M-2
Input Types Range Accuracy
Process Voltage 0 to 10 Vdc
0.2% of full scale
Process Current
0 to 20 mA or 4
0.2% of full scale
to 20mA
CHROMEGA®- -148 to 1600°F 3.6°F
ALOMEGA
®
-100 to 871°C 2°C
Iron-Constantan
-103 to 1202°F 3.6°F
-75 to 650°C 2°C
Copper-Constantan
-103 to 716°F 1.8°F
-75 to 380°C 1.0°C
Pt/13%Rh-Pt
500 to 3110°F 3.6°F
260 to 1710°C 2°C
Inputs
Specifications
Display Range: -999 to 9999 counts
(highest display resolution mode -9.99 to
9.999, Automatically shifts the decimal
point right or left depending on the
process value of the meter)
Verbalize (Speech) Range:
±9999 counts (highest speech resolution
mode -9999.999 to 9999.999 counts)
Command/Continuous Talk:
Command/continuous speech mode
selection from the button
Volume Control: Set via front buttons
keypad, 8 levels at 4 dB intervals
Color Change LED Display:
Three color change LED display; GREEN
(normal operation condition), AMBER (in
TC open or overrange condition) and
Red
(in alarm condition)
Display Decimal Points Auto Shifting:
Automatically shifts the decimal point
right or left depending on the process
value of the meter on the LED display
within your selected decimal point
Relay Outputs: 2 Form C (SPDT) relays,
250 Vac or 30 Vdc @ 3A (resistive load)
Power Input:
90 to 240 Vac, 50 to 400 Hz
110 to 375 Vdc, equivalent voltage
PC User Interface Software Features:
• Selectable talking interval, 0 to 120 sec
• Selectable decimal point
• Adjustable input offset
• High and low alarm settings
• Analog input scaling
• Change engineering unit—over 100
engineering unit selections
• Selectable alarm output dead band
Selectable Alarm Deadband:
Range 0 to 999
Maximum Recommended
Wire Size: 18 AWG
Inductive Loads: To prolong relay
contact life and suppress interference, it is
a recommended engineering practice to
use a snubber circuit, such as OMEGA’s
CNQUENCHARC
Input Select Indication: Green LED
Alarm Indication: Flash red LED, LED
display color changing
Speech Sampling Rate: 8 KHz
Speaker: Built-in and external speaker, 8 Ω
Operating Ambient Temperature:
0 to 50°C (32 to 122°F)
Operating Relative Humidity:
0 to 95% RH (non-condensing)
Dimensions: 131 L x 96 W x 48 mm D
(5.13 x 3.78 x 1.89")
Panel Cutout Size:
1
⁄8 DIN
Weight: 250 g (0.55 lb)
Verbaview User Software
AutoScaling automatically
shifts the decimal point right
or left depending on the
process value of the meter.
999.9
1000
To Order
(Specify Model Number)
Model No. Price Description
UV1000-PM $285 Universal verbalizer, English, with 2 relays:
form “C” SPDT 3 A @ 30 Vdc, 3 A @ 250 Vac,
external loudspeaker
AVAILABLE FOR FAST DELIVERY!
Comes complete with operator’s manual, external speaker, and CD with configuration program.
Ordering Example: UV1000-PM, universal verbalizer, English, $285.
Dimensions: mm (in)