitable for positive-lock mounting.
Use only Faston terminals with the
specified numbers.
Select leads for connecting Faston
receptacles with wire diameters that
are within the allowable range for the
load current.
Do not apply excessive force to the
terminals when mounting or
dismounting the Faston receptacle.
Also, do not insert terminals at an
angle, or insert/remove multiple
terminals at the same time. Be sure to
insert and remove terminals carefully
one at a time.
Refer to the following table for
examples of positive-lock connectors
made by AMP. Contact the
manufacturer directly for details on
connectors including availability.
Note: The numbers shown in parentheses are for
air-feeding.
● Minimum Pulse Width of Double-
winding Latching Relays
• The minimum pulse width shown in
the table of characteristics are values
measured under conditions of ambient
temperature at 23°C with rated
operating voltage imposed on coil. The
Relay may not provide a satisfactory
performance as its holding ability
decreases depending on the operating
circuit conditions and ambient
temperature, or decreases due to
degradation over time.
In actual operation, impose to the coil
a rated operating voltage with a pulse
width that is suitable to the actual load,
and reset the setting at least once a
year, to correspond to the degradation
over time.
• When using the Relay in a strong
magnetic field environment, the
magnetic body may be demagnetized
due to the influence of environment,
causing the Relay to malfunction.
Therefore, do not use the Relay in a
strong magnetic field environment.
● Degradation over Time of Doublewinding Latching Relays Holding
Ability
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K013-E1-16
1014(0207)(O)
Note: Do not use this document to operate the Unit.
■Precautions
● Please refer to “PCB Relays Common Precautions” for correct use.
14