Omega Products UWXL-24-IR-1 User Manual

Long Distance Industrial Wireless Transmitters and Receivers
UWXL Series
UWXL-24-TC shown smaller
U Thermocouple, RTD,
Infrared Temperature, RH, pH, Process Voltage/ Current and Input Models
U J, K, T, E, R, S, B, and N
Thermocouples
U 385 and 392 Pt100 RTD
Probes
U IP68 Rated Enclosure–
Dust- and Water-Tight
U Free Software Converts
Your PC Into a Multi­Channel Chart Recorder or Data Logger
U Compatible with
Both UWTC-REC and UWTC-REC-NEMA Wireless Receivers
U Long Battery Life
The UWXL Series industrial wireless transmitters from OMEGA offer unparalleled flexibility for process measurement applications. Capable of ranges to 450 m (1500’) line of sight (LOS), the UWXL transmitters are designed for a variety of applications, including temperature, infrared temperature, relative humidity, process transducers with standard voltage or current outputs, as well as pH. Thermocouple models are user-configurable for
Dust- and
Water-Tight
any of 9 calibrations, while RTD units are compatible with both
0.00385 and 0.00392 curve Pt100 sensors. UWXL transmitters are programmable to transmit data at intervals configurable from once every 2 seconds to every 2 minutes. Transmitted data includes the process measurement along with the ambient temperature, RF signal strength and battery condition. Software provided with each model can display this information in real time. This free software allows you to use your PC as a multi-channel meter, recorder or data logger; data can also be exported to a standard
than actual size.
spreadsheet file. UWXL transmitters are compatible
with a wide variety of OMEGA wireless receivers. UWTC-REC receivers are available with optional analog output, alarms and display, while the UWTC-REC-NEMA receivers add a NEMA rated enclosure. Receivers can accept up to 48 transmitters. Receivers with analog outputs can also retransmit data through a wired connection, as an analog voltage, current or thermocouple signal, to interface with a controller, PLC or data acquisition interface.
Up to 450 m
(1500') Line of
Sight Range
IP68
Enclosure
Models shown smaller than actual size.
Process Voltage Transmitter
Humidity Transmitter
Thermocouple Transmitter
Typical Multi-Unit Wireless
Automation System
Up to 450 m (1500')
Infrared Transmitter
UWTC-REC4
receiver.
W-31
Analog Output (Wired)
HE-XE102 PLC (Programmable Logic
Controller), visit omega.com/ocsxl
Transmitter model
UWXL-24-RH-RPI.
Humidity/temperature
sensor included.
UWXL-RH features a detachable combination humidity/temperature sensor that can be remotely mounted.
Temperature transmitter models
UWXL-TC-24, UWXL-RTD.
Thermocouple and RTD models feature screw terminal connections that allow you to connect a wide range of sensors and probes. Models
with intergral probes are available
contact factory.
Transmitter model
UWXL-IR-1.
Infrared sensor
head included.
W
UWXL-IR-1 features a remotely mounted sensor head to measure non-contact infrared temperature.
Common Specifications
Computer Interface: USB Transmit Sample Rate: Programmable
from 2 second to 120 second
Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz, direct sequence
spread spectrum, (2.450 to 2.490 GHz– 12 RF channels)
RF Output Power: 18 dBm (63 mW) Range of RF Link: Up to 450 m (1500')
outdoor line of sight; up to 90 m (300') indoor/urban
RF Data Packet Standard: IEEE
802.15.4, open communication architecture
Software (Included Free): Requires Windows operating system
Power: One 3.6V, Lithium C Cell (included)
Battery Life (Typical): 3 years; at 1 sample/minute reading rate @ 25°C
Operating Temperature: -10 to 70°C (14 to 158°F)
Storage Temperature: -40 to 80°C (-40 to 176°F)
Model UWXL-24-TC
Input: J, K, T, E, R, S, B, C or N
thermocouple, software selectable
Measurement Range:
J: -100 to 760°C (-148 to 1400°F) K: -100 to 1260°C (-148 to 2300°F) T: -200 to 400°C (-328 to 752°F) E: -200 to 1000°C (-328 to 1832°F) R: 260 to 1760°C (500 to 3200°F) S: 260 to 1760°C (500 to 3200°F) B: 870 to 1820°C (1598 to 3308°F) C: 0 to 2315°C (32 to 4200°F) N: -100 to 1260°C (-148 to 2300°F)
®
2000, XP or Vista (32 bit)
Accuracy @ 25°C: Types J and K: ±0.5% rdg or ±1.0°C
(1.8°F), whichever is greater Types T, E, and N: ±0.5% rdg or ±2.0°C (3.6°F), whichever is greater Types R, S, B and C: ±0.5% FS
Resolution: 1°C/1°F Sensor Connection: Screw terminals
Model UWXL-24-RTD
Input: Pt100 RTD; 0.00385 or 0.00392
curve, software selectable
Measurement Range: Pt100, 0.00385: -200 to 850°C
(-328 to 1562°F) Pt100, 0.00392: -100 to 457°C (-148 to 854°F)
Accuracy: ±0.5°C (1.0°F) Resolution: 1°C/1°F Sensor Connection: Screw
terminals
Model UWXL-24-IR-1
Temperature Range: -18 to 538°C
(0 to 1000°F) Accuracy: ±2% rdg or 2.2°C (4°F),
whichever is greater; @ 22°C (72°F) ambient temperature and emissivity 0.95
Optical Field of View: 6:1 (distance/ spot size)
Sensor Head Cable Extension: Up to 15 m (50’) total
Repeatability: ±1% rdg Spectral Response: 5 to 14 microns Response Time: 100 ms (0 to 63% of
final value)
Emissivity: 0.1 to 1.00, adjustable
Operating Ambient: Sensor Head: 0 to 70°C (32 to158°F)
Sensor Head (-HT Model): 0 to 85°C (32 to 185°F) Sensor head with OS100-WC (Water Cooling Jacket): 0 to 200°C (32 to 392°F) Relative Humidity: Less than 95% RH, non-condensing
OS100-WC Water Flow Rate:
0.25 GPM, room temperature Thermal Shock: About 30 minute
for 25°C (77°F) abrupt ambient temperature change
Warm-Up Period: 3 minutes OS100-AP Air Flow Rate: 1 CFM
(0.5 L/s) (1 x 2.5")
OS100-LA Laser Sight Accessory
Wavelength (Color): 630 to 670 nm (red) Operating Distance (Laser Dot):
Up to 9.1 m (30') Max Output Optical Power: Less than 1 mW @ -6°C (22°F) ambient temperature European Classification: Class 2, EN60825-1/11.2001 Max Operating Current: 45 mA @ 3 Vdc FDA Classification: Complies with 21 CFR 1040.10, Class II laser product
Beam Diameter: 5 mm (0.20") Beam Divergence: <2 mrad Operating Ambient: 0 to 50°C (32 to
122°F); <95% RH, non-condensing Power Switch: On/off slide switch on the battery pack
Power Indicator: Red LED Power: Battery pack, 3 Vdc (consists
of two 1.5 Vdc “AA” lithium batteries, included)
W-32
Loading...
+ 3 hidden pages