l Modular Design
l Compact Frame
l Easy to Install
XTCEXFAC02-5PK
XT Series includes non-reversing contactors,
overload relays and a variety of related
accessories. Because XT meets IEC, UL, CSA,
CCC and CE standards, it is the perfect product
solution for IEC applications all over the world.
The compact, space saving, and easy to install
XT line of IEC contactors and overload relays is
the efficient and effective solution for customer
applications up to 32 A.
XTOB024CC1
XCTE SPECIFICATIONS
FULL VOLTAGE NON-REVERSING 3-POLE CONTACTORS, SCREW TERMINALS, FRAME B AND FRAME C
Notes: 1. The Contactors have positively driven contacts between the integrated auxiliary contact and the auxiliary contactmodule as well
as within the auxiliary contact modules. 2. DC operated contactors have a built-in suppressor circuit.
(60°C)
MAXIMUM KW MAXIMUM 3-PHASE
3-PHASE 1-PHASE HP 3-PHASE HP
MOTORS 50 – 60 HZ RATINGS RATINGS
AC Operated0.23 (0.51) 0.42 (0.93)
DC Operated0.28 (0.62) 0.48 (1.06)
Mechanical Life10,000,000
Mechanical Operating Frequency
(ops/hr) AC or DC Operated9000 5000Electrical Operating Frequency (ops/hr)AC-1: 400V IAC-3: 400V IAC-4: 400V IClimatic ProofingDamp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30
Insulation Voltage (UImpulse Withstand Voltage (Uimp) Vac 8000
Operational Voltage (U
Safe Isolation to VDE 0106
Part 101 and Part 101/A1
Between Coil and Contacts (Vac)400 440
Between Contacts (Vac) 400 238 440
Making Capacity Up to 690V (Amps) 112 112 144 440
Breaking Capacity (Amps)220/230V 70 90 120 170 250 320
380/400V 70 90 120 170 250 320
Safe isolation to VDE 0106 Part 101
and Part 101(A) in Vac
Between Coil and Auxiliary Contacts400 400
Between the Auxiliary Contacts400 400
Rated Operational Current, le— —
AC-15— —
230V6 A 6 A
380/415V 4 A 3 A
500V 1.5 A —
DC-3 L/R 5 mS 24V 10 A 10 A
60V 6 A 6 A
110V 3 A 3 A
220V 1 A 1 A
Conventional Thermal Current, IControl Circuit Reliability (at U
17V, I
= 5.4 mA)
min
= 24 Vdc, U
e
Component Lifespan, Operations x 106 at Ue = 230V,
AC-15, 3 A
Short-Circuit Rating Without Welding
Maximum Fuse, gG/gL
) Vac 6000 —
imp
16 A 16 A
th
=
min
-8
<10
, < one failure at 100 million operations
1.3 1.3
10 A 10 A
MINI OVERLOAD SPECIFICATIONS
TYPE 1 TYPE 2
COORD- COORD OVERLOAD TRIP CONTACT INATION, INATION, CIRCUIT CEC/NEC
MODEL NO. RELEASE Ir CLASS CONFIG. GG/GL GG/GL BREAKER FUSE
XTOB001BC10.6-1 A 25 4 25 3
XTOB1P6BC1 1-1.6 A 25 6 25 6
XTOB2P4BC1 1.6-2.4 A 25 10 25 6
XTOB004BC12.4-4 A 25 16 25 15
XTOB006BC14-6 A 25 20 25 20
XTOB010BC16-10 A 50 25 25 35
10 A
1 NO-
1 NC
XTOB012BC19-12 A 50 25 25 45
XTOB016CC110-16 A 63 35 30 25
XTOB024CC116-24 A 100 35 30 25
XTOB032CC124-32 A 125 63 30 25
Note 1: Short-circuit protection: Observe the maximum permissible fuse of the contactor with direct device mounting.
SHORT CIRCUIT PROTECTION (A)
3
18
(0.71)
45
(1.77)
68
(2.68)
45 (1.77)
36 (1.42)
8.7
(0.34)
Typ.
5.1 (0.20)
6.5 (0.26)
75 (2.95)
C
3.2 (0.13)
Auxiliary
Type
XTCEXFAC_
XTCEXFCC_
XTCEXFATC_
C
117 (4.61)
117 (4.61)
125 (4.92)
35 (1.38)
4 x M4 Dia.
60 (2.36)
XTCE007B
to
XTCE012B
To OrderVisit omega.com/xtce_xtob for Pricing and Details
IEC OPEN TYPE CONTACTORS 3P FVNR
MODEL NO. DESCRIPTION
XTCE007B10A Contactor 3P FVNR 7 A Frame B 1NO 110/50 120/60 AC Coil
XTCE007B10T Contactor 3P FVNR 7 A Frame B 1NO 24/50 24/60 AC Coil
XTCE007B10TD Contactor 3P FVNR 7 A Frame B 1NO 24 Vdc Coil
XTCE009B10A Contactor 3P FVNR 9 A Frame B 1NO 110/50 120/60 AC Coil
XTCE009B10T Contactor 3P FVNR 9 A Frame B 1NO 24/50 24/60 AC Coil
XTCE009B10TD Contactor 3P FVNR 9 A Frame B 1NO 24 Vdc Coil
XTCE012B10A Contactor 3P FVNR 12 A Frame B 1NO 110/50 120/60 AC Coil
XTCE012B10T Contactor 3P FVNR 12 A Frame B 1NO 24/50 24/60 AC Coil
XTCE012B10TD Contactor 3P FVNR 12 A Frame B 1NO 24 Vdc Coil
XTCE018C10A Contactor 3P FVNR 18 A Frame C 1NO 110/50 120/60 AC Coil
XTCE018C10T Contactor 3P FVNR 18 A Frame C 1NO 24/50 24/60 AC Coil
XTCE018C10TD Contactor 3P FVNR 18 A Frame C 1NO 24-27 Vdc Coil
XTCE025C10A Contactor 3P FVNR 25 A Frame C 1NO 110/50 120/60 AC Coil
XTCE025C10T Contactor 3P FVNR 25 A Frame C 1NO 24/50 24/60 AC Coil
XTCE025C10TD Contactor 3P FVNR 25 A Frame C 1NO 24-27 Vdc Coil
XTCE032C10A Contactor 3P FVNR 32 A Frame C 1NO 110/50 120/60 AC Coil
XTCE032C10T Contactor 3P FVNR 32 A Frame C 1NO 24/50 24/60 AC Coil
XTCE032C10TD Contactor 3P FVNR 32 A Frame C 1NO 24-27 Vdc Coil
Dimensions: mm (inch)
ACCESSORIES
AUXILIARY CONTACTS
MODEL NO. DESCRIPTION
XTCEXFAC02-5PK 5 pack of front mounted snap-on auxiliary contacts Seq A Frame B-C 2NC
XTCEXFAC11-5PK 5 pack of front mounted snap-on auxiliary contacts Seq A Frame B-C 1NO 1NC
XTCEXFAC20-5PK 5 pack of front mounted snap-on auxiliary contacts Seq A Frame B-C 2NO
XTCEXMLB Contactor accessory mechanical interlock Frame B
XTCEXMLC Contactor accessory mechanical interlock Frame C
IEC OVERLOAD RELAYS
MODEL NO. DESCRIPTION
XTOB001BC1 IEC OVLR Frame B, Class 10 0.6-1 A
XTOB1P6BC1 IEC OVLR Frame B, Class 10 1-1.6 A
XTOB2P4BC1 IEC OVLR Frame B, Class 10 1.6-2.4 A
XTOB004BC1 IEC OVLR Frame B, Class 10 2.4-4 A
XTOB006BC1 IEC OVLR Frame B, Class 10 4-6 A
XTOB010BC1 IEC OVLR Frame B, Class 10 6-10 A
XTOB012BC1 IEC OVLR Frame B, Class 10 9-12 A
XTOB016CC1 IEC OVLR Frame C, Class 10 10-16 A
XTOB024CC1 IEC OVLR Frame C, Class 10 16-24 A
XTOB032CC1 IEC OVLR Frame C, Class 10 24-32 A
Comes with complete operator’s manuals.
Ordering Example:XTCE007B10A, Contactor, XTCEXFAC11-5PK, auxiliary contacts, XTOB010BC1, Overload Relay, 2.4 to 4 A.
4
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.