Omega Products WMS-T-AL Installation Manual

omega.com
e-mail: info@omega.com
For latest product manuals:
omegamanual.info
WMS-T-AL
Dual Set Point Temperature Alarm
MADE IN
User’s Guide
Servicing North America:
U.S.A.: One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford, CT 06907-0047
TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
Mexico: En Espan˜ ol: (001) 203-359-7803
e-mail: espanol@omega.com FAX: (001) 203-359-7807 info@omega.com.mx
Servicing Europe:
Czech Republic: Frystatska 184, 733 01 Karviná, Czech Republic
TEL: +420 (0)59 6311899 FAX: +420 (0)59 6311114
Toll Free: 0800-1-66342 e-mail: info@omegashop.cz
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de
United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9002 Certified Northbank, Irlam, Manchester
M44 5BD United Kingdom TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: sales@omega.co.uk
OMEGAnet®Online Service Internet e-mail
omega.com info@omega.com
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.
WMS-T-AL Dual Set Point Temperature Alarm
Introduction
The WMS-T-AL is a microprocessor-based dual set point Temperature Alarm packaged in a NEMA 4X box with a transparent cover. It has been designed with two independently controlled relays. The relays are used to control power to the users temperature sensitive device(s) or to operate operator selected secondary alarms. The control module has a liquid crystal digital display and push buttons for viewing and selection of the operating mode and the alarm threshold values. The user can control three parameters for each alarm channel: Threshold delay before the relay triggers after threshold temperature is crossed, and delay time
b
efore the relay turns off after the temperature re-crosses the threshold . Each relay can be used in either the normally open or the normally closed mode. A piezoelectric buzzer in the control module can be activated to turn on when ever the alarm state is active.
General Description
The WMS-T-AL consists of two components a temperature sensor to measure temperature and a control module.
TEMPERATURE SENSOR
The temperature sensing probe is based on a precision thermistor and is designed to measure over a wide range of temperatures. The thermistor has a resistance value of 10,000 ohms at 25°C and has a highly reproducible response curve. The sensor accuracy is ±1°F (±0.55°C). Resolution is to 0.1°F (0.05°C). The measurement range is from -40°F (-40°C) to 160°F (60°C). The Alarm range is from -40°F (-3°C) to 160°F (+3°C). The temperature sensor is supplied with a 40 ft. Cable.
CONTROL MODULE
The function of the Control Module is to activate its control relays when ever user selected temperature vales are reached and sustained for user determined periods of time. The Control Module is microprocessor based and is controlled via push buttons and a two-row-liquid­crystal-display. There are Option Switches on the printed circuit board for selection of temperature units (°F or °C) , for enabling the audible alarm, and a potentiometer for controlling the LCD contrast.
User Interface
There are two modes of operation for the model WMS-T-AL Temperature Alarm. RUNNING and PAUSED. The RUNNING mode is the normal operating mode when the unit is initially powered up. The PAUSED mode is any state other than the normal OPERATING mode. Pressing any button during the RUNNING mode will place the unit in the PAUSED mode.