IEC ContaCtors and
ovErload rElays
XTCE018C10A
XTCE/XTOB
IEC EN
60947
All models
shown smaller
than actual size.
l Modular Design
l Compact Frame
l Easy to Install
XTCEXFAC02-5PK
XT Series includes non-reversing contactors,
overload relays and a variety of related
accessories. Because XT meets IEC, UL, CSA,
CCC and CE standards, it is the perfect product
solution for IEC applications all over the world.
The compact, space saving, and easy to install
XT line of IEC contactors and overload relays is
the efficient and effective solution for customer
applications up to 32 A.
XTOB024CC1
XCTE SPECIFICATIONS
FULL VOLTAGE NON-REVERSING 3-POLE CONTACTORS, SCREW TERMINALS, FRAME B AND FRAME C
Ie (A) Ie = Ith
(A) RATINGS AC-3 MOTOR RATING, UL/CSA
AC-3 AC-1
MODEL NO.
220/ 380/ 690V
FRAME B 230V 400V 415V 660/ 115V 200V 230V 200V 230V 460V 575V
XTCE007B10 7 20 2.2 3 4 3.5
XTCE009B10 9 20 2.5 4 5.5 4.5
XTCE009B01 9 20 2.5 4 5.5 4.5
XTCE012B10 12 20 3.5 5.5 7 6.5 1 2 2 3 3 10 10 1 NO
FRAME C
XTCE018C10 18 35 5 7.5 10 11 2 2 3 5 5 10 15 1 NO
XTCE025C10 25 40 7.5 11 14.5 14 2 3 5 7.5 7.5 15 20 1 NO
XTCE032C10 32 40 10 15 18 17 3 5 5 10 10 20 25 1 NO
Notes: 1. The Contactors have positively driven contacts between the integrated auxiliary contact and the auxiliary contactmodule as well
as within the auxiliary contact modules. 2. DC operated contactors have a built-in suppressor circuit.
(60°C)
MAXIMUM KW MAXIMUM 3-PHASE
3-PHASE 1-PHASE HP 3-PHASE HP
MOTORS 50 – 60 HZ RATINGS RATINGS
1
⁄4 3⁄4 1 1.5 2 3 5 1 NO
1
⁄2 1 1.5 3 3 5 7.5 1 NO
1
⁄2 1 1.5 3 3 5 7.5 1 NC
AUX.
CONTACTS
1
CONTRACTORS SPECIFICATIONS
FRAME B FRAME C
MODELS
Standards IEC/EN 60947, VDE 0660, UL, CSA, CCC, RoHS
Weights in kg (lb)
AC Operated 0.23 (0.51) 0.42 (0.93)
DC Operated 0.28 (0.62) 0.48 (1.06)
Mechanical Life 10,000,000
Mechanical Operating Frequency
(ops/hr) AC or DC Operated 9000 5000
Electrical Operating Frequency (ops/hr)
AC-1: 400V I
AC-3: 400V I
AC-4: 400V I
Climatic Proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30
Insulation Voltage (U
Impulse Withstand Voltage (Uimp) Vac 8000
Operational Voltage (U
Safe Isolation to VDE 0106
Part 101 and Part 101/A1
Between Coil and Contacts (Vac) 400 440
Between Contacts (Vac) 400 238 440
Making Capacity Up to 690V (Amps) 112 112 144 440
Breaking Capacity (Amps)
220/230V 70 90 120 170 250 320
380/400V 70 90 120 170 250 320
500V 50 70 100 170 250 320
660/690V 40 50 70 120 150 80
Short-Circuit Protection Rating Maximum Fuse
400V: gG/gL 500V 20 25 35 63
690V: gG/gL 690V 16 20 25 35 35
Type 1 Coordination
400V: gG/gL 500V 35 63 100 125
690V: gG/gL 690V 20 50 50 63
Degree of Protection IP20
Protection Against Direct Contact when
Actuated from Front (IEC 536) Finger- and back-of-hand proof
Terminal Capacity Main Cable—
Screw Terminals Solid (mm
Flexible with Ferrule (mm
Solid or Stranded (AWG) 18 to 14 18 to 6
Terminal Capacity Control Circuit Cable—
Screw Terminals Solid (mm2) 1 x (0.75 to 4),2 x (0.75 to 2.5) 1 x (0.75 to 4), 2 x (0.75 to 4)
Flexible with Ferrule (mm
Solid or Stranded (AWG) 18 to 14
Main Cable & Control Circuit Cable
Connection Screw/Bolt
Tightening Torque Nm Lb-in 1.2 (10.6) 3 (26.6)
Tools
Main & Control Circuit Cable
(Screw Terminals)
Pozidriv Screwdriver 0.8 x 5.5
Standard Screwdriver 1 x 6
Ambient Temperature
Open -25 to 60°C (-13 to 140°F)
Enclosed -25 to 40°C (-13 to 104°F)
Ambient Storage Temperature -40 to 80°C (-40 to 176°F)
XTCE007B XTCE009B XTCE012B XTCF020B XTCE018C XTCE025C XTCE032C
800 800
e
1000 800
e
300 300
e
) Vac 690
i
) Vac 690
e
Type 2 Coordination
2
) 1 x (0.75 to 4),2 x (0.75 to 2.5) 1 x (0.75 to 16),2 x (0.75 to 10)
2
) 1 x (0.75 to 2.5),1 x (0.75 to 2.5) 1 x (0.75 to 16),2 x (0.75 to 10)
2
) 1 x (0.75 to 2.5), 2 x (0.75 to 2.5)
M3.5 M5
Size 2
2