Omega Products UWXL-24-IR-1 User Manual

Page 1
Long Distance Industrial Wireless Transmitters and Receivers
UWXL Series
UWXL-24-TC shown smaller
U Thermocouple, RTD,
Infrared Temperature, RH, pH, Process Voltage/ Current and Input Models
U J, K, T, E, R, S, B, and N
Thermocouples
U 385 and 392 Pt100 RTD
Probes
U IP68 Rated Enclosure–
Dust- and Water-Tight
U Free Software Converts
Your PC Into a Multi­Channel Chart Recorder or Data Logger
U Compatible with
Both UWTC-REC and UWTC-REC-NEMA Wireless Receivers
U Long Battery Life
The UWXL Series industrial wireless transmitters from OMEGA offer unparalleled flexibility for process measurement applications. Capable of ranges to 450 m (1500’) line of sight (LOS), the UWXL transmitters are designed for a variety of applications, including temperature, infrared temperature, relative humidity, process transducers with standard voltage or current outputs, as well as pH. Thermocouple models are user-configurable for
Dust- and
Water-Tight
any of 9 calibrations, while RTD units are compatible with both
0.00385 and 0.00392 curve Pt100 sensors. UWXL transmitters are programmable to transmit data at intervals configurable from once every 2 seconds to every 2 minutes. Transmitted data includes the process measurement along with the ambient temperature, RF signal strength and battery condition. Software provided with each model can display this information in real time. This free software allows you to use your PC as a multi-channel meter, recorder or data logger; data can also be exported to a standard
than actual size.
spreadsheet file. UWXL transmitters are compatible
with a wide variety of OMEGA wireless receivers. UWTC-REC receivers are available with optional analog output, alarms and display, while the UWTC-REC-NEMA receivers add a NEMA rated enclosure. Receivers can accept up to 48 transmitters. Receivers with analog outputs can also retransmit data through a wired connection, as an analog voltage, current or thermocouple signal, to interface with a controller, PLC or data acquisition interface.
Up to 450 m
(1500') Line of
Sight Range
IP68
Enclosure
Models shown smaller than actual size.
Process Voltage Transmitter
Humidity Transmitter
Thermocouple Transmitter
Typical Multi-Unit Wireless
Automation System
Up to 450 m (1500')
Infrared Transmitter
UWTC-REC4
receiver.
W-31
Analog Output (Wired)
HE-XE102 PLC (Programmable Logic
Controller), visit omega.com/ocsxl
Page 2
Transmitter model
UWXL-24-RH-RPI.
Humidity/temperature
sensor included.
UWXL-RH features a detachable combination humidity/temperature sensor that can be remotely mounted.
Temperature transmitter models
UWXL-TC-24, UWXL-RTD.
Thermocouple and RTD models feature screw terminal connections that allow you to connect a wide range of sensors and probes. Models
with intergral probes are available
contact factory.
Transmitter model
UWXL-IR-1.
Infrared sensor
head included.
W
UWXL-IR-1 features a remotely mounted sensor head to measure non-contact infrared temperature.
Common Specifications
Computer Interface: USB Transmit Sample Rate: Programmable
from 2 second to 120 second
Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz, direct sequence
spread spectrum, (2.450 to 2.490 GHz– 12 RF channels)
RF Output Power: 18 dBm (63 mW) Range of RF Link: Up to 450 m (1500')
outdoor line of sight; up to 90 m (300') indoor/urban
RF Data Packet Standard: IEEE
802.15.4, open communication architecture
Software (Included Free): Requires Windows operating system
Power: One 3.6V, Lithium C Cell (included)
Battery Life (Typical): 3 years; at 1 sample/minute reading rate @ 25°C
Operating Temperature: -10 to 70°C (14 to 158°F)
Storage Temperature: -40 to 80°C (-40 to 176°F)
Model UWXL-24-TC
Input: J, K, T, E, R, S, B, C or N
thermocouple, software selectable
Measurement Range:
J: -100 to 760°C (-148 to 1400°F) K: -100 to 1260°C (-148 to 2300°F) T: -200 to 400°C (-328 to 752°F) E: -200 to 1000°C (-328 to 1832°F) R: 260 to 1760°C (500 to 3200°F) S: 260 to 1760°C (500 to 3200°F) B: 870 to 1820°C (1598 to 3308°F) C: 0 to 2315°C (32 to 4200°F) N: -100 to 1260°C (-148 to 2300°F)
®
2000, XP or Vista (32 bit)
Accuracy @ 25°C: Types J and K: ±0.5% rdg or ±1.0°C
(1.8°F), whichever is greater Types T, E, and N: ±0.5% rdg or ±2.0°C (3.6°F), whichever is greater Types R, S, B and C: ±0.5% FS
Resolution: 1°C/1°F Sensor Connection: Screw terminals
Model UWXL-24-RTD
Input: Pt100 RTD; 0.00385 or 0.00392
curve, software selectable
Measurement Range: Pt100, 0.00385: -200 to 850°C
(-328 to 1562°F) Pt100, 0.00392: -100 to 457°C (-148 to 854°F)
Accuracy: ±0.5°C (1.0°F) Resolution: 1°C/1°F Sensor Connection: Screw
terminals
Model UWXL-24-IR-1
Temperature Range: -18 to 538°C
(0 to 1000°F) Accuracy: ±2% rdg or 2.2°C (4°F),
whichever is greater; @ 22°C (72°F) ambient temperature and emissivity 0.95
Optical Field of View: 6:1 (distance/ spot size)
Sensor Head Cable Extension: Up to 15 m (50’) total
Repeatability: ±1% rdg Spectral Response: 5 to 14 microns Response Time: 100 ms (0 to 63% of
final value)
Emissivity: 0.1 to 1.00, adjustable
Operating Ambient: Sensor Head: 0 to 70°C (32 to158°F)
Sensor Head (-HT Model): 0 to 85°C (32 to 185°F) Sensor head with OS100-WC (Water Cooling Jacket): 0 to 200°C (32 to 392°F) Relative Humidity: Less than 95% RH, non-condensing
OS100-WC Water Flow Rate:
0.25 GPM, room temperature Thermal Shock: About 30 minute
for 25°C (77°F) abrupt ambient temperature change
Warm-Up Period: 3 minutes OS100-AP Air Flow Rate: 1 CFM
(0.5 L/s) (1 x 2.5")
OS100-LA Laser Sight Accessory
Wavelength (Color): 630 to 670 nm (red) Operating Distance (Laser Dot):
Up to 9.1 m (30') Max Output Optical Power: Less than 1 mW @ -6°C (22°F) ambient temperature European Classification: Class 2, EN60825-1/11.2001 Max Operating Current: 45 mA @ 3 Vdc FDA Classification: Complies with 21 CFR 1040.10, Class II laser product
Beam Diameter: 5 mm (0.20") Beam Divergence: <2 mrad Operating Ambient: 0 to 50°C (32 to
122°F); <95% RH, non-condensing Power Switch: On/off slide switch on the battery pack
Power Indicator: Red LED Power: Battery pack, 3 Vdc (consists
of two 1.5 Vdc “AA” lithium batteries, included)
W-32
Page 3
All models shown smaller than actual size.
UWXL-PC Transmitter.
Process Input model UWXL-24-PC features M12 connection that allows you to connect a wide range sensors or transducers that have voltage or current output.
UWTC-REC2-D-NEMA Transceiver.
UWTC-REC1-NEMA Receiver.
UWTC-REC1-NEMA is mounted in a water tight, Polycarbonate/ ABS IP68 rated enclosure. This unit will receive data from up to 48 transmitters and is powered directly by the USB connection on your computer (no analog output provided).
Remote Antenna Kit UWXL-RAK
UWTC-REC2-D-NEMA is mounted in a water tight, Polycarbonate/ ABS IP68 rated enclosure. This unit will receive data from up to 48 transmitters and provides a local displayed reading and a wired retransmission analog output.
Model UWXL-24-RH
Temperature
Range: -17 to 49°C (2 to 120°F) Accuracy: ±1°C (±1.8°F) @ 25°C
Model UWXL-24-PC
Input: 0 to 1 Vdc, 0 to 5 Vdc, 0 to 10 Vdc,
0 to 20 A, 4 to 20 mA
Accuracy: ±0.1% FS @ 25°C Resolution: 12 to 15 bit Connection: M12
Resolution: 1°C/1°F Relative Humidity
Range: 2 to 98% RH
Accuracy: ±2.5% RH from 20 to 80% RH; ±3.5% RH <20 and >80% RH @ 25°C (76°F) Resolution: 1% RH
Cable
Stand
Antenna
UWXL-RAK allows you to use a directional antenna to maximize transmission range to your base receiver. Includes directional antenna, 200 mm (8") antenna extension cable and mounting bracket.
Model UWXL-24-PH
pH Input:
Range: 0 to 14 pH Accuracy: ±0.1 pH @ 25°C Resolution: 0.01 pH Response Time: 2 s Input Connection: BNC Temperature Compensation: Automatic, 0 to 100°C (32 to 212°F)
RTD Temperature Input: Type: Pt100 Ω RTD, 0.00385 curve Range: 0 to 100°C (32 to 212°F) Accuracy: ±1°C (1.8°F) Resolution: 0.1° Input Connection: Screw terminals
W-33
Page 4
Connect a Wireless Receiver to Your Computer, PLC or Data Logger to Form a Complete Wireless System!
UWTC-REC1.
UWTC-REC1 will receive data from up to 48 transmitters and is powered directly by the USB connection on your computer (no analog output provided).
See omega.com
All models shown
smaller than actual size.
UWTC-REC2-D
receiver.
UWTC-REC2-D will receive data from up to 48 transmitters. This model provides a displayed reading and a retransmitted, hard wired analog output for 1 user selected transmitter in your system. Requires DC power adaptor (included).
See omega.com
UWTC-REC3 32-channel receiver with ethernet.
UWTC-REC3 receiver/host with ethernet is compatible with UWTC, UWRTD, UWRH and UWIR transmitters and connects directly to your network or the Internet—no PC.
See omega.com
Typical Multi-Unit Wireless Data Logging System
UWTC-REC4
receiver.
UWTC-REC4 will receive data from up to 48 transmitters. This model provides a scalable retransmitted, hard wired analog output for 4 user selected transmitters in your system. Requires 12 to 24 Vdc power supply.
See omega.com
W
Thermocouple Transmitter
Process Voltage Transmitter
Monitor up to 48 different wireless transmitters, simultaneously on your PC. Display shows process reading, signal strength and batter level in real-time.
Up to 450 m(1500')
Humidity Transmitter
Chart up to 48 different wireless transmitters, simultaneously on your PC.
Infrared Transmitter
W-34
UWTC-REC1
USB receiver
Collect and log data for up to 48 different wireless transmitters at the same time. Record, save or download to a spread sheet up to 32 thousand individual readings.
Laptop not included.
Page 5
UWXL temperature models with integral thermocouple or RTD probes are also available. Contact OMEGA for pricing and availability. Visit omega.com/uwxl for the latest features and specifications.
To Order Visit omega.com/uwxl for Pricing and Details
Model No. Description UWXL-24-TC Wireless thermocouple transmitter UWXL-24-RTD Wireless RTD (Pt100) transmitter UWXL-24-PC Wireless process voltage and current input transmitter UWXL-24-IR-1 Wireless infrared temperature transmitter UWXL-24-RH-RPI Wireless humidity/temperature transmitter with remote probe UWXL-24-PH Wireless pH/temperature transmitter UWXL-RAK Remote antenna kit (See omega.com)
Receivers/Accessories
Model No. Description
UWTC-REC1 48-channel wireless USB powered receiver
UWTC-REC2-(*) 48-channel wireless receiver with 1-channel analog
UWTC-REC2-D-(*) 48-channel wireless receiver with 1-channel analog output,
UWTC-REC3 32-channel wireless receiver/host with ethernet
UWTC-REC4-(*) Wireless DIN-rail receiver with 4-channel analog
UWTC-CB12 12-channel USB control box with 12 form “C” relays UWTC-BATT-C Replacement battery, 3.6V, lithium “C” cell assembly PHE-1311 Gel-filled pH electrode, general purpose PRTF-10-2-1000-1/8-6-E-TA3F Pt1000 RTD probe,
OS100-MB Sensor head mounting bracket for UWXL-24-IR-1 OS100-AP Sensor head air purge collar for UWXL-24-IR-1 OS100-WC Sensor head water cool jacket, up to 200°C (392°F) for UWXL-24-IR-1 OS100-LS Laser sighting accessory for UWXL-24-IR-1
Specify analog output “V1” for 0 to 5 Vdc; “V2” for 0 to 10 Vdc, “MA” for 4 to 20 mA or “TC” for type K thermocouple signal.
*
Comes complete with measurement/charting/data logging software, 3.6V lithium battery and operator’s manual. UWTC-REC2 units also include DC power adaptor.
Ordering Examples: UWXL-24-TC, wireless thermocouple transmitter, UWTC-REC1, 48-channel USB receiver, and UWTC-BATT-C, spare battery.
UWXL-24-IR-1, wireless infrared temperature transmitter, OS100-MB, sensor head mounting bracket, UWTC-REC4-MA, 48-channel receiver with 4 to 20 mA analog output, and UWTC-BATT-C, spare battery.
UWXL-24-RH-RPI, wireless humidity/temperature transmitter, UWXL-24-PC, wireless process input transmitter, UWTC-REC2-D-MA 48-channel receiver with 4 to 20 mA analog output.
(no analog output or alarms)
output and alarms
alarms and display
(Thermocouple, RTD, RH and IR models only)
output, and alarms
1
8" diameter, 6" L, with wire, 12 m (40') PFA insulated
cable with connector
W-35