Omron CompAIR C801KD for children Manual

0 (0)

TM

Compressor Nebulizer

Model NE-C801KD

Instruction Manual

Mode d’emploi

Gebrauchsanweisung

Manuale di istruzioni

Manual de instrucciones

Gebruiksaanwijzing

EN

FR

DE

IT

ES

NL

RU

AR

IM-NE-C801S-KDE(V)-02-06/2014 1887051-1B

QUICK MANUAL

Please read entire manual before using the device.

Warning:

Clean and disinfect all the parts before using them.

page 16-17

1. Adding medication

 

Rotate the inhalation top anti-clockwise

 

to remove.

 

Add the appropriate amount of

 

prescribed medication.

 

Make sure the vaporizer head is

 

securely attached to the inhalation top.

Clicks

Put the inhalation top back and rotate it

 

clockwise until they click in place.

 

page 12

Clicks

2. Assembling kids accessory and mask

Assemble the nebulizer kit as the following order.

[1] Cap

[2] Kids accessory

[3] Mask

page 13

Warning:

Do not let infants and children play with a kids accessory. Kids accessory is not a toy, but a component of nebulizer kit.

Omron CompAIR C801KD for children Manual

3. Connecting AC adapter

Power Plug

Power Connector

Insert the power plug of AC adapter into the power connector of the main unit.

4. Attaching air tube

Power Outlet

Plug the AC adapter into the power outlet.

page 11

Attach the air tube to the main unit and to the nebulizer kit.

When do so, twist and push it firmly. page 13

5. Applying mask and starting inhalation

Apply the mask securely.

Turn on the power to the main unit. page 14

Use the nebulizer kit holder to place the nebulizer kit

page 15

Contents

Before using the device

 

Introduction .................................................................................................................

4

Intended use................................................................................................................

5

Important safety instructions.....................................................................................

6

1.

Know your unit........................................................................................

9

Operating instructions

11

2.

Preparing the nebulizer for use ...........................................................

 

2.1

Connecting AC adapter ..................................................................................

11

 

2.2

Adding medication and assembling the parts .................................................

12

3.

Taking medication ................................................................................

14

Care and maintenance

16

4.

Cleaning and disinfecting ....................................................................

 

4.1

Cleaning..........................................................................................................

16

 

4.2

Disinfecting .....................................................................................................

16

5.

Maintenance and storage.....................................................................

18

6.

Changing the air filter...........................................................................

19

7.

Troubleshooting....................................................................................

20

8.

Technical data .......................................................................................

21

9.

Accessories and replacement parts ...................................................

24

Introduction

Thank you for purchasing the OMRON COMP AIR.

This product was developed in conjunction with respiratory therapists for the successful treatment of asthma, chronic bronchitis, allergies and other respiratory disorders. The compressor forces air to the nebulizer kit. When the air enters the nebulizer kit, it converts the prescribed medication into an aerosol of microscopic droplets that can easily be inhaled.

This is a medical device. Operate the device only as instructed by your doctor and/or respiratory therapist.

NE-C801KD includes the kids accessories to enable children to feel more comfortable while inhaling. It improves compliance with drug treatment.

How the nebulizer kit works

The medication that is pumped up through the medication channel is mixed with compressed air which is generated by a compressor pump. The compressed air mixed with medication is turned into fine particles and sprayed by being impacted to the baffle.

Baffle

Aerosol Aerosol

Medication

NozzleChannel

Medication Medication

Compressed Air

4

Intended use

Medical Purpose

This product is intended to be used for inhaling medication for

 

respiratory disorders.

 

Intended User

• Legally certified medical experts, such as doctor, nurse and

 

therapist.

 

 

• Caregiver or patient under the guidance of qualified medical

 

experts for home treatment.

 

 

• The user should also be capable of understanding general

 

operation of NE-C801KD and the content of instruction manual.

Intended Patients

This product should not be used on patients, who are unconscious

 

or are not breathing spontaneously.

 

Environment

This product is intended for use in a medical facility, such as

 

Hospital, clinic and doctor’s office, and in a room of general

 

household.

 

Durable period

Durable periods are as follows, provided the product is used to

 

nebulize 2 ml of medication 2 times a day for 6 minutes each time

 

at room temperature (23°C).

 

 

Durable period may vary depending on usage environment.

 

Compressor (Main unit)

5 years

 

Nebulizer Kit

1 year

 

(Cap, Inhalation Top,

 

 

Vaporizer Head, Medication Tank)

 

 

Kids Accessory

1 year

 

Mouthpiece

1 year

 

Air Tube (PVC, 100cm)/(Silicone, 100cm)

1 year

 

Air Filter

60 days

 

Mask (PVC)/(SEBS)

1 year

Precautions for use

Warnings and cautions described in the instruction manual should

 

be observed.

 

EN

5

Important safety instructions

Read all the information in the instruction manual and any other literature included in the box before using the device.

When using an electrical product, especially when children are present, basic safety precautions should always be followed including the following:

Warning:

Indicates a potentially hazardous situation which, if not avoided, could result in serious injury.

(Usage)

For type, dose, and regime of medication follow the instructions of your doctor or respiratory therapist.

If you feel anything unusual during use, stop using the device immediately and consult your doctor.

Do not use only water in the nebulizer, for inhaling purposes.

Keep the device and kids accessory out of the reach of unsupervised infants and children. The device may contain small pieces that can be swallowed.

Do not let infants and children play with a kids accessory. Kids accessory is not a toy, but a component of nebulizer kit.

Do not store the air tube while there is moisture or medication remaining inside it.

Do not use or store the device where it may be exposed to noxious fumes or volatile substances.

Do not use the device where it may be exposed to flammable gas.

Do not cover the compressor with a blanket, towel, or any other type of cover during use.

Make sure that the nebulizer kit and kids accessory are clean before use.

Always dispose of any remaining medication after use, and use fresh medication each time.

Do not use in anaesthetic or ventilator breathing circuits.

Store the parts in a clean location for avoiding infection.

(Risk of electrical shock)

Do not use the compressor or AC adapter while they are wet, or connect them to a power outlet or other devices with wet hands.

The compressor and AC adapter are not waterproof. Do not spill water, or other liquids, on these parts. If liquid does spill on these parts, immediately unplug the power cord and wipe off the liquid with gauze or other absorbent material.

Do not immerse the compressor in water or other liquid.

Do not use or store the device in humid locations, such as a bathroom.

Use only original OMRON AC adapter. Use of unsupported AC adapter may damage the device.

Do not operate the device with a damaged power cord or plug.

Keep the power cord away from heated surfaces.

Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” (page 23) in the Technical Data Section.

6

(Cleaning and disinfecting)

Observe the rules below when cleaning or disinfecting parts. Failure to observe these rules may result in damage, inefficient nebulization or infection. For the instructions, refer to

“4. Cleaning and disinfecting” section.

Clean and disinfect the nebulizer kit, kids accessory, mask, mouthpiece or nosepiece before using them when as follows:

-the first time after purchase.

-if the device has not been used for a long period of time

-if more than one person uses the same device

Be sure to wash or wipe the parts after use, and ensure that they are thoroughly disinfected and dried, and stored in a clean location.

Do not leave the cleaning solution in the parts.

Caution:

Indicates a potentially hazardous situation which if not avoided, may result in minor or moderate injury, or physical damage.

(Usage)

Provide close supervision when this device is used by, on, or near children or invalids.

Make sure that the parts are attached correctly.

Make sure that the vaporizer head is correctly installed before use.

Make sure that the air filter is correctly attached.

Make sure that the air filter is clean. If the air filter has been used for more than 60 days, replace it with a new one.

Do not spill liquid or medication on the compressor.

Do not tilt the nebulizer kit so that it is at an angle of greater than 45° in all directions, or shake it while in use.

Do not use or store the device while the air tube is creased.

Use only original nebulizing parts, air tube, air filter and air filter cover.

Do not add more than 7 ml of medication to the medication tank.

Do not carry or leave the nebulizer kit while the medication tank contains medication.

Do not leave the device unattended with infants or persons who cannot express their consent.

Do not subject the device or the parts to any strong shocks such as dropping the device on the floor.

• Do not distort the vaporizer head, or jab the nozzle of the medication tank with a pin or any EN sharp object.

Do not insert fingers or objects inside the compressor.

Do not disassemble or attempt to repair the compressor or power cord.

Do not leave the device or its parts where it will be exposed to extreme temperatures or changes in humidity, such as in a vehicle during the summer, or where it will be exposed to direct sunlight.

Do not block the air filter cover.

Do not use the device while sleeping or if drowsy.

Do not block the slit between the cap and the inhalation air inlet.

Approved for human use only.

If the device is used continuously, the service life of the device may be shortened.

Limit use to 20 minutes at a time, and allow a 40 minute interval before using the device again.

When using the device, the main unit may become hot.

7

Do not touch the main unit for other than necessary operation such as turning off the power while nebulizing.

To avoid the medication residue on the face, be sure to wipe the face after removing the Mask.

(Risk of electrical shock)

Always unplug the AC adapter from the power outlet after use and before cleaning.

Plug the device into the appropriate voltage outlet. Do not overload power outlets or use extension cords.

Always remove the AC adapter from the device after use and before cleaning.

Do not misuse the cord of the AC adapter.

Do not wind the cord of the AC adapter around the compressor or AC adapter.

Changes or modifications not approved by OMRON HEALTHCARE will void the user warranty.

Do not pull the power cord of AC adapter strongly.

(Cleaning and disinfecting)

Observe the rules below when cleaning or disinfecting parts. Failure to observe these rules may result in damage, inefficient nebulization or infection. For the instructions, refer to

“4. Cleaning and disinfecting” section.

Do not use a microwave oven, dish dryer or hair dryer to dry the device or the parts.

Do not use an autoclave, EOG gas sterilizer or low temperature plasma sterilizer.

When disinfecting parts by boiling, make sure that the container does not boil dry. Otherwise it may also result in fire.

General Safety Precautions:

Inspect the device and parts before using them each time, and check that there are no problems. In particular, be sure to check the following:

-That the vaporizer head, nozzle, kids accessory or air tube are not damaged.

-That the nozzle is not blocked.

-That the compressor operates normally.

When using this device, there will be some noise and vibration caused by the pump in the compressor. There will also be some noise caused by the emission of compressed air from the nebulizer kit. This is normal and does not indicate a malfunction.

Operate the device only as intended. Do not use the device for any other purpose.

Do not use the device at temperatures greater than +40°C.

Make sure that the air tube is securely attached to the compressor and nebulizer kit, and does not come loose. Twist the air tube plug slightly when inserting it into the air tube connectors to avoid the air tube disconnecting during use.

The AC adapter is provided so that the device can be completely isolated from the power source. To completely isolate the device from the power source unplug the plug from the power source.

Read and follow the “Correct Disposal of This Product” in the Technical Data Section (page 23) when disposing of the device and any used accessories or optional parts.

Save these instructions for future reference.

8

1. Know your unit

Nebulizer Kit

Compressor (Main Unit)

Nebulizer Kit Holder

Air Tube Plug

Air Tube Connector

Air Tube Plug

Power Switch

Rear View

Air Tube

Air Filter Cover

Power

*Air filter inside

Connector

Nebulizer Kit

Cap

Kids Accessory

Kids Accessory

 

(Smile Bear)

(Happy Bunny)

Inhalation Air Inlet

 

 

Inhalation Top

 

 

Vaporizer Head

 

 

Nozzle

 

 

Medication Tank

 

 

Air Tube Connector

 

 

EN

9

Loading...
+ 18 hidden pages