Omron E3F2-7C4-M1-S, E3F2-7B4-S 2M, E3F2-7C4-S 2M, E3F2-7B4-M1-S, E3F2-R4B4-S-E 2M Datasheet

...
Cylindrical photoelectric sensor in M18 stainless steel housing
E3F2-SUS
The stainless steel housing provides enhanced detergent resistance and longer lifetime in demanding environments.
• Complete sensor portfolio in robust stainless steel housing
• Enhanced detergent resistance (ECOLAB certified)
• High power LED to compensate for dirt and misalign­ment
Selection Guide
Sensing method Sensing
Through-beam 7 m
Retro-reflective with M.S.R.
Diffuse-reflective 0.1 m (fixed,
Diffuse-reflective (background suppression)
*1.
Pre-wired connectors are available on request. Contact your OMRON representative.
*2.
Order reflector separately
*3.
Measured with E39-R1S
Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adapting the length of the cable
(e.g. E3F2-R4B4-S-E 5M). For other cable length please contact your OMRON sales representative.
*2
distance
0.1 to 4 m (adjustable)
wide beam)
0.3 m (adjustable)
0.1 m (fixed)
Connection method Order code
––2 m–
––
––2 m–
*3
––
––2 m–
––
––2 m–
––
––2 m–
––
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
PNP output NPN output
E3F2-7B4-S 2M E3F2-7C4-S 2M
E3F2-7B4-M1-S E3F2-7C4-M1-S
E3F2-R4B4-S-E 2M E3F2-R4C4-S-E 2M
E3F2-R4B4-M1-S-E E3F2-R4C4-M1-S-E
E3F2-DS10B4-S 2M E3F2-DS10C4-S 2M
E3F2-DS10B4-M1-S E3F2-DS10C4-M1-S
E3F2-DS30B4-S 2M E3F2-DS30C4-S 2M
E3F2-DS30B4-M1-S E3F2-DS30C4-M1-S
E3F2-LS10B4-S 2M E3F2-LS10C4-S 2M
E3F2-LS10B4-M1-S E3F2-LS10C4-M1-S
1E3F2-SUS
Accessories (Order separately)
Name Sensing distance (typical) Reflectors 4 m [100 mm] E39-R1S 60 x 40 mm
3 m [100 mm] E39-R48 60 x 40 mm, enhanced
5 m [100 mm] E39-R7 84 mm 6 m [100 mm] E39-R8 100 x 100 mm 5 m [100 mm] E39-R40 80 x 80 mm
Tape Reflectors 0.7 m [150 mm] E39-RS1 35 x 10 mm
1.1 m [150 mm] E39-RS2 35 x 40 mm
1.4 m [150 mm] E39-RS3 80 x 70 mm Lens Cap E39-F31 Mounting Bracket Y92E-B18 screw mount
*1.
Values in parentheses indicate the minimum required distance between the sensor and reflector.
Note: For detailed information about Accessories, refer to the main chapter “Accessories” at the end of the document.
*1
Model Remark
chemical resistance
Sensor I/O Connectors
Cord Shape Cable type Model Standard Straight 2 m Four-wire type,
5 m XS2F-D421-G80-A
M12 connector
L-shaped 2 m XS2F-D422-D80-A
5 m XS2F-D422-G80-A
Detergent resistant cable with SUS nuts
Straight 2 m Y92E-S12PVC4S2M-L
5 m Y92E-S12PVC4S5M-L
L-shaped 2 m Y92E-S12PVC4A2M-L
5 m Y92E-S12PVC4A5M-L
XS2F-D421-D80-A
2 Standard Photoelectric Sensors
Specifications
Ratings
Item E3F2-7# E3F2-R4#-# E3F2-DS10# E3F2-DS30# E3F2-LS10#4-# Sensing method Through-beam Retro-reflective Diffuse-reflective
Wide beam (fixed) Potentiometer
adjustment Power supply voltage 10 to 30 V DC Current consumption 50 mA max. 30 mA max. 25 mA max. 30 mA max. Sensing distance 7 m 0.1 to 4 m
(with E39-R1S)
Standard object Opaque:
11 mm dia. min.
Opaque: 56 mm dia. min.
0.1 m (5 x 5 cm white mat paper)
0.3 m
(10 x 10 cm white
mat paper)
Directional angle 3° to 20° 3° to 20° – Differential travel
20% max. 5% max
(hysteresis) Black/white error 3% max Response time Operation and Re-
1 ms max 2.5 ms max. 1 ms max.
set:
2.5 ms max. Control output Transistor (open collector), load current: 100 mA max. (residual voltage: 2 V max.) Power reset time 50 ms 100 ms max. 50 ms 100 ms Ambient illumination Incandescent lamp:3000 lx max. / Sunlight:10000 lx max. Ambient temperature Operating: -25 to 55 °C / Storage: -30 to 70 °C (with no icing or condensation) Ambient humidity Operating: 35% to 85% / Storage: 35% to 95% (with no condensation) Insulation resistance 20 MΩ min. at 500 V DC between energized parts and case Dielectric strength 1000 VAC max., 50 / 60 Hz for 1 min between energized parts and case Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hrs each direction (X, Y, Z) Shock resistance Destruction: 500 m/s Degree of protection
*1
IEC 60529 IP67, IP69K after DIN 40050-9
Light source (wave length) Infrared LED
2
each direction (X, Y, Z)
Red LED (660 nm) Infrared LED (880 nm) Red LED (660 nm)
(950 nm)
Indicators Light
incident / power in-
Light incident (red) / stability (green)
Light incident / power indicator for light
source (red) dicator for light source (red)
Sensitivity adjustment Fixed Adjustable Fixed Adjustable Fixed Connection method 2 m, 5 m pre-wired cable (PVC, dia. 4 mm (18 / 0.12)) or M12-connector Operation mode Light-ON or Dark-ON selectable by wiring Weight
(approx.)
Pre-wired (2 m) 180 g 90 g
Connector 120 g 50 g Circuit protection Output short-circuit and power supply reverse polarity Material Lens PMMA
*1.
Housing Stainless steel
The IP69k test according to DIN 40 050 part 9 is intended to simulate high pressure/steam cleaning. During the test 14-16l/min water at 80°C is sprayed onto the sensor from different angles with 8000-10000kPa. The sensor may not suffer any damaging effects from high pressure water in appearance and functionality.
*2.
Material-specification for stainless steel housing case: 1.4305 (W.-No.), 303 (AISI), 2346 (SS). For other stainless steel materials please contact your OMRON sales representative.
*2
Background suppression
0.1 m (10 x 10 cm white mat paper)
Output indicator (orange) / stability (green)
3E3F2-SUS
Engineering Data (Typical)
Operating Range (typical)
Through-beam Models E3F2-7#4-#
Diffuse-reflective Models E3F2-DS30#4-#
40
Sensitivity adjusted to maximum Sensitivity adjusted to 400 mm
30
20
10
white paper
(100 x 100 mm)
Distance X (mm)
Distance Y (mm)
0
–10
–20
–30
–40
Sensing distance adjustable between 0 and 550 mm
Object
Y
X
100 200 300 400 500 6000
Retro-reflective Models E3F2-R4#4#-#
250
Typical sensing distance E39-RS3 E39-R1S
200
E39-R40 E39-R7
150
E39-R8
100
50
0
-50
Distance Y (mm)
- 100
- 150
- 200
- 250 01 23456 789
Reflector
Y
X
Distance X (m)
Diffuse-reflective Models E3F2-DS10#4-# (wide-beam type)
15
10
5
0
–5
Distance Y (mm)
–10
–15
Object
Y
X
20 40 60 80 100 1200
Distance X (mm)
white paper
(50 x 50 mm)
140
Excess Gain Ratio vs. Distance (typical)
Through-beam Models E3F2-7#4-#
100
10
Excess gain
1
0.1 2 4 6 8 10 120
Distance X (m)
Retro-reflective Models E3F2-R4#4#-#
100
Reflectors: E39-RS3 E39-R1S E39-R40 E39-R7
10
Excess Gain
1
0.1 024 6 810
E39-R8
Distance X (m)
Diffuse-reflective Models E3F2-DS10#4-# (wide beam type)
100
Sensing object:
10
Grey paper
Excess gain
1
(18% reflectivity)
0.1 20 40 60 80 100 1200
White paper (90% reflectivity)
Distance X (mm)
50 x 50 mm
140
4 Standard Photoelectric Sensors
Diffuse-reflective Models E3F2-DS30#4-#
100
10
Excess gain
1
Grey paper (18% reflectivity)
0.1 200 400 600 800 10000
Sensitivity adjusted to maximum Sensing object: 100 x 100 mm
White paper (90% reflectivity)
Distance X (mm)
Light spot vs sensing distance Incline (left and right) Incline (up and down)
Background suppression Models E3F2-LS#
6
4
2
Spot diameter(mm)
0
050100150
Distance(mm)
Object material vs sensing distance
Background suppression Models E3F2-LS#
120
100
80
Sensing distance (mm)
60
Background suppression Models E3F2-LS#
20,00%
10,00%
0,00%
-10,00%
Sensing Distence movement (%)
-20,00%
-40 -30 -20 -10 0 10 20 30 40
Incline Angle (˚)
Background suppression Models E3F2-LS#
20,00%
10,00%
0,00%
-10,00%
Sensing Distence movement (%)
-20,00%
-40 -30 -20 -10 0 10 20 30 40
Incline Angle (˚)
40
20
0
White
Veneer
paper
Card­board
Black paper
Black rubber
SUS Mirror
surface
Material
5E3F2-SUS
Operation
Output Circuits
Structure of Sensor I/O Connector
Classification Wire color
Brown
White
DC
Blue
Black
PNP Output
Model
Connector pin No.
Output transistor status
––
Use
Power supply (+V)
Mode selec­tion Lon/Don
Power supply (0 V)
Output
Timing chart
1 2 3
4
XS2F-D42#-D80-# XS2F-G42#-G80-#
Connection method
Output circuit
Through-beam emitter
Power indicator (red)
Main circuit
Connector Pin Arrangement
Brown White Blue Black
Brown
1
Blue
3
1
2
4
3
10 to 30 VDC
0 V
E3F2-@B4-@ (except for
E3F2-LS10B4-@)
ON when light is incident. (Light-ON)
ON when light is interrupted. (Dark-ON)
Incident Interrupted
Output indicator (red)
Output transistor
Load (relay)
Incident Interrupted
Output indicator (red)
Output transistor
Load (relay)
OFF
OFF
Operate Release
OFF
OFF
Operate Release
ZD: VZ = 36 V
1
2
4
3
Z
: VZ = 36 V
D
Brown
1
Z
D
Black
4
Blue
3
Pink
2
Brown
1
Black
4
Blue
3
Pink
2
Light indicator
Connect the
ON
ON
ON
ON
pink (Pin ➁) and brown (Pin ) cords or open the pink cord (Pin ).
Connect the pink (Pin ➁) and blue (Pin ) cords.
* Only on models
Light indicator
Red
Green
E3F2-R4B4-@ and E3F2-D1B4-@
Red
Green
Stability indicator*
Main circuit
Connector Pin Arrangement
Stability indicator*
Main circuit
100 mA max.
Mode selection
100 mA max.
Mode selection
10 to 30 VDC
Load
0 V
10 to 30 VDC
Load
0 V
Connector Pin Arrangement
* Only on models
E3F2-R4B4-@ and E3F2-D1B4-@
1
2
4
3
6 Standard Photoelectric Sensors
Model
Output transistor status
Timing chart
Connection method
Output circuit
ON when light is incident. (Light-ON)
E3F2-LS10B4-@
ON when light is interrupted. (Dark-ON)
Note: Terminal numbers for connector type.
Incident Interrupted
Output indicator (orange)
Output transistor
Load (relay)
Incident Interrupted
Output indicator (orange)
Output transistor
Load (relay)
OFF
OFF
Operate Release
OFF
OFF
Operate Release
ZD: VZ = 36 V
1
2
4
3
Z
: VZ = 36 V
D
Brown
1
Z
D
Black
4
Blue
3
Pink
2
Brown
1
Black
4
Blue
3
Pink
2
Output indicator
Connect the
ON
ON
ON
ON
pink (Pin ➁) and brown (Pin ) cords or open the pink cord (Pin ).
Connect the pink (Pin ➁) and blue (Pin ) cords.
Output indicator
Stability indicator*
Orange
Green
Connector Pin Arrangement
Stability indicator*
Orange
Green
Main circuit
Main circuit
100 mA max.
Mode selection
100 mA max.
Mode selection
10 to 30 VDC
Load
0 V
10 to 30 VDC
Load
0 V
Connector Pin Arrangement
1
2
4
3
7E3F2-SUS
NPN Output
Model
E3F2-@C4-@ (except for
E3F2-LS10C4-@)
E3F2-LS10C4-@
Output transistor status
Timing chart
Connection method
Output circuit
Through-beam emitter
Power indicator (red)
Main circuit
––
ON when light is incident. (Light-ON)
ON when light is interrupted. (Dark­ON)
ON when light is incident. (Light-ON)
ON when light is interrupted. (Dark­ON)
Incident Interrupted
Output indicator (red)
Output transistor
Load (relay)
Incident Interrupted
Output indicator (red)
Output transistor
Load (relay)
Incident Interrupted
Output indicator (red)
Output transistor
Load (relay)
Incident Interrupted
Output indicator (orange)
Output transistor
Load (relay)
OFF
OFF
Operate Release
OFF
OFF
Operate Release
OFF
OFF
Operate Release
OFF
OFF
Operate Release
Connector Pin Arrangement
Output indicator
Connect the
ON
ON
ON
ON
ON
ON
ON
ON
pink (Pin ➁) and brown (Pin ) cords or open the pink cord (Pin ).
Connect the pink (Pin ➁) and blue (Pin ) cords.
Connect the pink (Pin ➁) and brown (Pin ) cords or open the pink cord (Pin ).
Connect the pink (Pin ➁) and blue (Pin ) cords.
* Only on models
Output indicator
* Only on models
Output indicator
Red
E3F2-R4C4-@ and E3F2-D1C4-@
Red
E3F2-R4C4-@ and E3F2-D1C4-@
Orange
Output indicator
Orange
Stability indicator*
Green
Connector Pin Arrangement
Stability indicator*
Green
Connector Pin Arrangement
Stability indicator*
Green
Connector Pin Arrangement
Stability indicator*
Green
Connector Pin Arrangement
Main circuit
Main circuit
Main circuit
Main circuit
2
2
2
2
1
2
3
Z
: VZ = 36 V
D
1
3
Z
D
1
3
Z
D
1
3
Z
D
1
3
4
4
: VZ = 36 V
4
: VZ = 36 V
4
: VZ = 36 V
4
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
3
Brown
Black
Blue
Pink
Brown
Black
Blue
Pink
Brown
Black
Blue
Pink
Brown
Black
Blue
Pink
Brown
Blue
100 mA max.
Mode selection
100 mA max.
Mode selection
100 mA max.
Mode selection
100 mA max.
Mode selection
10 to 30 VDC
0 V
10 to 30 VDC
Load
0 V
10 to 30 VDC
Load
0 V
10 to 30 VDC
Load
0 V
10 to 30 VDC
Load
0 V
Note: Terminal numbers for connector type.
8 Standard Photoelectric Sensors
Dimensions Note: All units are in millimeters unless otherwise indicated
Cable type Connector type
Without potentiometer E3F2-7#-S
E3F2-DS10#4-S E3F2-LS10#4-S
E3F2-7#-M1-S E3F2-DS10#4-M1-S E3F2-LS10#4-M1-S
42.3 37
4
With potentiometer E3F2-DS30#4-S
E3F2-R4#4-S
49.3
42.3 37
4
64.9
64.9
4.8 dia
4 dia
Light indicator
M18x1 6g
4.8 dia
Sensitivity adjustor
Light indicator
M18x1 6g
16.4 dia
4 dia
optical area
optical area
16.4 dia
27.7
27.7
6.2
6.2
24
24
65.5
42.3
37
4
E3F2-DS30#4-M1-S E3F2-R4#4-M1-S
65.5
49.3
42.3 37
4
76
76
4.8 dia
M12x1 6g
Light indicator
M18x1 6g
Sensitivity adjustor
Light indicator
M18x1 6g
optical area
16.4 dia
4.8 dia
16.4 dia
M12x1 6g
optical area
27.7
27.7
24
6.2
24
6.2
Accessories (Order Separately)
Reflectors
E39-R1 E39-R1S
Two, 3.5 dia.
5259.9
Material, reflective
surface: acrylic
Rear surface: ABS
E39-R7
40.3 34
7
1.6
7.5
8
2.7
7.4
4.5
84
9E3F2-SUS
Reflectors
for M3
E39-R8 E39-R40
9
100
92
8.7
84.5
77
Tape Reflectors
E39-RS3
Installation
Mounting Bracket Y92E-B18
ffor M3
92
100
for M3
77
84.5
E39-RS1
35
80
0.6
10
4 x R1
Reflecting surface
0.7
Adhesive tape
E39-RS2
70
Adhesive tape side
4-R1
35
4 x R1
40
Reflecting surface
0.7
Adhesive tape
Lens Cap E39-F31
Glass plate
Note: Hexagon bolt: M5 x 32 Material: plastic
10 Standard Photoelectric Sensors
Metal rim Gasket
20 dia.
E3F2
4 max.
Safety precautions
! Warning
This product is not designed or rated for directly or indirectly ensuring safety of persons. Do not use it for such a purpose.
! Caution
Do not use the product with voltage in excess of the rated voltage. Excess voltage may result in malfunc­tion or fire.
Never use the product with an AC power supply. Otherwise, explostion may result.
When cleaning the product, do not apply a high-pres­sure spray of water to one part of the product. Other­wise, parts may become damaged and the degree of protection may be degraded.
High-temperature environments may result in burn injury.
Precautions for Safe Use
The following precautions must be observed to ensure safe operation of the Sensor.
Operating Environment
Do not use the Sensor in an environment where explosive or flammable gas is present.
Connecting Connectors
Be sure to hold the connector cover when inserting or removing the connector. Be sure to tighten the connector lock by hand; do not use pliers or other tools. If the tightening is insufficient, the degree of protection will not be maintained and the Sensor may become loose due to vibration. The appropriate tightening torque is 0.39 to 0.49 N·m for M12 connectors.
Load
Do not use a load that exceeds the rated load.
Rotation Torque for Sensitivity Adjustment
Adjust with a torque of 0.05 N·m or less.
Modifications
Do not attempt to disassemble, repair, or modify the Sensor.
Outdoor Use
Do not use the Sensor in locations subject to direct sunlight.
Cleaning
Do not use thinner, alcohol, or other organic solvents. Otherwise, the optical properties and degree of protection may be degraded.
Surface Temperature
Burn injury may occur. The Sensor surface temperature rises de­pending on application conditions, such as the surrounding tem­perature and the power supply voltage. Use caution when operating or washing the Sensor.
Precautions for Correct Use
Do not use the Sensor in any atmosphere or environment that exceeds the ratings.
Do not install the Sensor in the following locations.
(1)Locations subject to direct sunlight (2)Locations subject to condensation due to high humidity (3)Locations subject to corrosive gas (4)Locations where the Sensor may receive direct vibration or
shock
Connecting and Mounting
(1)The maximum power supply voltage is 30 VDC. Before turning
the power ON, make sure that the power supply voltage does not exceed the maximum voltage.
(2)Laying Sensor wiring in the same conduit or duct as high-volt-
age wires or power lines may result in malfunction or damage due to induction. As a general rule, wire the Sensor in a sepa­rate conduit or use shielded cable.
(3)Use an extension cable with a minimum thickness of 0.3 mm
and less than 100 m long. (4)Do not pull on the cable with excessive force. (5)Pounding the Photoelectric Sensor with a hammer or other
tool during mounting will impair water resistance. (6)Mount the Sensor using a bracket (sold separately).
Do not exceed a torque of 20.0 Nm when tightening mounting
nuts. (7)Be sure to turn OFF the power supply before inserting or re-
moving the connector.
Cleaning
Never use thinner or other solvents. Otherwise, the Sensor sur­face may be dissolved.
Power Supply
If a commercial switching regulator is used, ground the FG (frame ground) terminal.
Power Supply Reset Time
The Sensor will be able to detect objects 100 ms after the power supply is tuned ON. Start using the Sensor 100 ms or more after turning ON the power supply. If the load and the Sensor are con­nected to separate power supplies, be sure to turn ON the Sensor first.
Turning OFF the Power Supply
Output pulses may be generated even when the power supply is OFF. Therefore, it is recommended to first turn OFF the power supply for the load or the load line.
Load Short-circuit Protection
This Sensor is equipped with load short-circuit protection, but be sure to not short circuit the load. Be sure to not use an output cur­rent flow that exceeds the rated current. If a load short circuit oc­curs, the output will turn OFF, so check the wiring before turning ON the power supply again. The short-circuit protection circuit will be reset.
Water Resistance
Do not use the Sensor in water, rainfall, or outdoors.
2
11E3F2-SUS
WARRANTY
OMRON’s exclusive warranty is that the products are free from de­fects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EX­PRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MER­CHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WAR­RANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDI­RECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the in­dividual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRAN­TY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PROD­UCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR EN­SURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OM­RON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer’s application or use of the product. At the customer’s request, OMRON will provide applicable third party
certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combina­tion with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad sys­tems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate in­dustry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual perfor­mance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be as­signed to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for man­ufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a pro­grammable product, or any consequence thereof.
In the interest of product improvement, specifications are subject to change without notice.Cat. No. E59E-EN-01
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands Phone: +31 23 568 13 00 Fax: +31 23 568 13 88 www.industrial.omron.eu
12 Standard Photoelectric Sensors
Loading...