Omron E2S DATASHEET

Miniature Square Inductive Proximity Sensor
E2S
• Miniature housing with long sensing ranges
• Front ans side facing sensing surfaces
Features
5.5 mm
The 5.5 mm x 5.5 mm type permits smaller, space-saving ma­chines and devices.
Adopted for more compact machines and devices.
Ultra small housing
5.5mm
1 kHz
IP67
Full sealing structure housing, degree of protection IEC60529 IP67.
1/20
Significantly lower current consumption. The 0.8 mA (for 24 VDC) leakage current for the DC 2-wire type has a ratio of ap­proximately 1/20 compared to the conventional DC 3-wire type. Optimum solution for multiple-sensor applications such as cam switches.
High-Speed Response
Environment-Resistant Types
Low Current Consumption (Com­pared to conventional models)
E2S
D-61E2S
Ordering Information
Sensors
DC 2-wire Models
Model
Shape Sensing surface Sensing distance
NO NC
Front face E2S-W11 * E2S-W12
Unshielded
* Models with different response frequency are available (NO only). These model numbers take the form E2S-###B (e.g., E2S-W11B)
End face
Front face
End face
1.6mm
2.5mm
E2S-Q11 * E2S-Q12
E2S-W21 * E2S-W22
E2S-Q21 * E2S-Q22
DC 3-wire Models
Shape Sensing surface Sensing distance
Front face
End face
Front face
Unshielded
* Models with different response frequency are available (NO only). These model numbers take the form E2S-###B (e.g., E2S-W11B)
End face
Front face
End face
Front face
End face
1.6mm
2.5mm
1.6mm
2.5mm
Output
specifications
NPN
PNP
Operating status
Model
Operating status
NO NC
E2S-W13* E2S-W14 E2S-Q13* E2S-Q14 E2S-W23* E2S-W24 E2S-Q23* E2S-Q24 E2S-W15* E2S-W16 E2S-Q15* E2S-Q16 E2S-W25* E2S-W26 E2S-Q25* E2S-Q26
Accessories (Order Separately)
Mounting Brackets
Shape Model Quantity Remarks
Y92E-C1R6
Y92E-C2R5
Y92E-D1R6 ---
Y92E-D2R5 ---
Provided with E2S-#1
Provided with E2S-#2
1
Nomenclature
E2S - ####
ABCDE
A Compact square
series
B Sensing direction W: Front face sensing Q: End face sensing
C Size and sensing distance (standard sensing object) 1: 5.5 x 5.5 mm, 1.6 mm (iron) 2: 8 x 8 mm, 2.5 mm (iron)
##
##
D Output 1: DC 2-wire NO 2: DC 2-wire NC 3: DC 3-wire NPN NO 4: DC 3-wire NPN NC 5: DC 3-wire PNP NO 6: DC 3-wire PNP NC
E Different response frequency No: Standard B: Different response frequency
D-62 Inductive Sensors
Rating/Performance
DC 2-wire Models
Model Item Sensing surface Front face End face Front face End face Sensing distance 1.6 mm ±10% 2.5 mm ±15% Setting distance Differential distance 10% max. Sensing object Ferrous metal (Sensitivity lowers with non-ferrous metals) Standard sensing
object Response frequency 1 kHz min. Rated supply voltage
(operating voltage)
Leakage current
Switching
Control output
Indicator lamp
Operating status (with sensing object approaching)
* The response frequencies for DC switching are average values measured under the condition that the distance between each sensing object is twice as large as the
size of the sensing object and the sensing distance set is half of the maximum sensing distance.
capacity Residual
voltage
0 to 1.2 mm
Iron, 12 x 12 x 1 mm Iron, 15 x 15 x 1 mm
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
0.8 mA max.
3 to 50 mA DC max.
3 V max. (under load current of 50 mA with cable length of 1 m)
##1 models: Operation indicator(red LED), Operation set indicator(green LED) ##2 models: Operation indicator(red LED)
##1 models: NO ##2 models: NC
E2S-W11 E2S-W12
E2S-Q11 E2S-Q12
E2S-W21 E2S-W22
0 to 1.9 mm
E2S-Q21 E2S-Q22
DC 3-wire Models
Model Item Sensing surface Front face End face Front face End face Front face End face Front face End face Sensing distance 1.6 mm ±10% 2.5 mm ±15% 1.6 mm ±10% 2.5 mm ±15% Setting distance Differential distance 10% max. Sensing object Ferrous metal Standard sensing
object Response frequency 1 kHz min. Rated supply voltage
(operating voltage) Current consumption 13 mA max. (24 VDC, unload)
Switching
Control output
Indicator lamp Operation indicator (orange) Operating status
(with sensing object approaching)
* The response frequencies for DC switching are average values measured under the condition that the distance between each sensing object is twice as large as the
size of the sensing object and the sensing distance set is half of the maximum sensing distance.
capacity Residual
voltage
E2S-W13 E2S-W14
0 to 1.2 mm
Iron, 12 x 12 x 1 mm Iron, 15 x 15 x 1 mm Iron, 12 x 12 x 1 mm Iron, 15 x 15 x 1 mm
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
NPN open collector 100 mA max. (30 VDC max.) PNP open collector 50 mA max. (30 VDC max.)
1 V max. (under load current of 50 mA with cable length of 1 m)
##3 models: NO ##4 models: NC
E2S-Q13 E2S-Q14
E2S-W23 E2S-W24
0 to 1.9 mm 0 to 1.2 mm 0 to 1.9 mm
E2S-Q23 E2S-Q24
E2S-W15 E2S-W16
##5 models: NO ##6 models: NC
E2S-Q15 E2S-Q16
E2S-W25 E2S-W26
E2S-Q25 E2S-Q26
E2S
D-63E2S
Loading...
+ 5 hidden pages