Omega Products XCIB-E-1-1-10 User Manual

High-Temperature Inconel® Overbraided Silica Fiber Insulated Thermocouples
4.8 mm
3
(
16
")
Probe
Style
1
Shown larger
than actual size
Probe
Style
2
4.8 mm
3
(
16
")
Probe
Style
3
6.4 mm
1
(
4
")
9.5 mm
(
25 mm
(1")
29 mm
(1
3
8")
1
8
")
32 mm
(1
1
4
")
64 mm
(2
1
2
")
4.0 mm
5
(
32
")
ID
1.6 mm
1
(
16
Thick
")
Probe
Style
4
64 mm
(2
1
2
")
Probe
Style
5
Specifications
Wire Gage: 20 gage solid
standard limits of error Insulation: Silica or ceramic (Nextel®) fiber Overbraiding and Fittings: Inconel 600® Temperature: 980°C (1800°F) continuous, 1038°C (1990°F) short-term service, depending on thermocouple type Termination: Ceramic beaded leads with compensated spade lugs, OMEGA® OSTW 220°C (425°F) male connector, or OMEGA® NHXH high-temperature 650°C (1200°F) ceramic male connector
U High-Temperature
Insulation with Inconel Overbraid
U Flexible, Abrasion
Resistant
U Withstand Temperatures
up to 1038°C (1990°F)
U Unexcelled Oven and
Furnace Profiling
U 5 Convenient Styles for
Easy Application
U J, K, E, or N Thermocouple
Calibrations
8 mm
5
(
16
")
4.8 mm
3
(
16
")
ID
XCIB Series
Custom Length
and Sizes
Available
Unique OMEGA family of high-temperature Types J, K, E, or N thermocouples are double­protected with abrasion-resistant
Inconel® overbraid with high­temperature fiber insulation. A temperature rating of up to 980°C (1800°F) continuous service and 1038°C (1990°F) short-term service makes these products ideal for many high-temperature measurement applications. They are unexcelled for profiling ovens and furnaces. The 20-gage solid conductor thermocouple wires are insulated with braided ceramic fiber. Over the ceramic fiber is a rugged overbraid of Inconel 600—a tough, high-temperature, high nickel­content alloy.Five convenient styles are available in 1 and 3 m (3 and 10') lengths for high-temperature measurement applications.
A-35
Style 1
5
8"
3
8"
Style 1 is a grounded junction thermocouple with the Inconel overbraid welded to form a smooth rounded tip for all general purpose applications.
Style 2
Style 2 is a general purpose, bead welded, exposed junction thermocouple.
Style 3
Style 3 is an exposed, bead welded junction thermocouple with an Inconel collar to clamp the probe to a surface, or to secure it into a hole or any fabrication.
Style 4
Style 4 is grounded. It can be bolted to a surface, or the Inconel eye can hook the thermocouple to a conveyor flight. Ungrounded units and special hole sites are available. Contact Sales department for more information.
Style 5
Style 5 has an Inconel air hood to protect the exposed beaded wire junction. This design can
XCIB-4, Shown,
Attaches Easily
for Accurate,
High-Temperature
Measurement
be clamped to a surface, hooked to a conveyor flight, or bolted to a surface by using the through hole at the open end of the hood.
To Order Visit omega.com/xcib for Pricing and Details
Termination Termination
Model No. Probe Style Type Model No. Probe Style Type
XCIB-(*)-1-1-(**) 1 XCIB-(*)-4-1-(**) 1 XCIB-(*)-1-2-(**) 2 XCIB-(*)-4-2-(**) 2 XCIB-(*)-1-3-(**) 3 XCIB-(*)-4-3-(**) 3 XCIB-(*)-1-4-(**) 1 4 XCIB-(*)-4-4-(**) 4 4 XCIB-(*)-1-5-(**) 5 XCIB--(*)-4-5-(**) 5 XCIB-(*)-1-6-(**) 6 XCIB--(*)-4-6-(**) 6 XCIB-(*)-1-7-(**) 7 XCIB--(*)-4-7-(**) 7 XCIB-(*)-2-1-(**) 1 XCIB-(*)-5-1-(**) 1 XCIB-(*)-2-2-(**) 2 XCIB-(*)-5-2-(**) 2 XCIB-(*)-2-3-(**) 3 XCIB-(*)-5-3-(**) 3 XCIB-(*)-2-4-(**) 2 4 XCIB-(*)-5-4-(**) 5 4 XCIB-(*)-2-5-(**) 5 XCIB-(*)-5-5-(**) 5 XCIB-(*)-2-6-(**) 6 XCIB-(*)-5-6-(**) 6 XCIB-(*)-2-7-(**) 7 XCIB-(*)-5-7-(**) 7 XCIB-(*)-3-1-(**) 1 XCIB-(*)-3-2-(**) 2 XCIB-(*)-3-3-(**) 3 XCIB-(*)-3-4-(**) 3 4 XCIB-(*)-3-5-(**) 5 XCIB-(*)-3-6-(**) 6 XCIB-(*)-3-7-(**) 7
For a male straight M8 plug add “M8-S-M” to the model number and additional cost to the price, for a male straight M12 plug add “M12-S-M” to the model number and additional cost to the price. For a male right-angled M8 plug add “M8-R-M” to the model number and additional cost to the price, for a male right-angled M12 plug add “M12-S-M” to the model number and additional cost to the price.
Ordering Example: XCIB-K-1-3-10, XCIB Type K probe, probe style 1 with termination Type 3 m (10') length.
Termination Types
Specify thermocouple Type: J: Iron-Constantan,
*
K: CHROMEGA®-ALOMEGA®, E: CHROMEGA®-Constantan, N: OMEGALLOY®-NICROSIL-NISIL
Use prefix of “CAL-” for assemblies to be supplied with calibration data at specified temperatures. Check Sales department for pricing.
Specify length in feet: 3' or 10' standard. Price per additional 1',
**
up to over 50' is additional. Note: Available with Nextel insulation. Change “XCIB” in model number
to “XSIB”. No extra charge.
5
8"
A
3
1. Ceramic beaded leads with compensated spade lugs.
2. Type OSTW male standard thermocouple connector to 220°C (425°F).
3. Type NHXH male ceramic connector to 650°C (1200°F).
4. Nextel leads with compensated spade lugs.
®
insulated
8"
5. Stripped leads.
6. SMPW mini-male connector to 220°C (425°F) max.
7. SHX mini-male ceramic connector to 650°C (1200°F) max.
A-36