Omega Products WBTP User Manual

Wi-Fi Wireless Sensor System
05
802.11b/g Wireless Ethernet
wSeries
U Web Server U Virtual Coordinator
Data Logging Software
U Alarms by Email
or Text Message
U Temperature U Humidity U Barometric Pressure U Dual Thermocouple
Input
U Analog Process
Voltage and Current Inputs
U NEMA 4 (IP65)
Enclosure
CHART
http://75.49.246.157/GaugePost?MAC=00033400d47d&group=0
Readings Chart Setup Data
Last Updated: 2011/08/05 12:30:47
Temperature Pressure Humidity
18.82531.3
12.5 37.5
6.0 43.8
24 C
050
wTP1-CCELL shown smaller than actual size.
252.1 756.3
126.1 882.4
ChartGauge
504.2
378.2
630.3
1,008.2 hPa
0 1,008.4
Transmitter
46.3 %
Group
None
TXd259
18.82531.3
12.5 37.5
6.0 43.8
0
®
The new OMEGA
OMEGA offers Wi-Fi transmitters for analog voltage and current, temperature from digital sensors and dual thermocouples, humidity, and barometric pressure.
Included with Wireless Sensor System is the Virtual Coordinator, a data logging software application running on a computer on the network. The “VC” collects and logs data from the transmitters and serves it to Web browsing clients.
You can view charts and graphs, monitor and record readings from virtually any type of transducer over an Ethernet network or the Internet from any computer, tablet, or smart phone with a Web browser.
The Wi-Fi transmitters are powered by your choice of batteries or AC. The battery version comes with two ordinary alkaline “C-cell” batteries that can last for 2 years depending on the frequency of readings. The AC version comes with a universal
AC adaptor that operates on any voltage worldwide (110 to 240 Vac) and also includes an alkaline “AA” backup battery.
The wSeries Wi-Fi transmitters are designed for demanding industrial applications and harsh outdoor environments. The electronics are protected in a rugged weatherproof, polycarbonate NEMA 4 (IP65) rated housing.
Alarm and Email
The wSeries wireless sensor system can trigger an alarm if variables go above or below a set point that you determine. You can even set alarms to be notified by email. Alarms can be sent to a single user or to a group distribution list, including text messages to cell phones.
Charts and Graphs
The wSeries system serves active web pages to display real time readings and charts of analog voltage and current, temperature, humidity, and barometric pressure. You can also log data in standard data formats for use in
wTHP2-LCD-CCELL shown smaller than actual size.
a spreadsheet or data acquisition program such as Excel or Visual Basic.
Chart scales are fully adjustable on the fly. For example, the chart can display one minute, one hour, one day, one week, one month or one year. Temperature and humidity can be charted across the full span (-40 to 125°C, and 0 to 100% RH) or within any narrow range such as (20 to 30°C). OMEGA offers an OPC Server software that makes it easy to integrate the wSeries wireless sensor system with many popular data acquisition and automation programs offered by OMEGA, Wonderware, iConics, Intellution, Rockwell Automation, and National Instruments, among others.
Quality and Technology
The innovative wSeries system features an extended one year warranty at no extra charge.
Shop
online at
SM
To download information and to
order online, visit omega.com
X
Readings Chart Setup Data
ChartGauge
CHART
http://192.168.5.220/guage?MAC=0033400d259
Last Updated: 2011/08/05 12:30:47
Transmitter
TXd259
Group
None
0.0
Start
50.0
End
75.0
Red Range from
100.0 %
% to
Settings
Save Settings
Temperature
0.0
Start
1008.4
End
75.0
Red Range from
100.0 %
% to
Pressure
0.0
Start
50.0
End
75.0
Red Range from
100.0 %
% to
Humidity
24 C
050
6.043.8
12.5 37.5
18.82531.3
46.3 %
050
6.043.8
12.5 37.5
18.82531.3
1,008.2 hPa
01,008.4
126.1882.4
252.1756.3
378.2
504.2
630.3
Temperature Pressure Humidity
READINGS
cc
http://192.168.0.105/reading_html
Readings
00:d2:59 192.168.0.112 00:d3:fc 192.168.0.114
Temperature
Signal Battery
Updated Updated2011/06/15 12:04:20
23.0
Excellent
Good
Chart SetupData
Temperature
Humidity
Signal Battery
Readings from web browser.
Specifications
RELATIVE HUMIDITY
wTHP, wTHP2, wBTHP Accuracy/ Range: ±2% for
10 to 90%; ±3% for 5 to 10% and 90 to 95%; ±4% for 0 to 5% and 95 to 100%
Hysteresis: ±1% RH Non-Linearity: ±3% Repeatability: ±0.1% Resolution: 0.1%
TEMPERATURE
Accuracy/Range*: wTHP, wTHP2: ±0.5°C for
5 to 45°C (±0.9°F for 41 to up to ±1.5°C for -40 to 5°C and 45 to 124°C (up to ±2.7°F for
-40 to 41°F and 113 to 255°F) wTP1, wTP2: ±0.5°C for 10 to
85°C (±0.9°F for 50 to 185°F); ±1°C for -40 to 10°C and 85 to 125°C (±1.8°F for
-40 to 50°F and 185 to 257°F) wBTHP: ±0.5°C for 5 to 45°C
(±0.9°F for 41 to 113°F); up to ±1.5°C for -40 to 5°C and 45 to 85°C (up to ±2.7°F for
-40 to 41°F and 113 to 185°F)
wBTP: ±0.8°C @ 25ºC (±1.5°F @ 77ºF) ±4°C for -40 to 85°C (±7.2°F for -40 to 185ºF)
Note: Extended temperature range is for
*
external probe only.
Resolution: 0.1ºC
BAROMETRIC PRESSURE
wBTP, wBTHP Accuracy/Range: ±2 mbar for 300 to 1100 mbar @ 0 to 50°C; ±6 mbar for 300 to 1100 mbar @ -40 to 85°C
Y
Resolution: 0.1 mbar
Wireless product line continues to expand,
visit omega.com for new details!
113°F);
TXd3fcTXd259
22.5
47.5
2011/06/15 12:04:12
ANALOG VOLTAGE AND CURRENT INPUT (wVI)
Voltage Input: Differential; bipolar; ±100 mV, ±1V, ±10V
Input Impedance: 38 kΩ for voltage Current Input: Differential; bipolar;
±20 mA (5 Ω load) Accuracy: ±0.1% full range
@ 25°C Reading Rate: Periodic
(1 sample/update) or continuous (3 samples/second)
A/D Conversion: Sigma-delta Resolution: 16 bits Temperature Coefficient:
±50 ppm/°C
Common Mode Rejection: 105 dB Normal Mode Rejection: 98 dB Warm-Up to Rated Accuracy:
30 minutes
%
Excellent
Good
Gauge readings from web browser.
zTHP-P temperature/humidity probe, wBTP-P barometric pressure/temperature probe or wBTHP-P barometric pressure/temperature/ humidity probe included.
zTP1-P stick probe included.
zTP2-P temperature lug mount probe included.
PX209-015GI gauge pressure transducer with 4 to 20 mA output shown smaller than actual size, see omega.com/px209_px219.
KQXL-116G-12 Type K thermocouple probe shown smaller than actual size, see omega.com/kqxl_nqxl.
THERMOCOUPLE INPUT (wTC)
Temperature Range: Refer to thermocouple chart on next page
Temperature Accuracy: Refer to thermocouple chart on next page
Temperature Stability: 0.08°C/°C Temperature Coefficient:
±25 ppm/°C
Thermocouple Cold End Tracking: 0.1°C/°C
Thermocouple Lead Resistance:
100 Ω max
Thermocouple Type (ITS 90):
J, K, T, E, R, S, B, C, N, L (DIN J)
Warm-Up to Rated Accuracy:
30 minutes Reading Rate: Periodic
(1 sample/update) or continuous (3 samples/second)
HOTLINE
TO WIRELESS
PRODUCTS
Meter Specifications
Supported Protocols Transmitter:
TCP/IP, UDP, ARP, ICMP, DHCP, HTTP and FTP
Supported Protocols VC: TCP/IP, UDP, HTTP, FTP, SMTP and Telnet
WIRELESS COMMUNICATION
Standard: IEEE 802.11 b/g / Wi-Fi Frequency: 2.4 GHz (2402 to
2480 MHz)
Range: Up to 100 m (330') depending upon environmental considerations
Radio Power Output Level (Class 1): 20 dBm
Modulation:
802.11b Compatibility: DSSS
(CCK-11, CCK-5.5, DQPSK-2, DBPSK-1)
802.11g: OFDM (default)
Channels: 1 to 14 Channel Interval: 5 MHz Transmission Rate (Over the Air):
802.11b: 1 to 11 Mbps
802.11g: 6 to 54 Mbps
Receiver Sensitivity: -85 dBm, typ
POWER
Power Input wVI: 9 Vdc
All Others: 5 Vdc
Consumption wVI: 1.3 W max
All Others: 0.7 W max
AC Power Adaptor (Safety Qualified): Nominal Output: 5 Vdc @ 0.6 A
Nominal Output (wVI): 9 Vdc @ 0.5 A
Input: 100 to 240 Vac, 50/60 Hz Back-Up Alkaline Battery: One “AA”
1.5 Vdc (included)
POWER (wSERIES-CCELL)
Alkaline Battery: 2 “CCELL”
1.5 Vdc (included) Lifetime: Estimate of 4.3 year with
frequency of 1 reading per 2 minutes (see chart this page)
ENCLOSURE PACKAGING
Material: Polycarbonate Protection: NEMA 4 (IP65) rated
housing
Dimensions:
96.5 H x 146.3 W x 50.8 mm D (3.8 x 5.76 x 2"), not including connectors or antenna
GENERAL
Approvals: FCC Part 15C; CE EMC; 2004/108/EC, LVD 2006/95/EC, R&TTE 1999/5/EC
Operating Temperature:
-10 to 55ºC (14 to 131ºF), 90% RH non-condensing
Dimensions: mm (inch)
110.0 (4.33)
9.1 (0.36)
96.5
(3.80)
25.4 (1.00)
78.3
(3.08)
146.3 (5.76)
104.2 (4.10)
AC POWER M8
CABLE GLAND CONNECTOR (FOR WTC AND WVI ONLY)
50.8
(2.00)
THERMOCOUPLE CHART
57.1
CHROMEGA®-ALOMEGA
(2.25)
QUICK DISCONNECT CONNECTORS
M12
M8
44.4
(1.75)
CHROMEGA® -Constantan
Safety qualified universal AC power adaptor included.
30%Rh-Pt/6%Rh-Pt
L
ESTIMATED ALKALINE BATTERY LIFETIME
Update Rate C Cell Units AA Back-Up/AC Units
Continuous* (wTC, wVI) 2 weeks 2 days 10 seconds* (default) 9.6 to 20.5 months 4 weeks 1 minute 2.4 to 7 years 3.6 to 9.6 months 2 minutes 4.3 to 7 years 6 months to 1.5 years
Power save mode.
*
Important: Battery life is dependent on environmental conditions and transmitter settings.
Access Point
wSeries
Transmitters/
Sensors
(Wireless Router)
(Wired is recommended)
Input Type
Iron-Constantan
Copper-Constantan
Pt/13%Rh-Pt Pt/10%Rh-Pt
5%Re-W/26%Re-W
Nicrosil-Nisil
J DIN
Virtual Coordinator
Web Server Software
Ethernet /Computer Network
Laptop with Browser
Smartphone
with Browser
Tablet and Browser
®
Shop
online at
SM
To download information and to
order online, visit omega.com
Z
To Order Visit omega.com/wseries for Pricing and Details
Model No. Description
wTP1 Temperature sensor with stick probe, AC powered wTP2 Temperature sensor with lug mount probe, AC powered wTHP Temperature and humidity sensor, AC powered wTHP2 Temperature and humidity sensor, short probe, AC powered wBTHP Barometric pressure, temp and humidity sensor, AC powered wBTP Barometric pressure and temperature sensor, AC powered wTC Dual thermocouple inputs, AC powered wVI Analog input, AC powered wTP1-CCELL Temperature sensor with stick probe, battery powered wTP2-CCELL Temperature sensor with lug mount probe, battery powered wTHP-CCELL Temperature and humidity sensor, battery powered wTHP2-CCELL Temperature and humidity sensor, short probe, battery powered wBTHP-CCELL Barometric pressure, temp and humidity sensor, battery powered wBTP-CCELL Barometric pressure and temperature sensor, battery powered wTC-CCELL Dual thermocouple inputs, battery powered wVI-CCELL Analog input, battery powered wTP1-LCD Temperature sensor with stick probe, AC powered, LCD display wTP2-LCD Temperature sensor with lug mount probe, AC powered, LCD display wTHP-LCD Temperature and humidity sensor, AC powered, LCD display wTHP2-LCD Temperature and humidity sensor, short probe, AC powered, LCD display wBTHP-LCD Barometric pressure, temp and humidity sensor, AC powered, LCD display wBTP-LCD Barometric pressure and temperature sensor, AC powered, LCD display wTC-LCD Dual thermocouple inputs, AC powered, LCD display wVI-LCD Analog input, AC powered, LCD display wTP1-LCD-CCELL Temperature sensor with stick probe, battery powered, LCD display wTP2-LCD-CCELL Temperature sensor with lug mount probe, battery powered, LCD display wTHP-LCD-CCELL Temperature and humidity sensor, battery powered, LCD display wTHP2-LCD-CCELL Temperature and humidity sensor, short probe, battery powered, LCD display wBTHP-LCD-CCELL Barometric pressure, temp and humidity sensor, battery powered, LCD display wBTP-LCD-CCELL Barometric pressure and temperature sensor, battery powered, LCD display wTC-LCD-CCELL Dual thermocouple inputs, battery powered, LCD display wVI-LCD-CCELL Analog input, battery powered, LCD display Replacement Probes zTP1-P External stick probe with temperature sensor, 3 m (10') cable zTP2-P External lug mount probe with temperature sensor, 3 m (10') cable zTHP-P External industrial probe with temperature and humidity sensor, 3 m (10') cable zTHP2 External short industrial probe with temperature and humidity sensor wBTP-P External industrial probe with barometric pressure, temperature sensor, 3 m (10') cable wBTHP-P Calibration for New Units CAL-3-HU NIST traceable calibration certificate, 3 humidity points: 25%, 50%, 75%,
CAL-3-HU-P-T NIST traceable calibration certificate, 3 humidity, barometric pressure,
CAL-3-P NIST traceable calibration certificate, 3 barometric pressure points
and one temperature 25°C (for new units)
CAL-3-T NIST traceable calibration certificate, 3 temperature points (for new units) CT485B-CAL-KIT Calibration kit, 33% and 75% RH standards
Comes complete with 2 “CCELL” batteries or AC power adaptor, and “AA” backup battery. Ordering Example: Two wTP1-LCD, wireless transmitters with LCD, AC power and external temperature sensor with 3 m (10') cable,
and two CAL-3-T, NIST traceable calibration certificate.
External industrial probe with barometric pressure, temp and humidity sensor, 3 m (10') cable
1 temperature point 25°C (for new units)
and temperature points (for new units)
AA
Wireless product line continues to expand,
visit omega.com for new details!
HOTLINE
TO WIRELESS
PRODUCTS
Loading...