![](/html/7b/7b80/7b80d6fdd8af17caf0e39474c49c3922a2d10f7bf8c7cd5d85b0270b5dbb37b2/bg1.png)
1
UV Power Monitor F3UV
Monitor the Output of a UV Light Source
through an Optical Fiber Cable
Monitors with Optical Fibers
Head Unit withstands temperatures of up to
300°C.
Easy-to-read digital display of measurement
values.
Harmful UV light converted to visible light before
performing measurements. This feature prevents
deterioration of the Amplifier’s light receiving
element.
Monitors with Built-in Amplifiers
Deterioration due to UV light prevented by
protective structure.
Confirm the output status of the UV light source
with an operation indicator.
Filtering Cover (reduces light intensity by 1/6.5)
also available.
Ordering Information
Monitors with Built-in Amplifiers
Main Unit
Appearance
Intensity range of incident light
Output
Model number
1 to 30 mW/cm
2
Analog voltage output (1 to 5 V)
F3UV-A30
0.2 to 3 mW/cm
2
F3UV-A03
Note:
Does not function as a sensor
.
Monitors with Optical Fibers
Amplifier
Appearance
Connection
method
Outputs T
ransistor type
Model number
Pre-wired cable
•
Judgement output
• Answer-back output
output
PNP F3UV-XW41
Head Unit
Appearance
W
avelength range of
incident light
Max. temperature
Model number
Remarks
200 to 370 nm
300_C
(Use at temperatures below
the Fiber Unit’
s rated
operating temperature.)
F3UV-HM
Includes two M8 nuts
and one mounting plate.
![](/html/7b/7b80/7b80d6fdd8af17caf0e39474c49c3922a2d10f7bf8c7cd5d85b0270b5dbb37b2/bg2.png)
F3UV
F3UV
2
Fiber Units
Compatible
Amplifier Units
Compatible
Head Units
Appearance Max.
temperature
Intensity range of
incident light
(see note)
Model number
Quantity
F3UV-XW11,
F3UV-XW41
F3UV-HM
M4 threads, 2 m
300_C
10 to 300 mW/cm2F32-300
1
M4 threads, 2 m
70_C
10 to 300 mW/cm2F32-70
Note: The
values given are for a standard UV
light source with a central wavelength of 360 nm, measured with a standard illumination meter
(and
for use in combination with the specified Amplifier and Head Unit). The
power range is one for which teaching to 100% is possible.
Accessories (Sold Separately)
Accessories for Monitors with Built-in Amplifiers
Appearance Name Model
number
Protective T
ube (Protects the cord.)
F39-CU1M
Protective Cover (Protects the display.) F39-HU2
1/6.5 Filtering Cover
F39-HU1
Mounting Bracket
F39-L9
Accessories for Monitors with Optical Fibers
Appearance Name Model
number
Quantity
Applicable Fiber Units
Protective Tube
(Protects the fiber
.)
F39-FU1M 1 F32-70
![](/html/7b/7b80/7b80d6fdd8af17caf0e39474c49c3922a2d10f7bf8c7cd5d85b0270b5dbb37b2/bg3.png)
F3UV
F3UV
3
Specifications
Ratings/Characteristics
Monitors with Built-in Amplifiers (Main Unit)
Item F3UV-A30 F3UV-A03
Incident
light power range
1
1 to 30 mW/cm
2
0.2 to 3 mW/cm
2
Incident light wavelength range
200 to 370 nm
Power indicator
Green LED
Operation indicator
Orange LED (lights with an output between 4 and 5 V)
Sensitivity adjustment
One-turn variable adjuster
Power supply voltage
12 to 24 VDC
±10%
Current consumption
15 mA max.
Response time
2
300 ms max. 400 ms max.
Output
3
1 to 5 V (with an of
fset voltage of 0.2 V min.)
Connection impedance
100 kΩ min.
Repetitive accuracy
±
2% F
.S. max.
T
emperature drift
0.2% of F
.S./°C max.
Ambient operating illumination4Fluorescent light 1,000 lx max.
Fluorescent light 500 lx max.
Ambient temperature
Operating: –10° to 70°CStorage: –25° to 80
°C
Ambient humidity
Operating:
35% to 85%
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
1,000 V AC 50/60 Hz for 1 min
V
ibration resistance
10 to 150 Hz, 0.1-mm amplitude in X, Y
, and Z directions
(8 minutes of vibration × 10 repetitions= total time 80 minutes)
Shock resistance
150 m/s2 three times each in the ±X, ±Y, and ±Z directions
Degree of protection
Conforms to IEC IP30
Connection method
Pre-wired cable with a standard length of 2 m
W
eight (packed)
78 g
Material Casing: Die-cast zinc
Window: Synthetic quartz glass
Accessories
Operation Manual
Note: 1.
Using a standard UV light source and UV illumination meter in a power range for which analog output can be set to 5 V
.
2.
The response time is the rise time of the output signal to 10 to 90%.
3. An
output voltage up to 6 V can be output. Adjust the sensitivity so
that the output is less than 5 V
. The output is 0.2 to 1 V when there
is
no incident UV light.
4.
This value is the illumination at the receiver window maintaining an of
fset voltage of 1 V max. with the fluorescent light.
![](/html/7b/7b80/7b80d6fdd8af17caf0e39474c49c3922a2d10f7bf8c7cd5d85b0270b5dbb37b2/bg4.png)
F3UV
F3UV
4
Accessories (Sold Separately)
Protective Tube (Protects the Cord.)
Item
F39-CU1M
Head connector
Flexible tube
End cap
Ambient
temperature
–40°
to 100°C for operation and storage
(Use within the specified operating temperature range for the Monitor
.)
Ambient humidity
Operating:
35% to 85%
Storage: 35% to 95%
Bending radius
24 ± 5 mm
Max. pulling force
2 N-m max. between the head connector and tube, end cap and tube, or on the tube itself
Crush weight
9.8 N-m max. load on the side of the tube
Material
Head
connector
Nickel-plated brass
End cap
Tube
Stainless (SUS304)
Attachment M2 screws
Monitors with Optical Fibers
Amplifiers
Item
F3UV-XW11 F3UV-XW41
Power
supply voltage
12 to 24 VDC
±10%
Current consumption
75 mA max.
Outputs
Analog output
Current (4 to 20 mA) or voltage (1 to 5 V) (Monitoring mode or integral mode)
Judgement output
NPN open collector output, 100 mA max.,
PNP open collector output, 100 mA max.,
Answer-back output
residual voltage 1 V max.
(Monitoring mode or integral mode)
residual voltage 2 V max.
(Monitoring mode or integral mode)
Inputs
Remote teaching
input
ON:
0 V short-circuit (current 1 mA max.)
ON:
Power supply voltage short-circuit or 9 to
24 V (open-circuit current: 3 mA max.)
Reset input
OFF:
Open (open or 9 to 24 V)
OFF:
Open (open or 1.5 V max.)
Protective circuits
Reversed power supply polarity protection and output short-circuit protection
Response time
1
500 ms max.
Sensitivity setting
T
eaching function
Indicators Power supply/T
eaching indicator (green/red), Operation indicator (orange), 7-segment digital
percentage display (red), 7-segment digital threshold display (red)
Repetitive accuracy
±
2% F
.S. max.
Ambient operating illumination2Fluorescent light 1,000 lx max.
T
emperature drift
±
0.1% of F
.S./°C max.
Ambient temperature
Operating: –25 to 55°C (with no icing or condensation) Storage: –40 to 70°C (with no icing or
condensation)
Ambient humidity
Operating or storage: 35% to 85%
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
1,000 V AC 50/60 Hz between the leads and the case
V
ibration resistance
10 to 150 Hz, 0.1-mm amplitude or 15 m/s2 in X, Y
, and Z directions each for 2 hours
Shock resistance
150 m/s2 three times each in the X, Y
, and Z directions
Degree of protection
Conforms to IEC 60529 standards IP30
Connection method
Pre-wired cable with a standard length of 2 m
W
eight (packed)
Approx. 270 g
Material ABS plastic
Accessories
Operation Manual
Note: 1.
The response time is the rise time or fall time of the output signal to 10 to 90%.
2. The
ambient operating illumination is the illumination that changes the analog output +5% F
.S. at 200 lx; it is not the operational limit.
3. An
analog output of up to 6 V (or 24 mA) can be output. The output is 1 V (or 4 mA) when there is no incident UV light.
4. F
.S. stands for full scale. For a current output, full scale is 16 mA (4 to 20 mA). For a voltage output, full scale is 4 V (1 to 5 V).
![](/html/7b/7b80/7b80d6fdd8af17caf0e39474c49c3922a2d10f7bf8c7cd5d85b0270b5dbb37b2/bg5.png)
F3UV
F3UV
5
5. Definition
of the luminous energy integral: The physical unit of the luminous energy integral is energy (J:
joules) and this value is
calculated
by multiplying the UV intensity (mV)
by the time of exposure (s), but it is dimensionless when this sensor’s analog output
value
(V) is used for the UV intensity
. The integral is measured with an 1
1 ms sampling time.
Head Unit
Item
F3UV-HM
Incident light wavelength range
200 to 370 nm
T
emperature drift
–0.15%/°C max.
Ambient temperature
Operating or storage: –40° to 300°C (with no icing or condensation)
Ambient humidity
Operating or storage: 35% to 85% (with no icing or condensation)
W
eight (packed)
Approx. 300 g
V
ibration resistance
10 to 55 Hz, 0.75-mm amplitude or 10 m/s
2
Shock resistance
500 m/s
2
Material
Protective casing
Stainless steel (SUS303)
Fluorescent fiber
path
Functional fluoroglass
Accessories
M8 nut and mounting bracket
Fiber Units
Item
Model
F32-300 F32-70
Ambient temperature
(with no icing or condensation)
Operating: –40°
to 300
°C
*1
Storage: –40°
to 1
10°C
Operating: –40°
to 70
°C
Storage: –40°
to 70
°C
Ambient humidity
(with no icing or condensation)
Operating:
35 to 85%
Storage:
35 to 95%
Bending radius
25 mm min. 25 mm min.
Fiber outer sheathing material
SUS
Black polyethylene
Degree of protection
Conforms to IEC IP67
Standard fiber length
2 m
Note:
The maximum temperature is lower near the amplifier unit. See the Dimensions for details.
Accessories (Sold Separately)
Protective Tube (Protects the Fiber
.)
Item
F39-FU1M
1,000
Head connector
Flexible tube
End cap
Ambient
temperature
–40°
to 150°C for operation and storage
(Keep the ambient temperature within the range specified for the fiber within the tube.)
Ambient humidity
Operating:
35 to 85%
Storage:
35 to 95%
Bending radius
30 mm min.
Max. pulling force
1.5 N-m max. between the head connector and tube, 1.5 N-m max. between the end cap and
tube, and 2 N-m on the tube itself
Crush weight
29.4 N-m max. on the tube
Head connector
Nickel-plated brass
End cap