3E3JK
E3JK
Rating/Performance
E3JK
Sensor
type
Through-
beam
Retroflective model 
(with M.S.R. function)
Retroflective model 
(without M.S.R. function)
Diffuse-reflective
Item Model E3JK-5M#
E3JK-R2M
# E3JK-R2#3
E3JK-R4M
# E3JK-R4S3
E3JK-DS30M#E3JK-DS30S3
Sensing distance 5 m
2.5 m 
(When using the E39-R1)
4 m 
(When using the E39-R1)
300 mm 
(White paper 100x100 mm)
Standard sensing 
object
Opaque 14.8 
dia. min.
Opaque: 75 mm dia. min. ---
Differential 
distance
---
20% max. of sensing 
distance
Directional angle
Both emitter 
and receiver: 
3°C to 20°C
1° to 5° ---
Light source (wave 
length)
Infrared LED 
(950 nm)
Red LED (660 nm) Infrared LED (950 nm)
Power supply voltage
12 to 240 VDC ±10% ripple (p-p) : 10% max. 24 to 240 VAC ±10% 50/60 Hz
Current 
consumption
DC 3 W max. 2 W max.
AC 3 W max. 2 W max.
Control output
Relay 
output: 
250VAC 
3 A (cosϕ=1)  
max., 5 VDC 
10 mA min.
Relay 
output: 
250VAC 
3 A (cosϕ=1)  
max., 5 VDC 
10 mA min.
DC SSR Negative or positive common 
48 VDC 
100 mA max. 
Leak current 
0.1 mA max. 
With load 
short-circuit 
protection
Relay 
output: 
250VAC 
3 A (cosϕ=1) 
max., 5 VDC 
10 mA min.
DC SSR 
Negative common 
48 VDC 
100 mA max. 
Leak current 
0.1 mA max. 
With load shortcircuit protection
Relay 
output: 
250VAC 
3 A (cosϕ=1)  
max., 5 VDC 
10 mA min.
DC SSR Negative common 
48 VDC 
100 mA max. 
Leak current 
0.1 mA max. 
With load 
short-circuit 
protection
Life expectancy (relay 
output)
Mechanical
50 million times or more (switching frequency 18,000 times/hour)
Electrical
100 thousand times or more (switching frequency 18,000 times/hour)
Response time 30 ms max. 30 ms max. 5 ms max. 30 ms max. 5 ms max. 30 ms max. 5 ms max.
Sensitivity 
adjustment
--- Single-turn adjustment
Ambient 
illuminance
Incandescent lamp: 3,000 lux max.
Ambient 
temperature
Operating: -25°C to 55°C, Storage: -30°C to 70°C (with no icing or condensation)
Ambient humidity Operating: 45% to 85%RH, Storage: 35% to 95%RH (with no condensation)
Insulation 
resistance
20 MΩ min. at 500 VDC
Dielectric strength 1,500 VAC at 50/60 Hz for 1 minute
Vibration 
resistance
Destruction
10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Malfunction
10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions