G2R
G2R-@- @@@@-@@
———————
1234567
1. Relay Function
None: Single-side stable
K : Double-winding latching
2. Number of poles
1: 1-pole
2: 2-pole
3. Contact Form
None: NO/NC
A: NO
4. Contact Type
None: Single
Z : Bifurcated contact
5. Enclosure rating
None: Flux protection
(T-type is an enclosed
relay)
4 : Fully sealed
6. Terminal Shape
None: PCB terminals
T : Quick-connect
(upper bracket mounting
#187)
7. Classification
None: Standard
E : High-capacity
H : High-sensitivity
U : For ultrasonically
cleanable
Z : Full-wave rectifier
PCB Power Relay
The Best Seller G2R
• 1General purpose power Relays of single-pole10 A and double-pole 5 A.
and contacts, and surge resistance of 10,000 V.
• AC and DC types are both available for operational coils.
RoHS Compliant
Model Number Legend
G
2
R
Model Configuration
Terminal Shape
PCB terminals
Quick-connect Standard Unsealed
Note 1. Full-wave rectifier and supersonic cleaner compatible models are also available. Refer to page 3.
2.Sockets for PCB terminal models are not provided.
Number of poles 1-pole 2-pole
Classification
Standard
Bifurcated contact
High-capacity Flux protection
High-sensitivity Flux protection DC G2R-1A-H G2R-1-H G2R-2A-H G2R-2-H
Double-winding latching
Enclosure rating
Flux protection
Fully sealed
Flux protection
Fully sealed G2R-1AZ4 G2R-1Z4 −−
Flux protection DC G2RK-1A G2RK-1 G2RK-2A G2RK-2
Contact
form
AC
DC
AC
DC
DC
AC
DC
AC
DC
SPST-NO (1a) SPDT (1c) DPST-NO (2a) DPDT (2c)
G2R-1A G2R-1 G2R-2A G2R-2
G2R-1A4 G2R-14 G2R-2A4 G2R-24
G2R-1AZ G2R-1Z −−
G2R-1A-E G2R-1-E −−
G2R-1A-T G2R-1-T −−
Minimum packing unit
100
pcs/tray
50
pcs/tray
100
pcs/tray
50
pcs/tray
100
pcs/tray
1
Page 2
G2R PCB Power Relay
G
2
R
Rated coil voltage
Ordering Information
PCB Terminal Models
Number of poles 1-pole 2-pole
Classification Enclosure rating Contact form Model Rated coil voltage Model Rated coil voltage
NO G2R-1A
Flux protection
NO/NC G2R-1
General-purpose
NO G2R-1A4
Fully sealed
NO/NC G2R-14
High-sensitivity
Flux protection Double-winding latching
Flux protection
Bifurcated contact
Fully sealed
High-capacity Flux protection
Note: When ordering, add the rated coil voltage to the model number.
Example: G2R-1A 12 VAC
NO G2R-1A-H 5, 6, 12, 24, 48 VDC G2R-2A-H 5, 6, 12, 24, 48 VDC NO/NC G2R-1-H 5, 6, 12, 24, 48 VDC G2R-2-H 5, 6, 12, 24, 48 VDC NO G2RK-1A 5, 6, 12, 24 VDC G2RK-2A 5, 12, 24 VDC NO/NC G2RK-1 5, 6, 12, 24 VDC G2RK-2 5, 6, 12, 24 VDC
NO G2R-1AZ
NO/NC G2R-1Z
NO G2R-1AZ4
NO/NC G2R-1Z4
NO G2R-1A-E
NO/NC G2R-1-E
12, 24, 100/(110) VAC
200/(220) VAC 200/(220) VAC
5, 6, 12, 24, 48 VDC 5, 6, 12, 24, 48 VDC
100 VDC 100 VDC
12, 24, 100/(110) VAC
200/(220) VAC 200/(220) VAC
5, 6, 12, 24, 48 VDC 5, 6, 12, 24, 48 VDC
100 VDC 100 VDC
12, 24, 100/(110) VAC
200/(220) VAC 200/(220) VAC
5, 6, 12, 24, 48 VDC 5, 6, 12, 24, 48 VDC
100 VDC 100 VDC
12, 24, 100/(110) VAC
200/(220) VAC 200/(220) VAC
5, 6, 12, 24, 48 VDC 5, 6, 12, 24, 48 VDC
100 VDC 100 VDC
12, 24, 48 VDC
100 VDC
5, 6, 12, 24, 48 VDC
100 VDC
5, 12, 24, 48 VDC
100 VDC
5, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
G2R-2A
G2R-2
G2R-2A4
G2R-24
12, 24, 100/(110) VAC
12, 24, 100/(110) VAC
12, 24, 100/(110) VAC
12, 24, 100/(110) VAC
2
Page 3
G2R PCB Power Relay
Rated coil voltage
Quick-connect Terminal (#187)
Number of poles 1-pole
Classification Enclosure rating Contact form Model Rated coil voltage
12, 24, 100/(110) VAC
NO G2R-1A-T
General-purpose Unsealed
NO/NC G2R-1-T
Full-wave Rectifier
Number of poles 1-pole 2-pole
Classification Enclosure rating Contact form Model Rated coil voltage Model Rated coil voltage
NO G2R-1A-Z
Flux protection
NO/NC G2R-1-Z
General-purpose
NO G2R-1A4-Z
Fully sealed
NO/NC G2R-14-Z
High-capacity Flux protection
NO G2R-1A-EZ
NO/NC G2R-1-EZ 12, 24, 48 VDC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
5, 12, 24 VDC
100 VDC 100 VDC
5, 12, 24, 48 VDC
100 VDC 100 VDC
5, 12, 48 VDC
100 VDC 100 VDC
5, 12, 24, 48 VDC
100 VDC 100 VDC
5, 12, 24 VDC
G2R-2A-Z
G2R-2-Z
G2R-2A4-Z
G2R-24-Z
5, 6, 12, 24, 48 VDC
12, 24, 48 VDC
24, 48 VDC
5, 12, 24 VDC
100 VDC
G
2
R
For Ultrasonically Cleanable
Number of poles 1-pole 2-pole
Classification Enclosure rating Contact form Model Rated coil voltage Model Rated coil voltage
NO G2R-1A4-U
General-purpose Fully sealed
NO/NC G2R-14-U
Note: When ordering, add the rated coil voltage to the model number.
Example: G2R-1A-T 12 VAC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC 5, 12, 24 VDC
100/(110) VAC 200/(220) VAC
5, 12, 24, 48 VDC 5, 12, 24, 48 VDC
100 VDC 100 VDC
G2R-2A4-U
G2R-24-U
100/(110) VAC
24, 100/(110) VAC 200/(220) VAC
3
Page 4
G2R PCB Power Relay
G
2
R
Ratings
Coil
Item Rated current (mA)
Classification
• General-purpose
• Quick-connect
• Fully sealed
• High-capacity
• General-purpose
• High-capacity
• Bifurcated contact
• Quick-connect
• Fully sealed
• High-sensitivity
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of+15%/-20% (AC rated current) or ±10% (DC coil resistance).
2.AC coil resistances shown above are only reference values.
3.The operating characteristics are measured at a coil temperature of 23°C.
4.The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Rated voltage 50 Hz 60 Hz % of rated voltage
12 VAC 93 75 65
24 VAC 46.5 37.5 260
100/(110) VAC 11 9/(10.6) 4,600
200/(220) VAC 5.5 4.5/(5.3) 20,200
5 VDC 106 47
6 VDC 88.2 68
12 VDC 43.6 275
24 VDC 21.8 1,100
48 VDC 11.5 4,170
100 VDC 5.3 18,860
5 VDC 71.4 70
6 VDC 60 100
12 VDC 30 400
24 VDC 15 1,600
48 VDC 7.5 6,400
Coil resistance
(Ω)
Must operate
voltage (V)
80% max. 30% min.
70% max. 15% min.
70% max. 15% min.
Must release
voltage (V)
Max. voltage
(V)
140%
(at 23°C)
170%
(at 23°C)
170%
(at 23°C)
Powe r
consumption
(VA, W)
Approx. 0.9
(60 Hz)
Approx. 0.53
Approx. 0.36
Coil: Double-winding Latching Relays
Item Set Coil Reset coil
Rated current
Rated voltage
5 VDC 167 30 119 42
6 VDC 138 43.5 100 60
12 VDC 70.6 170 50 240
24 VDC 34.6 694 25 960
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2.The operating characteristics are measured at a coil temperature of 23°C.
3.The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
(mA)
Coil resistance
(Ω)
Rated current
(mA)
Coil resistance
(Ω)
Must set
voltage (V)
70% max. 70% max.
Must reset voltage (V)
% of rated voltage
Max. voltage
(V)
140%
(at 23°C)
Power consumption
Set Coil
(mW)
Approx.
850
Reset coil
(mW)
Approx.
600
4
Page 5
G2R PCB Power Relay
Contacts
Classification
Number of poles 1-pole 2-pole 1-pole 2-pole 1-pole 2-pole
Item
Contact type Single Single Bifurcated Single
Contact material Ag-alloy (Cd free)
Rated load
Rated carry current 10 A 5 A 16 A 5 A 5 A 3 A
Max. switching voltage 380 VAC, 125 VDC 380 VAC, 125 VDC 380 VAC, 125 VDC
Max. switching current 10 A 5 A 16 A 5 A 5 A 3 A
Failure rate (P level) (reference value) *
* This value was measured at a switching frequency of 120 operations/min.
Contacts: Fully Sealed Models
Classification General-purpose (Single contact) Bifurcated contact
Number of poles 1-pole 2-pole 1-pole
Item
Contact type Single Single Bifurcated
Contact material Ag-alloy (Cd free)
Rated load
Rated carry current 8 A 4 A 5 A
Max. switching voltage 380 VAC, 125 VDC 380 VAC, 125 VDC 380 VAC, 125 VDC
Max. switching current 8 A 4 A 5 A
Failure rate (P level) (reference value) *
* This value was measured at a switching frequency of 120 operations/min.
General-purpose Quick-connect Terminal (1single-pole type)
Inductive
Resistive
Load
load
10 A at 250 VAC 10 A at 30 VDC
100 mA at 5 VDC 10 mA at 5 VDC 100 mA at 5 VDC 1 mA at 5 VDC 100 mA at 5 VDC 10 mA at 5 VDC
Load
Resistive load
8 A at 250 VAC 8 A at 30 VDC
load
Resistive
φ
= 0.4;
5 A at 250 VAC 5 A at 30 VDC
(cos
100 mA at 5 VDC 10 mA at 5 VDC 1 mA at 5 VDC
(cos
(cos L/R = 7 ms)
7.5 A at 250 VAC 5 A at 30 VDC
φ
= 1)
Inductive
load
(cos
load
Inductive load
φ
= 0.4; L/R = 7 ms)
6 A at 250 VAC 4 A at 30 VDC
φ
L/R = 7 ms)
2 A at 250 VAC 3 A at 30 VDC
= 0.4;
High-capacity Bifurcated contact High-sensitivity
Resistive
load
16 A at 250 VAC 16 A at 30 VDC
Resistive load
(cos
4 A at 250 VAC 4 A at 30 VDC
Inductive
load
(cos
φ
= 0.4;
L/R = 7 ms)
8 A at 250 VAC 8 A at 30 VDC
φ
= 1)
Resistive
5 A at 250 VAC 5 A at 30 VDC
(cos
Inductive
load
(cos
load
Inductive load
φ
= 0.4; L/R = 7 ms)
1.5 A at 250 VAC
2.5 A at 30 VDC
φ
L/R = 7 ms)
2 A at 250 VAC 3 A at 30 VDC
= 0.4;
Resistive
load
5 A at 250 VAC 5 A at 30 VDC
Resistive load
(cos
5 A at 250 VAC 5 A at 30 VDC
Inductive
load
(cos
φ
= 0.4;
L/R = 7 ms)
2 A at 250 VAC 3 A at 30 VDC
φ
= 1)
Resistive
load
3 A at 250 VAC 3 A at 30 VDC
Inductive load
(cos
φ
= 0.4; L/R = 7 ms)
2 A at 250 VAC 3 A at 30 VDC
Inductive
load
(cos
φ
= 0.4;
L/R = 7 ms)
1 A at 250 VAC
1.5 A at 30 VDC
G
2
R
Contacts: Latching Models
Number of poles 1-pole 2-pole
Item
Contact type Single Single
Contact material Ag-alloy (Cd free)
Rated load
Rated carry current 5 A 3 A
Max. switching voltage 380 VAC, 125 VDC 380 VAC, 125 VDC
Max. switching current 5 A 3 A
Failure rate (P level) (reference value) *
* This value was measured at a switching frequency of 120 operations/min.
Load
Resistive load
(cos
φ
= 1)
5 A at 250 VAC 5 A at 30 VDC
100 mA at 5 VDC 10 mA at 5 VDC
Inductive load
(cos
φ
= 0.4; L/R = 7 ms)
3.5 A at 250 VAC
2.5 A at 30 VDC
Resistive load
(cos
φ
= 1)
3 A at 250 VAC 3 A at 30 VDC
(cos
1.5 A at 250 VAC 2 A at 30 VDC
Inductive load
φ
= 0.4; L/R = 7 ms)
5
Page 6
G2R PCB Power Relay
G
2
R
Flux Protection/Plug-in Relays
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1 0 5 10 20 30 50 100 500
AC resistive load
DC resistive load
AC inductive load (cosφ = 0.4)
DC inductive load (L/R = 7 ms)
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1 0 5 10 20 30 50 100 500
AC inductive load (cosφ = 0.4)
DC inductive load (L/R = 7 ms)
DC resistive load
AC resistive load
Characteristics
Standard Relays
Item Number of poles 1-pole 2-pole Contact resistance *1 30 mΩ max. 50 mΩ max. Operate time *2 15 ms max. Release time *2 AC: 10 ms max.; DC: 5 ms max. Max. operating frequency
Mechanical 18,000 operations/hr
Electrical 1,800 operations/hr
Insulation resistance *3 1,000 MΩ min.
Dielectric strength
Insulation distance
Vibration resistance
Shock resistance
Durability
Between coil and contacts Between contacts of different polarity Between contacts of the same polarity Between coil and contacts
Destruction
Malfunction
Destruction 1,000 m/s
Malfunction
Mechanical
Electrical
5,000 VAC, 50/60 Hz for 1 min
-
3,000 VAC, 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min
Clearance: 8 mm, Creepage: 8 mm
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
200 m/s
2
when no energized
100m/s AC coil: 10,000,000 operations min.; DC coil: 20,000,000 operations min.
(at 18,000 operations/hr)
100,000 operations min.
(at 1,800 operations/hr under rated load)
2
2
when energized;
Ambient operating temperature -40°C to 70°C (with no icing) Ambient operating humidity 5% to 85% Weight Approx. 17 g (Approx. 20 g *4)
Note: The values here are initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage-drop method. *2. Measurement conditions: Rated operating voltage applied, not including
contact bounce.
*3. Measurement conditions: The insulation resistance was measured with a
500 VDC megohmmeter at the same locations as the dielectric strength was measured.
*4. Value for quick-connect terminals.
Engineering Data
Double-winding Latching Relays
Item Number of poles 1-pole 2-pole Contact resistance *1 30 mΩ max. 50 mΩ max.
Set
Reset
Max. operating frequency Insulation resistance *4 1,000 MΩ min.
Dielectric strength
Insulation distance
Vibration resistance
Shock resistance
Durability
Ambient operating temperature
Ambient operating humidity 5% to 85% Weight Approx. 17 g
Note: The values here are initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage-drop method. *2. Measurement conditions: Rated operating voltage applied, not including
contact bounce. *3. Measurement couditions: Rated operating voltage applied. *4. Measurement conditions: The insulation resistance was measured with a
500 VDC megohmmeter at the same locations as the dielectric strength
was measured.
Time *2 20 ms max. Min. set pulse width Time *2 20 ms max. Min. reset pulse width *3 Mechanical 18,000 operations/hr Electrical 1,800 operations/hr
Between coil and contacts Between contacts of different polarity Between contacts of the same polarity Between set and reset coils Between coil and contacts
Destruction
Malfunction
Destruction 1,000 m/s
Malfunction
Mechanical
Electrical
*3 30 ms
30 ms
5,000 VAC, 50/60 Hz for 1 min
3,000 VAC, 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min
Clearance: 8 mm, Creepage: 8 mm
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
Set: 500m/s Reset: 200m/s
100,000 operations min. (at 1,800
2
Armature OFF
10,000,000 operations min
(at 18,000 operations/hr)
operations/hr under rated load)
-40°C to 70°C (with no icing or condensation)
2
2
Contact OFF
Maximum Switching Capacity
G2R-1, G2R-1A, G2R-1-T, G2R-1A-T G2R-1-E, G2R-1A-E G2R-1Z, G2R-1AZ
50
16
10
Switching current (A)
5
DC resistive load
DC inductive load
1
0.5
0.1
(L/R = 7 ms)
0 5 10 20 30 50 100 500
AC resistive load
AC inductive load (cosφ = 0.4)
Switching voltage (V)
G2R-1-H, G2R-1A-H, G2R-2, G2R-2A G2R-2-H, G2R-2A-H
50
10
5
Switching current (A)
DC resistive load
1
0.5
DC inductive load (L/R = 7 ms)
0.1 0 5 10 20 30 50 100 500
AC resistive load
AC inductive load (cosφ = 0.4)
Switching voltage (V)
50
10
Switching current (A)
5
DC resistive load
1
0.5
0.1 0 5 10 20 30 50 100 500
DC inductive load (L/R = 7 ms)
AC resistive load
AC inductive load (cosφ = 0.4)
Switching voltage (V)
6
Page 7
G2R PCB Power Relay
Switching voltage (V)
50
10
5
1
0.5
0.1 0 5 10 20 30 50 100 500
AC resistive load
DC resistive load
DC inductive load (L/R = 7 ms)
AC inductive load (cosφ = 0.4)
Switching current (A)
Fully Sealed Relays
Switching voltage (V)
50
10
5
1
0.5
0.1 0 5 10 20 30 50 100 300 500
AC inductive load (cosφ = 0.4)
Switching current (A)
AC resistive load
DC resistive load
DC inductive load (L/R = 7 ms)
Flux Protection/Plug-in Relays
250 VAC/30 VDC resistive load
30 VDC inductive load (L/R = 7ms)
Durability (x10
4
operations)
Switching current (A)
1,000
500
300
100
50
30
10
5
3
0
2 4 5 6 7.5 8 10 12 14
250 VAC inductive load (cosφ = 0.4)
Durability (x10
4
operations)
Switching current (A)
1,000
500
300
100
50
30
10
5
3
0
1 2 3 4 5 6
30 VDC inductive load (L/R = 7ms)
250 VAC/30 VDC resistive load
250 VAC inductive load (cosφ = 0.4)
G2RK-1A, G2RK-1 G2RK-2A, G2RK-2
50
10
5
Switching current (A)
3
AC resistive load
DC resistive load
1
0.5
0.1 0 5 10 20 30 50 100 500
DC inductive load (L/R = 7 ms)
AC inductive load (cosφ = 0.4)
Switching voltage (V)
G2R-14, G2R-1A4 G2R-24, G2R-2A4 G2R-1Z4, G2R-1AZ4
50
10
Switching current (A)
5
DC resistive load
1
0.5
0.1 0 5 10 20 30 50 100 300 500
DC inductive load (L/R = 7 ms)
AC resistive load
AC inductive load (cosφ = 0.4)
Switching voltage (V)
50
10
Switching current (A)
5
DC resistive load
1
0.5
0.1 0 5 10 20 30 50 100 300 500
DC inductive load (L/R = 7 ms)
AC resistive load
AC inductive load (cosφ = 0.4)
Switching voltage (V)
Durability
G
2
R
G2R-1, G2R-1A, G2R-1-T, G2R-1A-T G2R-1-E, G2R-1A-E G2R-1Z, G2R-1AZ
1,000
500
300
operations)
4
100
50
Durability (x10
30
10
5
3
0
250 VAC/30 VDC resistive load
250 VAC inductive load (cosφ = 0.4) 30 VDC inductive load (L/R = 7ms)
2 4 6 8 10 12 14 16 18
Switching current (A)
1,000
500
300
operations)
4
100
50
Durability (x10
30
10
5
3
0
1 2 3 4 5 6
30 VDC inductive load (L/R = 7ms)
250 VAC inductive load (cosφ = 0.4)
G2R-1-H, G2R-1A-H, G2R-2, G2R-2A G2R-2-H, G2R-2A-H
1,000
500
300
operations)
4
100
50
Durability (x10
30
10
5
3
0
250 VAC/30 VDC resistive load
30 VDC inductive load (L/R = 7ms)
250 VAC inductive load (cosφ = 0.4)
1 1.5 2 3 4
Switching current (A)
250 VAC/30 VDC resistive load
Switching current (A)
7
Page 8
G2R PCB Power Relay
G
2
R
Switching current (A)
1,000
500
300
100
50
30
10
5
3
0
1 2 2.5 3 3.5 4 5 6
Durability (x10
4
operations)
250 VAC/30 VDC resistive load
30 VDC inductive load (L/R = 7ms)
250 VAC inductive load (cosφ = 0.4)
Fully Sealed Relays
Switching current (A)
1,000
500
300
100
50
30
10
5
3
0
2 4 6 8 10 12
250 VAC/30 VDC resistive load
30 VDC inductive load (L/R = 7ms)
Durability (x10
4
operations)
250 VAC inductive load (cosφ = 0.4)
Switching current (A)
1,000
500
300
100
50
30
10
5
3
0
1 1.5 2 2.5 3 4 5 6
250 VAC/30 VDC resistive load
30 VDC inductive load (L/R = 7ms)
Durability (x10
4
operations)
250 VAC inductive load (cosφ = 0.4)
Z
Z'
Shock direction
Unit: m/s
2
Y
Y
Y'
Y'
X
X
X'
X'
SPST-NO (1a)
SPST-NC (1c)
1,000
1,000
800
600
400
200
200
400
600
800
Z Z'
Test Conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with and without energizing the Relays to check the number of contact malfunctions. Requirement: 200 m/s
2
when
energized; 100m/s
2
when de-energized
Z
Z'
Shock direction
Unit: m/s
2
Y
Y
Y'
Y'
X
X
X'
X'
SPST-NO (1a)
SPST-NC (1c)
1,000
1,000
800
600
400
200
200
400
600
800
Z Z'
270
Test Conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with and without energizing the Relays to check the number of contact malfunctions. Requirement: 200 m/s
2
when
energized; 100m/s
2
when de-energized
Decrement of keep-power (%)
Elapsed time (H)
Number of Relays: 50 pcs Measurement: after the relay kept static by applying a rated voltage, leave the relay at room temperature of 20°C to 30°C, and high temperature of 80°C ± 2°C respectively, to measure how the keep-power varies with time.
50 100 500
1,000 5,000 10,000
160
140
120
100
80
60
40
20
0
MAX MIN
)
MAX MIN
)
Room temperature
High temperature
G2RK-1A, G2RK-1 G2RK-2A, G2RK-2
1,000
500
300
operations)
4
100
50
Durability (x10
30
10
5
3
250 VAC/30 VDC resistive load
30 VDC inductive load (L/R = 7ms)
250 VAC inductive load (cosφ = 0.4)
0
1 1.5 2 2.5 3 4
Switching current (A)
G2R-14, G2R-1A4 G2R-24, G2R-2A4 G2R-1Z4, G2R-1AZ4
1,000
500
300
operations)
Ambient Temperature vs. Maximum Coil Voltage
Ambient Temperature vs. Must Operate and Must Release Voltage
4
100
50
Durability (x10
30
10
5
3
0
30 VDC inductive load (L/R = 7ms)
250 VAC inductive load (cosφ = 0.4)
1 2 3 4 5 6
G2R-1 G2R-2
250
200
170
150 140
Maximum coil voltage (%)
110 100
AC coil
50
DC coil
100
Sample: G2R-1 Number of Relays: 5 pcs
80
60
40
20
Must operate voltage Must release voltage
max.
X
min.
max.
X
min.
100
Sample: G2R-2 Number of Relays: 5 pcs
80
60
40
20
250 VAC/30 VDC resistive load
Switching current (A)
Must operate voltage Must release voltage
max.
X
min.
max.
X
min.
0
25 20 30 40 50 60 70 80 90 100
Note: The maximum coil voltage refers to the maximum
value in a varying range of operating power voltage, not a continuous voltage.
Shock Malfunction G2R-1
8
Number of Relays: 5 pcs G2R-2 Number of Relays: 5 pcs
Ambient temperature (°C)
0
Must-operate/must-release voltage (On the basis of rated voltage) (%)
60 40 20 0 20 40 60 80
Ambient temperature (°C)
0
Must-operate/must-release voltage (On the basis of rated voltage) (%)
60 40 20 0 20 40 60 80
Ambient temperature (°C)
Keep-power decrement with time G2RK-1
Page 9
G2R PCB Power Relay
** Average value
** With AC coil or “-H” models: 0.3.
1 2 3
5 4
3.5 3.5
(2.7)
20 (2.1)
1 0.5** 0.5
0.16
0.3
4
(0.3)
25.5 max. (25.3)*
29 max.
(28.8)*
13 max.
(12.7)*
7.5 Five, 1.3-dia.
holes
(No coil polarity)
Relays with PCB Terminals (SPDT (1c) Relays) G2R-1(-Z) G2R-1Z G2R-1-H
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
This illustration is the G2R-1 model.
** Average value
** With AC coil or “-H” models: 0.3.
1 3
5 4
3.5
(2.7)
20 (2.1)
1 0.5** 0.3
0.16
4
(0.3)
25.5 max. (25.3)*
29 max.
(28.8)*
13 max.
(12.7)*
7.5 Four, 1.3-dia.
holes
(No coil polarity)
Relays with PCB Terminals (SPST-NO (1a) Relays) G2R-1A(-Z) G2R-1AZ G2R-1A-H
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
This illustration is the G2R-1A model.
123
76
4
85
* Average value
0.3 10.5
0.16
0.3
4
(0.3)
25.5 max. (24.9)*
29 max.
(28.6)*
13 max.
(12.6)*
2.5
2.5
(2.1)
20
(2.1)55
(2.7)
7.5
Eight, 1.3-dia. holes
(No coil polarity)
Relays with PCB Terminals (SPDT (1c) /High-capacity Relays) G2R-1-E(Z)
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
1364
85
* Average value
0.3
0.16
0.3
4
(0.3)
25.5 max. (24.9)*
29 max.
(28.6)*
13 max.
(12.6)*
2.5
2.5
(2.1)
20
(2.1)5
(2.7)
7.5
Six, 1.3-dia. holes
1
(No coil polarity)
Relays with PCB Terminals (SPST-NO (1a)/High-capacity Relays) G2R-1A-E(Z)
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
Note: Orientation marks are indicated as follows:
Dimensions
G
2
R
9
Page 10
G2R PCB Power Relay
G
2
R
* Average value
12 3
54
3.5 3.5
(2.7)
20(2.1)
10.50.5
0.16
0.3
4
25.5 max. (24.8)*
29 max.
(28.6)*
13.5 max. (12.9)*
7.5 Five, 1.3-dia.
holes
(No coil polarity)
Relays with PCB Terminals (SPDT (1c) Relays) G2R-14(-Z)(-U) G2R-1Z4
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
* Average value
10.5
0.16
0.3
4
25.5 max. (24.8)*
29 max.
(28.6)*
13.5 max. (12.9)*
13
54
3.5
(2.7)
20(2.1)
7.5 Four, 1.3-dia.
holes
(No coil polarity)
Relays with PCB Terminals (SPST-NO (1a) Relays) G2R-1A4(-Z)(-U) G2R-1AZ4
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
* Average value
1
-
+
S
3 4
7
2
-
+
R
6 5
3.5 3.5
(2.7)
20
5
(2.1)
1
0.3 1
4
(0.3)
25.5 max. (25.2)*
29 max.
(28.8)*
13 max.
(12.8)*
7.5 Seven, 1.3-dia.
holes
(After confirming coil
polarity, wire correctly.)
0.5
0.5
1 0.16
Double-winding Latching Relays with PCB Terminals (SPDT (1c) Relays) G2RK-1
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
1
1
+
S
4
7
2
+
R
65
3.5
(2.7)
20
5
(2.1)
7.5 Six, 1.3-dia.
holes
* Average value
0.50.3
0.161
4
(0.3)
25.5 max. (25.2)*
29 max.
(28.8)*
13 max.
(12.8)*
(After confirming coil
polarity, wire correctly.)
Double-winding Latching Relays with PCB Terminals (SPST-NO (1a) Relays) G2RK-1A
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
* Average value
1 0.5
0.50.3
1 0.15
4
(0.3)
25.5 max. (25.3)*
29 max.
(28.8)*
13 max.
(12.8)*
1
-
+
S
10
2
-
+
R
9
3 4
8 7
5
6
2.5
2.5
(2.1)
20
(2.1) 5 5 5
(2.7)
(2.7)
7.5
Ten, 1.3-dia. holes
(After confirming coil
polarity, wire correctly.)
Double-winding Latching Relays with PCB Terminals (DPDT (2c) Relays) G2RK-2
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
* Average value
1 0.5
0.3 1 0.15
4
(0.3)
25.5 max. (25.3)*
29 max.
(28.8)*
13 max.
(12.8)*
2.5
2.5
(2.1)
20
(2.1) 5 5
(2.7)
(2.7)
7.5
Eight, 1.3-dia. holes
1
-
+
S
10
2
-
+
R
9
4 7 5
6
(After confirming coil
polarity, wire correctly.)
Double-winding Latching Relays with PCB Terminals (DPST-NO (2a) Relays) G2RK-2A
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
10
Note: Orientation marks are indicated as follows:
Page 11
G2R PCB Power Relay
10.50.5
0.15
0.3
4
(0.3)
25.5 max. (25.2)*
29 max.
(28.8)*
13 max.
(12.7)*
* Average value
1
8
23
76
4
5
2.5
2.5
(2.1)
20
(2.1)55
(2.7)
7.5
Eight, 1.3-dia. holes
(No coil polarity)
Relays with PCB Terminals (DPDT (2c) Relays) G2R-2(-Z) G2R-2-H
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
10.5
0.3
0.15
4
(0.3)
25.5 max. (25.2)*
29 max.
(28.8)*
13 max.
(12.7)*
* Average value
1
8
3
6
4
5
2.5
2.5
(2.1)
20
(2.1)5
(2.7)
7.5
Six, 1.3-dia. holes
(No coil polarity)
Relays with PCB Terminals (DPST-NO (2a) Relays) G2R-2A G2R-2A-H G2R-2A-Z
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
* Average value
10.50.5
0.15
0.3
4
25.5 max. (24.7)*
29 max.
(28.6)*
13.5 max. (12.8)*
1
8
23
76
4
5
2.5
2.5
(2.1)
20
(2.1)55
(2.7)
7.5
Eight, 1.3-dia. holes
(No coil polarity)
Relays with PCB Terminals (DPDT (2c) Relays) G2R-24(-Z)(-U)
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
* Average value
10.5
0.15
0.3
4
25.5 max.
29 max.
(28.6)*
13.5 max. (12.8)*
1
8
3
6
4
5
2.5
2.5
(2.1)
20
(2.1)5
(2.7)
7.5
Six, 1.3-dia. holes
(No coil polarity)
Relays with PCB Terminals (DPST-NO (2a) Relays) G2R-2A4(-Z)(-U)
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
Note: Orientation marks are indicated as follows:
G
2
R
11
Page 12
G2R PCB Power Relay
G
2
R
38
Two M3 or two 3.5 dia.
30.5 max. (29.7)*
45 max.
(43.9)*
14 max.
(13.1)*
7.5
5.2 5.2
17.5
4.75
Five, 1.3-dia. holes
0.5
8.5
29.5 max.
2.5
1
5
24
3
* Average value
(No coil polarity)
Note: Model number of quick-connect terminal is 187.
Relays with Quick-connect Terminals (SPDT (1c) Relays) G2R-1-T
Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
Relays with Quick-connect Terminals (SPST-NO (1a) Relays) G2R-1A-T
Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
30.5 max. (29.7)*
7.5
Four, 1.3-dia. holes
2.5
17.4
4.75
45 max.
(43.9)*
5.2
0.5
29.5 max.
* Average value
8.5
14 max.
(13.1)*
38
Note: Model number of quick-connect terminal is 187.
Two M3 or two 3.5 dia.
1
4
5
(No coil polarity)
Note: Orientation marks are indicated as follows:
3
12
Page 13
G2R PCB Power Relay
Approved Standards
• The approval rating values for overseas standards are different from the performance values determined individually. Confirm the
values before use.
UL Recognized: 1-pole
Model
G2R-1A
G2R-1A4
G2R-1A-H
G2R-1A-T
G2R-1
G2R-14
G2R-1-H
G2R-1-T
G2R-1AZ
G2R-1AZ4
G2R-1Z
G2R-1Z4
G2R-1A-E
G2R-1-E
Contact
form
SPST-NO
(1a)
SPDT
(1c)
SPST-NO
(1a)
SPDT
(1c)
SPST-NO
(1a)
SPDT
(1c)
2-pole
Model
G2R-2A
G2R-2A4
G2R-2A-H
G2R-2
G2R-24
G2R-24-H
Contact
form
DPST-NO
(2a)
DPDT
(2c)
File No. E41643
Coil ratings Contact ratings
10 A, 250 VAC (General Use) at 40°C
5 A, 277 VAC (General
5 to 110 VDC 12 to 220 VAC
5 to 110 VDC 12 to 220 VAC
5 to 110 VDC 12 to 220 VAC
Coil ratings Contact ratings
5 to 110 VDC 12 to 220 VAC
Use) at 40°C
5 A, 30 VDC (Resistive) at 40°C
TV-3 (N. O. only) at 40°C
10 A, 250 VAC (General Use) at 40°C
5 A, 30 VDC (Resistive) at 40°C
16 A, 250 VAC (General Use) at 40°C 16 A, 30 VDC (Resistive) at 40°C TV-3 (N. O. only) at 40°C
5 A, 250 VAC (General Use) at 40°C
5 A, 30 VDC (Resistive) at 40°C
TV-3 (N. O. only) at 40°C
Number of
test
operations
100,000
6,000
100,000
25,000
6,000
30,000
6,000
25,000
Number of
test
operations
6,000
100,000
25,000
CSA Certified:
File No. LR31928
1-pole
Model
G2R-1A
G2R-1A-H
G2R-1A-T
G2R-14
G2R-1-H
G2R-1-T
G2R-1AZ
G2R-1AZ4
G2R-1Z
G2R-1Z4
G2R-1A-E
G2R-1-E
Contact
form
SPST-NO
(1a)
SPDT
(1c)
SPST-NO
(1a)
SPDT
(1c)
SPST-NO
(1a)
SPDT
(1c)
5 to 110 VDC
12 to 220 VAC
5 to 110 VDC
12 to 220 VAC
5 to 110 VDC
12 to 220 VAC
2-pole
Model
G2R-2A
G2R-2A4
G2R-2A-H
G2R-2
G2R-24
G2R-24-H
Contact
form
DPST-NO
(2a)
5 to 110 VDC
12 to 220 VAC
DPDT
(2c)
EN/IEC, VDE Certified:
Model
G2R-1(A)-E 1
G2R-( )
Contact
form
5, 6, 12, 24,
48, 100 VDC
200/220 VAC
5, 6, 12, 24,
48, 100 VDC
1
200/220 VAC
5, 6, 12, 24,
48, 100 VDC
2
200/220 VAC
Coil ratings Contact ratings
10 A, 250 VAC (General Use) at 40°C
10 A, 30 VDC (Resistive) at 40°C
TV-3 (N. O. only) at 40°C
5 A, 250 VAC (General Use) at 40°C
5 A, 30 VDC (Resistive) at 40°C
16 A, 250 VAC (General Use) at 40°C 16 A, 30 VDC (Resistive) at 40°C TV-3 (N. O. only) at 40°C
Coil ratings Contact ratings
5 A, 250 VAC (General Use) at 40°C
5 A, 30 VDC (Resistive) at 40°C
TV-3 (N. O. only) at 40°C
Registration No. 40015012
Coil ratings Contact ratings
12, 24,
100/110,
12, 24,
100/110,
12, 24,
100/110,
16 A, 250 VAC (cos
φ
= 1.0) at 70°C
10 A, 250 VAC (cos
φ
= 1.0) at 40°C
10 A, 30 VDC (0 ms) at 40°C
5 A, 250 VAC (cos
φ
= 1.0) at 40°C
5 A, 30 VDC (0 ms) at 40°C
Number of
test
operations
100,000G2R-1A4
100,000 G2R-1
25,000
6,000
6,000
25,000
Number of
test
operations
6,000
100,000
25,000
Number of
test
operations
100,000
G
2
R
EN, TÜV Certified:
Model
G2R-1(A)-E 1
G2R-( )
Contact
form
1
2
Registration No. R50030327
Coil ratings Contact ratings
5 to 110 VDC
12 to 220 VAC
5 to 110 VDC
12 to 220 VAC
5 to 110 VDC
12 to 220 VAC
16 A, 250 VAC (cos
φ
= 1.0) at 70°C
10 A, 250 VAC (cos
φ
= 1.0) at 70°C
10 A, 30 VDC (0 ms) at 70°C
5 A, 250 VAC (cos
φ
= 1.0) at 40°C
5 A, 30 VDC (0 ms) at 40°C
Number of
test
operations
100,000
13
Page 14
G2R PCB Power Relay
G
2
R
Mounting
• When mounting a number of relays on
a PCB, be sure to provide a minimum
mounting space of 5 mm between the
two juxtaposed relays as shown
below.
Handling
• The terminals are compatible with
Faston receptacle #187 and are
suitable for positive-lock mounting.
Use only Faston terminals with the
specified numbers.
Select leads for connecting Faston
receptacles with wire diameters that
are within the allowable range for the
load current.
Do not apply excessive force to the
terminals when mounting or
dismounting the Faston receptacle.
Also, do not insert terminals at an
angle, or insert/remove multiple
terminals at the same time. Be sure to
insert and remove terminals carefully
one at a time.
Refer to the following table for
examples of positive-lock connectors
made by AMP. Contact the
manufacturer directly for details on
connectors including availability.
Note: The numbers shown in parentheses are for
air-feeding.
Minimum Pulse Width of Double-
winding Latching Relays
• The minimum pulse width shown in
the table of characteristics are values
measured under conditions of ambient
temperature at 23°C with rated
operating voltage imposed on coil. The
Relay may not provide a satisfactory
performance as its holding ability
decreases depending on the operating
circuit conditions and ambient
temperature, or decreases due to
degradation over time.
In actual operation, impose to the coil
a rated operating voltage with a pulse
width that is suitable to the actual load,
and reset the setting at least once a
year, to correspond to the degradation
over time.
• When using the Relay in a strong
magnetic field environment, the
magnetic body may be demagnetized
due to the influence of environment,
causing the Relay to malfunction.
Therefore, do not use the Relay in a
strong magnetic field environment.
Degradation over Time of Double­winding Latching Relays Holding Ability
• If a double-winding latching Relay is
used left set for an extended period,
changes over time will degrade the
magnetic force, and the reduction in
holding ability may cause the set
status to be released. This is also
because of the properties of semi-
hard magnetic material, and the rate
of degradation over time depends on
the ambient environment (e.g.,
temperature, humidity, vibration, and
presence or absence of external
magnetic fields).Perform maintenance
at least once a year by resetting,
applying the rated voltage again, and
then setting.
Wiring High Capacity (-E) Models
• High-capacity models (-E) have a
structure that connects two terminals
from one contact.
When designing the circuit, use both
terminals.
If you use only one terminal, the relay
may be unable to satisfy specified
performance.
Correct Use
5 mm
min.
5 mm min.
Ty pe
Receptacle
terminals
Positive housing
#187
(Width
4.75)
AMP170330-1
(170324-1)
AMP170331-1
(170325-1)
AMP170332-1
(170326-1)
AMP172074-1 (natural color) AMP172074-4 (yellow) AMP172074-5 (green) AMP172074-6 (blue)
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K013-E1-16
1014(0207)(O)
Note: Do not use this document to operate the Unit.
Precautions
Please refer to “PCB Relays Common Precautions” for correct use.
14
Loading...