METER/SCANNER
AND CONTROLLER
wi8 Series
Wireless antenna
with 0.3 m (1')
cable included.
U User-Friendly, Simple to Configure
U Wireless Inputs: Thermocouple,
RTD, Temperature
U Embedded Ethernet (standard)
U 2 Alarm Outputs: Solid State
Relays (SSRs), DC Pulse,
Mechanical Relays, Analog
Voltage and Current
U Free Software
wi833-U shown
smaller than
actual size.
Works with
zED-T,
shown
smaller
than
actual size.
Visit
omega.com.
UWTC-NB9-CASS-18-U-12
wireless thermocouple/
transmitter assembly,
Works with
shown smaller
than actual size.
Visit omega.com.
WIRELESS
W
wiSeries Wireless
Monitoring and Control System
The new OMEGA wiSeries wireless monitoring
and control system features meters and scanners
compatible with a large and growing number of
OMEGA® wireless sensors:
UWTC “Universal Wireless Thermocouple”
Type J, K, T, E, R, S, B, N, and C.
UWRTD “Universal Wireless RTD”
zSeries Wireless End Devices with sensors
for temperature.
Works with UWTC wireless
thermocouple connector,
shown smaller than actual
size.
Visit omega.com.
The Smart Connector
W-28
PATENTED
Covered by U.S. and
International patents and
pending applications
TM

Rear View of wi8
The wiSeries 1⁄8 DIN panel meter and controller can
monitor up to 8 wireless sensors.
The compact instrument connects directly to an
Ethernet network and the Internet and features
OMEGA’s award-winning embedded Web Server. It is
easily configured and monitored with a Web browser
over the Ethernet network or the Internet.
Alternatively, the wi-8 meter-controller can instead be
connected to the USB port of a single computer with
a “USB Ethernet Adaptor” that are inexpensive and
widely available.
MONITOR AND ALARM
The wi-8 meter-controller comes standard with a choice
of either two Form C relays, or two SSRs (solid state
relays) that can be used for control functions or alarms.
The wi-8 meter can monitor alarm conditions for any or
all of the wireless sensors. For example, the wi-8 meter
can be set up to trip an alarm if any one of the sensors
indicated it was above or below a pre-set alarm point.
MONITOR AND CONTROL LOCALLY AND
OVER THE INTERNET
The new OMEGA® wiSeries wireless monitoring and
control system provides local monitoring and control,
along with remote Web-based monitoring of temperature
from thermocouples, RTDs, and semiconductor sensors.
The wireless sensors transmit up to 1000 m (3280')
(without obstructions or interference) to a wiSeries
monitor-controller connected directly to an Ethernet
network and the Internet. The wireless system complies
with IEEE 802.15.4 operating at 2.4 GHz.
Note: Distances for UWTC-1, UWRTD-1: up to 60 m (200'), UWTC-2,
UWRTD-2: up to 120 m (400'), zED-x-P: up to 1000 m (3280'), zED-x:
up to 90 m (300') all distances without obstructions or interference.
The OMEGA wiSeries system let’s you monitor and record
temperature over an Ethernet network or the Internet
without any special software—just your Web Browser.
WIRELESS SENSORS
OMEGA offers a wide and growing selection of wireless
sensors for a variety of applications. Depending on
application, the wireless sensors are powered by 2 “AA”
Visit omega.
com
for
ordering
information.
External
temperature lug
mount probe
included with
zED-T-TP2.
External
temperature
stick probe
included with
zED-T-TP1.
Temperature Readings of up to 8 Sensors
batteries, a single lithium battery (approx “AA” size),
2 “D” cell batteries, or an external AC Adaptor that
operates on any voltage worldwide from 100 to 240 Vac.
Wireless sensors are available with external probes
appropriate for an almost unlimited variety of industrial
and commercial applications.
ETHERNET
The wiSeries meter-controller-scanner is an
independent node on the network sending and
receiving data in standard TCP/IP packets. It is easily
configured from a Web Browser and can be password
protected. From within an Ethernet LAN or over the
Internet, the user simply types the IP address (such as
192.168.1.200) or an easy to remember name (such as
“Oven 5” or “Chicago Test Fixture”) and the wiSeries
meter serves a Web Page with the current readings.
ALARM AND EMAIL
The wiSeries meter can trigger an alarm if variables go
above or below a set point that you determine. Your
alarm can be sent by email to a single user or to a
group distribution list, including text messages to cell
phones and PDAs. The OMEGA “Mail Notifier” software
is a free and easy program for this application.
The wiSeries meter-controllers operate on any AC
voltage worldwide from 90 to 240 Vac and 50 to 60 Hz.
The meter-controller connects directly to an Ethernet
Network or the Internet. Unlike an RS232 or USB
device, it does not require a host computer.
EMBEDDED WEBSERVER
The OMEGA wiSeries wireless sensor system is easy
to install, simple to operate, and features OMEGA’s
award-winning iServer technology with an Embedded
Web Server that requires no special software.
CHARTS AND GRAPHS
The OMEGA wiSeries system serves Active Web
Pages to display real time readings and charts of
temperature. You can also log data in standard data
formats for use in a spreadsheet or data acquisition
program such as Excel or Visual Basic. OMEGA
offers a free and easy to use program for logging data
to Excel.
The virtual chart viewed on the web page is a JAVA™
Applet that records a chart over the LAN or Internet in
real time. With the OMEGA wiSeries system there is no
need to invest time and money learning a proprietary
software program to log or chart the data.
Chart scales are fully adjustable on the fly. For
example, the chart can display one minute, one
hour, one day, one week, one month or one year.
Temperature can be charted across the full span
(-40 to 125°C), or within any narrow range such as
(20 to 30°C).
W-29

WIRELESS METER SCANNER AND CONTROLLER
A complete wireless system requires at least 1 receiver (wi8XX) and 1 end device (UWTC or zED).
OMEGA offers an OPC Server software that makes
it easy to integrate the wiSeries wireless sensor system
with many popular Data Acquisition and Automation
programs offered by OMEGA, Wonderware, iConics,
Intellution, Rockwell Automation, and National Instruments,
among others.
at any set point
PROGRAMMABLE COLOR DISPLAY
The OMEGA wiSeries feature OMEGA’s patented
programmable color displays. The display can be
programmed to change color at any set point or alarm point
For example, the wiSeries can be programmed to display
the process value in GREEN during warm-up, switching
to AMBER to signal the normal operating range, and in
RED to signal an alarm condition. The changes in color are
quickly seen from a distance, and machine operators can
intuitively react to changing conditions. The colors can be
programmed to change back when the value drops back
below the alarm point or to “latch” on until being reset by
the operator.
The wiSeries can also be programmed to display only one
unchanging color: GREEN, AMBER, or RED. This is a
useful way to let an operator identify, at a glance, process
values in three separate locations, or to display three
different measurements such as Temperature, Pressure,
and Flow.
QUALITY AND TECHNOLOGY
Designed and manufactured in the USA, the innovative
OMEGA wiSeries of meters and controllers features an
extended 1 year warranty at no extra charge.
SPECIFICATIONS
ON/OFF Control Output 1 and 2
Relay: 250 Vac or 30 Vdc @ 3 A (resistive load); SPDT
SSR: 20 to 265 Vac @ 0.05 to 0.5 A (resistive load);
continuous
DC Pulse: Non-Isolated; 10 Vdc @ 20 mA
Analog Output (Output 1 only): Non-Isolated,
0 to 10 Vdc or 0 to 20 mA; 500Ω max
Operation: Direct (cool), reverse (heat); deadband; single
sensing input
Configuration: Output 1 and 2 can be configured as
Alarm 1 and 2, respectively; analog output for Output 1
can be configured as retransmission
Alarm 1 and 2 (Programmable)
Type: SPDT relay, SSR, and DC pulse
Operation: High/low, above/below, latch/unlatch,
normally open/normally closed and process/deviation;
front panel configurations; single/multiple sensing input(s)
Analog Retransmission Output (Programmable)
Type: Non-isolated, retransmission 0 to 10 Vdc or
0 to 20 mA, 500Ω max (Output 1 only)
Operation: Single sensing input; accuracy is ±1% of FS
when following conditions are satisfied; 1) input is not
scaled below 1% of input FS; 2) analog out is not scaled
below 3% of output FS
Network and Communications
Ethernet: Standards Compliance IEEE 802.3 10 Base-T
Supported Protocols: TCP/IP, ARP, HTTPGET
Connection: Screw terminals
General
Display: 4-digit, 9-segment LED, 10.2 mm (0.40") and
21 mm (0.83"), red, green and amber programmable
colors
Dimensions: 48 H x 96 W x 127 mm D (1.89 x 3.78 x 5")
Panel Cutout: 45 H x 92 mm W (1.772 x 3.622"),
Operating Temp: 0 to 55°C (32 to 131°F),
90% RH non-condensing
Line Voltage/Power: 90 to 240 Vac ±10%, 50 to 400 Hz*,
110 to 375 Vdc, equivalent voltage
No CE compliance above 60 Hz
*
Low Voltage/Power Option: 24 Vac**, 20 to 36 Vdc;
external power source must meet Safety Agency Approvals
Units can be powered safely with 24Vac power, but no
**
certification for CE are claimed
1
⁄8 DIN
WIRELESS
W
To Order Visit omega.com/wi8_series for Pricing and Details
MODEL NO. DESCRIPTION
wi833-U Wireless meter/controller for UWTC units with 2 relays: form “C” SPDT 3 A @ 120 Vac,
3 A @ 240 Vac, embedded ethernet, 90 to 240 Vac/dc, 50 to 400 Hz
wi844-U For UWTC units with two pulsed 10 Vdc @ 20 mA (for use with external SSR)
wi852-U For UWTC units with analog output selectable as either control or retransmission of process value;
wi853-U
wi822-ZT For zSeries units with two solid state relays (SSRs): 0.5 A @ 120/240 Vac continuous
wi823-ZT For zSeries units with SSR and form “C” relay
wi824-ZT For zSeries units with SSR and pulse 10 Vdc @ 20 mA (for use with external SSR)
wi854-ZT For zSeries units with analog output 0 to 10 Vdc or 0 to 20 mA @ 500 Ω max and pulsed 10 Vdc @20 mA
Other outputs options are available, please contact our Engineering Department.
wi833-ZT-DC, for low power option (20 to 36 Vdc, 24 Vac) add “-DC” to model number for additional cost.
Ordering Example: wi833-U, wireless meter/controller for UWTC units with 2 relays.
0 to 10 Vdc or 0 to 20 mA @ 500 Ω max and SSR
For UWTC units with analog output 0 to 10 Vdc or 0 to 20 mA @ 500 Ω max and form “C” relay
(for use with external SSR) and SSR
W-30