Omron CP1E-N**S*D, CP1E-E**SD, CP1E-E**D, CP1E-N**D, CP1E-NA**D User Manual

Cat. No. W479-E1-10
SYSMAC CP Series
CP1E-ESD- CP1E-NSD- CP1E-ED- CP1E-ND- CP1E-NAD-
CP1E CPU Unit Hardware
USER’S MANUAL
NOTE
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON.
No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Neverthe­less, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.
Trademarks
• Microsoft, Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and other countries.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
Copyrights
Microsoft product screen shots reprinted with permission from Microsoft Corporation.
SYSMAC CP Series CP1E-ESD- CP1E-NSD- CP1E-ED- CP1E-ND- CP1E-NAD- CP1E CPU Unit Hardware
User’s Manual
Revised July 2017

Introduction

Thank you for purchasing a SYSMAC CP-series CP1E Programmable Controller. This manual contains information required to use the CP1E. Read this manual completely and be sure
you understand the contents before attempting to use the CP1E.

Intended Audience

This manual is intended for the following personnel, who must also have knowledge of electrical sys­tems (an electrical engineer or the equivalent).
Personnel in charge of installing FA systems
Personnel in charge of designing FA systems
Personnel in charge of managing FA systems and facilities

Applicable Products

CP-series CP1E CPU Units
Basic Models CP1E-E(S)D-
A basic model of CPU Unit that support basic control applications using instructions such as basic, movement, arithmetic, and comparison instructions.
Application Models CP1E-N/NA(S)D- An application model of CPU Unit that supports connections to Programmable Terminals, invert­ers, and servo drives.
The CP Series is centered around the CP1H, CP1L, and CP1E CPU Units and is designed with the same basic architecture as the CS and CJ Series.
Always use CP-series Expansion Units and CP-series Expansion I/O Units when expanding I/O capacity. I/O words are allocated in the same way as for the CPM1A/CPM2A PLCs, i.e., using fixed areas for inputs and outputs.
CP1E CPU Unit Hardware User’s Manual(W479)
1

CP1E CPU Unit Manuals

Information on the CP1E CPU Units is provided in the following manuals. Refer to the appropriate manual for the information th at is required.
This Manual
Mounting and
1
Setting Hardware
2
Wiring
Connecting
3
Online to the PLC
4
Software Setup
CP1E CPU Unit Hardware User’s Manual(Cat. No. W479)
· Names and specifications of the parts of all Units
· Basic system configuration for each CPU Unit
· Connection methods for Expansion I/O Units and Expansion Units
· Wiring methods for the power supply
· Wiring methods between external I/O devices and Expansion I/O Units or Expansion Units
Connecting Cables for CX-Programmer Support Software
CP1E CPU Unit Software User’s Manual(Cat. No. W480)
Procedures for connecting the CX-Programmer Support Software
Software setting methods for the CPU Units (PLC Setup)
CP1E CPU Unit Instructions Reference Manual(Cat. No. W483)
5
Creating the Program
· Program types and basic information
· CPU Unit operation
· Internal memory
· Built-in CPU functions
· Settings
Checking and
6
Debugging Operation
· Checking I/O wiring, setting the Auxiliary Area settings, and performing trial operation
· Monitoring and debugging with the
Maintenance and
7
Troubleshooting
Error codes and remedies if a problem occurs
2
CX-Programmer
CP1E CPU Unit Hardware User’s Manual(W479)
Detailed information on
programming instructions

Manual Configuration

The CP1E CPU manuals are organized in the sections listed in the followin g tabl es. Refe r to th e ap pro­priate section in the manuals as required.
CP1E CPU Unit Hardware User’s Manual (Cat. No. W479) (This Manual)
Section Contents
Section 1 Overview and Specifica­tions
Section 2 Basic System Configura­tion and Devices
Section 3 Part Names and Functions This section describes the part names and functions of the CPU Unit,
Section 4 Programming Device This section describes the features of the CX-Programmer used for pro-
Section 5 Installation and Wiring This section describes how to install and wire CP1E Units. Section 6 Troubleshooting This section describes how to troubleshoot problems that may occur
Section 7 Maintenance and Inspec­tion
Section 8 Using Expansion Units and Expansion I/O Units
Appendices The appendices provide information on dimensions, wiring diagrams,
This section gives an overview of the CP1E, describes its features, and provides its specifications.
This section describes the basic system configuration and unit models of the CP1E.
Expansion I/O Units, and Expansion Units in a CP1E PLC .
gramming and debugging PLCs, as well as how to connect the PLC with the Programming Device by USB.
with a CP1E PLC, including the error indications provided by the CP1E Units.
This section describes periodic inspections, the service life of the Bat­tery, and how to replace the Battery.
This section describes application methods for Expansion Units.
and wiring serial communications for the CP1E.
CP1E CPU Unit Software User’s Manual (Cat. No. W480)
Section Contents
Section 1 Overview This section gives an overview of the CP1E, describes its application
procedures.
Section 2 CPU Unit Memory This section describes the types of internal memory in a CP1E CPU
Unit and the data that is stored.
Section 3 CPU Unit Operation This section describes the operation of a CP1E CPU Unit. Section 4 Programming Concepts This section provides basic information on designing ladder programs
for a CP1E CPU Unit.
Section 5 I/O Memory This section describes the types of I/O memory areas in a CP1E CPU
Unit and the details.
Section 6 I/O Allocation This section describes I/O allocation used to exchange data between
the CP1E CPU Unit and other units.
Section 7 PLC Setup This section describes the PLC Setup, which are used to perform basic
settings for a CP1E CPU Unit.
Section 8 Overview and Allocation of Built-in Functions
Section 9 Quick-response Inputs This section describes the quick-response inputs that can be used to
Section 10 Interrupts This section describes the interrupts that can be used with CP1E PLCs,
This section lists the built-in functions and describes the overall applica­tion flow and the allocation of the functions.
read signals that are shorter than the cycle time.
including input interrupts and scheduled interrupts.
CP1E CPU Unit Hardware User’s Manual(W479)
3
Section Contents
Section 11 High-speed Counters This section describes the high-speed counter inputs, high-speed
counter interrupts, and the frequency measurement function.
Section 12 Pulse Outputs This section describes positioning functions such as trapezoidal control,
jogging, and origin searches.
Section 13 PWM Outputs This section describes the variable-duty-factor pulse (PWM) outputs. Section 14 Serial Communications This section describes communications with Programmable Terminals
(PTs) without using communications programming, no-protocol commu­nications with general components, and connections with a Modbus­RTU Easy Master, Serial PLC Link, and host computer.
Section 15 Analog I/O Function This section describes the built-in analog function for NA-type CPU
Units.
Section 16 Built-in Functions This section describes PID temperature control, clock functions, DM
backup functions, security functions.
Section 17 Ethernet Option Board This section gives an overview of the Ethernet Option Board, describes
its setting methods, I/O memory allocations, troubleshooting, how to connect the CX-Programmer, and how to install an Ethernet network.
Section 18 Analog Option Board This section describes an overview of the Analog Option Board,
describes its installation and setting methods, memory allocations, star­tup operation, refresh time, troubleshooting and how to use the Analog Option Board.
Section 19 Operating the Program­ming Device
Appendices The appendices provide lists of programming instructions, the Auxiliary
This section describes basic functions of the CX-Programmer, such as using the CX-Programmer to write ladder programs to control the CP1E CPU Unit, to transfer the programs to the CP1E CPU Unit, and to debug the programs.
Area, cycle time response performance, PLC performance at power interruption.
CP1E CPU Unit Instructions Reference Manual (Cat. No. W483)
Section Contents
Section 1 Summary of Instructions This section provides a summary of instructions used with a CP1E CPU
Unit.
Section 2 Instruction This section describes the functions, operands and sample programs of
the instructions that are supported by a CP1E CPU Unit.
Section 3 Instruction Execution Times and Number of Steps
Section 4 Monitoring and Comput­ing the Cycle Time
Appendices The appendices provide a list of instructions by Mnemonic and ASCII
This section provides the execution times for all instructions used with a CP1E CPU Unit.
This section describes how to monitor and calculate the cycle time of a CP1E CPU Unit that can be used in the programs.
code table for the CP1E CPU Unit.
4
CP1E CPU Unit Hardware User’s Manual(W479)

Manual Structure

5 - 3
5 Installation and wiring
CP1E CPU Unit Hardware User’s Manual(W479)
5
5-2 Installation
5-2-1 Installation Location
DIN Track Installation
1
2
Release
DIN Track mounting pins
3
DIN Track
DIN Track mounting pins
Precautions for Correct Use
Tighten terminal block screws and cable screws to the following torques. M4: 1.2 N·m M3: 0.5 N·m
Use a screwdriver to pull down the DIN Track mounting pins from the back of the Units to release them, and mount the Units to the DIN Track.
Fit the back of the Units onto the DIN Track by catching the top of the Units on the Track and then pressing in at the bottom of the Units, as shown below.
Press in all of the DIN Track mounting pins to securely lock the Units in place.
5-2 Installation
5-2-1 Installation Location
Level 1 heading Level 2 heading Level 3 heading
Level 2 heading
Step in a procedure
Manual name
Special Information (See below.)
Level 3 heading
Page tab
Gives the current headings.
Indicates a step in a procedure.
Gives the number of the section.
This illustration is provided only as a sample and may not literally appear in this manual.
Icons are used to indicate precautions and additional information.
Precautions for Safe Use Precautions on what to do and what not to do to ensure using the product safely.
Precautions for Correct Use Precautions on what to do and what not to do to ensure proper operation and performance.
Additional Information Additional information to increase understanding or make operation easier.

Page Structure and Icons

The following page structure and icons are used in this manual.

Special Information

Special information in this manual is classified as follows:
CP1E CPU Unit Hardware User’s Manual(W479)
5

Terminology and Notation

Term Description
E-type CPU Unit A basic model of CPU Unit that support basic control applications using instructions such
as basic, movement, arithmetic, and comparison instructions. Basic models of CPU Units are called “E(S)-type CPU Units” in this manual. The models of E(S)-type CPU Units are shown below. CP1E-ED- CP1E-ESD-
N-type CPU Unit An application model of CPU Unit that supports connections to Programmable Terminals,
inverters, and servo drives. Application models of CPU Units are called “N(S)-type CPU Units” in this manual. The models of N(S)-type CPU Units are shown below. CP1E-ND- CP1E-NSD- CP1E-NS1D-
NA-Type CPU Unit An application model of CPU Unit that supports built-in analog and connections to Pro-
grammable Terminals, inverters, and servo drives. Application models of CPU Units with built-in analog are called “NA-type CPU Units” in
this manual.
CX-Programmer A programming device that applies for programming and debugging PLCs.
The CX-Programmer includes the Micro PLC Edition CX-Programmer (CX-One Lite), the CX-Programmer (CX-One) and the CX-Programmer for CP1E.
This manual describes the unique applications and functions of the Micro PLC Edition CX-Programmer version 9.03 or higher/CX-Programmer for CP1E.
“CX-Programmer” refers to the Micro PLC Edition CX-Programmer version 9.03 or higher/CX-Programmer for CP1E in this manual.
Note E20/30/40(S) and N20/30/40(S) CPU Units are supported by CX-Programmer
version 8.2 or higher. E10/14(S), N14/60(S) and NA20 CPU Units are supported by CX-Programmer version 9.03 or higher. E60S CPU Units are supported by CX­Programmer version 9.42 or higher.
6
CP1E CPU Unit Hardware User’s Manual(W479)

Sections in this Manual

1
2
3
4
5
6
7
8
A
1
5
6
7
2
3
4
8
A
Overview and Specifications
Troubleshooting
Maintenance and Inspection
Basic System Configuration and Devices
Part Names and Functions
Programming Device
Installation and Wiring
Using Expansion Units and Expansion I/O Units
Appendices
CP1E CPU Unit Hardware User’s Manual(W479)
7

CONTENTS

Introduction ...............................................................................................................1
CP1E CPU Unit Manuals...........................................................................................2
Manual Structure. ......................................................................................................5
Terms and Conditions Agreement.........................................................................12
Safety Precautions..................................................................................................14
Precautions for Safe Use........................................................................................19
Operating Environment Precautions.....................................................................22
Regulations and Standards....................................................................................23
Related Manuals......................................................................................................24
Section 1 Overview and Specifications
1-1 CP1E Overview........................................................................................................................ 1-2
1-1-1 Overview of Features..................................................................................................................1-2
1-1-2 Features......................................................................................................................................1-3
1-2 Basic Operating Procedure........ ... ... ... ... ....................................... ... .... ... ... ... .........................1-8
1-3 Specifications.......................................................................................................................... 1-9
1-3-1 General Specifications................................................................................................................1-9
1-3-2 Characteristics ..........................................................................................................................1-10
1-3-3 Functional Specifications..........................................................................................................1-12
1-4 Difference between E/N/NA-type and E/NS(1)-type ............................................... 1-14
Section 2 Basic System Configuration and Devices
2-1 Basic System Configuration.......................... ... ... .... ... ....................................... ... ... ... ... .... .....2-2
2-1-1 Basic System Configuration Using an E(S)-type CPU Unit ..................................................2-2
2-1-2 Basic System Configuration Using an N/NA(S)-type CPU Unit.........................................2-3
2-2 CPU Units........... ... ... ....................................... ... ... .... ... ....................................... ... ... ............... 2-4
2-2-1 CPU Unit Models ........................................................................................................................2-4
2-2-2 Optional Products........................................................................................................................2-9
2-2-3 Unit Versions of CPU Units.......................................................................................................2-11
2-3 Expansion I/O Unit or Expansion Unit................................................................................. 2-13
2-3-1 Expandable CPU Units .............................................................................................................2-13
2-3-2 Connection Methods.................................................................................................................2-13
2-3-3 Maximum Number of I/O Points for an Expansion I/O Unit or Expansion Unit ........................2-13
2-3-4 Expansion I/O Units and Expansion Units ................................................................................2-14
2-3-5 Restrictions on System Configuration.......................................................................................2-16
2-4 Unit Current Consumption and External Power Supply Capacity.................................... 2-18
2-4-1 External Power Supply Capacity When Expansion I/O Units or Expansion Units are
Connected.................................................................................................................................2-18
2-4-2 Current Consumption............................................ ... ... .................................... ... .......................2-19
8
CP1E CPU Unit Hardware User’s Manual(W479)
Section 3 Part Names and Functions
3-1 CPU Units........... ... ... ....................................... ... ... .... ... ....................................... ... ... ............... 3-2
3-1-1 E10/14/20(S) or N14/20 CPU Units ..........................................................................................3-2
3-1-2 E30/40/60(S), N30/40/60(S) or NA20 CPU Units ....................................................................3-7
3-1-3 Common I/O Specifications....................................................... ..................................... .. .........3-13
3-1-4 Optional Serial Communications Port for N/NA(S)-type CPU Units ................................3-19
3-1-5 Analog Option Board for N/NA-type CPU Units...................................... .. ... .......................3-24
3-2 Expansion I/O Units...............................................................................................................3-28
3-2-1 Expansion Input Unit.................................................................................................................3-28
3-2-2 Expansion Output Units ............................................................................................................3-29
3-2-3 Expansion I/O Units ..................................................................................................................3-31
3-2-4 I/O Specifications......................................................................................................................3-33
Section 4 Programming Device
4-1 Applicable Programming Devices for CP1E......................................................................... 4-2
4-1-1 Applicable Programming Devices...............................................................................................4-2
4-1-2 CX-Programmer..........................................................................................................................4-3
4-1-3 Operating Environment and System Configuration.....................................................................4-4
4-1-4 Features of the CX-Programmer.................................................................................................4-4
4-1-5 Installing the Software.................................................................................................................4-7
4-2 Connecting by USB................................................................................................................. 4-8
4-2-1 Connecting by USB.....................................................................................................................4-8
4-2-2 Installing the USB Driver.............................................................................................................4-9
4-3 Connection Method with a Serial Port.............................................................. ...................4-16
Section 5 Installation and Wiring
5-1 Fail-safe Circuits......................................................................................................................5-2
5-2 Installation................................................................................................................................ 5-3
5-2-1 Installation Location....................................................................................................................5-3
5-2-2 Unit Arrangement.................................................. ... ... .................................... ............................5-6
5-2-3 Installation...................................................................................................................................5 -7
5-2-4 Connecting Expansion I/O Units and Expansion Units .............................................................5-12
5-3 Wiring ..................................................................................................................................... 5-14
5-3-1 Wiring Procedure ................................................................... ... ................................................5-14
5-3-2 Wiring Power Supply and Ground Lines ...................................................................................5-14
5-3-3 I/O Wiring..................................................................................................................................5-17
5-3-4 Wiring Safety and Noise Controls.............................................................................................5-21
5-3-5 Relay Output Noise Reduction Methods...................................................................................5-22
Section 6 Troubleshooting
6-1 Troubleshooting CPU Unit Errors.............. ............................................................................6-2
6-1-1 Errors and Remedies..................................................................................................................6-2
6-1-2 Checking Errors ................................................................................................. ... ......................6-2
6-1-3 Checking Detailed Status....................................................... ... ..................................... .. ...........6-3
6-1-4 Reading Error Log Information....................................................................................................6-3
6-1-5 Types of Errors............................................................................................................................6-5
6-1-6 Error Processing Flowchart.........................................................................................................6-6
6-1-7 No Operation When Power Is Supplied......................................................................................6-7
6-1-8 Fatal Errors .................................................................................................................................6-7
6-1-9 CPU Errors................................................................................................................................6-11
6-1-10 Non-fatal Errors.........................................................................................................................6-12
6-1-11 Other Errors ..............................................................................................................................6-14
CP1E CPU Unit Hardware User’s Manual(W479)
9
6-2 Troubleshooting Unit Errors.................................................................................................6-15
6-2-1 Inputs........................................................................................................................................6-15
6-2-2 Outputs......................................................................................................................................6-16
6-2-3 Built-in Analog...........................................................................................................................6-17
6-2-4 CX-Programmer Connection.....................................................................................................6-18
Section 7 Maintenance and Inspection
7-1 Periodic Maintenance and Inspection................................................................................... 7-2
7-1-1 Tools Required for Inspections...................................................................................................7-2
7-1-2 Periodic Inspection......................................................................................................................7-2
7-1-3 Inspection and Maintenance.......................................................................................................7-3
7-1-4 Unit Replacement Precautions....................................................................................................7-4
7-2 Replacing the Battery in N/NA(S)-type CPU Units...................................................... 7-5
Section 8 Using Expansion Units and Expansion I/O Units
8-1 Analog Input Units................................................................................................................... 8-2
8-1-1 Overview.....................................................................................................................................8-2
8-1-2 Part Names and Functions..........................................................................................................8-2
8-1-3 Specifications..............................................................................................................................8-3
8-1-4 Flow of Operation........................................................................................................................8-7
8-2 Analog Output Units.............................................................................................................. 8-15
8-2-1 Overview...................................................................................................................................8-15
8-2-2 Part Names and Functions........................................................................................................8-15
8-2-3 Specifications............................................................................................................................8-16
8-2-4 Flow of Operation......................................................................................................................8-20
8-3 Analog I/O Units........................... ... ... ... ... .... ... ....................................... ... ... ... .... ... ................8-27
8-3-1 CP1W-MAD11 Analog I/O Units...............................................................................................8-27
8-3-2 CP1W-MAD42/CP1W-MAD44 Analog I/O Units.......................................................................8-40
8-4 Temperature Sensor Units.................................................................................................... 8-56
8-4-1 CP1W-TS1/TS2 Temperature Sensor Units.......................................................................8-56
8-4-2 CP1W-TS003 Temperature Sensor Units.................................................................................8-71
8-4-3 TS004 Temperature Sensor Units ............................................................................................8-81
8-5 CompoBus/S I/O Link Units ................................................................................................. 8-92
8-5-1 Overview...................................................................................................................................8-92
8-5-2 Part Names and Functions........................................................................................................8-92
8-5-3 Specifications............................................................................................................................8-94
8-5-4 Flow of Operation......................................................................................................................8-94
Section A Appendices
A-1 Dimensions .............................................................................................................................A-2
A-1-1 CPU Units ...................................................................................................................................A-2
A-1-2 Option Boards........................................................................... ... ...............................................A-5
A-1-3 Expansion I/O Units ....................................................................................................................A-8
A-1-4 Expansion Units.................................... .. ..................................... ... ..........................................A-10
A-2 Wiring Diagrams....................................................................................................................A-12
A-2-1 CPU Units .................................................................................................................................A-12
A-2-2 Expansion I/O Units ..................................................................................................................A-21
A-2-3 Expansion Units.................................... .. ..................................... ... ..........................................A-28
A-2-4 Serial Communications.............................................................................................................A-39
10
CP1E CPU Unit Hardware User’s Manual(W479)
A-3 Wiring for Serial Communications.......................................................................................A-44
A-3-1 Recommended RS-232C Wiring...................................................... ... ... ..................................A-44
A-3-2 Recommended RS-422A/485 Wiring.......................... .................................... ... .......................A-47
A-3-3 Converting the Built-in RS-232C Port to RS-422A/485 ............................................................A-50
A-3-4 Reducing Electrical Noise for External Wiring..........................................................................A-53
Index ..................................................................................................................................Index-1
Revision History................................................................................Revision-1
CP1E CPU Unit Hardware User’s Manual(W479)
11

Terms and Conditions Agreement

Warranty, Limitations of Liability

Warranties

Exclusive Warranty
Omron’s exclusive warranty is that the Products will be free from defects in materials and workman­ship for a period of twelve months from the date of sale by Omro n (or such other period expr essed in writing by Omron). Omron disclaims all other warranties, express or implied.
Limitations
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right.
Buyer Remedy
Omron’s sole obligation hereunder shall be, at Omron’s electi on, to (i) replace (in the form origin ally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-com­plying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inap propriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combi­nation with any electrical or electronic components, circuits, system assemblies or any other materi­als or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CON­SEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
12
CP1E CPU Unit Hardware User’s Manual(W479)

Application Considerations

Suitability of Use
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a com­plete determination of the suitability of the Product in combination with the end product, machine, sys­tem, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take applica­tion responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Programmable Products
Omron Companies shall not be responsible for the use r’s p rog rammin g o f a pr ogra mma ble Pr od uct, o r any consequence thereof.

Disclaimers

Performance Data
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actu al perfor­mance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications
Product specifications and accessories may be changed at any time b ased on improve ments and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product.
Errors and Omissions
Information presented by Omron Companies has been checked and is believed to be accurate; how­ever, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.
CP1E CPU Unit Hardware User’s Manual(W479)
13
WARNING
Caution
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Additionally, there may be severe property damage.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage.
Precautions for Safe Use Indicates precautions on what to do and what not to do to ensure using the product safely.
Precautions for Correct Use Indicates precautions on what to do and what not to do to ensure proper operation and performance.

Safety Precautions

Definition of Precautionary Information

The following notation is used in this manual to provide precautions required to ensure safe usage of a CP-series PLC. The safety precautions that are provided are extremely important to safety. Always read and heed the information provided in all safety precautions.

Symbols

The triangle symbol indicates precautions (including warnings). The specific operation is shown in the triangle and explained in text. This example indicates a precau­tion for electric shock.
The circle and slash symbol indicates operations that you must not do. The specific operation is shown in the circle and explained in text.
The filled circle symbol indicates operations that you must do. The specific operation is shown in the circle and explained in text. This example shows a general precau­tion for something that you must do.
The triangle symbol indicates precautions (including warnings). The specific operation is shown in the triangle and explained in text. This example indicates a general precaution.
The triangle symbol indicates precautions (including warnings). The specific operation is shown in the triangle and explained in text. This example indicates a precau-
14
tion for hot surfaces.
CP1E CPU Unit Hardware User’s Manual(W479)
Do not attempt to take any Unit apart while the power is being supplied.
WARNING
Doing so may result in electric shock.
Do not touch any of the terminals or terminal blocks while the power is being supplied.
Doing so may result in electric shock.
Provide safety measures in external circuits (i.e., not in the Programmable Co n­troller), including the following items, to ensure safety in the system if an abnormality occurs due to malfunction of the PLC or another external factor affecting the PLC operation.
Not doing so may result in serious accidents.
Emergency stop circuits, interlock circuits, limit circuits, and similar safety mea­sures must be provided in external control circuits.
The PLC will turn OFF all outputs when its self-diagnosis function detects any error or when a severe failure alarm (FALS) instruction is executed. Unexpected opera­tion, however, may still occur for errors in the I/O control section, errors in I/O mem­ory, and errors that cannot be detected by the self-diagnosis function. As a countermeasure for all these errors, external safety measures must be provided to ensure safety in the system.
The PLC outputs may remain ON or OFF due to deposition or burning of the outp ut relays or destruction of the output transisto rs. As a coun te rme asu r e for such pro b ­lems, external safety measures must be provided to ensure safety in the system.
When the 24-VDC output (service power supply to the PLC) is overloaded or short­circuited, the voltage may drop and result in the outputs being turned OFF. As a countermeasure for such problems, external safety measures must be provided to ensure safety in the system.
Fail-safe measures must be taken by the customer to ensur e safety in the event of incorrect, missing, or abnormal signals caused by broken signal lines, momentary power interruptions, or other causes.
Serious accidents may result from abnormal operation if proper measures are not provided.
Do not apply the voltage/current outside the specified range to this unit. It may cause a malfunction or fire.
CP1E CPU Unit Hardware User’s Manual(W479)
15
CautionCaution
Be sure to sufficiently confirm the safety at the destination when you transfer the program or I/O memory or perform procedures to change the I/O memory.
Devices connected to PLC outputs may incorrectly operate regardless of the operat­ing mode of the CPU Unit.
With an E(S)-type CPU Unit or with an N/NA(S)-type CPU Unit without a Bat­tery, the contents of the DM Area (D) * , Holding Area (H), the Counter Present Val­ues (C), the status of Counter Completion Flags (C), and the status of bits in the Auxiliary Area (A) related to clock functions may be unstable when the power supply is turned ON.
*This does not apply to areas backed up to EEPROM using the DM backup function. If the DM backup function is being used, be sure to use one of the following methods
for initialization.
1. Clearing All Areas to All Zeros Select the Clear Held Memory (HR/DM/CNT) to Zero Check Box in the Startup
Data Read Area in the PLC Setup.
2. Clearing Specific Areas to All Zeros or Initializing to Specific Values Make the settings from a ladder program.
If the data is not initialized, the unit or device may operate unexpectedly because of unstable data.
Execute online edit only after confirming that no adverse effects will be ca used by extending the cycle time.
Otherwise, the input signals may not be readable.
Tighten the screws on the terminal block of the AC power supply section to the torque specified in the user’s manual.
The loose screws may result in burning or malfunction.
Do not touch the power supply section when power is being supplied or imme­diately after the power supply is turned OFF.
The power supply section and I/O terminal blocks will be hot and you may be burned.
16
CP1E CPU Unit Hardware User’s Manual(W479)
Pay careful attention to the polarities (+/-) when wiring the DC power supply.
Caution
A wrong connection may cause malfunction of the system.
When connecting the PLC to a computer or other peripheral device, either ground the 0-V side of the external power supply or do not ground the external power supply at all.
Otherwise the external power supply may be shorted depending on the connection methods of the peripheral device. DO NOT ground the 24 V-side of the external power supply, as shown in the following diagram.
Non-insulated DC power supply
FG
24V
0V
FG
0V
CPU Unit
USB cable or other communications cable
Peripheral device
FG
(e.g., personal computer)
0V
FG
The DM Area (D), Holding Area (H), Counter Completion Flags (C), and Counter Present Values (C) will be held by the Battery if a Battery is mounted in a CP1E­N/NA (S)D- CPU Unit. When the battery voltage is low, however, I/O mem­ory areas that are held (including the DM, Holding, and Counter Areas) will be unsta­ble. The unit or device may operate unexpectedly because of unstable data.
Use the Battery Error Flag or other measures to stop outpu t s if ex te rnal out ­puts are performed from a ladder program based on the contents of the DM Area or other I/O memory areas.
Sufficiently check safety if I/O bit status or present values are monitored in the Ladder Section Pane or present values are monitored in the Watch Pane.
If bits are set, reset, force-set, or force-reset by inadvertently pressing a shortcut key, devices connected to PLC outputs may operate incorrectly regardless of the operat­ing mode.
Program so that the memory area of the start address is not exceeded when using a word address or symbol for the offset.
For example, write the program so that processing is executed only when the indirect specification does not cause the final address to exceed the memory area by using an input comparison instruction or other instruction. If an indirect specification causes the address to exceed the area of the start address, the system will access data in other area, and unexpected operation may occur.
CP1E CPU Unit Hardware User’s Manual(W479)
17
Caution
Set the temperature range according to the type of temperature sensor con­nected to the Unit.
Temperature data will not be converted correctly if the temperature range does not match the sensor.
Do not set the temperature range to any values other than those for which tem­perature ranges are given in the following table.
An incorrect setting may cause operating errors.
18
CP1E CPU Unit Hardware User’s Manual(W479)

Precautions for Safe Use

Observe the following precautions when using a CP-series PLC.
Power Supply
Always use the power supply voltages specified in the user’s manuals. An incorrect voltage may
result in malfunction or burning.
Take appropriate measures to ensure that the specified power with the rated voltage and fre­quency is supplied. Be particularly careful in places where the power supply is unstable. An incor­rect power supply may result in malfunction.
Double-check all wiring and switch settings before turning ON the power supply. Incorrect wiring may result in burning.
Always turn OFF the power supply to the PLC before attem pting any o f the following. Not turning OFF the power supply may result in malfunction or electric shock.
Mounting or dismounting Expansion Units or Expansion I/O Units
Mounting or dismounting Option Boards
Setting rotary switches
Connecting cables or wiring the system
Connecting or disconnecting the connec to rs
Installation
Before touching a Unit, be sure to first touch a grounded metallic object in order to discharge any
static build-up. Not doing so may result in malfunction or damage.
Install the Unit properly as specified in the operation manual. Improper installation of the Unit may result in malfunction.
Be sure that the terminal blocks, connectors, Option Boards, and other items with locking devices are properly locked into place. Improper locking may result in malfunction.
Wiring
Wire correctly according to specified procedures in this manual.
Keep the wire cuttings out of the Unit when wiring.
Always use the following size wire when connecting I/O terminals: AWG22 to AWG18 (0.32 to
2
0.82 mm
When unpacking the Unit, check carefully for any external scratches or other damages. Also, shake the Unit gently and check for any abnormal sound.
Install external breakers and take other safety measures again st short-circuiting in external wiring . Insufficient safety measures against short-circuiting may result in burning.
Always connect to a ground of 100 Ω or less when installing the Units. Not connecting to a ground of 100 Ω or less may result in electric shock.
Leave the label attached to the top of the Unit when wiring to prevent the entry of foreign matter. Removing the label may result in malfunction if foreign matter enters the Unit.
Keep foreign substances, such as wiring chips, from entering into the Units. It may cause a fire, failure or malfunction. Take protective measures especially at the time of construction.
Remove the label after the complet ion of wiring to ensure proper heat dissipation. Leaving the label attached may result in malfunction.
Use crimp terminals for wiring. Do not connect bare stranded wires directly to terminals. Connec­tion of bare stranded wires may result in burning.
Do not apply voltages to the inp ut term inals in excess o f the r ated inpu t voltag e. Exces s voltag es may result in burning.
).
CP1E CPU Unit Hardware User’s Manual(W479)
19
Do not apply voltages or connect loads to the output terminals in excess of the maximum switch-
ing capacity. Excess voltage or loads may result in burning.
Disconnect the functional grou nd terminal when performing withstan d voltage tests. Not discon­necting the functional ground terminal may result in burning.
Be sure that all the PLC terminal screws and cable connector screws are tightened to the torque specified in the relevant manuals. The tightening torque for the terminals on the CP1W­CIF11/CIF12 terminal block is 0.28 N·m Incorrect tightening torque may result in malfunction.
The following devices can be connected to pin 6 (+5V) on the built-in RS-232C port on the CPU Unit or the RS-232C Option Board (CP1W-CIF01) mounted to the CPU Unit. Do not connect pin 6 to any other device.
RS-422A CJ1W-CIF11 Conversion Adapter
RS-232C / RS-422A NT-AL001 Conversion Adapter
NV3W-M20L Programmable Terminal
Use the cables that are specified in the manual for each device. External devices or the CPU Unit
may be damaged if a commercially available RS-232C computer cable is used.
Do not pull on the cables or bend the cables beyond their natural limit. Doing either of these may break the cables.
Do not place objects on top of the cables or other wiring lines. Doing so may break the cables.
Handling
To initialize the DM Area, back up the initial contents for the DM Area to backup memory using
one of the following methods.
Set the number of words of the DM Area to be backed up starting with D0 in the Number of CH of DM for backup Box in the Startup Data Read Area.
Include programming to back up specified words in the DM Area to built-in EEPROM by turning ON A751.15 (DM Backup Save Start Bit).
Check the ladder program for proper execution before actually running it on the Unit. Not checking the program may result in an unexpected operation.
The ladder program and parameter area data in the CP1E CPU Units ar e backe d up in the bu ilt-in EEPROM backup memory. The BKUP indicator will light on the front of the CPU Unit when the backup operation is in progress. Do not turn OFF the power supply to the CPU Unit when the BKUP indicator is lit. The data will not be backed up if power is turned OFF and a memory error will occur the next time the power supply is turned ON.
With a CP1E CPU Unit, data memory can be backed up to the built-in EEPROM backup memory. The BKUP indicator will light on the front of the CPU Unit when backup is in progress. Do not turn OFF the power supply to the CPU Unit when the BKUP indicator is lit. If the power is turned OFF during a backup, the data will not be backed up and will not be transferred to the DM Area in RAM the next time the power supply is turned ON.
Before replacing the battery, supply powe r to the CPU Unit for at least 30 minutes and then com­plete battery replacement within 5 minutes. Memory data may be corrupted if this precau tion is not observed.
The equipment may operate unexpectedly if inappropriate parameters are set. Even if the appro­priate parameters are set, confirm that equipment will not be adversely affected before transfer­ring the parameters to the CPU Unit.
After replacing the CPU Unit, make sure that the required data for the DM Area, Holding Area, and other memory areas has been transferred to the new CPU Unit before restarting operation.
Do not attempt to disassemble, repair, or modify any Units. Any attempt to do so may result in malfunction, fire, or electric shock.
Do not drop the Unit or subject the Unit to unusual vibration and shock. Do so may result in failure or fire.
Confirm that no adverse effect will occur in the system before attempting any of the following. Not doing so may result in an unexpected operation.
Changing the operating mode of the PLC (including the setting of the startup op erating mode).
20
CP1E CPU Unit Hardware User’s Manual(W479)
Force-setting/force-resetting any bit in memory.
Changing the present value of any word or any set value in memory.
When replacing parts, be sure to confirm that the rating of a n ew part is co rr ect. No t doin g so ma y
result in malfunction or burning.
Do not touch the Expansion I/O Unit Connecting Cable while the power is being supplied in order to prevent malfunction due to static electricity.
Do not turn OFF the power supply to the Unit while data is being transferred.
When transporting or storing Units or Board, static electricity can destroy LSIs or ICs. Cover the
PCBs with a conductive material and maintain the specified storage temperature.
Do not touch circuit boards or the components mounted to them with your bare hands. There are sharp leads and other parts on the boards that may cause injury if handled improperly.
Double-check the pin numbers when assembling and wiring the connectors.
Never short-circuit the positive and negative terminals of a battery or charge, disassemble, heat,
or incinerate the battery. Do not subject the battery to strong shocks or deform the battery by applying pressure. Doing any of these may result in leakage, rupture, heat generation, or ignition of the battery. Dispose of any battery that has been dropped on the floor or otherwise subjected to excessive shock. Batteries that have been subjected to shock may leak if they are used.
Dispose of the product and batteries according to local ordinances as they apply.
UL standards require that only an experienced engineer can replace the battery. Make sure that
an experienced engineer is in charg e of battery replacement. Follow the procedure for battery replacement given in this manual.
The following precaution must be displayed on all products that contain a lithium primary battery (containing at least 6 ppb of perchlorate) and that will be exported to or transported through the State of California in the USA. Perchlorate Material - special handling may apply. See http://www.dtsc.ca.gov/hazardouswaste/perchlorate A CP1W-BAT01 or CJ1W-BAT01 lithium primary battery (containing at least 6 ppb of perchlor ate) can be mounted in a CP1E-N/NAD- CPU Unit. Display the precaution given above on your product’s packaging box or shippi ng box if the product contains a CP1W-BAT01 or CJ1W­BAT01 Battery and is exported to or through the State of California in the USA.
This product is EMC compliant when assembled in a complete PLC system. Refer to the applica­ble manual for grounding, cable selection, and any other conditions for EMC compliance.
This is a Class A product for use in industrial environments. In residential environments it may cause radio interference, in which case the user may be requir ed to take adequate meas ures to reduce interference.
External Circuits
Always configure the external circuits to turn ON power to the PLC before turning ON power to the
control system. If the PLC power supply is turned ON after the control power supply, temporary errors may result in control system signals because the output terminals on DC Output Units and other Units will momentarily turn ON when power is turned ON to the PLC.
Fail-safe measures must be taken by the customer to ensure safety in the event that outputs from output terminals remain ON as a r esult of intern al circuit failures, which can occur in relays, tran­sistors, and other elements.
If the I/O Hold Bit is turned ON, the outputs from the PLC will not be turned OFF and will maintain their previous status when the PLC is switched from RUN or MONITOR mode to PROGRAM mode. Make sure that the external loads will not produce dangerous conditions when this occurs. (When operation stops for a fa tal error, including those produced with the FALS instruction, all outputs from PLC will be turned OFF and only the internal output status in the CPU Unit will be maintained.)
CP1E CPU Unit Hardware User’s Manual(W479)
21

Operating Environment Precautions

Perform installation following the instructions in this manual
Follow the instructions in this manual to correctly perform installation .
Do not operate the control system in the following locations
Locations subject to direct sunlight
Locations subject to temperatures or humidity outside the range specified in the specifications
Locations subject to condensation as the result of severe changes in temperature
Locations subject to corrosive or flammable gases
Locations subject to dust (especially iron dust) or salts
Locations subject to exposure to water, oil, or chemicals
Locations subject to shock or vibration
Locations subject to direct rain fall
Locations subject to direct strong UV
Take countermeasures in the following locations
Locations subject to static electricity or other forms of noise
Locations subject to strong electromagnetic fields
Locations subject to possible exposure to radioactivity
Locations close to power supplies
22
CP1E CPU Unit Hardware User’s Manual(W479)

Regulations and Standards

Conformance to EC Directives

Applicable Directives
EMC Directives
Low Voltage Directive
Concepts
EMC Directives
OMRON devices are electrical components that are designed to be built into equipment and manu­facturing systems. OMRON devices that comply with EMC Directives also conform to the related EMC standards*, so that they can be more easily built into other devices or the overall machine. Whether the products conform to the standards in the system used by the customer, however, must be checked by the customer.
EMC-related performance of the OMRON devices that comply with EC Directives will vary depend­ing on the configuration, wiring, and other conditions of the equipment or control panel on which the OMRON devices are installed. The customer must, therefore, perform the final ch eck to confirm tha t devices and the overall machine conform to EMC standards.
* The applicable EMC (Electromagnetic Compatibility) standard is EN61131-2.
Low Voltage Directive
Always ensure that devices operating at voltages of 50 to 1,000 VAC an d 75 to 1,500 VDC meet the required safety standards for the PLC (EN 61131-2).
Conformance to EC Directives
The CP1E PLCs comply with EC Directives. To ensure that the machine or device in which the CP1E PLC is used complies with EC Directives, the PLC must be installed as follows:
The CP-series PLC must be installed within a control panel.
CP-series PLCs complying with EC Directiv es also conform to EN61131-2. Radiated emission
characteristics (10-m regulations) may vary depending on the configuration of the control panel used, other devices connected to the control panel, wiring, and other conditions. You must there­fore confirm that the overall machine or equipment complies with EC Directives.
A SYSMAC CP-series PLC is a class A product (for an industrial environment). In residential areas it may cause radio interference, in which case the user may be required to take adequate measures to reduce interference.

Trademarks

SYSMAC is a registered trademark for Programmable Controllers made by OMRON Corporation. CX-One is a registered trademark for Programming Software made by OMRON Corporation. Windows is a registered trademark of Microsoft Corporation. Other system names and product names in this document are the trademarks or reg iste re d trad ema rks
of their respective companies.
CP1E CPU Unit Hardware User’s Manual(W479)
23

Related Manuals

The following manuals are related to the CP1E. Use them together with this manual.
Manual name Cat. No. Model numbers Application Contents
SYSMAC CP Series CP1E CPU Unit Hard­ware User’s Manual (this manual)
SYSMAC CP Series CP1E CPU Unit Soft­ware User’s Manual
SYSMAC CP Series CP1E CPU Unit Instruc­tions Reference Manual
CS/CJ/CP/NSJ Series Communications Com­mands Reference Man­ual
SYSMAC CP Series CP1L/CP1E CPU Unit Introduction Manual
CX-Simulator Operation Manual
W479 CP1E-ESD-
W480 CP1E-ESD-
W483 CP1E-ESD-
W342 CS1G/H-CPUH
W461 CP1L-L10D-
W366
CP1E-NSD- CP1E-ED- CP1E-ND- CP1E-NAD-
CP1E-NSD- CP1E-ED- CP1E-ND- CP1E-NAD-
CP1E-NSD- CP1E-ED- CP1E-ND- CP1E-NAD-
CS1G/H-CPU-V1 CS1D-CPUH CS1D-CPUS CS1W-SCU-V1 CS1W-SCB-V1 CJ1G/H-CPUH CJ1G-CPUP CJ1M-CPU CJ1G-CPU CJ1W-SCU-V1
CP1L-L14D- CP1L-L20D- CP1L-M30D- CP1L-M40D- CP1L-M60D- CP1E-ED- CP1E-ND- CP1E-NAD-
CXONE-ALC-V4/ ALD-V4
To learn the hard­ware specifications of the CP1E PLCs
Use this manual together with the CP1E CPU Unit Software User’s Manual (Cat. No. W480) and Instructions Reference Manual (Cat. No. W483).
To learn the soft­ware specifications of the CP1E PLCs
Use this manual together with the CP1E CPU Unit Hardware User’s Manual (Cat. No. W479) and Instructions Reference Manual (Cat. No. W483).
To learn program­ming instructions in de
tail
To learn communi­cations commands for CS/CJ/CP/NSJ­series Controllers in detail
Note This manual describes commands addressed to CPU Units. It
does not cover commands addressed to other Units or ports (e.g., serial communications ports on CPU Units, communicati ons por ts on Serial Communications Units/Boards, and other Communica­tions Units).
To learn the basic setup methods of the CP1L/CP1E PLCs
Operating procedures for CX-Simulator Simulation Support Software for Windows computersUsing simulation in the CX-Programmer with CX-Programmer
Describes the following information for CP1E PLCs.
Overview and features
Basic system configuration
Part names and functions
Installation and settings
Troubleshooting
Describes the following information for CP1E PLCs.
CPU Unit operation
Internal memory
Programming
Settings
CPU Unit built-in functions
Interrupts
High-speed counter inputs
Pulse output s
Serial communications
Analog I/O function
Other functions
Describe
s each programming instruction in
detail. When programming, use this manual together
with the CP1E CPU Unit Software User’s Man­ual (Cat. No. W480).
Describes
1) C-mode commands and
2) FINS commands in detail. Read this manual for details on C-mode and
FINS commands addressed to CPU Units.
Describes the following information for CP1L/CP1E PLCs.
Basic configuration and component names
Mounting and wiring
ogramming, data transfer, and debugging
Pr using the
Application program examples
Describes the operating procedures for the CX-Simulator.
CX-Programmer
24
CP1E CPU Unit Hardware User’s Manual(W479)
\
Overview and Specifications
This section gives an overview of the CP1E, de scribes its features, and provides its specifications.
1-1 CP1E Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1-1-1 Overview of Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1-1-2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1-2 Basic Operating Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
1-3 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
1-3-1 General Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
1-3-2 Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
1-3-3 Functional Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
1-4 Difference between E/N/NA-type and E/NS(1)-type. . . . . . . . . . . . 1-14
1
CP1E CPU Unit Hardware User’s Manual(W479)
1-1
1 Overview and Specifications

1-1 CP1E Overview

1-1-1 Overview of Features

The SYSMAC CP1E Programmable Controller is a package-type PLC made by OMRON that is designed for easy application. The CP1E includes E(S)-type CPU Units (basic models) for standard control operations using basic, movement, arithmetic, and comparison instructions, and N/NA(S)-type CPU Units (application models) that supports connections to Programmable Terminals, Inverters, and Servo Drives.
Basic Models CP1E Application Models
E(S)-type CPU Units N(S)-type CPU Units
CPU with 10, 14 or 20 I/O Points
Appearance E-type
CPU Unit with 30, 40 or
60 I/O Points
E-type
CPU with 14 or
20 I/O Points
N-type N/NA-type
CPU Unit with
30, 40 or 60 I/O
Points
NA-type
CPU Units
CPU Unit with
20 I/O Points
ES-type
I/O points E 10/14/20/30/40
ES 14/20/30/40/60
Program capacity 2K steps 8K steps DM Area capacity 2K words
Of these 1,500 words can be written to the built-in EEPROM.
Mounting Expan­sion I/O Units and Expansion Units
Model with transis­tor outputs Pulse outputs Not supported. Supported (Model with transistor outputs only) Built-in serial com­munications port Built-in analog Not available. Not available. Available Option Board Not supported. Not supported. N/NA-type: Supported (for one
Connection port for Programming Device
Clock Not provided. Provided Using a Battery Cannot be used. Can be used (sold separately). Backup time of built-in capacitor Battery-free opera-
tion
Not possible. 3 Units maximum Not possible. 3 Units maximum
Available (CPU Unit with 10 I/O points only) Available
Not provided. RS-232C port provided
USB port USB port
50 hours at 25°C 40 hours at 25°C
Always battery-free operation. Only data in the built-in EEPROM will be retained if power is interrupted for longer than 50 hours.
ES-type
N 14/20/30/40/60 NS(1) 30/40/60
8K words Of these 7,000 words can be written to the built-in EEPROM.
RS-485 port provided (NS1-typ e on l y)
Battery-free operation if no battery is attached. Only data in the built-in EEPROM will be retained if power is interrupted for longer than 40 hours.
NS(1)-type
20
port) NS(1)-type: Not Supported
1-2
CP1E CPU Unit Hardware User’s Manual(W479)
Loading...
+ 296 hidden pages